An Unorthadox Way To Fix My Blower Motor Issues | HVAC

  Рет қаралды 2,132

AB HVAC

AB HVAC

Күн бұрын

Пікірлер: 52
@gordonpotts753
@gordonpotts753 4 ай бұрын
That weight trick was a good idea
@AB_HVAC
@AB_HVAC 4 ай бұрын
Thanks. It was definitely a shot in the dark!
@DennisBuckley-yd6cl
@DennisBuckley-yd6cl 4 ай бұрын
That was a nightmare.Stuff is not being built like it used to be.Also most packages are not box right and are prone to deliver damage.Patience is a virtue.You are doing good my friend!
@AB_HVAC
@AB_HVAC 4 ай бұрын
Thanks so much! I'm just glad to learn something new everyday
@firesprk
@firesprk 4 ай бұрын
The calculated cfm is crazy accurate. Just make sure you set the proper tonnage in app. I always check with static pressure but it is typically spot on.
@AB_HVAC
@AB_HVAC 4 ай бұрын
Ah okay I have to set the tonnage, I'll remember that
@jkmarshall3553
@jkmarshall3553 4 ай бұрын
Nice fix!!
@warenmann1042
@warenmann1042 4 ай бұрын
I agree with John7017..The blades are not perpendicular (90 degrees) to the center plate/disc attached to the shaft. Easy fix, bend it back into shape. The scroll cage is light enough material to do so. Removing the weights is a band aid (just reduces vibration in this case), it does not fix the problem. Informative Video. Thank You...
@john7017
@john7017 4 ай бұрын
You Have a out of round blower wheel, shippers do not package they correctly and they are thrown in shipping. I've had this problem before, weights are not the problem, the wheel is out of round.
@AB_HVAC
@AB_HVAC 4 ай бұрын
So did I have one originally? I had the same kind of wobble on the factory blower wheel that came in the air handler originally. It was shaking and rubbing the blower housing originally, so I changed the wheel (last video) and then this video everyone had recommended replacing the blower at this point because it was suspected to be a bent shaft, replaced the blower and still shaking was there just not as hard. Removing the weights lessened the shaking and vibration even more
@justinbeam81
@justinbeam81 4 ай бұрын
Yeah buddy try another wheel, I would try to exchange the one you just got and tell them it was warped, good luck, btw love your vids keep em coming!!!
@sofalvr
@sofalvr 4 ай бұрын
I've been doing this for 34 years and I've never seen 2 brand new blower wheels both being out of balance. That was real mechanic shit you did on this one.
@randyhoff3676
@randyhoff3676 4 ай бұрын
I have been doing this for 39 years and I have seen it, and it was a Carrier unit
@RidingWithRamsey
@RidingWithRamsey 4 ай бұрын
Don’t fret about 20 degree superheats. Copeland recommends a minimum of 20 degrees at the compressor to prevent flood back. The following was copied from a Copeland bulletin….. In order to assure that liquid refrigerant does not return to the compressor during the running cycle, attention must be given to maintaining proper superheat at the compressor suction inlet. Emerson recommends a minimum of 20°F (11°C) superheat, measured on the suction line 6 inches (152mm) from the suction valve, to prevent liquid refrigerant floodback.
@airmechanical7163
@airmechanical7163 4 ай бұрын
Told you ! It's a good way to check the blower.
@richardvisco6370
@richardvisco6370 4 ай бұрын
Bad blower wheel damage in shipment seen this several times
@Djcarp83
@Djcarp83 4 ай бұрын
I’ve actually set the wheel on its side and pushed down and will bend back, but get a new one just in case
@Hvacstuff89
@Hvacstuff89 4 ай бұрын
Yes it's your wheel. With motor and wheel put together and motor on flat surface your wheel should not wobble. Any wobble is bad wheel. Sometimes in shipping they get bent. Also a quick way, but not as effective, is to just roll the wheel on the ground and see if it wobbles to the side or looks funny, this is a test you can do in the parts house parking lot
@utubepro7742
@utubepro7742 4 ай бұрын
I feel the pain I’ve gotten many outa balanced wheels but I have a motor warehouse locally and they have high end balanced wheel thank goodness
@ACSuperHeat
@ACSuperHeat 4 ай бұрын
Bad squirrel cage. Looks like lower rim bent or oblong. Hand speed, slight wobble, motor speed, pissed off customer. All good. Chalk it up to inexperience gaining experience. How it works. Good vid. Always got a new blower wheel. Eventually that wobble will stress the motor bearings.
@AB_HVAC
@AB_HVAC 4 ай бұрын
That was a new scroll cage wheel. Put it on in the previous video, then everyone recommended I replace the blower. So this video was about doing that and the problem was still there
@carlsmith5919
@carlsmith5919 4 ай бұрын
You can let the unit run like that until your new squirrel cage comes in. You will have to change that squirrel cage out. If not, it'll make the new motor bearing wear out.
@Paul-IE-Repairs
@Paul-IE-Repairs 4 ай бұрын
the wheel should come balanced from the factory, but in your case it was not true out of the box.
@HVACingMyWay
@HVACingMyWay 4 ай бұрын
The wobble would be the wheel not the motor.
@AB_HVAC
@AB_HVAC 4 ай бұрын
Last video I swapped the wheel, didn't change a thing, that's why people suggested changing the motor
@BULLDOGG
@BULLDOGG 4 ай бұрын
Looks like the wheel is diamond shaped.
@boatingcharlie1
@boatingcharlie1 4 ай бұрын
That squirrel cage is bent dude. That out of balance condition will ruin that motor.
@alfredhines505
@alfredhines505 4 ай бұрын
It has to be the motor bearing bro, that’s the only thing that makes the blower, wheel wobble.
@BLUAIRHVAC
@BLUAIRHVAC 4 ай бұрын
The weights are not the problem. The wheel is not in alignment. It is bent. You cannot spin a wheel fast enough with your hand to show a balance/weight issue. Just think about tires. You need a new wheel.
@AB_HVAC
@AB_HVAC 4 ай бұрын
Get another wheel? Like I just replaced it, I got another bad wheel from the factory?
@RobertTuck-vo8cw
@RobertTuck-vo8cw 4 ай бұрын
@@AB_HVAC Yes, sometimes the new wheels are defective. Changing it will be the only long term solution.
@Djcarp83
@Djcarp83 4 ай бұрын
Just change the damn wheel and problem solved 👍
@AB_HVAC
@AB_HVAC 4 ай бұрын
Problem with that is I already replaced the wheel, and it didn't solve the problem 😊
@Djcarp83
@Djcarp83 4 ай бұрын
@@AB_HVAC really that’s wacky I wonder what has happened to that, I wonder if someone had the wheel out for some reason and dropped it
@AB_HVAC
@AB_HVAC 4 ай бұрын
@Djcarp83 idk man you know stuff just gets thrown around supply houses 🤣
@Djcarp83
@Djcarp83 4 ай бұрын
@@AB_HVAC facts sir I’ve been there buddy, love the content keep it coming, electric wise when those modules go bad and your in a pinch take that mod off and these is a black diode which is what goes bad most of the time twist the two leads together and that can get you by most the time until you get another one but I always replace the whole thing not just the module
@BLUAIRHVAC
@BLUAIRHVAC 4 ай бұрын
Airflow is way too low for 5ton of cooling, target is 2000 hint hint! MQ showed you an issue and you did not recognize it. You are running 259cfm per ton, way to low when you want 350 to 400. 11:40 MQ tells you the airflow is below allowable range. The speed tap is to low or the new motor is the wrong size. Or the static on the duct system is way off.
@USA-GreedyMenOfNoIntegrity
@USA-GreedyMenOfNoIntegrity 4 ай бұрын
You do not need 2000! Try 1750 Max CFM.
@BLUAIRHVAC
@BLUAIRHVAC 4 ай бұрын
That wheel is going to come apart down the road, defective part.
@alfredhines505
@alfredhines505 4 ай бұрын
I think the motor bearing is shot.
@htownblue11
@htownblue11 4 ай бұрын
Blower wheel got,bent out of shape some how. Sorry you had to deal with that man.
@hvactechsecrets
@hvactechsecrets 4 ай бұрын
A 5 ton short 1.5 tons of airflow.... Say it aint so. That system probably has a single 30x20 return on a 18 inch duct.
@AaronPowellvox
@AaronPowellvox 4 ай бұрын
Sorry to say this but it’s just crappy equipment. Sometimes it cost the company more money to install crappy stuff because of all the warranty work you have to do.
@dipley3771
@dipley3771 4 ай бұрын
Bad blower wheel
@AB_HVAC
@AB_HVAC 4 ай бұрын
New wheel, installed 3 days before I took the video and that took a week to order. Would've taken another month to order another one
@dipley3771
@dipley3771 4 ай бұрын
@@AB_HVAC i'd order it now then lmao
@dipley3771
@dipley3771 4 ай бұрын
likely they sent you another bad wheel, problem isn't solved
@patrickbell4687
@patrickbell4687 4 ай бұрын
Replace it. Bad new part.
@deanjones3817
@deanjones3817 4 ай бұрын
It's wapped. Only thing to do is grab another one.
@techfive7202
@techfive7202 4 ай бұрын
Why not just roll it on the ground?
@AB_HVAC
@AB_HVAC 4 ай бұрын
Pretty sure it would've come out with the same results
@Hvacrpro123
@Hvacrpro123 4 ай бұрын
The squirrel cage is bent not the shaft
AC Capacitor hacker strikes again
13:37
Anti DIY HVAC
Рет қаралды 116 М.
Gas Package Unit Not Working Due To Common Problem | HVAC
17:16
So Cute 🥰 who is better?
00:15
dednahype
Рет қаралды 19 МЛН
The evil clown plays a prank on the angel
00:39
超人夫妇
Рет қаралды 53 МЛН
Your AC Compressor Might Be Going Bad, 2 Quick Ways To Find Out!
11:09
Service Call: Following another company!
35:09
HughesMan HVAC
Рет қаралды 40 М.
Should You Replace a Bad TXV with a Piston? & TXV Diagnosis!
21:53
AC Service Tech LLC
Рет қаралды 36 М.
A True Mystery Like NOTHING You've Ever Seen Before
9:02
Taryl Fixes All
Рет қаралды 74 М.
Package Unit Acting Up After Replacing Heat Exchanger | HVAC
20:51
FREE Solar Heating & Air Conditioning Is Finally Here...
21:08
The DIY HVAC Guy
Рет қаралды 1,4 МЛН