@LoveYourRV Жыл бұрын
*Link to Previous Review Video* - www.loveyourrv.com/demos-review-ampere-time-12v-200ah-self-heating-lithium-battery/ LiTime Website - www.litime.com/discount/RAYBURR?ref=_J5LoyeHGgAJiK
@amperetimemarketing7931
@amperetimemarketing7931 Жыл бұрын
I am sorry to hear this information. Please note that the battery BMS board of the Ampere Time 12V200Ah heating model is 100A and can withstand a load of 1280W. If the load exceeds, the protection function is triggered. It can be checked if it is because of this factor. In addition, Li for LiTime means Lithium, pronounced lee.
@LoveYourRV
@LoveYourRV Жыл бұрын
The loads I tested in the video were no load just the inverter idle wattage, 50 watt fan and 600 watt heater. All fail to be powered. Battery would shutdown.
@LoveYourRV
@LoveYourRV Жыл бұрын
Tested the inverter inrush current today with my clamp on amp meter. Average was about 60 amps. Max test was 86 amps. The battery has a 300 amp surge rating on the BMS
@williamschuman4951
@williamschuman4951 Жыл бұрын
Glad you’re on your the front line for product testing, it means a lot for the rest of us.
@billdennis2993
@billdennis2993 Жыл бұрын
Thx Ray for keeping these Company's feet to the fire when they produce products that don't perform as advertised. Stay Healthy.
@lesbollinger7099
@lesbollinger7099 Жыл бұрын
Thanks for the update your knowledge and testing is very useful when looking to expand or replace equipment look forward to how customer service responds and final determination
@alberteller7286
@alberteller7286 Жыл бұрын
Thanks Ray that was very interesting. It’s good to have people like you telling us what you find on this new world. Thank you.
@todddunn945
@todddunn945 Жыл бұрын
Inverters often have a fairly large capacitor bank on the input stage. When you turn the inverter on the first thing that happens is the capacitor bank charges. That happens very quickly and can generate a very large, but short duration amp draw on your battery. If that amp draw is big enough it can trip the over current protection in the batteries BMS. That over current trip can be reset by letting the battery sit without load for some time (often around 30 seconds) or by applying a voltage above some threshold, typically above 14V, which your charger does. From what I can tell, that particular Ampere Time battery has a 100 amp BMS and it appears that your 1500 watt inverter simple draws enough current for a few milliseconds at start up to trip the BMS over current protection. That the same thing doesn't happen with the Chins battery says that it has a different over current protection limit/time combination. It appears to me that the battery is working as designed. If you want to learn more about your battery, may I suggest this video from Lithium Solar - kzbin.info/www/bejne/g6uqf2yaZbiVb6c . Watch to the end where he talks about having exactly the same issue you are having. What it comes down to is that you are trying to run too large an inverter with that battery. Your 1,000 watt inverter obviously has a smaller capacitor bank and doesn't draw a big enough surge on startup to shut down the battery. Also, with a 100 amp BMS that battery can only support a 1,000 watt inverter. A 1500 watt inverter, assuming 1,500 watts is its output capacity, can draw as much at 1,650-1,700 watts from the battery, which is around 130 amps, which a battery with a 100 amp BMS can not support. If you want to reliably run a 1,500 watt inverter, you really need a battery with a 200 amp BMS or two batteries with 100 amp BMS in parallel. Also, if you watch some of Will Prouse' KZbin older videos (www.youtube.com/@WillProwse), you will notice that he uses a power resistor to charge the inverter's capacitor bank before making the connection to the inverter. He does that to limit the surge current draw on the battery to prevent having the over protection trip.
@LoveYourRV
@LoveYourRV Жыл бұрын
Good guess, but it has done the same intermittently on DC loads that aren't even inverters. Just seems to be very repeatable with this inverter, so able to demo the issue with it. The loads I tested in the video were no load, just the inverter turning on via its power switch with nothing plugged in, so just idle current after startup and powering a 50 watt fan and 600 watt heater. All failed to be powered. The battery would shut down. As far as this inverter being a problem. The company looked closely at the video and feels it's likely faulty BMS. They did not blame the inverter for being too big. I used a 3000W inverter to do a load test in my review, and it worked fine to test for the rated 100 amp discharge capability. Something since then has gone awry. Makes me think they have a known issue. Also, the battery BMS has a Max. Discharge Current 5 Seconds: 280A rating. Highly unlikely the inverter would draw more than 280 amps by simply turning it, or it would be blowing people's inverter fuses all the time. They are sending out a new battery to test. btw Out of interest I tested the inrush current with my clamp-on amp meter. The average was about 60 amps. The max tested was 86 amps. I'll update when I get the new battery and try it. Judging by the feedback I'm getting, this battery BMS has had the same issue for several people requiring replacement to be sent out.
@LoveYourRV
@LoveYourRV Жыл бұрын
Here is a second video more clearly demoing what I'm seeing kzbin.info/www/bejne/fnrMdqxreNJ9f9E
@mja3514c
@mja3514c 4 ай бұрын
My battery does the exact same thing I took any load up to it. 1 watt or 100…same outcome.
@ve7cbh
@ve7cbh Жыл бұрын
Hi Ray I purchased 2x 300AH batteries from ampere Time and had BMS issues with both of them. Ampere Time worked with me and in the end paid for the batteries return and sent me new ones that work just fine. While it sucked to go through that process I give the vender a lot of credit for standing behind the product and ensuring that in the end I was a happy customer.
@LoveYourRV
@LoveYourRV Жыл бұрын
That's great to hear!
@standingmannequin7911
@standingmannequin7911 Жыл бұрын
I've been going two years almost full time with the Ampere Time 100AH batteries and have had no issues. I have separate heaters.
@projet2907
@projet2907 Жыл бұрын
Thank you for this review and testing. Always interesting and useful. Can't wait to follow what's up with it.
@michelleneely203
@michelleneely203 Жыл бұрын
We have the same battery and had the same issue. Kept tripping the BMS everytime we turned our Xantrex 2000 watt inverter on after alot of trial and error, we added an extra 2 oo cable from the battery to the inverter. piggy backed on to the existing cable, essentially doubling the wire size. that was 3 months ago and we have not had any issue since.
@LoveYourRV
@LoveYourRV Жыл бұрын
I wonder if the inverter was the shutting down from low voltage vs the battery BMS. That would make sense to me as to why increasing the wire gauge would solve the problem by reducing the voltage drop between the battery and inverter.
@mrc1539
@mrc1539 Жыл бұрын
Wow, you definitely got a head scratcher there Ray . Technology is great when it’s working but can sure be a nightmare when it’s not .
@MikeJordanUnCamplicated
@MikeJordanUnCamplicated Жыл бұрын
I just saw a guy on one of the RV forums complaining about a very similar condition. But I'm on way to many of them to remember which now.
@danielgjb
@danielgjb Жыл бұрын
I had a similar issue. The problem is when a large enough load is put on the battery at startup the voltage will drop below 11,5 volts so the inverter will shut itself off. If the inverter you are using has an adjustment for low voltage shut off and can be set to 10.5 volts you will not have any issues.
@LoveYourRV
@LoveYourRV Жыл бұрын
Thanks but that isn't the problem here. Its not an inverter low voltage shutdown issue. Its the battery internal BMS board shutting off current flow.
@davidtotten618
@davidtotten618 Жыл бұрын
I had a problem like this with an older Renolgy battery, ( as soon as the warranty expired, of course) only it it would turn on and off very rhythmically every for seconds. Never found the cause.
@coreymerritt7742
@coreymerritt7742 Жыл бұрын
Your right ray bad bms
@rvboondocker2559
@rvboondocker2559 Жыл бұрын
Some people don’t like reviews, but I think they’re extremely informative! Thanks a lot! I love your channel! It is always so fun to watch your videos! I am selling my Airstream Interstate, 19 4 x 4, and it’s listed on my channel if anybody is interested. Don’t worry, I will still watch your channel! I am getting something just a little bit bigger, but It has 525 Amp/hr Lithium by Lithionics. Literally bulletproof.
@hammer-r
@hammer-r 2 ай бұрын
Well I seem to have a similar issue with the same battery except mine doesn’t have the heater built in. Mine are 3 years old. I have two of them in parallel and charged by four 200 watt solar panels on an RV. Worked fine for the last three years for the couple months per year we needed them. But 10 days ago, they crapped out under Normal load of a small RV heater. Now we are trying to figure out why. I’m currently in contact with Amperetime and see what we can do. But really not very happy after spending $1500 for both of them. Let’s see what their tech says and what the warranty is. Tks for the video. Seems to confirm my issues.
@LoveYourRV
@LoveYourRV 2 ай бұрын
Thanks for sharing, I hope the do something for you. Cheers, Ray
@Google123ABC
@Google123ABC Ай бұрын
What was the problem? I have 2-230ah in parallel and only have a WiFi router connected to a 1000 watt inverter. Every night my inverter cuts off even though my battery bank still has 90 percent charge.
@LoveYourRV
@LoveYourRV Ай бұрын
@@Google123ABC Looks like my issue was a faulty BMS board. They sent me a replacement battery, and it worked. Here is the update video kzbin.info/www/bejne/rJfQZ3-MlrGnhZI
@Windkisssed
@Windkisssed Жыл бұрын
That IS very interesting!!! You certainly put it through the gamut!! I wouldn't rest easy until I could figure it out!! But it may not have a solution at the user level. Perhaps they'll dismantle it and find a solution. Thank you for your information & inspiration!!
@LoveYourRV
@LoveYourRV Жыл бұрын
I have a new update if your interested kzbin.info/www/bejne/rJfQZ3-MlrGnhZI They sent me a new replacement battery to test.
@JimNobles-gv4ky
@JimNobles-gv4ky Жыл бұрын
Great video for a non-battery scientist.
@Roll2Videos
@Roll2Videos Жыл бұрын
I've had issues with that inverter not working with different batteries. It wouldn't work with the Drprepare 100Ah but then work with the relibatt 100Ah. Keep testing the inverter.
@LoveYourRV
@LoveYourRV Жыл бұрын
The battery has not worked on other 12V loads besides the inverter. When I first noticed the battery shutting down it wasn't hooked to this inverter but rather my regular RV DC circuits which run a different inverter. This inverter though is very repeatable so made for an easy thing to test it with. Cheers, Ray
@Roll2Videos
@Roll2Videos Жыл бұрын
@@LoveYourRV That sucks; I just had a Chins battery fail on me (Video on my channel). Cheers, Roland.
@davidaube8381
@davidaube8381 Жыл бұрын
Have you checked how many amps the inverter draws when turned on. Those batteries have a 100 amp cut off built into the bms. Highly likely the bms is bad, but it can’t hurt to check.
@LoveYourRV
@LoveYourRV Жыл бұрын
It has the same 100 amps rating as pretty well every other battery I've tested the inverter on, and it works fine on them. Also, most BMS have a surge rating of 200 - 300 amps.
@LoveYourRV
@LoveYourRV Жыл бұрын
Tested the inrush current today with my clamp on amp meter. Average was about 60 amps. Max test was 86 amps. The battery has a 300 amp surge rating on the BMS
@davidcarrion3864
@davidcarrion3864 Жыл бұрын
I am on my second pair of these batteries. My first set had nearly the exact same problem. At random times while under load, they would momentarily drop voltage causing all of my RV equipment to reset. The voltage drop would only last 1-2 seconds but it was a real problem for my RV equipment. Another randomly occurring problem I encountered with the first set was when I'd turn off my generator the batteries would not provide any 12v power. The only way I found to correct it was to restart my generator for a few seconds. I assume doing so caused the BMS to reset and only then would they provide any power at all. It took several emails through their customer service department to finally get them replaced. Ultimately, I submitted a video like this one showing the voltage drop before they finally agreed to replace them. Luckily, my replacement batteries have functioned properly since installing them in Feb 2023.
@LoveYourRV
@LoveYourRV Жыл бұрын
Thanks for letting us know. They sent a replacement that solved the battery shutdown problem I was having. kzbin.info/www/bejne/rJfQZ3-MlrGnhZI Cheers, Ray
@jab376
@jab376 5 ай бұрын
@@LoveYourRV Did you do an installation and testing video of battery replacement amperetime sent you? It would have been nice update to the issues you faced and educational to your audience.
@LoveYourRV
@LoveYourRV 5 ай бұрын
@@jab376@jab376 I used the replacement for a while in my truck toolbox test bed with the original, and with two in parallel, they worked OK in that arrangement kzbin.info/www/bejne/sKWsioh9e7aiqKc I've since given them away as I had other batteries to test. Tested a SOK for a while, nicely constructed battery kzbin.info/www/bejne/hX7Hf4OCacSceas and currently an SFK which has the best app I've used kzbin.info/www/bejne/h6LWiZ6il5qhfrc Cheers, Ray
@jab376
@jab376 5 ай бұрын
Thanks you.
@quagmyer7230
@quagmyer7230 Жыл бұрын
BMS, no doubt, I have 4 12 volts 200ah plus on a 48 volt bank, and one is going up to 16.7 volts causing my inverter to go over the 60 volts limit and shutting off, currently waiting for Ampere time to respond.
@lakecavanaugh
@lakecavanaugh Жыл бұрын
Have you considered the inrush current from that inverter is higher than the BMS will tolerate and still protect the batteries from damage? The Chins battery tolerates it because it is a less capable BMS and that may seem like a good thing, but it will lead to premature battery failure of weaker cells. The AmpereTime works sometimes because of how fast you were connecting and disconnecting the inverter. A better inverter will precharge the internal capacitors to help decrease the inrush surge. I bet the inrush on that inverter is close to 300 amps.
@LoveYourRV
@LoveYourRV Жыл бұрын
A battery like that should have no issues starting up the inverter. It did the same thing in my RV system and my 3000W Motomaster inverter. I had used that to test it during the review back in November and it worked great, now it quits intermittently. So don't think its some in-rush thing. The inverter that I tested it with actually has an on/off switch so the caps are already charged. Cheers, Ray
@amperetimemarketing7931
@amperetimemarketing7931 Жыл бұрын
Thanks! To Ray , please check whether the inverter current exceeds 300A. Ampere Time12V200Ah self-heating battery board is 100 a, which is the biggest under current is 100 a. If this is the case, it will trigger the battery's overcurrent protection.
@amperetimemarketing7931
@amperetimemarketing7931 Жыл бұрын
@@LoveYourRV Ray, please check whether the inverter current exceeds 300A. Ampere Time12V200Ah self-heating battery board is 100 a, which is the biggest under current is 100 a. If this is the case, it will trigger the battery's overcurrent protection. Thank you!
@LoveYourRV
@LoveYourRV Жыл бұрын
I have tested with minimal loads, 50 to 600 watts in the heater tests, often just turning on the inverter with no load, causes the battery to power off. The Chins battery from the video has a 100 amp BMS also and powers the inverter with no problems, see my review here powering the same ALFFAA 1500 watt inverter www.loveyourrv.com/chins-200ah-battery-alffaa-1500w-testing-and-teardowns/
@LoveYourRV
@LoveYourRV Жыл бұрын
Tested the inrush current today with my clamp on amp meter. Average was about 60 amps. Max test was 86 amps.
@herb7877
@herb7877 Жыл бұрын
My 1st inclination is the BMS as well. either something is feeding back or something on the board has gone gunny-bags. Like reading too much or too little heat so it shuts off ??
@craigmckenzie8028
@craigmckenzie8028 Жыл бұрын
I agree with you it has to be the BMS. Maybe bad BMS or poor cable connection. Very weird. Did you try your amp clamp meter to see what kind of amps were going through inverter from the battery. When it failed and when it worked? Strange
@LoveYourRV
@LoveYourRV Жыл бұрын
Yes, I had a battery monitor with a shunt on it. When it quits all amperage stops. When it quit, everything in the RV died. When it's working it can put out well over 100 amps.
@craigmckenzie8028
@craigmckenzie8028 Жыл бұрын
@@LoveYourRV The Bms must be defective. That’s so strange. Good for you for finding it out now. That would be so frustrating. Great job troubleshooting. 👍
@LoveYourRV
@LoveYourRV Жыл бұрын
Tested the inrush current today with my clamp on amp meter. Average was about 60 amps. Max test was 86 amps. The battery has a 300 amp surge rating on the BMS
@craigmckenzie8028
@craigmckenzie8028 Жыл бұрын
@@LoveYourRV Good test. Just proves the BMS is defective. Cheers
@Scrambler1
@Scrambler1 Жыл бұрын
I had the same problem with a Power Queen self heating battery. Maybe they use the same BMS
@thegrizzlyfamily1374
@thegrizzlyfamily1374 5 ай бұрын
My LiTime did the same thing, but then, it would start working fine out of the blue. Makes me nervous.
@bboyda4399
@bboyda4399 Жыл бұрын
Ray, would you mind doing a test on the battery heaters? You might try disconnecting them, disconnecting the low temperature sensors, disconnecting all temperature sensors. I'm wondering if harmonics are involved, somehow?
@LoveYourRV
@LoveYourRV Жыл бұрын
I got a reply from LiTime last night. They looked closely at my video and seem to concur that the BMS is likely at fault. They offered another battery to evaluate. I told them either that or send me a new BMS board to try and replace. Guess I'll hear tonight as they are on China time. If I end up keeping the battery I'll dig into it further and troubleshoot more, but they may want it back to test themselves so I'll leave it for now. Cheers, Ray
@LoveYourRV
@LoveYourRV Жыл бұрын
They are sending a replacement so will do further tests.
@usmckozmo
@usmckozmo Жыл бұрын
You might be getting enough voltage drop to trip the BMS. I would try that test again with a thicker gauged cable. (Quick math says 1/0 AWG is recommended for a 2000w/12v inverter at full load)
@LoveYourRV
@LoveYourRV Жыл бұрын
Thanks, but I've confirmed it's not the cabling. Tried different gauges. In one case, use 2/0 one foot long. It's not a high current problem leading to a significant voltage drop. It also cuts out with very low wattage loads. Just turning on the inverter with no load attached was cutting the battery off. Or running a 50-watt fan. Cheers, Ray
@surfreadjumpsleep
@surfreadjumpsleep Жыл бұрын
If you used a big capacity to pre charge the capacitor in the inverter before attaching it. Maybe then it works? the BMS probably doesn't like the spike of power demand that the capacitor in the inverter creates.
@dwC4u
@dwC4u Жыл бұрын
Thanks for the video. No time for Ampere Time! :P
@barrydavies2977
@barrydavies2977 Жыл бұрын
It plainly says on the product description that it's a 100amp bms. That's enough for the 1kw inverter but not the 1.5kw. The charger looks no more than 20amp, but I don't know. That is not enough to make up the shortfall. So the battery is not at fault. The bms is protecting the battery internals.
@LoveYourRV
@LoveYourRV Жыл бұрын
Ampere Time techs watched the video and agreed that the BMS was faulty so they sent out a replacement. Here is my update video testing with the replacement kzbin.info/www/bejne/rJfQZ3-MlrGnhZI By the way, I tested the same 1500W inverter with other brand batteries that only have 100A continuous rated BMS, and the inverter started fine with them. Chins 100A BMS battery and AOtlithium 100A BMS battery start the 1500W inverter just fine. This is because most 100A BMS have a surge rating of 200A or more for a short period, sometimes even a few minutes. Not sure why the issue with this Ampere Time, but it seems to have something to do with the self-heating BMS as it reacted the same with 2 other self-heating BMS batteries I tested. I think they are all using the same brand BMS boards. Maybe they need to adjust the overcurrent shutdown protection to allow for the brief inrush current spike. They may have it set too strict. I don't expect the inverter to run a 1500W full output with a 100A BMS, but I expect it to start and run up to a 1200W load. Cheers, Ray
@timf6916
@timf6916 Жыл бұрын
WOW, I hate when things work like that. Trash can time. Garbage time.
@mja3514c
@mja3514c 4 ай бұрын
I have the exact same battery and it’s doing the exact same thing. Contacted them and they refused warranty. I haven’t gone through the rest of the comments, but I’ll be curious to read up on what’s going on with it.
@LoveYourRV
@LoveYourRV 4 ай бұрын
Here is my update video on the issue kzbin.info/www/bejne/rJfQZ3-MlrGnhZI Cheers, Ray
@GingerAvenger22
@GingerAvenger22 Жыл бұрын
I think your problem is that the heated 200 Ah Ampere Time battery only has a 100 Amp BMS. The Ampere Time Plus batteries have a 200 Amp BMS. If that inverter has max load on it, it’s probably pulling around 140 Amps or surging above 100 Amps when powering it on.
@LoveYourRV
@LoveYourRV Жыл бұрын
The loads I tested in the video were no load just the inverter turning on with nothing plugged in so just idle wattage, 50 watt fan and 600 watt heater. All fail to be powered. The battery would shut down. I've also tested on another inverter and small DC loads. The company looked closely at the video and seems to feel a bad BMS. Also, the Chins battery I tested only has a 100A BMS. Cheers, Ray
@LoveYourRV
@LoveYourRV Жыл бұрын
Here is a second video more clearly demoing what I'm seeing kzbin.info/www/bejne/fnrMdqxreNJ9f9E
@ryanmoore8492
@ryanmoore8492 Жыл бұрын
Bad connection from the battery to the cap? (Battery to the battery housing?)
@LoveYourRV
@LoveYourRV Жыл бұрын
Maybe, but it seems to work fine on my other inverter tested it several times and it always worked, whereas it quit with the blue inverter and also my 3000-watt inverter in my RV
@jimcollins1922
@jimcollins1922 Жыл бұрын
Did you ever get an answer from ampere time about what was causing the problem. I have a 100ah battery with similar issues - Thanks
@LoveYourRV
@LoveYourRV Жыл бұрын
They told me they suspected a faulty BMS board and replaced the battery and that solved the problem. Here was the update video I published. kzbin.info/www/bejne/rJfQZ3-MlrGnhZI Cheers, Ray
@jimcollins1922
@jimcollins1922 Жыл бұрын
@@LoveYourRV I am wondering with the inverter that is failing, if it might have some sort of startup draw or surge that is causing the problem? knowing little about this, would maybe a surge protector resolve that? I know the the renogy 2000w inverter charger that I have it cautions about a startup spark???
@LoveYourRV
@LoveYourRV Жыл бұрын
In my tests the inverter issue happened with only batteries that had self heating pads. Happened with 3 different brands. Kind of a weird problem. I suspect something with their BMS boards is different. Regular lithium batteries I've tested power the inverter just fine. The startup spark is only a thing to be concerned about when you first physically connect a battery to an inverter and usually only a big problem on larger inverters.
@jebw
@jebw Жыл бұрын
I think the troublesome inverter has high ripple current from the battery. The high spikes of current are what is most likely tripping the BMS because the BMS current monitor doesn't have an effective low pass filter. That's not to say the inverter isn't at fault as it should have filters on it's input as well to stop these noisy current spikes.
@LoveYourRV
@LoveYourRV Жыл бұрын
I've observed the battery intermittently shut down on other DC loads besides this inverter. But happens consistently with this inverter so used it for the demo. This inverter though has worked well on several other lithium batteries brands that I have tested it on. Aolithium, Lion Energy, Chins, and BougeRV
@LoveYourRV
@LoveYourRV Жыл бұрын
Here is a second video more clearly demoing what I'm seeing kzbin.info/www/bejne/fnrMdqxreNJ9f9E
@ovchannelag5238
@ovchannelag5238 Жыл бұрын
👍👍
@IFLYRace51
@IFLYRace51 Жыл бұрын
Just bought 2 of these, same issue when I enable my sungold 3000 watt inverter, battery goes dead! Had lead acid previous to these and had no issues with inverter! Not sure what to do, might have to return batteries.
@LoveYourRV
@LoveYourRV Жыл бұрын
They sent a replacement battery, which solved the shutdown problem when the charging stopped. See my updated video kzbin.info/www/bejne/rJfQZ3-MlrGnhZI But it still couldn't start my ALFFAA 1500W inverter. I paralleled the two of them, and it did start. I think they need to work on the BMS boards in these things as other lithium batteries start my inverters just fine. Cheers, Ray
@IFLYRace51
@IFLYRace51 Жыл бұрын
@@LoveYourRV I have two in parallel now, obviously the bms is an issue. I only have a month before a very long trip, I ordered these for my winter camping and this long trip boondocking often. Thanks for the reply.
@IFLYRace51
@IFLYRace51 Жыл бұрын
I gave up. Could not believe, my testing had the same result. I sent them back today, wrote a book on all the issues! They sent me return labels. I ordered new batteries with 200 amp BMS, these had 100. And really had issues with any transient, generated by power on/off, big load, etc.
@flyovercounty1427
@flyovercounty1427 Жыл бұрын
It’s definitely not the Turbo Encabulator. Looks more like a Main Bus B under volt.
@dheller777
@dheller777 Жыл бұрын
Think it's a faulty BMS. I have 2 of the 200 ah Ampere Time batteries and they are performing great.
@LoveYourRV
@LoveYourRV Жыл бұрын
Are they the 200Ah with the self heating pads? Just wondering if its the same BMS board. Ampere Time is going to send other battery for me to test out.
@ranig2848
@ranig2848 Жыл бұрын
Willing to bet its inrush - ie inverter requires a lot of amps when it starts up. Easy to test - you can probably add a capacitor on either side - if that's the case, it's the BMS blocking overcurrent. It's weird it happens so quickly, but some BMS are just more trigger happy with overcurrent. Maybe you can measure to current between the battery and the BMS to confirm or use a power resistor to reduce inrush.
@LoveYourRV
@LoveYourRV Жыл бұрын
A battery like that should have no issues starting up the inverter. It did the same thing in my RV system and my 3000W Motomaster inverter. I had used that to test it during the review back in November and it worked great, now it quits intermittently. So don't think its some in-rush thing. The inverter that I tested it with actually has an on/off switch so the caps are already charged. Cheers, Ray
@ranig2848
@ranig2848 Жыл бұрын
@@LoveYourRV There are 2 easy way to validate this assumption: 1. check max current when powering on (on both inverters), 2. if you can get your hands on a capacitor, you can place it in parallel. If inverter works fine with the capacitor, you know it's some form of inrush. As for why - it might be that the capacitors inside the "problematic" inverter are smaller than the other inverter or that the capacitors in the "problematic" inverters are getting older and therefore less effective at limiting inrush.
@LoveYourRV
@LoveYourRV Жыл бұрын
It has done the same on intermediately on small amperage DC loads that aren't even in inverters. Just seems to be very repeatable with this inverter so able to demo the issue.
@ranig2848
@ranig2848 Жыл бұрын
@@LoveYourRV Maybe that's why they changed the name from AmpreTime to LiTime - they don't want to be associated with a bad BMS 🤷‍♂
@amperetimemarketing7931
@amperetimemarketing7931 Жыл бұрын
@@ranig2848 That's not true. We are very grateful for your answer. We have a research and development team of more than 20 people. The BMS boards of batteries are all developed by ourselves. If you have any battery problems, please feel free to contact our customer service email, they will answer you professionally.
@kevinmills5293
@kevinmills5293 Жыл бұрын
Have you measured the cell voltages under load ? Perhaps you have a weak cell.
@LoveYourRV
@LoveYourRV Жыл бұрын
Yes, when the BMS does stay switched on the voltage output is normal under load. For some reason the BMS is falsely intermittently going into a protect mode is my guess.
@retroelectro1190
@retroelectro1190 3 ай бұрын
My 300ah Ampere Time (non-heating) battery recently began to shut down when the sun went down (solar system). I would hit it briefly with a generator, then the battery would come back to life. (Go from 0 volts up to its 13.4volts). I bought a 100ah Battleborn to replace... my question: can I throw my AmpereTime into parallel with the new Battleborn? I hate to think I need to throw the AmpereTime away!
@Google123ABC
@Google123ABC Ай бұрын
I’m having the same issue with mine. I have 2-230ah in parallel and every night they cut off. I only have a router that draws around 12 watts connected to my inverter.
@willymueller4587
@willymueller4587 Жыл бұрын
The power is being shut right down , the BMS doesn’t like something on that inverter
@LoveYourRV
@LoveYourRV Жыл бұрын
Its done the same on a different inverter and other 12V loads. Just seems to be very repeatable with this inverter so able to demo the problem.
@LoveYourRV
@LoveYourRV Жыл бұрын
Here is a second video more clearly demoing what I'm seeing kzbin.info/www/bejne/fnrMdqxreNJ9f9E
@davidpatrick1813
@davidpatrick1813 Жыл бұрын
I had many problems with my 200Ah Ampere time and they dragged me on and finally had to force a full refund and their paying shipping. ... It may seem crazy but a BattleBorn just works... like Victron ........................ I guess we get what we pay for. 5 years .. ain't no way. Li pronounced in the English language ... was their motto.. last sep/oct
@LoveYourRV
@LoveYourRV Жыл бұрын
Not always. ;) Another commenter was just referring to this --> BattleBorn 8D 270Ah 12V LiFePO4 battery Complete MELTDOWN kzbin.info/www/bejne/sJamXqKAl5eLhLM
@dwC4u
@dwC4u Жыл бұрын
Bad MOSFETs ?
@LoveYourRV
@LoveYourRV Жыл бұрын
It could be one intermittent, but weird how it works fine on one inverter and not the other.
@kr639
@kr639 Жыл бұрын
My A Time is all good!!!
@LoveYourRV
@LoveYourRV Жыл бұрын
Is it self heating model?
@kr639
@kr639 Жыл бұрын
@@LoveYourRV no that's the only difference. Mine is the regular 200 AH. I'd hate to have people think the battery is junk because it sure isn't. I have 2 on board right now and plan to add a third.
@LoveYourRV
@LoveYourRV Жыл бұрын
Thanks, good to know. So far I've only seen the inverter issue with the self heating type BMS and of course one of the batteries had the shutdown issue when charging is disconnected.
@larrycox6614
@larrycox6614 Жыл бұрын
I'll bet it's a solder issue with the BMS
@LoveYourRV
@LoveYourRV Жыл бұрын
Weird that it works consistently on one of my inverters though..
@larrycox6614
@larrycox6614 Жыл бұрын
@@LoveYourRV details shmetails...hahaha...yep forgot about that. Then the BMS has definitely gone TU, which you will not be able to figure out w/o a schematic... which would be a cool project, but....🙈🙈🙈
@JimNobles-gv4ky
@JimNobles-gv4ky Жыл бұрын
BMS board malfunctions on AT 50ah, won’t re-activate to fully charge, tried new charger to Activate, no luck, ready to throw battery in Garbage($199), used 3 times, did I run it too low, ??????????
@LoveYourRV
@LoveYourRV Жыл бұрын
See if they will replace it. They sent me a replacement, and it solved the problem. kzbin.info/www/bejne/rJfQZ3-MlrGnhZI
@JimNobles-gv4ky
@JimNobles-gv4ky Жыл бұрын
Thx. Gonna Bypass BMS….
@DansGamingVan
@DansGamingVan Жыл бұрын
So I shouldn’t buy this battery?
@LoveYourRV
@LoveYourRV Жыл бұрын
See my second update video kzbin.info/www/bejne/fnrMdqxreNJ9f9E&lc=UgznWPKMEUcM142U_-R4AaABAg Faulty BMS even shuts off when a charge is taken away with very small amp load. It should not do that. I proved that with the 8 amp air compressor load and no inverter hooked up. So BMS is faulty. Ampere Time support concurs. I've tried several other battery brands with 100A rated BMS the same test setup and they work fine. Ampere Time has sent me a new battery to try. I'll post an update when I have a chance to pick it up next week or so. Cheers, Ray
@DansGamingVan
@DansGamingVan Жыл бұрын
Any word from Ampere Time?
@LoveYourRV
@LoveYourRV Жыл бұрын
See my second update video kzbin.info/www/bejne/fnrMdqxreNJ9f9E&lc=UgznWPKMEUcM142U_-R4AaABAg Faulty BMS even shuts off when a charge is taken away with very small amp load. It should not do that. I proved that with the 8 amp air compressor load and no inverter hooked up. So BMS is faulty. Ampere Time support concurs. I've tried several other battery brands with 100A rated BMS the same test setup and they work fine. Ampere Time has sent me a new battery to try. I'll post an update when I have a chance to pick it up next week or so. Cheers, Ray
@DansGamingVan
@DansGamingVan Жыл бұрын
@@LoveYourRV thank you so much for letting me know!! I was hoping to order batteries this week, am deciding between SOK, Renogy, li-Time/AmpereTime, and Java. I also saw your last video saying the 200ah heated batteries low temp shut off didn’t work.. I always wonder if getting the entire battery cold, instead of putting the temp readers in cold water, would test differently, if the BMS has some temp reading function built in or something.. just a curiosity thought! I will be eagerly awaiting for your video, thank you very much!
@LoveYourRV
@LoveYourRV Жыл бұрын
I liked the SOK I reviewed when they first came out. I may be reviewing a similarly built one called a Lvgoo www.lvgoobattery.com/product-page/lifepo4-12v-battery-lv12v130 It interests me due to the way its built to be easily taken apart and parts replaced if needed. We'll see how the performance is.
@DansGamingVan
@DansGamingVan Жыл бұрын
@@LoveYourRV thank you so much for your replies and videos!!! I was originally going to go SOK but they’re about $5.15 per Ah, compared to the Chinese companies like Varter being $3.2 per ah or Amperetime at 3.6$ per ah… can’t decide if I should risk it for the savings or not 😅 600ah of Varter would be $1,919 while 600ah of SOK would be $3,087… definitely a worthy amount of savings, just scared the Varter low temp doesn’t actually work
@LoveYourRV
@LoveYourRV Жыл бұрын
Yeah, it's hard to know these days with so many different companies popping up now, but not much of a track record in years of use to go on.
Жыл бұрын
Poor filering and electromagnetic interference between the blue inverter and the bms.
@LoveYourRV
@LoveYourRV Жыл бұрын
The battery had a problem. Ampere time sent a new replacement to test. Here is that video : Update 3 - Testing the Replacement Battery In this video, I test out a replacement Ampere Time 200Ah self-heating battery to see if it solves a problem with the BMS cutting off when charging is disconnected. I’m happy to say the problem was solved. Unfortunately, though, it still won’t start my ALFFAA 1500W inverter unless I parallel two of them together. kzbin.info/www/bejne/rJfQZ3-MlrGnhZI Cheers, Ray
@dangeroustoman
@dangeroustoman Жыл бұрын
Just watched a video on Battleborn batteries starting on fire.
@projet2907
@projet2907 Жыл бұрын
Really ??
@dangeroustoman
@dangeroustoman Жыл бұрын
@@projet2907 yes I believe it was a video from PROJECTS IN PARADISE.
@LoveYourRV
@LoveYourRV Жыл бұрын
A bet it was a poor connection problem and not the lithium cells. Even lead acid batteries melt badly if a connection goes bad and starts to arc with high amperage running through it.
@kevinmills5293
@kevinmills5293 Жыл бұрын
Unfortunately that video has been pulled but fire appeared to be at the bottom of a cell and not around the terminals.
@LoveYourRV
@LoveYourRV Жыл бұрын
@@kevinmills5293 One of the drawbacks to the Battleborn design is they use tons of smaller cylindrical lithium cells versus the larger prismatic cells used in most. www.comoxmarine.ca/wp-content/uploads/2023/02/Whats-Inside-a-Battle-Born-Battery-BMS.webp This makes for many many more connection points to possibly fail or maybe never connected right in the manufacturing process. Hopefully an autopsy will be done and see what may have gone wrong.
@ogremgtow990
@ogremgtow990 Жыл бұрын
The second inverter does not like that battery.
@LoveYourRV
@LoveYourRV Жыл бұрын
Yes, check out my update video kzbin.info/www/bejne/rJfQZ3-MlrGnhZI I've informed the manufactures. Cheers, Ray
@ogremgtow990
@ogremgtow990 Жыл бұрын
@@LoveYourRV Sorry but I made a mistake. The rated discharge for this battery is 100 Amps or 1280 watts. Your second inverter might be checking for more current to get to 1500 watts which is just over 117 amps at 12.8 volts. So parallel batteries is the solution for the problem.
@LoveYourRV
@LoveYourRV Жыл бұрын
I tested some other lithium batteries that are rated 100 amps 1280 watts and they work fine with the inverter. Think it must be something to do with the programming of the BMS board.
@JimNobles-gv4ky
@JimNobles-gv4ky Жыл бұрын
A reset button is too much to ask
@williamsuttle3645
@williamsuttle3645 Жыл бұрын
Weird
@JimNobles-gv4ky
@JimNobles-gv4ky Жыл бұрын
My BMS is stuck on 10 volts….
@LoveYourRV
@LoveYourRV Жыл бұрын
Give these methods a try enjoybot.com/blogs/lifepo4-battery-news/what-is-the-best-way-to-wake-up-a-lithium-ion-battery
@Yukonjackman1
@Yukonjackman1 Жыл бұрын
Today's electronic device's...... i don't expect much .
@robertdillon9989
@robertdillon9989 Жыл бұрын
Cheap/faulty bms
@jtnoodle
@jtnoodle Жыл бұрын
Faulty bms
Osman Kalyoncu Sonu Üzücü Saddest Videos Dream Engine 262 #shorts
00:20
兔子姐姐最终逃走了吗?#小丑#兔子警官#家庭
00:58
小蚂蚁和小宇宙
Рет қаралды 12 МЛН
Когда отец одевает ребёнка @JaySharon
00:16
История одного вокалиста
Рет қаралды 16 МЛН
How Many 12V Batteries for 3000W Inverter
15:26
Cleversolarpower by Nick
Рет қаралды 247 М.
DCS battery! Youtuber Sued for Reviewing this Battery?! Let's Test It!
19:44
DIY Solar Power with Will Prowse
Рет қаралды 705 М.
TEAR DOWN: LiTime ( “AmpereTime” ) 12V 200AH LiFePO4  Budget Lithium?
16:34
Mispronounced Adventures
Рет қаралды 19 М.
The Top 9 Lithium Battery Mistakes for Van and RV Power Systems
24:50
Lithium Cells in Float Charge. Will it destroy your battery?
20:39
Off-Grid Garage
Рет қаралды 268 М.
5 Reasons To Get A (Bigger) Home Battery
22:07
Gary Does Solar
Рет қаралды 291 М.
2 Ways Lithium KILLS Your Alternator (and how to prevent it)
20:56
Clark's Adventure
Рет қаралды 265 М.
Osman Kalyoncu Sonu Üzücü Saddest Videos Dream Engine 262 #shorts
00:20