Great tip for gas valve fault finding!thanks Alan and Roy!looking forward for wiring fault finding. Thanks once again guys!
@ArifPolicewala9 ай бұрын
Thank you Allen and Roy. Another accurate quality video❤
@liamtulett8249 Жыл бұрын
These videos are really handy, well worth watching
@MrReza21azer3 жыл бұрын
Love these fault finding videos. Thank you 👌
@beggersu7 күн бұрын
Great video Roy, thanks
@muhammadAli-kd2zp3 жыл бұрын
Another great informative video Roy and Allan 👍👍
@paulrossiter95673 жыл бұрын
Loved this one 👏👏👏 brilliant work Roy from viva and Allen 👍 Looking forward to future vids. Water / air / gas / electric…..didn’t know what wage was before this …..can’t earn a wage without using this format 👍
@kosalaperera18992 жыл бұрын
Thank you Sirs, both Roy and Allen, really helpful as always. 100%.
@jademcmillan4672 Жыл бұрын
Great Video Guys. Keep them coming
@PlymouthSparky3 жыл бұрын
Great Alan and Roy. Great video, hope to be up with you guys this year for some top training.
@zachrichardson42563 жыл бұрын
brilliant video! more of these please? roy is a great teacher👌🏼
@jameshawkins52803 жыл бұрын
Once again another great video keep them coming its priceless m8 top men the pair of you should both be given a knighthood not forgetting mr ideal and the other chap .
@paulgray722610 ай бұрын
Great video, thanks you
@jasonwhittle50083 жыл бұрын
Great video lads 👍
@veronicahart4503 жыл бұрын
Wonderful video
@richardhodgson74433 жыл бұрын
Very informative thank you 🙏
@plumbingwithbigphil66973 жыл бұрын
🔝 rewatching this later. Quality
@AllenHart9993 жыл бұрын
Me names Danny 😩
@plumbingwithbigphil66973 жыл бұрын
@@AllenHart999 😅😅😂😂 mi names Allen hart
@rayc15033 жыл бұрын
You guys are Gold, really useful information team 👍.
@plumbertime3 жыл бұрын
Back voltage on a Worcester who’d of thought it! 😂 Lovely job. What affects the air integrity test. Obviously seals ect but hear height can reduce the oxygen level Just to add I’m pretty good at my job but always looking for tips like any half decent engineer would be. I’m sure lots of experienced guys watch your stuff!
@manjsingh65003 жыл бұрын
Great. Video. Top man Roy
@lukehodges45113 жыл бұрын
Good stuff
@kuldipkaurkalsi9232 жыл бұрын
Good information
@Benji-gq9gxАй бұрын
After replacing the gas valve you could tightness test and this would show you your inlet connection to valve is sealed and tight but this wouldn't work on the outlet as valve would be shut? Is that correct? If so is ldf the only way to check the outlet connection on gas valve?
@michaelorourke39973 жыл бұрын
Terrific video as always. Just a couple of questions, could you not have just changed the solenoid and my other question is when I change a gas valve on a Vokera I have to adjust the gas valve in high and low fire but not here? Thanks
@royfugler99713 жыл бұрын
Hi Michael, Thanks for the feedback. Unfortunately the solenoid isn't available as a spare part, Worcester gas valve comes factory set, so just a case of checking to make sure it's within tolerance. Baxi use a similar SIT valve and they need adjusting the same as Vokera.
@michaelorourke39973 жыл бұрын
@@royfugler9971 thanks Roy.
@Stevenb773 жыл бұрын
On a couple services for Worcester greenstar boilers, after I turn the gas off to check the flame failure device. An fo 238 internal error code comes on the boiler screen. To my understanding a new gas valve is required after some check, how can turning the gas off break the gas valve?
@davidb24643 жыл бұрын
Hello Roy, Excellent vid, where did you get those gas connection plugs on your hose, they look great?
@brubeker12 Жыл бұрын
My worcester bosch system boiler keeps dropping out ,it will, reboot using the manual dial control but what should I boiler engineer be checking
@stephenwilliams18542 жыл бұрын
Could you do a video on how to wire up a regular (heat only) boiler with pump overrun when replacing an older boiler without pump overrun with a newer condensing boiler.
@sudhiradhikari193 жыл бұрын
Hi Alan, at last, Roy said he will do video on wiring unvented cylinder and s plan, is there video done for it, if there is can you please put me the link.
@mikerussell17652 жыл бұрын
Hi Roy I've had a fault come up on my baxi compact 163 can't find what it is any idea's plz
@PlatinumEmergency3 жыл бұрын
Where did you guys get the solid P1 connector for your gas analyser please??
@WEYHARRY13 жыл бұрын
What is the extension called on your manometer
@sentemir31833 жыл бұрын
👏👏👏👏👏
@TomPalacki3 жыл бұрын
👍
@neilbirkett8353 жыл бұрын
I'm sure just seen roy in whitby,wasn't sure, or would av bought u a few beers buddy.
@AllenHart9993 жыл бұрын
Yes that was him 😀
@brethren4life15210 ай бұрын
baxi duo-tec still the best boiler.
@Noname-k5o1n3 жыл бұрын
What would you charge the customer for such a job in the real world?
@alondon94213 жыл бұрын
Is no drop after ignition not enough reason to proof gas valve need replacing ? Or testing solenoid is crucial as well on this case ?
@kevincranfield52353 жыл бұрын
Not at all, you could have a faulty wiring harness and by assuming it’s the valve will make you look foolish.
@alondon94213 жыл бұрын
@@kevincranfield5235 so basically testing by multimeter is just checking the harness too from PCB ?
@kevincranfield52353 жыл бұрын
A blocked condensate trap backing up into the sump will cause resistance on the fan, which in turn cannot lift the valve seating and therefore no drop on the gauge. Never never assume without proper testing.
@ElTelBaby3 жыл бұрын
ROFL The thumb nail kind'a gave it away... WAGE = Water Air Gas Electric