Gas Training - Boiler Fault Finding - No Heat / No Hot Water Viva Training Academy Roy Fugler

  Рет қаралды 19,624

Allen Hart

Allen Hart

Күн бұрын

Пікірлер: 51
@avnishkumar9118
@avnishkumar9118 3 жыл бұрын
Great tip for gas valve fault finding!thanks Alan and Roy!looking forward for wiring fault finding. Thanks once again guys!
@ArifPolicewala
@ArifPolicewala 9 ай бұрын
Thank you Allen and Roy. Another accurate quality video❤
@liamtulett8249
@liamtulett8249 Жыл бұрын
These videos are really handy, well worth watching
@MrReza21azer
@MrReza21azer 3 жыл бұрын
Love these fault finding videos. Thank you 👌
@beggersu
@beggersu 7 күн бұрын
Great video Roy, thanks
@muhammadAli-kd2zp
@muhammadAli-kd2zp 3 жыл бұрын
Another great informative video Roy and Allan 👍👍
@paulrossiter9567
@paulrossiter9567 3 жыл бұрын
Loved this one 👏👏👏 brilliant work Roy from viva and Allen 👍 Looking forward to future vids. Water / air / gas / electric…..didn’t know what wage was before this …..can’t earn a wage without using this format 👍
@kosalaperera1899
@kosalaperera1899 2 жыл бұрын
Thank you Sirs, both Roy and Allen, really helpful as always. 100%.
@jademcmillan4672
@jademcmillan4672 Жыл бұрын
Great Video Guys. Keep them coming
@PlymouthSparky
@PlymouthSparky 3 жыл бұрын
Great Alan and Roy. Great video, hope to be up with you guys this year for some top training.
@zachrichardson4256
@zachrichardson4256 3 жыл бұрын
brilliant video! more of these please? roy is a great teacher👌🏼
@jameshawkins5280
@jameshawkins5280 3 жыл бұрын
Once again another great video keep them coming its priceless m8 top men the pair of you should both be given a knighthood not forgetting mr ideal and the other chap .
@paulgray7226
@paulgray7226 10 ай бұрын
Great video, thanks you
@jasonwhittle5008
@jasonwhittle5008 3 жыл бұрын
Great video lads 👍
@veronicahart450
@veronicahart450 3 жыл бұрын
Wonderful video
@richardhodgson7443
@richardhodgson7443 3 жыл бұрын
Very informative thank you 🙏
@plumbingwithbigphil6697
@plumbingwithbigphil6697 3 жыл бұрын
🔝 rewatching this later. Quality
@AllenHart999
@AllenHart999 3 жыл бұрын
Me names Danny 😩
@plumbingwithbigphil6697
@plumbingwithbigphil6697 3 жыл бұрын
@@AllenHart999 😅😅😂😂 mi names Allen hart
@rayc1503
@rayc1503 3 жыл бұрын
You guys are Gold, really useful information team 👍.
@plumbertime
@plumbertime 3 жыл бұрын
Back voltage on a Worcester who’d of thought it! 😂 Lovely job. What affects the air integrity test. Obviously seals ect but hear height can reduce the oxygen level Just to add I’m pretty good at my job but always looking for tips like any half decent engineer would be. I’m sure lots of experienced guys watch your stuff!
@manjsingh6500
@manjsingh6500 3 жыл бұрын
Great. Video. Top man Roy
@lukehodges4511
@lukehodges4511 3 жыл бұрын
Good stuff
@kuldipkaurkalsi923
@kuldipkaurkalsi923 2 жыл бұрын
Good information
@Benji-gq9gx
@Benji-gq9gx Ай бұрын
After replacing the gas valve you could tightness test and this would show you your inlet connection to valve is sealed and tight but this wouldn't work on the outlet as valve would be shut? Is that correct? If so is ldf the only way to check the outlet connection on gas valve?
@michaelorourke3997
@michaelorourke3997 3 жыл бұрын
Terrific video as always. Just a couple of questions, could you not have just changed the solenoid and my other question is when I change a gas valve on a Vokera I have to adjust the gas valve in high and low fire but not here? Thanks
@royfugler9971
@royfugler9971 3 жыл бұрын
Hi Michael, Thanks for the feedback. Unfortunately the solenoid isn't available as a spare part, Worcester gas valve comes factory set, so just a case of checking to make sure it's within tolerance. Baxi use a similar SIT valve and they need adjusting the same as Vokera.
@michaelorourke3997
@michaelorourke3997 3 жыл бұрын
@@royfugler9971 thanks Roy.
@Stevenb77
@Stevenb77 3 жыл бұрын
On a couple services for Worcester greenstar boilers, after I turn the gas off to check the flame failure device. An fo 238 internal error code comes on the boiler screen. To my understanding a new gas valve is required after some check, how can turning the gas off break the gas valve?
@davidb2464
@davidb2464 3 жыл бұрын
Hello Roy, Excellent vid, where did you get those gas connection plugs on your hose, they look great?
@brubeker12
@brubeker12 Жыл бұрын
My worcester bosch system boiler keeps dropping out ,it will, reboot using the manual dial control but what should I boiler engineer be checking
@stephenwilliams1854
@stephenwilliams1854 2 жыл бұрын
Could you do a video on how to wire up a regular (heat only) boiler with pump overrun when replacing an older boiler without pump overrun with a newer condensing boiler.
@sudhiradhikari19
@sudhiradhikari19 3 жыл бұрын
Hi Alan, at last, Roy said he will do video on wiring unvented cylinder and s plan, is there video done for it, if there is can you please put me the link.
@mikerussell1765
@mikerussell1765 2 жыл бұрын
Hi Roy I've had a fault come up on my baxi compact 163 can't find what it is any idea's plz
@PlatinumEmergency
@PlatinumEmergency 3 жыл бұрын
Where did you guys get the solid P1 connector for your gas analyser please??
@WEYHARRY1
@WEYHARRY1 3 жыл бұрын
What is the extension called on your manometer
@sentemir3183
@sentemir3183 3 жыл бұрын
👏👏👏👏👏
@TomPalacki
@TomPalacki 3 жыл бұрын
👍
@neilbirkett835
@neilbirkett835 3 жыл бұрын
I'm sure just seen roy in whitby,wasn't sure, or would av bought u a few beers buddy.
@AllenHart999
@AllenHart999 3 жыл бұрын
Yes that was him 😀
@brethren4life152
@brethren4life152 10 ай бұрын
baxi duo-tec still the best boiler.
@Noname-k5o1n
@Noname-k5o1n 3 жыл бұрын
What would you charge the customer for such a job in the real world?
@alondon9421
@alondon9421 3 жыл бұрын
Is no drop after ignition not enough reason to proof gas valve need replacing ? Or testing solenoid is crucial as well on this case ?
@kevincranfield5235
@kevincranfield5235 3 жыл бұрын
Not at all, you could have a faulty wiring harness and by assuming it’s the valve will make you look foolish.
@alondon9421
@alondon9421 3 жыл бұрын
@@kevincranfield5235 so basically testing by multimeter is just checking the harness too from PCB ?
@kevincranfield5235
@kevincranfield5235 3 жыл бұрын
A blocked condensate trap backing up into the sump will cause resistance on the fan, which in turn cannot lift the valve seating and therefore no drop on the gauge. Never never assume without proper testing.
@ElTelBaby
@ElTelBaby 3 жыл бұрын
ROFL The thumb nail kind'a gave it away... WAGE = Water Air Gas Electric
風船をキャッチしろ!🎈 Balloon catch Challenges
00:57
はじめしゃちょー(hajime)
Рет қаралды 100 МЛН
coco在求救? #小丑 #天使 #shorts
00:29
好人小丑
Рет қаралды 18 МЛН
Gas Training - Boiler Fault Finding - No Hot Water - Roy Fugler
23:43
How Did British Gas Miss This Simple Fault?
6:32
Skill Builder
Рет қаралды 126 М.
BOILER KEEPS LOSING PRESSURE - WHY AND HOW TO FIX - Plumbing tips
9:13
plumberparts
Рет қаралды 2,1 МЛН
Plumbers from hell left this behind
14:56
Urban Plumbers
Рет қаралды 77 М.
How much does a Plumber Cost?? Day in the life of a Plumber EP8
24:02
Blue Bulldog Plumbing
Рет қаралды 11 М.