Thanks for making this video my friend! I will be working on one with micro switches and mechanical levers.
@hosielochoa5213Ай бұрын
muchas gracias!🙏🏽🙏🏽
@AT-im3je Жыл бұрын
Great video. Thank you so much
@alvarocabrera9020 Жыл бұрын
Gracias por su informacion senor Lopez.
@tonyhernandez38732 жыл бұрын
Thank you for the illustration
@sergiomateo7671 Жыл бұрын
Buen trabajo. Good job
@tonyhernandez3873 Жыл бұрын
Cuándo se usan los shun trip breaker es únicamente para todo lo que está directamente abajo de el ecractor ,los shun trip se conectan en parallelo entrsi dentro de el panal,luego todos ya conectados se toman dos alambres de control que ban en el ST NI en el control de el extractores y la supply Mu Aire fresco.etc gracias
@samrockoibv3669Ай бұрын
Thanks sr
@lmao63742 ай бұрын
Can you take a phone call?
@Gman737e2 жыл бұрын
Nice video
@ivanbehnam78222 ай бұрын
Tx 👍
@abdulmohammed9276Ай бұрын
Do the exhaust fan have to be on a shunt trip breaker also
@anaperalta4079 Жыл бұрын
Hello Jaris , thanks for sharing this great knowledge I would like to to ask you a lot of question . let me know how else can I contact you Thank you.
@jarisisimo4you Жыл бұрын
Yes send a text to 760 827-9278
@mhmh2336 Жыл бұрын
Jaris are you familiar with ansul red Suppresion system?
@user-nd8bs7wq3e4 ай бұрын
I'm from China. How can I contact you?
@barberhvac34389 ай бұрын
FYI..that’s not an ansul system. It’s a TANK system by Captiveaire
@kidakvls23056 ай бұрын
Hi what is going into A1 and A2 of the contactors for the fans?
@theylovedemari2258 Жыл бұрын
How much do a job like that cost I have one coming and can’t price it it is a brand new kitchen
@jarisisimo4you Жыл бұрын
I work for a company all kitchen hood comes with panel , it has room for hood Lts , MUA, E Fan + 120 to power the panel that can also share with lights; what you do is run a extra 12/2 mc from electrical panel to hood panel, so all electrical equipment directly under hood should be wired directly from electrical panel to an wall outlet under hood, those each one should have an shunt trip breaker, so the extra 12/2 mc will be connected at the panel on parallel (one side of each shunt trip should be spliced to the black wire, and the other side of the breaker which is one of the 2 wires factory attached on breaker, should be spliced to the white wire; so in the hood panel that 12/2 mc spliced to shunt trip breakers, should be as diagram in hood panel.
@jesussilvadoray8187 Жыл бұрын
Hi. Does anyone know the price to install hood control panel. Im in the process of install in a restaurant
@nicthespic3023 Жыл бұрын
@@jesussilvadoray8187 anywhere from 5-10k
@firstpower64847 ай бұрын
Thanks
@abdulmohammed9276Ай бұрын
I would like to call you also because I’m actually have to do one tomorrow