Hi Kevin These videos are fantastic, the illustrations are brilliant, your an absolute goldmine of knowledge on ideal boilers please keep them coming, John Heating Engineer from Dublin. 😍
@andyfadian2 жыл бұрын
Big thanks to Kevin, please keep these Ideal videos coming, great top tip to start with. Cheers Allen
@neilgerrard4469 Жыл бұрын
Brilliant info as usual.from Kevin, more and more please
@steveincork36692 жыл бұрын
Had a F2 fault on that generation boiler a few months ago. Boiler would light but go out. I did all usual checks gas vavle injector venturi cleaned heat exchanger checked flue and condensate but not sorted. I just did a training course with Ideal a few days ago and we were instructed to do a resistance check in the spark generator in megaohms. I was unaware of this at the time of break down but the Ideal trainer told me that unlike the next 2 generations of logics the flame rectification was tied in with this particular 2009 model combi's spark generator. Totally surprised me because the boiler would ignite but as i found out it did so with a fault included in with spark generator. You live and learn i suppose what made it worse was that it was located in a busy hair salon. One thing that i find with the Ideal logic installer and servicing manual is ther are no part numbers included in the parts legend page?. Great videos Alan kevin👍👍👍
@elwittinio28652 жыл бұрын
Had this on a Remeha Quinta pro. Worked fine then an hour or too later ignition issues. Tested fine when cold but ignition transformer bolted to side of exchanger, not great 😀
@lukeclarke17432 жыл бұрын
Would love to see more videos Kevin , have watched everyone you have sent to Allen and love how you give so much detail that I really learn a lot every time . Much appreciated
@raul8352 жыл бұрын
Brilliant vid.. detailed explanation as usual from Kevin.
@jameshawkins52802 жыл бұрын
Thanks another great video to add to my collection from Mr ideal .thanks allen keep them coming.
@riazulkhalil6878 Жыл бұрын
Hi burner not fire we did all you show in your video same modal gas pipe not open but when we reset burner on few sce than off do you know what is the problem pls help
@AllenHart999 Жыл бұрын
You need to call a Plumber or Gas Safe Engineer. Thanks.
@nickcannon55922 жыл бұрын
If you can do more stuff about logics because you have got me bang out of trouble on more than one occasion, thank you kev
@veniamindoychev619911 ай бұрын
Another possible cause for a blank display could be a water damaged flow turbine sensor.
@andrewallen2903 ай бұрын
Didnt mention how to address the root cause, which was how to stop water ingress from the air intake. Any ideas?
@engjds11 ай бұрын
Hi what if the display is lit, but the boiler doesnt ignite? no blue light is showing any more and no heating.
@jacko28154 ай бұрын
Could be loads of things. Need to check pump running fan gas valve ect
@darrenclarke1612 жыл бұрын
Great tip thanks guys .👍😁
@claudiamarien43482 ай бұрын
I’m having issues getting my ideal boiler to run the hot water independently, I don’t know if I’m doing anything wrong. I’m setting the thermostate to were it clicks 😢 heating works just fine any ideas ( I had a gas service guy here today but I turned the thermostat off again and no hot water will kick in again)
@efrygasservices61692 жыл бұрын
More great advice 👍
@AllenHart9992 жыл бұрын
Thank you sir. Hope you are well.
@taylerhogan59332 жыл бұрын
Great video! Really helpful 👍 Keep them coming please!
@CravenJB Жыл бұрын
How to fix ignition lockout please 🙏
@john-paulcox9182 жыл бұрын
Great video. Well done guys .
@LeaWilliams-t8mАй бұрын
Why is L2 coming up on the boiler
@elwittinio28652 жыл бұрын
Had a few exchangers go lately, one was an ideal mini 4 years old. System was nice and clean too. Seems to be the weak part on these.
@johnburns40172 жыл бұрын
In general, find heat exchngers last longer when weather compensation is connected. The heat exchanger operates at a lower temperature most of the time.
@raul8352 жыл бұрын
Definitely want to see lots more from you Kevin pls.
@gedmcnamara9082 Жыл бұрын
Is it possible to change the fuse to save the board ?
@grahambristol2988 Жыл бұрын
Obvious question and typically not addressed in the video. Also these guys never answer questions raised in the comments.
@jacko28154 ай бұрын
@@grahambristol2988generally no
@slichannel2252 жыл бұрын
I have Alpha intec 28x boiler. And is no heating now...can you help me please? Water is working well
@SuperTrooper90002 жыл бұрын
Thanks Kevin and Allen, very informative videos. I've came across a few logics that have a howl/wailing noise which appears from the venturi area, sometimes helped with venturi cleaning out but not always and often intermittent with no fault codes. Do have any tips on identifying the cause?
@kevincranfield52352 жыл бұрын
Will be a dirty injector or gas valve issue. Go for injector first. If you can’t clean it. Replace it
@Lutonman20102 жыл бұрын
Ive done a few of these faults. In every case if the boiler/fan/venturi are clean then its been the gas valve, particularly bad when on low rate, sometimes leading to a flame loss error due to the unstable flame. They can rumble like crazy on low rate.
@NatalieCallaghan Жыл бұрын
We have the Logic+S18 and the hot water isn't working independently. It does however work if the heating is on? What do you think could be the problem. I have searched videos but the closest I got was thinking it may be the turbine cartridge - could you help?
@AllenHart999 Жыл бұрын
Zone valve faulty, Might be dirt in the system
@davidspencer89682 жыл бұрын
Thanks Kevin, great stuff
@gleceriojontillajr.3463 Жыл бұрын
Why is it i cannot twist my Blue Switch to turn up the Pressure?
@AllenHart999 Жыл бұрын
Thank You
@johnburns40172 жыл бұрын
Unsoldering the fuse and inserting a new one is not a great task and would save a lot of money on a new pcb. What size is it, and where are they available? Most probably available in any electronics shop. Bad design in that they do not have a replaceable cartridge fuse. In fact a fuse carrier and replaceable cartridge fuse could be soldered in. Two wires soldered in, with an inline fuse carrier.
@kevincranfield52352 жыл бұрын
It’s not just the fuse. You still need the harness and transducer. At a manufacturer level, we don’t repair as a replacement is a much more reliable repair. But I agree with you that if you have the expertise then replacing the fuse is much cheaper. However I bet most plumbers won’t.
@johnburns40172 жыл бұрын
@@kevincranfield5235 Kevin, I am aware the harness and transducer needs to be bought. But the heavy expense of a new pcb can be avoided for a small cost and and 15 mins of time. If the fault reoccurs or other fault blowing the LV fuse, the fuse can be easily replaced. I do have the skills to unsolder a component on a pcb. ;) In fact most plumbers could do it using a soldering iron and long nosed pliers to pull the ends on the fuse out one by one. Or in this case cut out the fuse, then solder the fuse holder"s wires to the lugs sticking out you used to do the test with the meter. BTW, a place in Watford, CET LTD, does reconditioned exchange pcb's. Inc' Logics. Cheaper than a new one.
@ciaransheen3883 Жыл бұрын
Hi Kevin, I had this fault today, low voltage fuse blown, green stain on transducer. Cleaned up connections on harnesses and transducer with oil spray. Replaced pcb and everything works OK. Made a jacket for the transducer with insulation tape. Thanks for the video
@johnburns4017 Жыл бұрын
@@ciaransheen3883 Oil spray? If water drips on the transducer again, the fuse will blow again.
@olliebodman9771 Жыл бұрын
I have an ideal and the other day my boiler was serviced, since then I turned the heating on and it went straight to 4 bar pressure in 5 mins Plus I’ve started losing pressure gradually, over the past months the pressure has always been bad and I’ve had to refill
@toneskill2 жыл бұрын
I had a problem with mine. When showering going hot and warm. Changed the plate heat exchanger. Put it back together no leaks. But now saying F4 fault. Tried reset no joy a neighbour had a gas engineer come over he said might be 127 or 128 sensor. Any ideas
@toneskill2 жыл бұрын
All fixed flow turbine and knock a flow sensor. God iam good
@deln69362 жыл бұрын
Ideal logic heat 18 hw off ch off room stat off micro switches on zone valves not stuck but boiler continues to fire any idea's appreciated
@JasonThompson-y5s5 ай бұрын
Great video
@jasonwhittle50082 жыл бұрын
Very similar to Glowworm cxi old pressure sensor would make screen blank 👍👍
@parveenmasud38132 жыл бұрын
What's the problem when it show2l
@tonykyle52292 жыл бұрын
Hi Kevin, I have a logic that makes a rumble sound only on first fire, then it's ok? I've flushed the heat exchanger, checked the burner and condensate, still does it.... only on it's first ignition sequence, any ideas? Gas rate and combustion readings are fine.
@kevincranfield52352 жыл бұрын
Is it not under warranty?
@Lutonman20102 жыл бұрын
almost certainly the gas valve. its a known issue. Put it in service mode low rate and if it rumbles then change the gas valve. hope this helps
@kevincranfield52352 жыл бұрын
If it’s the 24v Honeywell gas valve, then it is quite possible as there is a small white plastic cap inside which regulates the throttle on minimum fire which sticks. It allows too much oxygen and not enough gas to flow and therefore the flame extinguishes and try’s to relight itself on the burner which creates the sound. If it is an older model with a different valve then it could be the injector or flue seal etc etc. hard to say without being there.
@tonykyle52292 жыл бұрын
Not under warranty, I've had it before and changed gas valve, still the same and it's the 240V valve? I've had it before on the 24v valves and it's sorted it, bit not this time, like I say it only happens on first fire
@kevincranfield52352 жыл бұрын
Have you replaced the injector?
@KiangafАй бұрын
The biggest issue I get by far on that model is the gas valve.
@HH-H-H8 ай бұрын
Engineer is a big word for someone repairs boilers a car is more complicated then boiler 😂😂😂😂😂
@gbwildlifeuk826911 ай бұрын
This video needs a new title from: common faults ideal boiler to : ONE electrical fault because thats all the ramble was about! 👎👎👎👎
@SuperWayneyb2 жыл бұрын
🤘😎🤘
@vanillagoose4444 Жыл бұрын
1 fault on an old machine WTF 😂
@brendaasquith96162 жыл бұрын
Pump overrun
@anthonygreenwood4486 Жыл бұрын
No wonder ideal don’t want anything to do with him
@daz3745 Жыл бұрын
Why?
@janetwelch85362 жыл бұрын