Charging R-410A Refrigerant Into An Air Conditioner Using Wireless Probes!

  Рет қаралды 21,068

AC Service Tech LLC

AC Service Tech LLC

11 күн бұрын

In this HVAC Training Video, I Show How to Use Wireless Probes to Check the Refrigerant Charge and How to Correctly Charge R-410A Refrigerant into this Running Air Conditioner! Technicians Must be EPA 608 Certified to Handle Regulated Refrigerants! Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
Tools Used In The Video:
Fieldpiece Complete Job Link Probe Kit - trutechtools.com/Fieldpiece-C...
Fieldpiece STA2 Thermal Anemometer Hotwire AirFlow Meter trutechtools.com/STA2?aff=8
Hilmor RSWL220 Wireless Refrigerant Scale 220lbs trutechtools.com/hilmor-rswl2...
At Trutechtools.com use code acservicetech for 8% off
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our Related Videos:
• Charging R-410A into a...
• Charging an R-410A AC ...
• R-410A Charging and Re...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
All Our Educational Products on Our Site: www.acservicetech.com/store
All Our Educational Products on Amazon: amzn.to/48pDd82
Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-sp...
Mini Split Paperback on Amazon- amzn.to/3ytHJSs
Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGui...
Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Online Resources!
Our HVAC Calculators: www.acservicetech.com/hvac-ca...
Our Newest Articles: www.acservicetech.com/articles
Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
Our Other Resources: www.acservicetech.com/resources
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Tools Used in Our Videos!
Tool Links on Our Site: www.acservicetech.com/tools
Our Tool List on Amazon: www.amazon.com/shop/acservice...
Support the Channel by purchasing tools through Tru Tech Tools!
Use this link www.trutechtools.com/?aff=8
Save 8% at checkout using code "acservicetech"
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Follow Us On Our Social Media & Podcasting Channels!
Patreon: / acservicetech
Facebook: / acservicetech
Instagram: / acservicetech
X: / acservicetech
LinkedIn: / ac-service-tech-llc
Tiktok: / acservicetech
Spotify: open.spotify.com/show/74KXLz5...
Apple Podcasts: podcasts.apple.com/us/podcast...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
⚠️ Disclaimer:
Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided.
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
#hvacr #hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #hvactechs #technician #training #airconditioner #airconditioning #r410a #charge #checkingthecharge #refrigerant #refrigerantcharging
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Shop through Amazon! Your purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Пікірлер: 77
@deanmartin1966
@deanmartin1966 6 күн бұрын
I'm sure I've said it before, but thanks for all the great free information you and all the other great teachers provide. Such a wealth of knowledge. I'm 58 and I absolutely hated high school. Until I got into the trades. Then surprisingly I became an "A" student. I seriously love the trades and think its a great alternative to a four year college. My grand daughter is 15 and wants to become a welder. She makes me proud. Once again, thanks. Phil
@electrolatif
@electrolatif 9 күн бұрын
The best aircon video in KZbin ❤
@deanmartin1966
@deanmartin1966 10 күн бұрын
Excellent video Craig. I do love my fieldpeace probes.
@manueldacosta6539
@manueldacosta6539 10 күн бұрын
Excellent video as always, thank you.
@zahedaminullah6934
@zahedaminullah6934 10 күн бұрын
Great video man!
@paulrmfd
@paulrmfd 8 күн бұрын
absolutely instructional keep up the good work
@jorgemanzano7232
@jorgemanzano7232 10 күн бұрын
Well explained! Thank you very much 😊
@TheWathever516
@TheWathever516 10 күн бұрын
Great video!
@snwsk8
@snwsk8 2 күн бұрын
Great tips as always, thank you
@AndyHoltOutdoorUniversity
@AndyHoltOutdoorUniversity 3 күн бұрын
Nice job, Craig!
@gingerstrand6153
@gingerstrand6153 9 күн бұрын
Great video, thank you!!
@repairitdontwreckit4257
@repairitdontwreckit4257 9 күн бұрын
Thanks. Nice job.
@kennethlobo4420
@kennethlobo4420 10 күн бұрын
Well explained ❤
@APHVAC0913
@APHVAC0913 10 күн бұрын
Great video 👌🏽
@butlerstouchHVAC
@butlerstouchHVAC 10 күн бұрын
great vid
@kastenusa
@kastenusa 10 күн бұрын
Can you please make a video on where to connect probs on package unit correctly. Thank you!
@cryptkeyper
@cryptkeyper 10 күн бұрын
I second this
@yannkitson116
@yannkitson116 10 күн бұрын
Great video, I have Testo probes and a slightly different app but it is all the same in the end :)
@edwardlouie
@edwardlouie 9 күн бұрын
I like using core depressors so I don't need to spin on/off quickly.
@mohdrifi1930
@mohdrifi1930 10 күн бұрын
Excellent! You need to do this method to ac split unit also! Appreciate your effort teacher! ❤️❤️❤️❤️
@cryptkeyper
@cryptkeyper 10 күн бұрын
This is a ac split unit
@jericosha2842
@jericosha2842 9 күн бұрын
This doesn't work on mini split ductless if that's what you mean
@pongobongo2295
@pongobongo2295 10 күн бұрын
Use Appion charging tees. This is my go to charge set up. Also, get a third probe and map to outdoor air temp.
@mtbbiker6401
@mtbbiker6401 9 күн бұрын
I don't understand how taking a low pressure (vapor line) reading at the condenser translates to the pressure in the evaporator. Why is it not industry standard to take low pressure (vapor line) reading at the evaporator?
@lorunner1213
@lorunner1213 6 күн бұрын
Craig. Does the outdoor Dry bulb temp matter if being read from the sunny side of the condenser vs the shady side?
@vonboldler5219
@vonboldler5219 9 күн бұрын
Hi mike!
@arthurrabon9349
@arthurrabon9349 Күн бұрын
multi zone split unit question. if you have 3 zones and 1 zone is having troubles meeting set temp. how does system respond.
@JuanJuarez-en5xn
@JuanJuarez-en5xn 5 күн бұрын
Where can I buy those T’s that go on your probes do you have a link to them ?
@NickNameNemo
@NickNameNemo 14 сағат бұрын
If system has leakage (r410a) and still remains some amount of refrigerant, let’s say 70-80% of total, should I recover all refrigerant from system and charge it with new or just add needed amount?
@povoljan13
@povoljan13 7 күн бұрын
The charging hose has air when you hooked it up to the tee. The small space after the shutoff valve is dead air space. Needs a better setup maybe?
@globecomputers1
@globecomputers1 10 күн бұрын
Great video! Like always! Question can you provide a link for those AC test caps? I need to buy a set.
@HVAC_Tips_Tricks_Calcs
@HVAC_Tips_Tricks_Calcs 8 күн бұрын
Just take two spare caps and drill a hole in them.
@justinhughes452
@justinhughes452 9 күн бұрын
What was the recommended amount of refrigerant on the name plate? How much was in system at the start and what was the total amount at the rnd of this demonstration?
@pana5075
@pana5075 10 күн бұрын
Espero este video en español
@mikev.1034
@mikev.1034 10 күн бұрын
👍👍
@pitaeata8493
@pitaeata8493 10 күн бұрын
need tips and tricks to determine if a system has a piston or txv. Sometimes on UNCASED coils it is impossible to remove the front of the field made cover to get a look.
@sir.cannabis1173
@sir.cannabis1173 9 күн бұрын
I'm thinking one could tell by how fast the numbers move. Craig mentioned it might take 15 minutes for pressures to equalize with a fixed.
@mackenziegray2090
@mackenziegray2090 9 күн бұрын
If you see a threaded union outside the case, chances are you got a piston.
@turnedearthdesign8678
@turnedearthdesign8678 4 күн бұрын
Also check the chart on the condenser. It usually (but not always) tells you what the pressure of one of the lines should be which should match up to the metering device used
@monstaro19
@monstaro19 Күн бұрын
We need a way to use this in cars its 106 in Florida
@Ahmed198831
@Ahmed198831 9 күн бұрын
🙏🙏🙏🙏
@wpl11972
@wpl11972 10 күн бұрын
I just use my valve core removal tool as my tee.
@emidiolopez1409
@emidiolopez1409 9 күн бұрын
So you remove the schrader valve to do SH or SC? Or what kind of removal tool do you use that has a press tool built in? Because the Appion that I use don’t have the press tool so I can’t take any risk of losing 5+ pounds of refrigerant by removing the schraders lol
@HVAC_Tips_Tricks_Calcs
@HVAC_Tips_Tricks_Calcs 8 күн бұрын
@@emidiolopez1409if your loosing 5 lbs with a core removal tool you’re using it wrong. How much refrigerant are you going to lose I’d the schrader doesn’t seal?
@emidiolopez1409
@emidiolopez1409 8 күн бұрын
@@HVAC_Tips_Tricks_Calcs Ive never said I’m losing 5 pounds by using the schrader removal tool. I said that’s just stupid if you have to remove the schrader valves every time you have to check the pressures on an AC, NO way I’m taking risks in losing factory refrigerant if something doesn’t goes bad with the removal tool.
@jimwhite9483
@jimwhite9483 8 күн бұрын
How hard would it be for Fieldpiece to add a wireless input for ODDB in the app or on the SMAN 380V?
@turnedearthdesign8678
@turnedearthdesign8678 4 күн бұрын
You can link one of their psychrometer probes to the outdoor dry bulb
@davidlopan6649
@davidlopan6649 9 күн бұрын
I can see myself pulling the pressure probes off the T and accidentally letting out all the refrigerant. lol definately would put a valve core on that for me.
@lorunner1213
@lorunner1213 6 күн бұрын
I use apion tee’s. They are low loss with schraders on both male ends of the tee. So doesn’t matter if you pull just the probe off. Or the tee with the probe.
@davidlopan6649
@davidlopan6649 5 күн бұрын
@@lorunner1213 Yeah I love appion tools. Just purchased their recovery machine. I didn't get probes yet probably next year.
@JuanJuarez-en5xn
@JuanJuarez-en5xn 5 күн бұрын
Where did you bought those T’s ?
@lorunner1213
@lorunner1213 5 күн бұрын
@@JuanJuarez-en5xnJohnstone Supply
@JuanJuarez-en5xn
@JuanJuarez-en5xn 10 күн бұрын
Can you make a video on RTU’S?
@mackenziegray2090
@mackenziegray2090 9 күн бұрын
It's the samething. What part confuses you?
@HVAC_Tips_Tricks_Calcs
@HVAC_Tips_Tricks_Calcs 8 күн бұрын
Although I’m sure sponsored, nice to see someone make a video that didn’t say you had to use MQ and True Flow or you’re a hack.
@tomaszpoznanski7584
@tomaszpoznanski7584 10 күн бұрын
Iam a contractor and would like to do a course/training for a/c contractor. Can you recommend any in NY/NJ/PA area? Any schols?
@edwardlouie
@edwardlouie 9 күн бұрын
This method doesn't always work with inverter variable speed equipment that change the superheat target based on various logics.
@HVAC_Tips_Tricks_Calcs
@HVAC_Tips_Tricks_Calcs 8 күн бұрын
Inverters usually don’t have fixed orifices.
@Bigdawg_74
@Bigdawg_74 9 күн бұрын
sadly most techs will hook up and immediately say it's good or needs refrigerant because companies are so focused on getting techs in and out as fast as possible. Most expect a complete diagnosis to be complete in 30 min max preferably less.
@TheRealDegen100
@TheRealDegen100 6 күн бұрын
Preferably way less but every call is different. Only calls that really take time is determination of why a part failed.
@hazendismukesjr.8319
@hazendismukesjr.8319 9 күн бұрын
😂why didn't you use a charging orifice
@kevinpearce3281
@kevinpearce3281 10 күн бұрын
Why can’t you put the r410a into the liquid side if it’s coming in as a liquid
@davidgochenour7072
@davidgochenour7072 10 күн бұрын
It would push refrigerant into your bottle
@camilo8cheryl
@camilo8cheryl 10 күн бұрын
High pressure
@WhatIsYourCard
@WhatIsYourCard 10 күн бұрын
The liquid side is at a high pressure while the system is running. Connecting the refrigerant jug to the suction line, which is a lower pressure, will suck the refrigerant into the system.
@wyattdekay7763
@wyattdekay7763 10 күн бұрын
Usually to much pressure
@boongoon92
@boongoon92 10 күн бұрын
It's leaving as a liquid
Explaining Superheat and Subcooling to Your Apprentice!
14:14
AC Service Tech LLC
Рет қаралды 582 М.
"Flammable" Refrigerant Facts for Residential HVAC
1:02:01
HVAC School
Рет қаралды 36 М.
3M❤️ #thankyou #shorts
00:16
ウエスP -Mr Uekusa- Wes-P
Рет қаралды 13 МЛН
ОДИН ДЕНЬ ИЗ ДЕТСТВА❤️ #shorts
00:59
BATEK_OFFICIAL
Рет қаралды 9 МЛН
MINI SPLIT Parts Explained! Understand What They Do!
19:31
AC Service Tech LLC
Рет қаралды 614 М.
Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips!
27:56
AC Service Tech LLC
Рет қаралды 1,4 МЛН
3 PROVEN Methods To Getting Colder Air From HVAC Vents.
10:45
The DIY HVAC Guy
Рет қаралды 266 М.
Digital HVAC Gauges or Wireless Probes | Which should YOU buy??
17:00
Troubleshooting With Sat Temps, Superheat, & Subcooling! 5 Possible Problems!!
18:48
How To Add Refrigerant To Air Conditioner
22:08
Word of Advice TV
Рет қаралды 1,7 МЛН
Where to Find R-22 & R-410A LEAKS on AC Units! Top 10 Spots!
14:46
AC Service Tech LLC
Рет қаралды 192 М.
This New HVAC Tool Is A GAME CHANGER.
5:57
The DIY HVAC Guy
Рет қаралды 91 М.
I HATE Mitsubishi MiniSplits
15:41
HVACR Survival
Рет қаралды 120 М.
3M❤️ #thankyou #shorts
00:16
ウエスP -Mr Uekusa- Wes-P
Рет қаралды 13 МЛН