A detailed look at diverter valves in a boiler - Part 1

  Рет қаралды 157,306

Baxi - sustainable heating and hot water solutions

Baxi - sustainable heating and hot water solutions

Күн бұрын

Пікірлер: 59
@TobyWanKenobi-1
@TobyWanKenobi-1 3 ай бұрын
Thank you for making this video, I bought a replacement valve and when I removed the old one in six pieces I thought I would have to go all the way back to the plumbers merchant to get a different valve. My wife said look at KZbin so this video saved my day.
@lettoservicedaccommodation7764
@lettoservicedaccommodation7764 4 жыл бұрын
One of the best videos I’ve seen to help with training, the cut always are a fantastic way to learn, more of them please
@douglaughton7626
@douglaughton7626 6 ай бұрын
I watched this to familiarise myself with how the bi-pass operates. Great video. Thanks 👍
@Hambini
@Hambini 2 жыл бұрын
That was an excellent tutorial. The strength of your training videos has made me fit baxi 800s now!
@pointyplumber
@pointyplumber 4 жыл бұрын
As usual Baxi seeing a possible Problem and evolving to deal with it. Brass parts comon sense unlike some bignanes still using plastic. . Great video what a way to get back in to it.
@tomadams94
@tomadams94 4 жыл бұрын
Yes, although ironically the big name you are talking about have the best diverter lol
@stevekelly5166
@stevekelly5166 Жыл бұрын
I'm a different type of engineer but own one of these. Brilliant description of how it works. You kept is simple, to the point, and explained the operation. Not sure about o-rings being rotated many times as they seat though.
@smellslikethinice1107
@smellslikethinice1107 4 жыл бұрын
Great vid, you guys (Baxi) go the extra mile, Thanks
@eazyrat
@eazyrat 3 жыл бұрын
awesome way to show how it works...in 5 minutes too. thanks
@scottiedog4236
@scottiedog4236 4 жыл бұрын
Baxi are mega good ! Installed loads and I’ve got one
@pointyplumber
@pointyplumber 4 жыл бұрын
Back with a blast
@fly-high-me
@fly-high-me 2 жыл бұрын
Thanks! Exactly what i'm looking for
@IJHougfhton
@IJHougfhton 4 жыл бұрын
Hav you upgraded the seals on the top as I have changed loads that leak into the electric motor shorting out the boiler blowing the fuse
@gearstil
@gearstil 3 жыл бұрын
Best explanation so far!
@antonybuckley2645
@antonybuckley2645 4 жыл бұрын
Great video Richard. Any chance of videoon removing insulation panel on the solo heat only
@electroumit
@electroumit Жыл бұрын
Thanks. Good work.
@al-azimahmed1188
@al-azimahmed1188 Жыл бұрын
This is an excellent video, I think a customers boiler has a diverter valve issue for hot water not working, rather then a block heat exchanger
@abualam4418
@abualam4418 3 жыл бұрын
Great video
@hamzaparvais3948
@hamzaparvais3948 3 жыл бұрын
Fantastic video like the way u teach thanks
@Snaggleplops
@Snaggleplops 2 жыл бұрын
Brass components, lovely 😍
@baffoxxx2117
@baffoxxx2117 3 жыл бұрын
Hello, my question is the following: When the boiler is off, where is the three-way valve positioned towards the heating systems or the sanitary water? Thanks
@SayWhaaaaaaaaaaaaaaaaaaaaaaat
@SayWhaaaaaaaaaaaaaaaaaaaaaaat Жыл бұрын
Where setting is set. You can set it. Also manufacturers can change default. My baxi was on central heating default value where it always returns. You can have 3 values. Dhw, HC or Last requested - aka do not go back,stay where you are
@faroyoussef1757
@faroyoussef1757 Жыл бұрын
What are spanner’s are you using?
@deanbenton6965
@deanbenton6965 2 жыл бұрын
How much would that cost to change
@mikepeck9260
@mikepeck9260 2 жыл бұрын
it would appear my diverter valve is whining when on heat and you can hear it slowly close as it switched to DHW, i can replace the whole assembly it seems but could not find the cartridge itself. Do you know where i could just get the cartridge for a Laars Mascot HT 330? looks identical to the valves in this video
@doma5262
@doma5262 2 жыл бұрын
My valve cartridge is not sized but my replacement diverter valve has failed within a month. Is something else faulty I'm missing or have I been stung by poor quality spares?
@daddybassi
@daddybassi 4 жыл бұрын
It's a great vid. The cartridge isn't suited for the boiler that have a bypass. I'm afraid you would need to fit the complete diverter valve.
@Bertie211
@Bertie211 Жыл бұрын
Learn that the hard way…
@NIIS150
@NIIS150 2 жыл бұрын
I have a horrendous whistle from my boiler and it seems if I flex the diverter valve head the whistle stops. It got so bad I wedged a bit of wood in there but then the whistling started again…always seemed to be within the first few minutes of the heating coming on. Replaced the head but hasn’t solved the issue. Could this be cartridge related? Or something completely different.
@luketaylor1678
@luketaylor1678 Жыл бұрын
Hi, did you ever solve your issue? I believe that I'm experiencing the same.
@darrenwilliamson3418
@darrenwilliamson3418 10 ай бұрын
how do you get valve out if it snaps old plastic one
@MikeHenderson66
@MikeHenderson66 2 жыл бұрын
Is there a spec sheet for these valves which gives the value of pressure that causes the auto bypass function to open?
@offplanetevent
@offplanetevent 4 жыл бұрын
How does this connect to my toilet valve that has a bidet washlette seat?
@davidwands1899
@davidwands1899 4 жыл бұрын
Via the condensed transporter fluxed capacitor, silly.
@offplanetevent
@offplanetevent 4 жыл бұрын
@@davidwands1899 But how do I regulate the gigawatt transformer to increase in power when the blow dryer is activated during the mega flush setting. I heard it can blow out the flux inverter relay.
@davidwands1899
@davidwands1899 4 жыл бұрын
@@offplanetevent Ahhh, you need to run a 780 volt 32mm modular cable between the inlet orifice diode and the niobium oxide multi faceted capacitors and adjust where necessary with an 8lb pin hammer. If this doesn't work, I would advise quickly procuring a paddle, you'll need it where you're going.
@offplanetevent
@offplanetevent 4 жыл бұрын
@@davidwands1899 I agree with you, but Im thinking a 10lb self- regulating pin hammer would be better than a standard 8lb pin hammer. I will keep you posted, hopefully with success. Paddles give me blisters.
@extranow
@extranow 3 жыл бұрын
hi, what model and brand of the 3-way valve in the video? thank you
@surinderpaulkansal6977
@surinderpaulkansal6977 Жыл бұрын
the heating is off. but when hot water tap is opened why heating pipe gets very hot ?
@spacecadet3339
@spacecadet3339 3 жыл бұрын
Thank you... very helpful
@ali98973
@ali98973 3 жыл бұрын
hi my baxi due tec 40he keep loosing pressure every day how to repair this
@maher8653
@maher8653 3 жыл бұрын
thankyou very good explanation
@FATHEROFTHREEKIDS
@FATHEROFTHREEKIDS 3 жыл бұрын
This diverter has been replaced 4 maybe 5 times in 7 years on my baxi duotech 24 he, any idea why this fails so often, also recently noticed hot water temp gauge goes over 60 when its set to 50, it also exceeds 65 which is supposed to be the max, do you think there is a fault with something or is this just normal for baxis
@Stillbusy105
@Stillbusy105 3 жыл бұрын
Normal for Baxi, buy cheap buy 4 maybe 5 times...
@robertrampley5248
@robertrampley5248 Жыл бұрын
How much do diverter valve cost ?
@theresaroper8923
@theresaroper8923 4 жыл бұрын
Great video but you don’t go on to say if pressure keeps dropping due to a leak and water dripping from underneath what to do and what could be causing this
@chrisjohnston5411
@chrisjohnston5411 3 жыл бұрын
Call a gas safe fella out to fix it
@MSKChess
@MSKChess 4 жыл бұрын
Baxi v plastic components - Baxi wins!
@londonertiger7725
@londonertiger7725 2 жыл бұрын
The top on the diverter valve leaked back in 2020 and was replaced in early 2021, now its leaking again on my Main eco compact.
@colingraham9281
@colingraham9281 Жыл бұрын
Its a common fault on these boilers, including the Potterton sister boilers. The rubber o rings on the cartridge break down and cause the assembly to leak. I had 5 changed on my original Potteton Gold 33 between 2015 and 2018. They even exchanged the boiler for free after changing the cartridge 3 times, the valve once, and the whole manifold once. The new boiler, installed in 2018 had a new diverter cartridge fitted in 2019 under warranty. It's failing again now even with a Magnaclean filter inline, regular servicing and a system flush before both installs. I cannot fault Baxi customer service, but would I buy one of their boilers in the future? No chance.
@waynehardiman9421
@waynehardiman9421 3 жыл бұрын
How come the rubber o ring has deformed at the top ?
@gedheaton1415
@gedheaton1415 2 жыл бұрын
Its just because the valve is cut away
@mouradjday1855
@mouradjday1855 2 жыл бұрын
Good morning can You send to me pdf with thé signification of défauts code and how to réparé thanks
@mgabrielle2343
@mgabrielle2343 3 жыл бұрын
lve seems similar or perhaphs same as used in Biasi Riva M90E boiler,
@eddiereed5025
@eddiereed5025 2 жыл бұрын
Just a comment terminal1 on actuator is heating demand terminal 3 dhw demand
@mariuszmickiewicz2956
@mariuszmickiewicz2956 3 жыл бұрын
Hi
@surinderpaulkansal6977
@surinderpaulkansal6977 Жыл бұрын
very good but bit too fast
@bayramaslan4408
@bayramaslan4408 3 жыл бұрын
hello merhaba
A detailed look at diverter valves in a boiler - Part 2
5:26
Baxi - sustainable heating and hot water solutions
Рет қаралды 56 М.
Gas Training - Sequence of operation gas boiler - Fault Finding
17:56
Wednesday VS Enid: Who is The Best Mommy? #shorts
0:14
Troom Oki Toki
Рет қаралды 50 МЛН
Как Ходили родители в ШКОЛУ!
0:49
Family Box
Рет қаралды 2,3 МЛН
Baxi Diverter How to service, Start to finish Dr Pipe.
20:34
The elbi diverter motor stripped down
6:53
Adam Carter
Рет қаралды 8 М.
Replace Diverter Valve Cartridge on a Vaillant Ecotec 832
8:06
Baxi Main Hydro Explained. Dr pipe
8:56
Dr Pipe
Рет қаралды 22 М.
Boiler Faults Find Most in 5
14:08
Mr Combi
Рет қаралды 5 М.
Heating Diverter Valve Faults SOLVED
3:39
Mr Combi
Рет қаралды 38 М.