ac compressor isn't starting !

  Рет қаралды 57,577

Cold Flash AC

Cold Flash AC

Күн бұрын

Пікірлер: 125
@JJones-dm7zy
@JJones-dm7zy 2 жыл бұрын
Interesting problem and thumbs up for the nice clear video, audio and commentary. I moved to Las Vegas in 2019 and never had a central AC system before. The first thing I did since AC is so important here was start trying to learn how the system works and buy spare parts for common problems. I have an electrical background and ended up changing a capacitor, the contactor and repairing some burned insulation on some wires that the capacitor caused. This was on a Goodman unit that was a little over a year old. I made sure I used an American made capacitor. A few months after that the contactor started buzzing and I had to change it again. I do not blame Goodman since these are generic parts and all manufacturers now seem to use the cheapest imported parts they can source. Thanks from a new subscriber.
@coldflashac6443
@coldflashac6443 2 жыл бұрын
Good to ear , yea it really helps knowing about ac since its so important in some areas of the country, thank you for the sub my friend
@SoCalRobots
@SoCalRobots 6 ай бұрын
This is exactly what I was thinking of doing and now you've confirmed it. I'll just hit mine to start every time lol! better than spending $11,000 for now
@briley337
@briley337 Жыл бұрын
This video saved me hundreds of dollars. Thank you so much!
@MacMcCabe2456
@MacMcCabe2456 2 жыл бұрын
The 5-2-1 Hard Start kits are the best out there.
@coldflashac6443
@coldflashac6443 2 жыл бұрын
yes sir
@JoseFernandez-ly7qs
@JoseFernandez-ly7qs 3 ай бұрын
Soft starts are better
@shawnd567
@shawnd567 2 жыл бұрын
I've done this before. Fix lasted the rest of the summer until we replaced the whole unit. Unit was 37 years old and honestly probably could have kept running.
@coldflashac6443
@coldflashac6443 2 жыл бұрын
nice !
@jimdefilippis9630
@jimdefilippis9630 2 жыл бұрын
Nice info. Every time I run into a compressor drawing locked rotor I am going to give it a shot with a rubber mallet and see if I get lucky. Lol~ thanks for the video
@coldflashac6443
@coldflashac6443 2 жыл бұрын
Nice ! Good to know you like it
@JobSalazar
@JobSalazar 2 жыл бұрын
Thanks for the tip, have the same problem with a Goldman for days, I’ll try that trick and save big with a new compressor. Hopefully it will do the job…good luck!
@coldflashac6443
@coldflashac6443 2 жыл бұрын
thanks for the comment !
@Reaked
@Reaked 6 ай бұрын
Update: Did that work for you? Just curious.
@adolfoayvar3288
@adolfoayvar3288 5 ай бұрын
Your AC unit is a Goodman not a Goldman
@D4x4Bronc
@D4x4Bronc 2 жыл бұрын
What does a hard start kit actually do? Also will the hammer trick work on grounding out compressors that throw breakers?
@coldflashac6443
@coldflashac6443 2 жыл бұрын
Star kit capacitor will help the compressor start winding on start up and de energize after start up by the relay , lowers electric bill aswell , no a shorted to ground compressor is an internal short meaning one of the winding wire broke and is touching the compressor case sending the voltage to ground and tripping the braker , rhis was a lock rotor amp problem meaning compressor is going off on over. Load cause cant start getting stuck on high amps not moving
@D4x4Bronc
@D4x4Bronc 2 жыл бұрын
@@coldflashac6443 that was a great explanation thanks for letting me know the winding broke and is touching the case. I had no idea what actually happens didn't know if it was a brush or something stuck. I"ll sub thanks. Is the paying for the labor for compressor replacement the same cost as new condenser unit from goodman?
@tesakotukaka6222
@tesakotukaka6222 2 жыл бұрын
@@D4x4Bronc just change whole condenser better warranty
@georgepetrillo7316
@georgepetrillo7316 5 ай бұрын
Excellant video. My issue is a little different. Had a power outage today. Power came back on and then it went off again. When the power came back on I noticed that the a/c was not blowing cold. The a/c breaker switch was tripped. Reset the breaker, heard a buzz, breaker tripped. Reset the breaker again, heard a buzz, breaker tripped again. Went to the compressor outside and the fan was not running. However, the fan spins freely by hand. Now I have the breaker off till I get this sorted out out. Don't know if its a bad capacitor , start switch or contactor.
@coldflashac6443
@coldflashac6443 5 ай бұрын
The buzz is the compressor trying to start or is locked on lock rotor amps causing the wire to over heat and tripping your breaker this video was the same issue you could also have a bad capacitor if is an older unit recommend having a start kit capacitor , please call a professional
@georgepetrillo7316
@georgepetrillo7316 5 ай бұрын
@@coldflashac6443 Had one a/c company come over to trouble shoot. Found it was a bad compressor. Didn't want to get just one diagnosis so I called another a/c company to do the same diagnosis. 2nd person came over a few hours after the first person. The second a/c tech did some trouble shooting and found the same thing. I didn't mention that I already had a diagnosis because I wanted to the 2nd person to fully trouble shoot the problem.
@chandlervoit4630
@chandlervoit4630 2 жыл бұрын
Watching from fort myers. First local channel I’ve found.
@coldflashac6443
@coldflashac6443 2 жыл бұрын
Wow awesome 👏 ❤️
@MysticalMe131
@MysticalMe131 2 жыл бұрын
Really like your videos. So the problem was the Compressor?
@coldflashac6443
@coldflashac6443 2 жыл бұрын
Yes it was
@usa5046
@usa5046 2 жыл бұрын
Very nice
@fldave612
@fldave612 Жыл бұрын
29.4 is outside of limits on the herm, but not low enough to keep it from starting.
@jorgeespinoza238
@jorgeespinoza238 2 жыл бұрын
Good thing it's temporary. Those black zip ties never last, metal straps are clutch
@coldflashac6443
@coldflashac6443 2 жыл бұрын
yes ! thanks for the comment
@jordanhenshaw
@jordanhenshaw 11 ай бұрын
High superheat low subcool? Seems like possible low charge contributed to floodback and you had flooded starts or slugging which may have deprived comp of oil, contributing to LRA. Verify proper cap rating is Copeland spec (I've often found 30's on comps meant for 35's and 35's on comps meant for 30's.) and make sure the dang superheat and subcool numbers are definitely not indicative of low charge (as pictured in the video, they are). The unstable amp draw on compressor on startup may have been oil returning? Not sure though. If compressor actually got replaced (it shouldn't based just on the info in this video), definitely dump the oil and then drill out the evap if oil level turns out to be super low.
@AngelHVACR
@AngelHVACR 2 жыл бұрын
The company i work for never fixes compressors we just replace whole unit 🤣😭😭😭
@coldflashac6443
@coldflashac6443 2 жыл бұрын
jajaja
@972958
@972958 2 жыл бұрын
Same lmfao
@dontarguewithfools
@dontarguewithfools 2 жыл бұрын
Hell yea hell with changing out a compressor unless it's a side job for straight cash
@jayc4715
@jayc4715 Жыл бұрын
Lazy overcharging POS's
@sandwichman4534
@sandwichman4534 8 ай бұрын
​@@jayc4715I agree with you. It take a low SOB to overcharge someone if it can be fixed.
@herkyfreeman9316
@herkyfreeman9316 Жыл бұрын
condenser motor lock up at nite would that mess up the compressor too its a old york unit
@coldflashac6443
@coldflashac6443 Жыл бұрын
Yes too much can cock up the compressor oil and cause premature compressor failure , i recommend you to have a high pressure and low pressure switch done by a professional
@GoodMemoriesToRemeber
@GoodMemoriesToRemeber 5 ай бұрын
pls help, how do i know which ac hard start kit for my residential ac my is lennox 5 ton
@coldflashac6443
@coldflashac6443 5 ай бұрын
CSRU2 CSR-U2 AC Hard Start Kit 3.5 to 5 tons
@GoodMemoriesToRemeber
@GoodMemoriesToRemeber 5 ай бұрын
@@coldflashac6443thank you
@DJV94022
@DJV94022 2 жыл бұрын
This is just like when you have to tap your starter when its going out
@Ulysses87
@Ulysses87 Жыл бұрын
Hits was not the fix. It was your Hard-start kit… but if it works. It works… 😅 👍🏼👍🏼👍🏼👍🏼
@coldflashac6443
@coldflashac6443 Жыл бұрын
Yes sir hitting works try it
@znrctrnn
@znrctrnn Жыл бұрын
How old was the unit? Was it worth ordering the compressor?
@coldflashac6443
@coldflashac6443 Жыл бұрын
New install
@user-bw6xz7vm3l
@user-bw6xz7vm3l 2 жыл бұрын
Love your videos man
@coldflashac6443
@coldflashac6443 2 жыл бұрын
thanks for the love :)
@brianb5779
@brianb5779 2 жыл бұрын
What did you do to bleed the capacitor, i didnt catch that. Thanks for sharing
@coldflashac6443
@coldflashac6443 2 жыл бұрын
Using the meter leads on voltage , meter has a resistor inside so if your se your lead on the capacitor herm to common and fan to common until the voltage is 0 , it will bleed the voltage
@brianb5779
@brianb5779 2 жыл бұрын
@@coldflashac6443 Thanks brother i appreciate it
@coldflashac6443
@coldflashac6443 2 жыл бұрын
@@brianb5779 any time my dude
@FarhanAli-dq8eh
@FarhanAli-dq8eh 2 жыл бұрын
@@coldflashac6443 great tip!
@coldflashac6443
@coldflashac6443 2 жыл бұрын
@@FarhanAli-dq8eh thank you sir 🙏🏼
@rickl7024
@rickl7024 2 жыл бұрын
Interesting video,,, seen this done on a old frig to get it running
@coldflashac6443
@coldflashac6443 2 жыл бұрын
nice !
@jlgmdano
@jlgmdano Жыл бұрын
Where can I order a compressor? Or better yet, where do I check for warranty?
@coldflashac6443
@coldflashac6443 Жыл бұрын
Ac company website
@gabrielmerza6904
@gabrielmerza6904 2 жыл бұрын
Hey man , just found your video I was thinking to go to HVAC school I live I Arizona my question is it good career to make a living? Or I’m gonna end up in company who pay $22 hourly? Thank you
@coldflashac6443
@coldflashac6443 2 жыл бұрын
Yea sir is a good career , has a really big field of opportunity, but service and commercial are really good money wise
@MRW21783
@MRW21783 2 жыл бұрын
Just had the same thing happen last week up here in MI. She's running but idk for how long lol.
@coldflashac6443
@coldflashac6443 2 жыл бұрын
Nice brother, that would save you from a yelling customer lol
@JohnAudioTech
@JohnAudioTech 2 жыл бұрын
Charge 2x $ for having to haul the compressor over that obstacle course.
@coldflashac6443
@coldflashac6443 2 жыл бұрын
No kidding 🤣 l
@markanders250
@markanders250 7 ай бұрын
Goodmans, that explains it all.
@coldflashac6443
@coldflashac6443 7 ай бұрын
Yup have you run into the new amanas and daikin ?
@zeke112964
@zeke112964 2 жыл бұрын
How long have you been an A/C tech?
@coldflashac6443
@coldflashac6443 2 жыл бұрын
5 years
@kingjames7929
@kingjames7929 2 жыл бұрын
Being a commercial tech.. what's the easiest best way to find out which unit is to what inside unit with no labels and multiple matching units throughout the building
@u2ooberboober
@u2ooberboober Жыл бұрын
Get a toner and hook up to the control wires.
@natashaburrell7615
@natashaburrell7615 Жыл бұрын
Man, you should have tried the hammer only first.
@coldflashac6443
@coldflashac6443 Жыл бұрын
I could but everything has a process of troubleshooting
@920PC
@920PC Жыл бұрын
@@coldflashac6443 and making 2 changes without testing in between changes leaves you guessing what change fixed the problem. I would guess that just the hammer trick would not have got this compressor spinning, it was the extra boost from the hard start kit. If it still didn't work I would try hitting it when its actively powered and trying to spin.
@SocratesDionisius
@SocratesDionisius 4 ай бұрын
What if we just put switch R & S on capacitor for a couple of second? Use capacitor that has more mikro farat?
@james10739
@james10739 Жыл бұрын
They way those compressors are inside the case I'm not sure tapping does much and honestly if it does I doubt a rubber mallet would do it and you are not hitting a new or good compressor
@procharger94
@procharger94 2 жыл бұрын
Excellent fix. I have a 5 ton Lennox from 2016 that will not start without a hard start kit.
@coldflashac6443
@coldflashac6443 2 жыл бұрын
Sometimes adding a crack case heater will help the compressor start when you have liquid freon migrating inside the compressor
@coldflashac6443
@coldflashac6443 2 жыл бұрын
Thanks for your comment ❤️👍
@jaykemm3472
@jaykemm3472 2 жыл бұрын
Good Work. Subd
@coldflashac6443
@coldflashac6443 2 жыл бұрын
Thanks for the sub!
@nomebear
@nomebear 2 жыл бұрын
Is the Goodman brand improved since Daikin purchased it? When it was Janitrol it had such a bad reputation.
@coldflashac6443
@coldflashac6443 2 жыл бұрын
I believe so , but amanas are good now days , you can even connect your phone
@muhammadyasir6780
@muhammadyasir6780 2 жыл бұрын
I wish we had these hard start kits in our country... i have 3 ACs with stuck comoressors and i have searched the country but no one has hard start kits
@coldflashac6443
@coldflashac6443 2 жыл бұрын
Wow , have you tried buying online ? Thanks for the comment 👍
@muhammadyasir6780
@muhammadyasir6780 2 жыл бұрын
@@coldflashac6443 i am from pakistan and amazon does not work here... there r some suppliers but they r mostly not reliable as i had tried once to buy something from them...
@coldflashac6443
@coldflashac6443 2 жыл бұрын
@@muhammadyasir6780 wow good luck man
@muhammadyasir6780
@muhammadyasir6780 2 жыл бұрын
@@coldflashac6443 thank u man... and i m gonna subscribe to ur channel... keep it up bro
@coldflashac6443
@coldflashac6443 2 жыл бұрын
@@muhammadyasir6780 🙏🏼thanks brother that means alot
@johnblaisdell2179
@johnblaisdell2179 2 жыл бұрын
Our shop has been installing Goodman for years. A factory tech support guy once told us that the factory wants you to field install a start kit
@coldflashac6443
@coldflashac6443 2 жыл бұрын
Good to know 🙏🏼
@Bear_83
@Bear_83 2 жыл бұрын
Just bought a house and same issuse. Blows warm air. Fan spins. Capacitor was swollen and rusted. Mechanic change out and still.warm air determine compressor is shot. But never did this test. May try this myself for atleast temporary fix. O got an 2010 ducane unit
@coldflashac6443
@coldflashac6443 2 жыл бұрын
👍 yea add a start kit capacitor and hit it , thanks for the comment
@Bear_83
@Bear_83 2 жыл бұрын
@@coldflashac6443 how would I find a compatible one. Even so how would I find a compatible capacitor since the mechanic took back the new one he put in.
@coldflashac6443
@coldflashac6443 2 жыл бұрын
@@Bear_83 the compressor sticker has the size of the cap and the fan sticker has de fan size cap , for the start kit buy an spp6 start kit on amazon
@Bear_83
@Bear_83 2 жыл бұрын
@@coldflashac6443 the stickers are faded barley got the model number which is zr32k3-pfv- all I got.
@coldflashac6443
@coldflashac6443 2 жыл бұрын
@@Bear_83 give me the model # and serial # of the whole unit
@redeye2629
@redeye2629 Жыл бұрын
Ah yeah scooter that’s not a package unit
@coldflashac6443
@coldflashac6443 Жыл бұрын
The inside unit is
@redeye2629
@redeye2629 Жыл бұрын
@@coldflashac6443 nope wrong again
@williamsoucy7334
@williamsoucy7334 2 жыл бұрын
Where is this in naples ?
@handduggraverdronline
@handduggraverdronline 2 жыл бұрын
It's called refrigerate
@thefreshride1510
@thefreshride1510 3 ай бұрын
I have not installed a hard star capacitor.
@javiercruz2241
@javiercruz2241 2 жыл бұрын
Say customer doesnt want you back
@coldflashac6443
@coldflashac6443 2 жыл бұрын
lol
@saidk1839
@saidk1839 2 жыл бұрын
ghost voltage
@coldflashac6443
@coldflashac6443 2 жыл бұрын
Thats what it looks like lol
@tejonBiker
@tejonBiker 2 жыл бұрын
Nice tip, some weeks ago I replaced a r22 9000 btu compressor that not want to start, I tried everything, only left smash with something, I have the compressor with me, I will try this and see if start.
@coldflashac6443
@coldflashac6443 2 жыл бұрын
Nice 👍 let me know if it works
@DJV94022
@DJV94022 7 ай бұрын
Has anyone else delt with the bad batch of lennox air handlers with stuck txvs? Well tapping it with the hammer gets em going. Seems like if you tap a txv, Compressors and reversing valve does temperary fixes. I know the txv being new itll work for ever The reversing valve 50/50 chance itll stay good or go out bad in the next heat/cool switch But the compressor tells you itll last another 6 months or so
@coldflashac6443
@coldflashac6443 6 ай бұрын
Yea the trick of the tapping magic lol , we changed this compressor already they waited 5 months
@coldflashac6443
@coldflashac6443 6 ай бұрын
A lot of techs braze with out nitrogen also they don’t remove the txv bulb while brazing thats why the fail
@julamellacaya3597
@julamellacaya3597 2 жыл бұрын
Good day Sir..... i won't to work in your company I'm ah ac aircon technician for almost 4yrs in Philippines 🙏🙏🙏
@Hikesay
@Hikesay Жыл бұрын
hat was this? Initially, you said the capacitor is completely dead, and then after a min you said capacitor is working good.
@lucymartinez7705
@lucymartinez7705 2 жыл бұрын
Please, come and fix mine. Financially struggling 😥
Top 5 Things AC Companies Don't Want You To Know How To Do!
12:40
How To Home
Рет қаралды 2,4 МЛН
Locked Compressors
20:13
HVAC School
Рет қаралды 118 М.
黑天使被操控了#short #angel #clown
00:40
Super Beauty team
Рет қаралды 61 МЛН
BAYGUYSTAN | 1 СЕРИЯ | bayGUYS
36:55
bayGUYS
Рет қаралды 1,9 МЛН
How To Diagnose A BAD Compressor | HVAC Troubleshooting
9:46
Quality HVACR
Рет қаралды 198 М.
Home A/C Compressor Not Running - Fixed
13:59
stuzman
Рет қаралды 411 М.
How I Troubleshoot an Air Conditioner Compressor
12:17
Fox Family Heating and Air Conditioning
Рет қаралды 311 М.
Central A/C Compressor Won't Start Up(Stuck/Momentary Hum )
12:16
electronicsNmore
Рет қаралды 360 М.
HVAC AC Compressor Locked Up ( LRA )
9:18
Word of Advice TV
Рет қаралды 122 М.
Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips!
27:56
AC Service Tech LLC
Рет қаралды 1,5 МЛН
AC Won't Start - How To Troubleshoot & Replace a Contactor - 1 Pole vs 2 Pole
15:46
Testing if an HVACR Compressor is Shorted to Ground, Open, or Overload Tripped!
11:06