Thanks , big help repairing American Standard Flush Valves for 1st time!
@AmreSupply2 жыл бұрын
You're welcome, we're just happy to help!
@andresmayen55793 жыл бұрын
Hi, thanks for your video, i`m very happy because have subtitles in spanish, this is good for me. Thank u!
@AmreSupply3 жыл бұрын
You're welcome!
@valentinevega70902 жыл бұрын
So i tightened the bonnet nut down on to the piston and once I started to open , valve, water begins to fill pipe . I push manual valve and water begins to make it past piston in solenoid housing .Bad manual valve ? Not tight enough on bonnet nut ? I checked solenoid and its good , makes a click noise . Help would be appreciated .
@AmreSupply2 жыл бұрын
Thanks for watching. It is possible that the piston is not seated properly in the valve. It would be worth removing it, checking to see if there is any corrosion or mineral buildup in the valve and threads and reinstalling the piston.
@davidhunter13582 жыл бұрын
will a malfunctioning piston create water hammer?
@AmreSupply2 жыл бұрын
Thanks for watching. It is possible though the piston is not as likely as a source of water hammer as compared to a pure solenoid valve like in a washing machine. Solenoid water valves are more instant in how they open and close. (Keep in mind the solenoid used in these flushometers only opens the bypass) You could check the rubber seals to see if they are sticking. In an ideal scenario, the seals should be tight but not sticking or preventing movement.
@michaelmunoz10072 жыл бұрын
WHat are these part #s and where are they listed in your catalog
@AmreSupply2 жыл бұрын
Thanks for watching. The best way of narrowing down the part number is to find the part sheet for your model like this one: www.amresupply.com/part/11203082 If you scroll to the bottom you'll find a few PDF's. Keep in mind there is some variation between models, like this one with a 10 year battery has a different piston and solenoid: www.amresupply.com/part/6066721-002-AmericanStandard-WC-Flush-Valve-10YR-Battery For example: M962907-0070A Is a common piston for urinal flushometers: www.amresupply.com/part/19508278?replaces=M962907-0070A
@maynardbumagat29802 жыл бұрын
what would cause the urinals to not flush? the solenoid makes a click sound but does not flush... manual flush works
@AmreSupply2 жыл бұрын
There is one more thing to consider. A mineral buildup might prevent water from flowing when the solenoid opens. It would be good to open up the valve and try inspecting the piston and solenoid. Make sure that nothing is blocking the path between the two.
@freddybecerra3972 жыл бұрын
How did you replaced The battery
@AmreSupply2 жыл бұрын
Thanks for watching. The battery can be replaced by following the steps in this video: kzbin.info/www/bejne/fIjMqJyQhNWno6M
@gordissibling81343 ай бұрын
What if I don’t have the Litte screw?
@AmreSupply3 ай бұрын
Thanks for watching. Do you mean there is no set screw on the back cover?
@shaikkareem11426 жыл бұрын
Hi sir u have mor vdos please sand me please
@AmreSupply6 жыл бұрын
Hi Shaik, if you are interested in watching more videos please explore our channel kzbin.info For more flushometer repairs, there are 80 videos in these playlists kzbin.info/playlists?shelf_id=11&view=50&sort=dd