Excellent update Mike. Just shows that sometimes the simplest way is the best way. As well as being cheaper. Thanks as always.
@BudgetModelRailways3 ай бұрын
Thanks, hope all is good with you
@OlivierGabin3 ай бұрын
Simple, cheap, efficient. I think this is an ideal solution for small layouts. And, bonus : for me, it is more "realistic" in terms of operations : on small branchlines, industrial sidings, small stations... the points are thrown by the train crews in situ, using levers besides the point you need to throw.
@JagoHazzard3 ай бұрын
You make some good points (pun not originally intended). I'm a bit of a technophobe, so anything that minimises the electrical side of things is fine by me.
@BudgetModelRailways3 ай бұрын
@@JagoHazzard same here
@forrestrobin27123 ай бұрын
@@JagoHazzard hello Jago! Fancy meeting you here 🤣
@forrestrobin27123 ай бұрын
I tried wire in tube when I was younger, but in the end invented my own method which enables me to control my points from quite a long distance. I’ve used the method ever since I had my first Super 4 layout back in the ‘70’s! Then with the very early system 6 (with a slider). Basically, it’s useable with any point which has a locking spring. For Peco I drill two small holes through the baseboard - one at each end of the tie-bar. A loop of fine fishing line over each of the end studs of the tie bar. Down through the holes in the baseboard and off to the control position of the layout where they re-emerge through holes in a fascia board and are terminated by small colour coded beads. In my case green for straight, red for curved. The natural springiness of the fishing line coupled with the centre spring on the point make for a nice positive action. Any changes of direction needed in the under board fishing line runs just need a screw in eyelet for the fishing line to run in. Thoroughly reliable and possibly even cheaper than your method, and you’re not limited to direct straight on connection to the point at the edge of the baseboard. I’ve even used it with the line/beads emerging from a mimic track diagram on the control board (though it begins to look like a giant spiders web). Just my half penny’s worth…
@BudgetModelRailways3 ай бұрын
Sounds interesting
@forrestrobin27123 ай бұрын
Now I need to find a manual method for my current Dublo vintage three-rail layout with its lovely but very manual (!) mechanical points! Someway of persuading that lovely lever to respond in both directions to a pull on some fishing line, if anyone has an idea 💡
@billsholl79043 ай бұрын
Excellent video as always and as people have said before, it's so refreshing to see a channel about model railways showing that you don't have to spend a fortune to enjoy the hobby. If not already covered I would love to see a video about where to place power supply when you have points facing different directions. Keep up the excellent work!
@BudgetModelRailways3 ай бұрын
Thanks, basically you would have to put a power feed into the other siding behind the point with an on off switch. I tend to avoid doing that with points for that reason
@davidsheriff89893 ай бұрын
Good video as I have clumsy hands and get confused by wiring. Keep it simple always works for me>
@BudgetModelRailways3 ай бұрын
It's been working very reliably, even with my ten thumbs lol
@Mokkers_stuff3 ай бұрын
Now THAT'S what I call a well used cutting mat!😅. Great video, very useful tip, thanks for uploading.
@BudgetModelRailways3 ай бұрын
You should see my large one lol
@madeinyorkshire523 ай бұрын
As expected…a very simple budget but effective solution from you! By way…re Peco points - Im building my first layout which is On30 narrow gauge and using Peco O-16.5 Narrow gauge track and 11 points. I sent my layout diagram to Peco’s technical department, and they very kindly showed me where all insulated rail joiners needed to go and all power dropper feeds. When I asked about any additional wiring needed for the points, I was told by their expert it’s absolutely not necessary! So I didn’t use any and everything seems to work fine! My layout has switchable DC and DCC options on its main loop and loco shed / siding. Still using your Budget Model Railways boxes for my PWM power module units. 👍
@BudgetModelRailways3 ай бұрын
Good to hear peco were so helpful, and confirmed about the point wiring
@ericjohnson37463 ай бұрын
Because of my bicycling background, I used Teflon lined gear brake cable housing. It's curable, but must be anchored at each end( glue works). The inner wire is picture frame hanging wire. Once I made a little bank of levers that pivoted on a threaded rod and separated with nuts. Always glad to see your work and your videos. Thank you.
@BudgetModelRailways3 ай бұрын
@@ericjohnson3746 sounds very impressive
@richardtarr27453 ай бұрын
That's a great idea for getting the points to change without messing around with point motors and all the extra wiring. My controller doesn't have an external power feed, so I'd have to find alternative power source. Fantastic if it can be sorted with 'wire-in-tube' technology. It's not great if one has a circular layout with points on the far side, but I guess it could be done. Nice helpful little video, thanks.
@steve87thpsap3 ай бұрын
Nice update on old way to do things, thanks for bringing it back.
@Curious_Skeptic3 ай бұрын
Your timing is perfect. :) Moving into a new home with a giant basement. I think for N scale, this is wonderful. Layouts are so compact, no need for machines. You touch on the reason to do this, but the biggest for me are the far side switches. Not reaching across delicate scenery to manual switch. There's also a very cool CHEAP option to do this idea, with servo and a cheap servo tester that has a nice little knob on it. You can manual make stops on the knob to limit the movement. Lots of cheap options. :) Have to check out your channel more. Been subscribed, but out of the hobby for a while.
@Jappymovies3 ай бұрын
Nice video as always! As an extra tip for those with layouts with elevation, you can make very cheap wire control for your points using brake wire cables from bicycles. Bit stiff, but can go around corners! Regarding Del Prado, I actually have one running! The French SNCF X3800 'Picasso' railcar fits in a Tomytec TM08 20m chassis with just a little bit of work. Been using it for ages like that.
@thunderccr50563 ай бұрын
This so beautifully simple, thanks for showing this. Thanks for all your efforts! Regards to all!
@BudgetModelRailways3 ай бұрын
@@thunderccr5056 thanks for the support
@MarkPurnell-er1lx3 ай бұрын
Simple is good. Nothing more to say 🤨. As always, thanks for the innovation.
@BudgetModelRailways3 ай бұрын
My pleasure 😊
@stevenjones19-m8i3 ай бұрын
Hello, another great video,I have used a wire with a tube for the points they were metal ones and they worked a treat.but your idea seems better.
@johnbeck32702 ай бұрын
This little trick works really well with Atlas HO “Snap Switches” as well as their “Custom Line. With a hole in the center of the throw bar, you can run the control rod under the layout to the turn out. Simple, quick and positive. Their N scale switches can be controlled in the same way.
@BudgetModelRailways2 ай бұрын
@@johnbeck3270 good to know thanks
@chadportenga78583 ай бұрын
Love the simplicity of it!
@steadycamman13 ай бұрын
Love the video, thank you for sharing all your tips & tricks with us all, cheers, Pete.👍
@BudgetModelRailways3 ай бұрын
Glad you enjoyed it
@dundasjunctionmodelr.r-jam82673 ай бұрын
Your way looks fantastic, excellent method
@BudgetModelRailways3 ай бұрын
Thanks
@Weesel713 ай бұрын
Nicely done. Thank you for sharing and the demonstration.
@crasher3033 ай бұрын
Interesting remote point set up. I may use drinking straws as tubes. Maybe use a wagon, or tender body to push with a del prado loco.
@anfieldroadlayoutintheloft52043 ай бұрын
great update on layout mike keep up the great vlogs you do thanks lee
@BudgetModelRailways3 ай бұрын
Thanks, will do!
@rolandcharriez76313 ай бұрын
Very clever! Simple and effective.
@BudgetModelRailways3 ай бұрын
Thank you!
@TheJpec3613 ай бұрын
Simple and effective. Of course, the "experts" will go apoplectic over it...
@BudgetModelRailways3 ай бұрын
I hope so lol
@CHOPZ-Bricks3 ай бұрын
Great idea, thank you for sharing.
@christopherbraiden6713Ай бұрын
Thanks for the video Mike, thinking about this the other night, very affective!!😎🚂🚃🚃🚃🇬🇧
@andygorman8583 ай бұрын
Fantastic wee tip on something so simple and effective. Im still using the Kato easy track with the built in point switches. They work great but you can’t really use your method to switch them. Might be time to get some Peco track me thinks 😉
@BudgetModelRailways3 ай бұрын
@@andygorman858 I love the Peco points. Peco are shorter and cheaper, both have their uses
@avlisk3 ай бұрын
Your fuel gantry "mistake" is what we refer to as a "Bob Ross". It's a happy little accident that lets you make some lemonade from lemons, AKA having fun you didn't expect to have. (I like your point control very much.)
@BudgetModelRailways3 ай бұрын
Spot on thanks
@grumbeast2 ай бұрын
Not sure about Kato chassis, but I think I’ve seen people use Tomix or Tomytec chassies with the Del Prado static locos
@gerrybeimers24692 ай бұрын
Have you done any of these in a longer version that goes under track, e.g. to points on an inner line?
@BudgetModelRailways2 ай бұрын
@@gerrybeimers2469 yes but using 3d filament as rods, and 3d printer feed tubes. These could be curved and fitted under OO track
@LondonPredatorAngler3 ай бұрын
Defo gonna do this when I make my 00 version... ❤
@BudgetModelRailways3 ай бұрын
I have a video on doing it in OO if that helps
@LondonPredatorAngler3 ай бұрын
@@BudgetModelRailways yep.seen it Mike, I watch all your video a couple of times over... seeing it again that u done it in N too, its such a great and simple way... proper old skool... im not into all this DCC etc... 👍🏻 look forward to more updates buddy
@johnhindson53163 ай бұрын
Just a thought. Well two!! Could you fill the gap between the oil terminal pltform and the backscene with something to represent some control boxes for the pipework? (Maybe simpler than a gantry?) The second thought is that fixing something like that to the backscene might be easier than attaching it to the 3d printed structure.
@BudgetModelRailways3 ай бұрын
@@johnhindson5316 thanks for the suggestions , I have a couple of options, I'm sure I can bodge something lol
@Razer_-fe9mo3 ай бұрын
I had a few of the del prado models a few years back. Not sure which would take a Kato chassis (at least without severe modification) but maybe aa tomytec EMU chassis could work?
@davetanner91333 ай бұрын
Good idea, can I ask would u attach the wire with the points set for a straight run , or if ur going off to a curve , if that makes sense rgds dave
@BudgetModelRailways3 ай бұрын
@@davetanner9133 it's trial and error I guess, if it's in a curve then a bit of wriggle room might be an idea
@davetanner91333 ай бұрын
👍
@johncourtneidge3 ай бұрын
Thank you!
@insomniacbritgaming16323 ай бұрын
I'm buildng a small layout so this would be ideal as 90% of my points are all on one side
@jenniferwhite60893 ай бұрын
2mm PVC hose buy it buy the 1000 feet of them i use it for airline air gates in milking parlors
@TerryGlover-c2m3 ай бұрын
I use unrolled paper clips with the points, as they, like yours, are on one side.
@BudgetModelRailways3 ай бұрын
Nice one
@fraserhardmetal71433 ай бұрын
Teflon 3d printer filament guide - cheap and self lubricating.
@BudgetModelRailways3 ай бұрын
@@fraserhardmetal7143 I have used that in the past
@ajivins13 ай бұрын
Your tubes look a lot like Cotton Bud stems to me. Never heard of roofing felt underlay before!
@BudgetModelRailways3 ай бұрын
@@ajivins1 we have used roofing felt very successfully for a number of years, inc at exhibitions
@ajivins13 ай бұрын
@@BudgetModelRailways And you just glue the ballast to that?
@BudgetModelRailways3 ай бұрын
@@ajivins1 I don't use ballast, that's the point of ballast mat
@ajivins13 ай бұрын
@@BudgetModelRailways It doesn't just stay that shiny black though?
@BudgetModelRailways3 ай бұрын
@@ajivins1 yes, although if I can get it I use grey roofing felt which is better