@gapo62angler93
@gapo62angler93 2 жыл бұрын
I watch a lot of this connector videos and I don’t understand why 99% of people land the wires on the breaker first , it’s always a good practice to always land your wires on the load side first for safety purposes just in case you have a faulty breaker or in case someone accidentally turns the breaker on while you’re landing wires on the wall connector after you have landed wires on the breaker. Just my honest opinion. 🙏🏽✌🏽
@atb2003
@atb2003 Жыл бұрын
The Install seems clean but NEC prohibits single conductors without conduit in the wall. (4/3 romex could have been used without using the white wire). Also NEC requires 3 ft clearance on the panel and the Tesla controller appears to be in the way of the bottom right corner; otherwise good video.
@jeremytews3006
@jeremytews3006 2 жыл бұрын
THHN wire needs to be in conduit for anyone watching this video. Don’t follow this video
@lymanhall5449
@lymanhall5449 2 жыл бұрын
Exactly… A big no-no..
@ericjorgensen4826
@ericjorgensen4826 2 жыл бұрын
You could also use some #6 AWG NM (non metallic (Romex)) cable in this application, but not individual wires taped up. Also need a Romex connector where the NM cable goes into the wall connector.
@00056433
@00056433 2 жыл бұрын
Agree with you guys, it has to be in a conduit
@GROGU123
@GROGU123 Жыл бұрын
@@ericjorgensen4826 No you can't use Romex 6/2, unless you limit the breaker to 50 amps. Romex 6awg is only rated to 60c ampacity, which is 55amps. For this application, to get the full charge rate, you need a 60 amp breaker. Proper design capacity is 80% of the breaker, as being your actual load which is 48 amps.
@brianbeasley7270
@brianbeasley7270 2 жыл бұрын
I'm concerned about these installations and giving people bad information. THHN cable inside walls requires conduit. The electrical tape wrap you did is not going to meet code. It would have been simple to install a short piece of plastic conduit in this installation by just making the hole size in the wall a bit larger and inserting it through the wall and fastening it on both ends (service box and wall charger). I believe you could have used 6-2 Romex without conduit and been just fine but it is supposed to be strain relieved with a fastener. Some of the strands of wire on the red conductor were both nicked and removed on the second cut which is a no-no also as this reduces ampacity.
@christophertilley4297
@christophertilley4297 2 жыл бұрын
I researched this extensively. 6/2 Romex doesn’t have the ampacity. It’s rated at 55 amps for short duration loads and only 44 amps continuous. The charger can do 48amps. I ended up using 6/2 MC cable as it can be run like romex, but for this short distance, who cares about conduit? Also noticed the wrong clamps used, but yet again, for this distance who cares. He practically installed it less than a foot from the panel.
@mech-E
@mech-E 7 ай бұрын
You can make an account for free to read the NEC online. Most people don’t know what the code is and therefore don’t follow it.
@brianbeasley7270
@brianbeasley7270 7 ай бұрын
​@@christophertilley4297 The EVSE can be provisioned to accept a 50 Amp breaker and 40 Amp continuous, so Romex is OK as long as that is how the EVSE and circuit is provisioned. For 48 Amps, THHN in conduit should be used. Code certainly cares about conduit for THHN cables inside walls.
@dsipropertiesllc6049
@dsipropertiesllc6049 2 жыл бұрын
Plainly said: Very dangerous to install 240V - 60 Amps wires hidden behind sheetrock without conduit! Do Not Do This!
@KevinHartman84
@KevinHartman84 Жыл бұрын
BINGO! #wherestheconduit
@somemovingpictures
@somemovingpictures 2 жыл бұрын
A little nit pick here. It would be safer to fully wire the charger prior to wiring the panel. The chances of the breaker being switched are minimal, but with the panel open and right above where you are working, they do exist.
@jeffkass858
@jeffkass858 2 жыл бұрын
Hi Dave. Your videos are my favorite Tesla related ones to watch. You never disappoint me. Safe travels!
@johnpoldo8817
@johnpoldo8817 2 жыл бұрын
It’s nice to see old-timers my age successfully tackle a DIY install. I loved the Dynamo label maker, ass-end first, and smoke test references. I can relate using the same terminology.
@KevinHartman84
@KevinHartman84 Жыл бұрын
Half assed tackling. Gotta know how to do it right IMO......or real electricians have to come back and fix jerry rigged shit later.
@johnpoldo8817
@johnpoldo8817 Жыл бұрын
@@KevinHartman84 Gee, I thought Dave did a good job, except for lack of 1 ft conduit. Dave appears to have electrical engineering experience.
@KevinHartman84
@KevinHartman84 Жыл бұрын
@@johnpoldo8817 engineering and electricians are different. One sits at a desk and draws plans, one does install and sees the errors with the plans. Dave doesn't even appear to know what the NEC is. My 2 cents
@1983randerson
@1983randerson 2 жыл бұрын
Next time hire a licensed electrician.
@dmdrewitt
@dmdrewitt 2 жыл бұрын
Very interesting to see these Wall Connector installs. Thank you Dave. You go a great job one handed whilst holding the iPhone!!
@robm6962
@robm6962 Жыл бұрын
Would have been nice if you wired it to code when you went into that electrical box that’s is not to code😢
@mroryyoung
@mroryyoung Жыл бұрын
Noticed the Use of THHN inside a wall without conduit. NEC code violation. Metallic flex or flex pvc would have worked well.
@KevinHartman84
@KevinHartman84 Жыл бұрын
Yes, does dave really know what he's doing? lol
@jimsummers487
@jimsummers487 8 ай бұрын
Do you always film your fire code violations?
@coldnorthAK
@coldnorthAK 2 жыл бұрын
Love the ol paper towel to hold the apex bit in.
@jelderBEATMONSTA
@jelderBEATMONSTA 2 жыл бұрын
I love the micro management in this video
@wolfejar
@wolfejar 2 жыл бұрын
Great video. I’m a native to Colorado, my grandfather worked in golden at the Coors a long time ago. Great city.
@JohnWoodell
@JohnWoodell Жыл бұрын
Why are you not running romex?
@mowcowbell
@mowcowbell Жыл бұрын
I'm amazed at how thin & flexible that cable is on the Tesla Wall Connector. The cable on my Autel Maxicharger is much thicker and far less flexible.
@evdave528
@evdave528 Жыл бұрын
Wire with lots of annular area with small stands is smaller with same current capability.
@themeg522
@themeg522 Жыл бұрын
Good Video, I thought the largest breakers IE 60AMP should be placed nearest to the main lines. I see the 60AMP furthest away from the main lines.
@evdave528
@evdave528 Жыл бұрын
For best results locate the 60 amp breaker close to the main breaker but if due to existing wiring it may not be possible
@billsharp2351
@billsharp2351 4 ай бұрын
Wow! So many code violations, it's scary. And no connections torqued to spec anywhere.
@greglambert5154
@greglambert5154 2 жыл бұрын
Another satisfying wall connector install. Is the beginning of you and Greg starting your own electrify America network??
@sarcasmmuch8905
@sarcasmmuch8905 2 жыл бұрын
44 years says if you don’t know what you are doing you shouldn’t do it
@KevinHartman84
@KevinHartman84 Жыл бұрын
Well put. Obviously dave only knows a lil bit, not a lot.
@eniobaptista8008
@eniobaptista8008 Жыл бұрын
What will happen if you don't connect the wall connector to Wi-Fi ?
@KevinHartman84
@KevinHartman84 Жыл бұрын
where's your conduit?!?
@Dezmond_Roman
@Dezmond_Roman Жыл бұрын
Where is the conduit?
@anthonychappell4746
@anthonychappell4746 4 ай бұрын
What was the purpose of the soap?
@redding4540
@redding4540 Жыл бұрын
I don't know if it's secure enough to hold on drywall with all the pulling, stretching and putting a weight on that thing. Whole thing broke off after 15 months later. I relocated to stud.
@mitchellbarnow1709
@mitchellbarnow1709 2 жыл бұрын
Another excellent installation! I wish that I got had done it this way instead of having a NEMA14-50 outlet installed.
@laloajuria4678
@laloajuria4678 2 жыл бұрын
i mean if you need 48A, its hard wired. having the nema while slower, is way more versatile for the future.
@mowcowbell
@mowcowbell 2 жыл бұрын
I'm glad I went with a NEMA 14-50 outlet. I can charge any EV with this setup.
@vilo3454
@vilo3454 9 ай бұрын
DO NOT FOLLOW THIS VIDEO. THIS IS ONE OF THOSE “EHHH ITS WORKIN, SO ITS FINE” JOBS. First its mounted too damn low, even the manual that comes with the charger says mount at shoulder height for convenience, They used no conduit and at least could have used a jacketed wire. PLus I don’t hire anyone who uses the term “drill gun” ….It’s a DRILL , where are you getting the “gun” part from…it doesn’t shoot anything????!!!
@brianpreston8483
@brianpreston8483 2 жыл бұрын
But I love watching the Tesla owners sleep in their cars at dunkin donuts
@trevoralaine
@trevoralaine Жыл бұрын
Try lubing your screws with bees wax from a toilet bowl ring.
@AndrewDyle
@AndrewDyle 2 жыл бұрын
left handed, or sinistral, is an advantage in life.
@Chito350
@Chito350 2 жыл бұрын
Hi Dave Great Video! …….Question? How were you able to tighten the 3/4 wire clamp to the breaker panel? I know those clamps have a lock ring? Thanks in advance
@evdave528
@evdave528 2 жыл бұрын
Snap in type
@johnsisneros5135
@johnsisneros5135 Жыл бұрын
Why did you go red, black, green. The Tesla video shows black , red, then green,???? Will it damage or blow if the black is first then the red??
@jacklurie2496
@jacklurie2496 8 ай бұрын
Electricity is color blind.
@pavels5600
@pavels5600 2 жыл бұрын
I'm also planning on using a 60A breaker & 4AWG for the full 48A sometime in 2022. Many KZbin videos show the Tesla Gen3 charger being installed with 50A & 6AWG for 37A. I don't know why they limit themselves so much.
@evdave528
@evdave528 2 жыл бұрын
V3 wall connector, 60 amp breaker, #6 or 4 to run 48 amps
@Zazupii
@Zazupii Жыл бұрын
I’m getting 48A on a 60A breaker with a #8
@GROGU123
@GROGU123 Жыл бұрын
@@evdave528 Romex is only rated for 60c temperature, that said 6awg is only rated for 55amps@60c. If using Romex, it must be 4awg for your 2 poles and 8awg for the ground. You can use 6awg THHN wire in a smurf tube, but you must also make sure your breaker is rated for at least 75c temp. If all your components are rated for 75c or higher, than you're good for 65amps and should be fine.
@GROGU123
@GROGU123 Жыл бұрын
@@Zazupii Even THHN cable @90c is only rated for 55amps. 8awg Romex is only rated for 40 amps. You're going to burn your house down running Romex. You can get away with THHN because the charger only uses 48amps max, which is under the 55amp rating. But that's not following the design code of 80% load. You're flirting with danger using THHN 8awg and fire is very possible using Romex 8awg.
@stevephla
@stevephla 4 ай бұрын
@@Zazupii That #8 must get pretty warm at 48A sustained.
@YoYoRaMa
@YoYoRaMa 2 жыл бұрын
Can you provide the link to buy the same power/wire (black/red/green) thanks for the details.
@aclevelandjr
@aclevelandjr 2 жыл бұрын
I just got a gen 3 wall connector installed. Should it make a click noise when it turns on and off? I just wanna make sure it was installed correctly. I got it installed a couple of weeks ago and took delivery of the car today so I couldn’t test it then.
@lymanhall5449
@lymanhall5449 2 жыл бұрын
Ok.. I’ve seen enough 🤦😳
@user-ok1vo6hf3i
@user-ok1vo6hf3i 2 жыл бұрын
we installed the Tesla wall connector today, but when connecting to the wall connector Wi-Fi, it keeps showing that there is no Internet connection, so I can't enter the wall connector setting page, but I can't enter the Ip page! Do you know why? Is it because the wall connector Wi-Fi is broken? Or do you need a car next to you? Or for other reasons?
@Joe-ff1oh
@Joe-ff1oh Жыл бұрын
Is the wire aluminum
@christophertilley4297
@christophertilley4297 2 жыл бұрын
Interesting. I installed mine with 6 gauge as it has an ampacity rating of 65 amps (or 52 amps continuous load). The cable run is only 20 feet. Any reason you went with 4 gauge?
@gonebyrv9748
@gonebyrv9748 2 жыл бұрын
Look at 7:45. I believe that is 6 gauge wire.
@evdave528
@evdave528 2 жыл бұрын
I think #6 was used at 20 inches
@russrockino-rr0864
@russrockino-rr0864 Жыл бұрын
I see several Code violations. Come on Dave! If you don't know what you are doing, hire an Electrician. At least hire an Electrician to consult with you. Thanks, Russ, J Electrician from Oregon.
@RSwrightMD
@RSwrightMD 2 жыл бұрын
Another flawless installation. Remind me to invite you up when I install mine! It is also nice to see Greg keeps DX Engineering on his favorites. I do the same!
@brookemiller7230
@brookemiller7230 2 жыл бұрын
Did you drive all the way to Golden, CO just to install the Tesla wall connector?
@evdave528
@evdave528 2 жыл бұрын
No
@dannyfought7525
@dannyfought7525 2 жыл бұрын
Dave I have a new Tesla Y long range (340) mile. How many miles can I go on a 10 degree day leaving Salida Colorado going to Crested Butte?
@evdave528
@evdave528 2 жыл бұрын
Danny, cold air it thicker and range will be less. Slow speed gives you longer range. At 75 mph I can get 235 miles on my performance Y, you should get more. 297 miles at 55. I guess you might get a 15-20% range loss in the winter.
@ronaldnaeyaert3653
@ronaldnaeyaert3653 Жыл бұрын
What is the conduit?
@chrisday8072
@chrisday8072 Жыл бұрын
really bad they only give us 2 screws in the UK
@evdave528
@evdave528 Жыл бұрын
Those stainless screws hold fine but be sure to pre drill the correct sized pilot hole
@nithinsekhar7782
@nithinsekhar7782 Жыл бұрын
Can i use 5core 10sqmm wire for From DB to connector?
@evdave528
@evdave528 Жыл бұрын
Consult a local electrician
@beelust4312
@beelust4312 Жыл бұрын
Should have watched this video before I paid to have my wall connector installed. Today Feb 14th, 2023
@latehappylife
@latehappylife 2 жыл бұрын
Dave I just installed my wall connector. I have a problem with the commission. I fallow the instructions but it never asked me to put my wi fi password in. What am I doing wrong!
@evdave528
@evdave528 2 жыл бұрын
Scan the QR code and set the op address on your browser in the phone ( website from the wall connector) to access settings
@evdave528
@evdave528 2 жыл бұрын
After a hard power reset the WC can be accessed for I think 5 minutes. Follow the little piece of paper that comes with it
@gregwatson8246
@gregwatson8246 3 ай бұрын
‘WiFi’ signal is being used to allow your phone to connect and communicate with wall connector, for settings or “commissioning. It’s not ordinarily being connected to your home network. No need for your home WiFi password. WiFi “signal is also used if you have multiple wall connectors power sharing with each other
@CarStory
@CarStory 2 жыл бұрын
Did that house have a 200A service?
@evdave528
@evdave528 2 жыл бұрын
Yes
@gimmieboy
@gimmieboy 2 жыл бұрын
How do we hire you two? I'm in the Charlotte area.
@ihearttesla
@ihearttesla 2 жыл бұрын
I was wondering the same about EV Dave...
@gimmieboy
@gimmieboy 2 жыл бұрын
@@ihearttesla are you in this area too
@ihearttesla
@ihearttesla 2 жыл бұрын
@@gimmieboy No, LI/NY area! But seems like EV Dave takes a LOT of road trips!!
@evdave528
@evdave528 2 жыл бұрын
Tesla has a list of approved installers, about 1000-1200 please cost off wall connector they charge
@gimmieboy
@gimmieboy 2 жыл бұрын
@@evdave528 well I know that. I guess it was a question since you are installing lol. But I can get it done.
@montmuscle1986
@montmuscle1986 Жыл бұрын
How much do someone charge for one of these jobs?
@evdave528
@evdave528 Жыл бұрын
500-900 bucks
@pinkiepie1656
@pinkiepie1656 11 ай бұрын
Too much. That's why I installed mine myself.
@jimsummers487
@jimsummers487 8 ай бұрын
This guy will burn your house down…… we call this a willful fire code violation
@NaimBarakat
@NaimBarakat Жыл бұрын
Is this by NEC Code?
@KevinHartman84
@KevinHartman84 Жыл бұрын
NOPE THHN requires a raceway/conduit
@sogard2799
@sogard2799 Жыл бұрын
Absolutely not.
@md929
@md929 2 жыл бұрын
Clean install for couple of old farts. ;)
@Dezmond_Roman
@Dezmond_Roman Жыл бұрын
Fire hazard
@Pervernoned
@Pervernoned Жыл бұрын
This guy talks too much!
Tesla Wall Connector Installation with MC cable
19:46
HandyDadTV
Рет қаралды 40 М.
Installing Tesla Wall Connector With a Master Electrician
18:48
Dirty Tesla
Рет қаралды 127 М.
WHO CAN RUN FASTER?
00:23
Zhong
Рет қаралды 43 МЛН
Running With Bigger And Bigger Feastables
00:17
MrBeast
Рет қаралды 136 МЛН
Нашли чужие сети в озере..💁🏼‍♀️🕸️🎣
00:34
Connoisseur BLIND420
Рет қаралды 3,6 МЛН
How To Install a 240 Volt Outlet | Electric Car Charging
48:44
Everyday Home Repairs
Рет қаралды 2,6 МЛН
How to Install the Tesla Wall Charger Connector | Full Detailed Guide
15:45
Dangerous Disconnect: Tesla Home Charging Problem Analyzed And Corrected
26:55
Can You Install a EV Wall Charger Without Trouble?
36:48
EV Dave
Рет қаралды 71 М.
How To Install An EV Car Charger | Easier Than You Think!
10:17
Everyday Home Repairs
Рет қаралды 57 М.
Stop Killing Your Tesla Battery! How to Charge the Right Way
12:50
Tesla Wall Connector Gen 2 vs Gen 3 - Should you upgrade?
25:58
Artisan Electrics
Рет қаралды 55 М.
HOW TO INSTALL TESLA WALL CHARGER GEN 3 Wall Connector
8:44
Kevin Pon
Рет қаралды 9 М.
WHO CAN RUN FASTER?
00:23
Zhong
Рет қаралды 43 МЛН