This is an Easy Follow, STEP BY STEP PROCESS for R-410A AIR CONDITIONERS on how to Connect the Gauges, Measure if the Charge is Too Low, Right On, or Overcharged, How to Disconnect the Hoses and Gauge Set and How to Make Sure that the Valves on the System are Sealed so all of the Refrigerant Does Not Leak Out! Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
Tools Used In This Video
Yellow Jacket Refrigerant Gauge Set - amzn.to/2aenwTq
Refrigerant hoses with valves - amzn.to/2aBumVI
UEI DL389 Multimeter amzn.to/2xAdaJf
Magnet Jumpers- amzn.to/2PyKPQZ
Alligator Jumpers- amzn.to/2PxqJXn
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our Related Videos
• R-22 and R-410A Operat...
• Charging an R-410A AC ... R-410A
• R-410A AC Unit, Checki...
• Checking the Refrigera...
• R-410A Charging and Re...
• Charging R-410A Refrig...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
All Our Educational Products on Our Site: www.acservicet...
All Our Educational Products on Amazon: amzn.to/48pDd82
Mini Split Book and E-Book on Our Site- www.acservicet...
Mini Split Paperback on Amazon- amzn.to/3ytHJSs
Mini Split Paperback on TruTech Tools- www.trutechtoo...
Refrigerant Charging Book and E-Book: www.acservicet...
Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Online Resources!
Our HVAC Calculators: www.acservicet...
Our Newest Articles: www.acservicet...
Try our HVAC/R Quizzes! www.acservicet...
Our Other Resources: www.acservicet...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Tools Used in Our Videos!
Tool Links on Our Site: www.acservicet...
Our Tool List on Amazon: www.amazon.com...
Support the Channel by purchasing tools through TruTech Tools!
Use this link www.trutechtoo...
Save 8% at checkout using code "acservicetech"
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Follow Us On Our Social Media & Podcasting Channels!
Patreon: / acservicetech
Facebook: / acservicetech
Instagram: / acservicetech
X: / acservicetech
LinkedIn: / ac-service-tech-llc
Tiktok: / acservicetech
Spotify: open.spotify.c...
Apple Podcasts: podcasts.apple...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
⚠️ Disclaimer:
Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided.
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
#hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #r410a #airconditioner #airconditioning #measuring #measurement #low #procedure #hvacprocedure #refrigerant #r410a #disconnect #stepbystep #acunit
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Пікірлер: 182
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Our Inverter Mini Split Resources: Mini Split Book on Our Website- www.acservicetech.com/mini-split-book Mini Split Paperback on Amazon- amzn.to/3ytHJSs Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGuides?aff=8 Mini Split E-Book on Google- play.google.com/store/books/details?id=HN-iEAAAQBAJ Mini Split E-Book on Apple- books.apple.com/us/book/id6445178399 Our Single Speed and Two Speed Air Conditioning Resources: My Paperback and E-Book: www.acservicetech.com/the-book My Paperback: www.amazon.com/shop/acservicetech Read the book reviews on Amazon! Check out our new Articles at www.acservicetech.com/articles Support the Channel by purchasing tools through Tru Tech Tools! Use this link www.trutechtools.com/?Aff=8 Save 8% at checkout using code "acservicetech" Tool List- www.amazon.com/shop/acservicetech Support- www.patreon.com/acservicetech For those that are looking for the tools used in the videos: (Linked Below) Here is the Link for the Yellow Jacket Refrigerant Manifold Gauge Set used in the videos- amzn.to/2aenwTq Here is a link to Refrigerant hoses with valves used in the videos- amzn.to/2aBumVI Here is the Link for the newer UEI DL479 Multimeter with temp sensor- amzn.to/2jtsUbJ Here is the Link for the newer UEI DL469 Multimeter- amzn.to/2jw4ePJ Here is the Link for the UEI DL389 Multimeter used in the video - amzn.to/2naJr9o Here is a link to the Imperial 535-C Kwik Charge Vaporizer for Charging Refrigerant- amzn.to/2wFHtBW Here is the link to the Fieldpiece ST4 Dual Temp Meter- amzn.to/2wc1ME3 Here is a link to the Digital Refrigerant Scale used in the videos- amzn.to/2b9oXYl Here is a link for RectorSeal Bubble Gas Leak Detector amzn.to/2ckWACn Other tool links can be found in the video description section. ACSERVICETECH is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon. Check out other videos on the HVACR topics of interest at- kzbin.info/door/OZR-1IqsAer9wzlvFgb4mAplaylists?view_as=public If you want to support the ACSERVICETECH Channel and receive more HVAC content, check out www.Patreon.com/acservicetech
@jonwz
@jonwz 6 жыл бұрын
Love your vids, but I question your technique attaching lines to the system. The high pressure test line should be connected when the system is OFF, the low pressure test line should be connected when the system is ON. Puron costs us consumers 50 dollars a pound. My last tech vented enough 410A to really piss me off (and then claimed I needed to pay for a puron charge).
@charlieb8417
@charlieb8417 5 жыл бұрын
if suspected low refrigerant should you check with bubble Leak Detector even before removing caps? and then again after removing caps before attaching gauges? isn't the schrader valve the most prevalent cause of slow to very slow refrigerant leaking?
@tom20152
@tom20152 5 жыл бұрын
Is the AC system should be ON or OFF while charging?
@eazypeezy6195
@eazypeezy6195 3 жыл бұрын
I’m a new tech, my journeymen is amazing, but when I’m outside of work I watch your videos. Knowledge is power!
@michaelbrewer1474
@michaelbrewer1474 7 жыл бұрын
Hand's down the best educational HVAC video's on KZbin!! Thank you!!
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Thanks a lot Michael, I appreciate it!
@sirvaant
@sirvaant 6 жыл бұрын
Michael Brewer agreed!
@vjnblnum2303
@vjnblnum2303 5 жыл бұрын
All the dislikers of this quality and informative video/s of this knowledgeable professional AC Technician are "basic attention seekers" they have absolutely NO credibility to underate someone's hard work which they know nothing about.
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Ha ha, thanks a lot Vjn! I appreciate it!
@stanleykania7184
@stanleykania7184 Жыл бұрын
Thank you
@deancurtis5992
@deancurtis5992 8 жыл бұрын
Thank you for this series! I'm just learning about HVAC so I can be better informed when I call a tech, and these are most helpful!
@acservicetechchannel
@acservicetechchannel 8 жыл бұрын
Glad to help!
@hollidaydoc45
@hollidaydoc45 Жыл бұрын
Do you need multiple vaporizers for each different refrigerant that you will be using or is there not enough oil that would cause a problem with the different refrigerants?Thanks.
@lukebrietzke8514
@lukebrietzke8514 4 жыл бұрын
When you connected the hoses to the system you didn’t purge the air on the low and high side
@P9rkour90
@P9rkour90 2 жыл бұрын
Whoops?
@lukebrietzke8514
@lukebrietzke8514 2 жыл бұрын
@@P9rkour90 ya boi
@P9rkour90
@P9rkour90 2 жыл бұрын
@@lukebrietzke8514 damn lol
@lukebrietzke8514
@lukebrietzke8514 2 жыл бұрын
@@P9rkour90 you worked with CO2 yet? No recovery no evacuation no purge needed. Normal suction pressure on a cooler is like 350 ish. Head pressure can be up to 1,400.
@billkrebs2307
@billkrebs2307 8 жыл бұрын
Great video. Especially appreciate showing how to recycle the gas in manifold hoses!
@acservicetechchannel
@acservicetechchannel 8 жыл бұрын
No problem, glad to help!
@nutsandbolts8308
@nutsandbolts8308 6 жыл бұрын
Bill Krebs i
@realestateinfonet9041
@realestateinfonet9041 2 ай бұрын
Superb info! Thanks!
@walterbrunswick
@walterbrunswick 7 жыл бұрын
You should connect a little stubby hose (6" or 12") between the gauge manifold and the Kwik Charge on the low side to put less strain on that 1/4" male flare. Would make it easier to handle as well.
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Thanks
@user-bj4lp3fr1o
@user-bj4lp3fr1o 3 жыл бұрын
Can you take the yellow hose off the manifold and add a cap to the manifold where the yellow hose originally connected? That would avoid having air or refrigerant in the yellow line.
@legoguy2554
@legoguy2554 2 жыл бұрын
Thanks just got a job this really helps
@acservicetechchannel
@acservicetechchannel 2 жыл бұрын
That is awesome to hear! Thanks for letting me know and check out some of the articles on superheat and subcooling on our website at www.acservicetech.com thanks!
@japalian8082
@japalian8082 2 жыл бұрын
Intro kills me
@dianalfredalonzo6645
@dianalfredalonzo6645 4 жыл бұрын
just got that kwik charge tool. thanks
@mon0theist_tv
@mon0theist_tv 2 жыл бұрын
What's that thing connected to your blue hose on the manifold? Oh nvm you answered that 😉
@HowToDoitright
@HowToDoitright 3 жыл бұрын
Hi great video. Question. What if subcooling is low and you add 410a and the head pressure increases but your liquid line temperature also increases? This way you will never reach the proper subcooling (txv system). What’s that indicating?
@derekwagstaff9279
@derekwagstaff9279 2 жыл бұрын
Ensure proper airflow and no refrigerant restrictions before getting your target anything
@gojooyoung
@gojooyoung 3 жыл бұрын
So did you basically return all trapped liquid refrigerant trapped in the connector to the vapour side?
@piezomotor
@piezomotor 2 жыл бұрын
Hello, thank you for this video. I have a question - my R22 bottle has the red and the blue valves but my R22 manifold has the yellow input house. Do you know by any chance where I connect the yellow house, to the red or the blue valves?
@MichaelREFLECTS
@MichaelREFLECTS 6 жыл бұрын
@acservicetech are you running the AC while disconnecting? Wouldn't that shoot out refrigerant from the liquid line (higher pressure) to the environment? Also what do you do if when you disconnect a liquid line with the system off - a lot of refrigerant shoots out?
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Yes you could wait five minutes for the unit the equalize and then disconnect the red but if you are doing the disconnect process then you would be loosing much less refrigerant anyway since you are charging refrigerant from the red back into the blue after disconnecting, thanks
@scottm3552
@scottm3552 3 жыл бұрын
I noticed you didn't purge the liquid hose upon connection. Could that of caused a different pressure reading? 2. If i wanted to add refrigerant using the low side if i was using r410a, I would put the kwik charge device directly on the refrigerant tank upside down; while the liquid valve on the gauge was closed. correct?
@mark.r8900
@mark.r8900 2 жыл бұрын
Hi, what if the saturation temp on the low side is around 20F. And adding more refrigerant only increase the subcooling. Could this be a bad txv? Thanks
@kevinkevin9448
@kevinkevin9448 4 жыл бұрын
Great video what would u do if u did know how many feet of line set is on a mini split ?? Would u do subcooling method does your book explain it ??
@l.crossjr
@l.crossjr 7 жыл бұрын
Great info and very good videos
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Thanks Extrangulador DelRio!
@alchemyphilosophersstone2634
@alchemyphilosophersstone2634 7 жыл бұрын
Great video
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
thanks again!
@ba177ba18
@ba177ba18 4 жыл бұрын
is your condenser on during the refilling procedure?
@A-bone
@A-bone 3 жыл бұрын
Yes
@halleffect1
@halleffect1 5 жыл бұрын
what happens if you charge a 410 system with the tank upright, vapor only?
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
The refrigerant will not be as efficient and the bottle of refrigerant should not be used any more because the mix is off, thanks
@phillipborbon2059
@phillipborbon2059 5 жыл бұрын
I've been taught differently in school, we charge with the high side, and recover on the low.
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
The only way you would do that is if the system was off and you were breaking the vacuum with liquid refrigerant into the empty and vacuumed liquid line. You can recover by pulling from both sides while the unit is off. In this video the system was running so refrigerant would need to be added into the low pressure side slowly, thanks!
@phillipborbon2059
@phillipborbon2059 5 жыл бұрын
@@acservicetechchannel late reply but yes. Was trying to find a video of yours while I was doing practicle in class.
@progressplumbing5203
@progressplumbing5203 5 жыл бұрын
When you put the remaining refrigerant in hose to suction , do you have to have a system operating if i don't have the kwik charge .
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Yes the system needs to be running and charge very slowly into the low side of the system if you dont have a kwik charge, thanks!
@ATH24TXEX
@ATH24TXEX Жыл бұрын
Question for you Craig (or any other techs who can chime in) about that Imperial 535-C Kwik Charge: I just bought one off Amazon and the label on mine is pointing the opposite way. The "Flow" direction points from the male threaded end toward the female end (just opposite of yours and all the others I've seen online). Bought it brand new in sealed package, so it has not been tampered with. Not sure if the label is just backwards or if perhaps the end caps are flipped around, as I know they can be swapped side to side. When I blow low pressure air through it from the female side toward the male threaded end, no air passes through it... when I apply the same low pressure air in the opposte direction, from the male threaded end toward the female end, the air passes through it freely. Which way is correct? Trying to determine if the label was just put on wrong or if these end caps are on the wrong ends. First time using this particular item, so I'm trying to make sure mine us set up correctly, as something obviously isn't right with it as is. Really appreciate your videos, btw... they are superbly done.
@ronaldcach2779
@ronaldcach2779 6 жыл бұрын
Hi, what do you do with the refrigerant left in your gauge set lines? THANKS FRIEND
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Look up acservicetech disconnect procedure. I show this with 3 position valves and schrader valves. Basically you charge the liquid back into the vapor side after disconnecting the liquid gauge so the amount that is left in the gauges is only a very small amount of vapor. That would be de minimis. Thanks Ronald!
@jackoesterlejr.3454
@jackoesterlejr.3454 6 жыл бұрын
Outstanding video's!
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks Jack!
@jimbola77
@jimbola77 8 жыл бұрын
love your video's!!!
@acservicetechchannel
@acservicetechchannel 8 жыл бұрын
Thank you!
@paulrozinski1488
@paulrozinski1488 4 жыл бұрын
Hi: Love all your videos. One question though. At the end of the disconnect procedure there is still some pressure in the gauge set. What are you SUPPOSED to do with that residual pressure??? I know that it can’t stay there. Keep your book inside my AC tool kit. Thanks again !!!!
@Froggability
@Froggability 4 жыл бұрын
Paul Rozinski . Release..
@dirtydan678
@dirtydan678 4 жыл бұрын
De Minimus, just let it go to the winds
@mhdzakimlr7573
@mhdzakimlr7573 3 жыл бұрын
Mate, technically there is remaining gas in side the manifold gauge after he turn off the fittings connector at both yellow red hose and plug off both of it. To make it's empty, blue hose need to be remain attached to the compressor unit and during this process, the compressor unit need to remain on, so the balance gas inside the manifold gauge and hoses will be suck to the compressor unit automatically. Reading at the manifold gauge is still active because there was a pressure suction caused by the compressor unit while it's running.
@grzegorzewskim
@grzegorzewskim Жыл бұрын
I had noticed there were pressures still left in each gauge, what would be the proper way to bring both gauges back to no pressure?
@parkerpasternack206
@parkerpasternack206 Жыл бұрын
The refrigerant that is left in the gauges is ok to release. It is called De minimis release and EPA allows it
@kennethyaker3820
@kennethyaker3820 7 жыл бұрын
appreciate VDO, I went to hook up gauges but found that on vapor line there was a valve so ok!!!!!!!!!! BUT on liquid line there is a a valve inside which takes an allen key. PLEASE ADVISE
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Does the port have a schrader valve? Typically the valves with the allen key are not king valves and do have a schrader attached in the 1/4 connection for the hose. It is the square stems that are king valves which require mid seating to get refrigerant from the line valve to the 1/4" connection port -- kzbin.info/www/bejne/m4nOooKJlNasrdE -- kzbin.info/www/bejne/j5XYYXVplLyeqdU
@frankroper3274
@frankroper3274 5 жыл бұрын
Great video but since the unit was in use and was running on a low charge, I didn't understand why you didn't add the freon.
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
This was just a testing unit we use at the shop that I teach off of, thanks!
@deloct
@deloct 8 жыл бұрын
Thanks for sharing. I really appreciated the time you take to explain proper way of how to work or service ac system. Thanks.
@acservicetechchannel
@acservicetechchannel 8 жыл бұрын
No problem, I am glad you enjoyed it! Thanks for your Comment!
@enduringpromise
@enduringpromise 6 жыл бұрын
Love the videos. Question, when you bled the yellow line was that from the front of the gauge set or the rear. If it was from the front side it seems that the yellow hose was left with air in the line. I would assume that you would bled from the backside so the whole yellow line is bled. Did I miss something?
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Yes you should bleed the air from the other end of the yellow hose where the valve is attached to the hose, thanks
@ranimouf
@ranimouf 7 жыл бұрын
Was the unit on all the time when you were doing all these procedures.
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Yes, my mic cancels out background noise, thanks Rani!
@jhontejada5773
@jhontejada5773 7 жыл бұрын
I appreciate all of your actual teachings, can you please tell me the model of clamp meter with thermometer? tnx
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Hey jhon, Here is a link to the UEI DL389 Multimeter used in the video amzn.to/2av8s3q
@robertdestefano9759
@robertdestefano9759 7 жыл бұрын
HI and ty for the info & the easy to understand video's , I have a question about the manifold and the hoses used in charging liquid R410a . Am I rite in the thinking, all the hoses , at the end will be filled with liquid ? And if correct would it be ok to empty them into the low side slowly as well ? Thanks
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Absolutely as long as the hose red hose has air purged too. Here is the video on that- kzbin.info/www/bejne/sHvQi3uwgdykmNU
@jet5069
@jet5069 4 жыл бұрын
Hi Sir, where did you connect the hose on the condenser side or in the compressor side. thanks for the response.
@phreetwoaim1
@phreetwoaim1 6 жыл бұрын
Great Video, really informative !
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks Phree!
@jcstudios5629
@jcstudios5629 4 жыл бұрын
Number 1. What's with you AC guys always using bubbly to check leaks? I bought a wand style Freon detector for $21 off Amazon and it works great and I'm not an AC guy. 2. Great demo, but you're using hoses with cut off valves on the end, which explains why you didn't purge the lines when you hooked them up? 3. Back to number 2, if your hoses don't have valves on them, you have to first hook them up with the system off so the suction line doesn't suck in air on the blue line using no cut off valve hoses, next purge out the air, then turn on the system, correct?
@HowToDoitright
@HowToDoitright 5 жыл бұрын
Can I use the same hoses and gauge for R22 if I have used it for 410a in the past or vice versa ?
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Most of us have 2 to 3 sets in the truck, one for each refrigerant we mainly work with due to the oil but yes it can be done if you are starting out and only have one set. You can also blow them out with nitrogen to rid any excess oil in the hoses, thanks
@ronaldcach2779
@ronaldcach2779 5 жыл бұрын
Hi, I noticed you left pressure on your gauges, after you disconnected them. Do you leave that refrigerant in your gauges? Or do you bleed them off, before you connect to the next unit. THANKS FRIEND Great video
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
That small amount of vapor would be considered diminimus and could be bled off, thanks
@gloiban
@gloiban 7 жыл бұрын
a.c. service tech, what's the best way to recover refrigerant from a condenser that had been pumped down and cut out? if i open the valves refrigerant will fly out...are u supposed to braze the lines shut first, I have never done this so I would like your advise, thank you a.c. service tech
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Yes, you got it, braze the ends shut first, thanks
@psiman84
@psiman84 4 жыл бұрын
I don’t understand how you got all the air out of the yellow light by just cracking it. Isn’t there technically still air in that yellow line ?
@Froggability
@Froggability 4 жыл бұрын
Psi Man. I release the tail end of yellow hose, Not the front. To guarantee air is out. Esp since the final suck down will take that air into the machine. As shown in the video
@ChumpyChicken2
@ChumpyChicken2 7 жыл бұрын
God dam! Your intro is a killer to my ears with headsets
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Yeah I changed it since then and youtube won't allow me to change it on those older videos, sorry about that, thanks!
@MikeKokoschka
@MikeKokoschka 7 жыл бұрын
If I don't have the quick charge connector(which change liquid into gas), it is ok to just turn the unit off and charge the R-410 as a liquid in the high pressure side..?
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
This video shows weighing in liquid into a vacuumed system. - kzbin.info/www/bejne/pJTKfXePp9uBbNk - You can't add refrigerant into a system that is off with refrigerant already in it. The sat pressure in the bottle will be the same as the saturated pressure in the system. Some people just meter the liquid in extra slowly by the handle instead of with the kwik charge 535-c. I love that kwik charge but it can be done slower without it. Thanks Michael Kokoschka!
@ajabusamra3901
@ajabusamra3901 5 жыл бұрын
What if my mini split condenser has a low side port but none of the 4 line sets have a place to connect the high side gage!??? Cofounded by this thermocore unit..
@MichaelJeffers75
@MichaelJeffers75 5 жыл бұрын
Is using the thermocouple and meter critical for charging up a mini split?
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Minisplit is done with the total weight method since they don't give us charging guidelines for vrf compressors, thnaks!
@jamespaquette3791
@jamespaquette3791 7 жыл бұрын
First year apprentice! Subbed!!
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Thanks James, awesome to hear you have entered the trade!
@rohailsiddiqui730
@rohailsiddiqui730 6 жыл бұрын
Why the Liquid line become cold and vapor line are normal.(not Cold) in 410A system after relocate the unit.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Is the unit a heat pump running in heat mode?
@userjim9
@userjim9 4 жыл бұрын
Just bought kwik charger, is it normal to have a metal rattle when moving it around?
@wenjunli2006
@wenjunli2006 3 жыл бұрын
how about clean the Shirader valve using paper towel after leaking testing?
@leocruz3037
@leocruz3037 6 жыл бұрын
Thanks! Did you put the refrigerant back with the compressor running? excellent!
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Yes I put all of the liquid back in. Thats what I wanted to show everyone. Put the high side refrigerant back into the low side before disconnecting, thanks
@tonymoran9794
@tonymoran9794 7 жыл бұрын
Should the unit be on or off when connecting or disconnecting? Does it matter? I recently put my gauges on a 410A system and I guess I had a lot of pressure built up and it blew the gasket off the hose when I disconnected it and lost a bit of refrigerant too. I probably didn't take the hose off correctly also. (only the 2nd time I hooked up hoses.)
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Look up "acservicetech disconnect procedure" for weighing the liquid from the disconnected red line into the low side of the system while running. Thanks Tony!
@estrellarobert4925
@estrellarobert4925 7 жыл бұрын
thanks alot michel for the video ser iwant to learn air conditioning technician
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
That is awesome to hear! I would start off by trying to get a less expensive training such as a county technical high school that does Adult evening classes at night and trying to get your foot in the door at a local company, if possible, thanks
@litewavve
@litewavve 7 жыл бұрын
Sorry I am missing something. How do you determine when to stop charging? You took off the liquid line during charging, and never put it back to confirm the if the super cooling temperature has reached. So how did you know by the vapor gauge alone?
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
The reason is because in this video I did not add any refrigerant but only checked the charge and then put the liquid back in. If you were adding liquid refrigerant then I would have a full yellow service line too and could accidentally overcharge if I stopped charging right at the correct subcooling and then performed the disconnect procedure. Thanks!
@litewavve
@litewavve 7 жыл бұрын
Oh, that's right. The yellow line connected to nothing. I was thinking you were recharging the system. It now makes perfect sense to me. Thanks.
@Alberto-by7zq
@Alberto-by7zq 6 жыл бұрын
When adding refrigerant from the hoses to the unit, do you have to do anything different if your hoses don't have those shutting valve at the end?
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
It is more about loosing a lot of refrigerant when disconnecting more than anything else. You could purchase valve connectors for the end of the hoses. I have them linked here- amazon.com/shop/acservicetech , thanks
@Alberto-by7zq
@Alberto-by7zq 6 жыл бұрын
Awesome, that was a quick response, thank you! On another issue, I connected my brand new YJ set to my unit (410a w/interior TXV) in order to find subcooling (9 degree per unit label). My high side gauge went all the way up to 250 psi where it settled. However, my low side gauge didn't move a bit from 0. Also, saturated temp was 2 degrees above temp of high side line. Not sure how to proceed, I disconnected the lines. Should I ignore the no pressure on high end gauge and the temp differences and add a little refrigerant to see how the unit reacts to it? Everything else is working properly, but the air coming out of the registers is not cool. Texas heat is already in the mid nineties, yikes! Thank you!
@vgbr88
@vgbr88 7 жыл бұрын
Your videos are great! Is it okay to keep the leftover refrigerant in the manifold hoses to reduce air contamination the next time you connect the gauges to a unit, or does that put too much stress on the hoses over time; also, is it a good idea to pull a vacuum on the hoses before connecting them to reduce air contamination. Thanks.
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Those ideas are both good but epa 608 does not give any other guidance than that you can't move refrigerant from one system with a certain owner into to another system with a different owner. I would still perform the disconnect procedure but when I work on two or three systems at one house that are the same age and shape then I do just leave the vapor in so I don't have to purge again at that location, thanks
@WayneKellen
@WayneKellen 6 жыл бұрын
My system does not have a TXV in it. It is listed as a "flowrater" system. What is the process for checking this type of R410a system?
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
That is a piston metering device. Look up "acservicetech superheat playlist" feel free to ask questions after if questions are not fully answered, thanks
@MrHefat
@MrHefat 7 жыл бұрын
Thank you for the great video, I am installing a duo split system, to check the subcooling do both inside units have to be switched on ?
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Yes systems with a txv in front of the evap need to be on at both the inside and outdoor units with proper airflow. This process is correct for single speed and two speed compressors. Thanks
@joseorta9928
@joseorta9928 2 жыл бұрын
awsome explanation my question is is the defusion valve used on the blue hose and can it be used on recharging R22 and R410a???
@santhoshr2611
@santhoshr2611 7 жыл бұрын
I'm using in single gauge please explain r410 gas charging
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
You really want to see what is happening on both sides of the system even though you are checking the charge on the high side if you have a txv. Check out this reading the refrigerant gauge playlist. - kzbin.info/aero/PLxnHR5_D2ojxZI3-xx03Bttxe3xCqUD87
@acestu
@acestu 5 жыл бұрын
Hi Ac, I am getting ready to connect to my first unit since leaving college, I have a Testo 570 gauge set and I have just got one of the imperial vaporisers that you recommend, can I connect one of the probes to the liquid line to get an automatic Sub cooling measurement ? , I suspect something is wrong with this walk in freezer as the suction line valve outside keeps icing up badly, there is ice on the evaporator coil inside and lot of fins bashed in, fans seem to be working, whoever fitted the units though has put no fall on the drain pipes and outside the outlet is bone dry, any advice would be gratefully received
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Depending on the temp the freezer is supposed to run at, it may have or need a defrost function. This can be electrical or part of the refrigeration circuit in the form of a hot gas bypass. You don't want to check a charge while the system is frozen. Is there too much product to move to defrost the freezer? I don't have many videos on refrigeration but mainly air conditioners, heat pumps, gas furnaces.
@jiangbian76
@jiangbian76 8 жыл бұрын
Great video! I am learning HVAC by myself and I find your videos very helpful. questions: Is the compressor running when you try to charge the liquid Freon to the suction line? I guess it has to be, but just can't hear any noise in video. How much Freon you gonna lose if you don't charge the liquid back to the unit? When you purge the yellow hose, how do you know the air is completely out? Thank you!
@acservicetechchannel
@acservicetechchannel 8 жыл бұрын
The compressor is running but my mic cancels out the background noise. The best way to disconnect is to anticipate and charge the remainder of the liquid into the system but to make sure you are not overcharging. I would think that the hoses would have a 3 or 4 ounces maybe due to liquid in both the yellow and red hose. You could also work with 3' hoses instead of 5' hoses. The air makes one noise and is clear and the refrigerant makes a different noise and changes to vapor so you can tell. As soon as you see and hear the change you stop venting the air. Thanks for the questions!
@scottiepippeen7001
@scottiepippeen7001 7 жыл бұрын
acservicetech
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Check out other videos on the HVACR topics of interest at- kzbin.info/door/OZR-1IqsAer9wzlvFgb4mAplaylists?view_as=public
@myhealthtoo
@myhealthtoo 7 жыл бұрын
how long can I leave outdoor ac compressor on w/o turning it off
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
A comfort cooling unit can run continually with no problems as long the indoor temp does not go below 68 degrees and you have the proper airflow across the coil, thanks. It shouldn't though because that would mean that the unit was not sized large enough to be able to remove the heat load, thanks
@MrRene1968
@MrRene1968 2 жыл бұрын
alright.
@davejohnsonnola2758
@davejohnsonnola2758 7 жыл бұрын
so the "quik charge" connector acts as a restriction device changing the high pressure liquid back to vapor as you are returning it to the suction side?
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Yes imperial kwik charge 535 is the best type I have used. It turns the liquid mainly into vapor and works well. Thanks David Johnson!
@flamil1
@flamil1 6 жыл бұрын
We are going to charge a system at work that holds about 16 pounds of 410a tomorrow & I told my boss to get us a vaporizer for the gauges so we can charge the way we were taught. He went to get it and apparently they told him at the supply house that no one uses those and they don’t stock them but they could order it if he wants to waste money. They told him it’s ok to charge without it, is that correct or would we damage compressor charging liquid with no meter in line?
@jamessalvia4839
@jamessalvia4839 6 жыл бұрын
I always use a restrictor to flash the liquid to gas. Why risk hurting the compressor? You need to get a new supply house.
@duanechildress1043
@duanechildress1043 6 жыл бұрын
you didnt show how and where to hook up the freon container?
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Hey Duane, have you seen this one of adding refrigerant? Thanks- kzbin.info/www/bejne/hYTTl3WOndBjpLM&index=33&list=PLxnHR5_D2ojxTcAtR_53GoY8huBcSOt0a
@sirvaant
@sirvaant 6 жыл бұрын
What is the reason for taking off the valve caps?
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
The valve caps for the ports or the valve caps for the stem? Ports allow pressure to the gauge set and the stem valves on three position valves allow front seat, mid seat and back seat. In the case of this system, it just has a two position valve with schrader valves in the ports, thanks
@sirvaant
@sirvaant 6 жыл бұрын
Yeah not the caps for the Schrader valve but the the top caps that you took off for the service valves
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
We usually only take the caps on the top off for initial breaking the vacuum unless they are on a system that has 3 position stem valves. I may have just got done a pump down or breaking the vacuum and didn't put them back on yet, thanks
@sirvaant
@sirvaant 6 жыл бұрын
Can you accidently break the vacuum by taking those top caps off the sevice valves?
@David-pj2ro
@David-pj2ro 6 жыл бұрын
when using your gauges with different different refrigerants do you change your hoses?
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
I use different manifolds. I have quite a few. It really depends more on the oil than the refrigerant, thanks!
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
If you want to support the ACSERVICETECH Channel and receive more HVAC Content, Correspond, or Collaborate on your endeavors- check out www.Patreon.com/acservicetech All of the ACSERVICETECH Playlists- kzbin.info/door/OZR-1IqsAer9wzlvFgb4mAplaylists?view_as=public Submit your email to the ACSERVICETECH email updates list at info@acservicetech.com
@stevehayton746
@stevehayton746 6 жыл бұрын
I noticed when you first connected your guages to the system, that you did not purge the air from the lines. Is this normal to do this? Also the connection where you connect the red hose, is this true head pressure or is this liquid line pressure?
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
That was just liquid pressure though some call it head pressure. Some purge the air before putting the liquid back into the vapor side and some purge the air right away. It won't mess up the readings either way, thanks
@felipesolanet7469
@felipesolanet7469 Жыл бұрын
So you didn't actually add any refrigerant, did you?
@kasanganelson7662
@kasanganelson7662 7 жыл бұрын
pls help me with a link to the following , 3R's , how to read gauges and how to charge cos im interested in this trade.
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
3Rs- kzbin.info/www/bejne/m3ykeIuboJJ-nq8&list=PLxnHR5_D2ojxfgT_HPLImCXkJdhMnUtFo&index=1 -- reading gauges -- kzbin.info/aero/PLxnHR5_D2ojxZI3-xx03Bttxe3xCqUD87 --- check out the channel page for other playlists- kzbin.info/door/OZR-1IqsAer9wzlvFgb4mAplaylists?view_as=public
@tonyhamilton1503
@tonyhamilton1503 5 жыл бұрын
Is unit running at this point
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Yes it was. My old mic canceled out the background noise, thanks!
@rocker8692
@rocker8692 7 жыл бұрын
You don't like using an electronic leak detector?
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
I have two but there is no magic end all tool for leak detection. It always ends up being a mix of many, thanks Chad!
@rocker8692
@rocker8692 7 жыл бұрын
Thank you
@charlieb8417
@charlieb8417 5 жыл бұрын
if suspected low refrigerant should you check with bubble Leak Detector even before removing caps? and then again after removing caps before attaching gauges? isn't the schrader valve the most prevalent cause of slow to very slow refrigerant leaking?? Should you replace your older valve caps with newer o-ring caps?
@jacobkelley519
@jacobkelley519 4 жыл бұрын
allright!
@kaosluv8676
@kaosluv8676 6 жыл бұрын
why cant air from the manifold gauge be let into the system? what effects does it have on the system?
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
It increases pressures and disrupts the saturated state of the refrigerant from transferring as much heat, thanks
@redpost2380
@redpost2380 2 жыл бұрын
Somewhat disappointed that you forgot to purge the lines. It is a habit you must never overlook
@rohailsiddiqui730
@rohailsiddiqui730 6 жыл бұрын
Hi. I got HVAC certificat recently. I have to move an Air conditioner from one place to another. Please shoe video procedure from removal to reinstall AC by adding freon.. Thanks . R-Siddiqui
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks for letting me know what you would like to see Rohail!
@rohailsiddiqui730
@rohailsiddiqui730 6 жыл бұрын
Thanks for reply. I have difficulty only that how much pressure of R-22, R410A required to refill the unit for proper work.( how to calculate working pressure).
@100dhanesh
@100dhanesh 6 жыл бұрын
can i get job in hvac
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Take some night time courses, keep showing up with your resume to different companies and don't give up- kzbin.info/www/bejne/iGi4kH6orpZ2eKM
@DarreyonZone
@DarreyonZone 7 жыл бұрын
What is that cylinder on you blue hose?
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
That is an imperial quick charge cylinder for phase changing liquid into vapor before the compressor. I have used several types and this one really seems to work well imperial 535-c "kwik" charge cylinder
@100dhanesh
@100dhanesh 6 жыл бұрын
I want to work with you
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
I appreciate that but now I teach HVACR high school and adults at the local county technical high school and I run the business after school and build the online training. Good Luck in your Efforts!
@thomast2256
@thomast2256 3 жыл бұрын
I love your video. I would like to ask you some questions. I think I miss some thing. In this video, you use 535-C KWIk charge and the air conditioner is OFF, in your next video. kzbin.info/www/bejne/hYTTl3WOndBjpLM I see the air conditioner is ON and you don't need 535-C KWIK to add refrigerant, can you please tell me what is difference between charging refrigerant and adding refrigerant. When we need 535-C KWIK or don't need IT. Thank you.
@cavemanbgood
@cavemanbgood 4 жыл бұрын
Audio was bad. Hard to hear.
@geoa9722
@geoa9722 5 жыл бұрын
So, you pretty much chwrged the system by trnasfering liquid from liquid line to the suction line as a vapor ?? So basically , we moved the refrigirent inside the pipes . Isn"t charging supposed to be ADDING refrigerant from refrigerant tanks ? Or from anothe cilynder ? Like recovery cilynder ? Where are the tanks ?
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Hey George, this one was under the category of charging refrigerant but was just a video on checking the charge and doing the disconnect procedure so that you don't pull refrigerant out of the unit before disconnecting the hoses
@geoa9722
@geoa9722 5 жыл бұрын
@@acservicetechchannelI see now... thank you, man.
@mangalpadda8549
@mangalpadda8549 3 жыл бұрын
You never showed your refrigerant can It is not that good To be a teacher you should show every little step
@ttb6384
@ttb6384 2 жыл бұрын
I ll stick with words of advice this is confusing!!!
@bjklawunder5610
@bjklawunder5610 7 жыл бұрын
slow down man! you know your stuff.....we don't
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Ok thanks for letting me know bj!
Mastering Superheat: The Trick to Charging an HVAC Unit
15:33
Mechanical Pros
Рет қаралды 30 М.
Whoa
01:00
Justin Flom
Рет қаралды 56 МЛН
The FASTEST way to PASS SNACKS! #shorts #mingweirocks
00:36
mingweirocks
Рет қаралды 13 МЛН
Just Give me my Money!
00:18
GL Show Russian
Рет қаралды 1,1 МЛН
Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips!
27:56
AC Service Tech LLC
Рет қаралды 1,5 МЛН
Charging R-22 into an Air Conditioner that is VERY LOW on Refrigerant!
25:13
AC Service Tech LLC
Рет қаралды 256 М.
HVAC 042 A Gauges and hoses on and off the simplest way without contamination.
9:47
Love2HVAC with Ty Branaman
Рет қаралды 57 М.
Adding R410A Refrigerant To AC (subcool method w/TXV)
10:10
Jersey Mike HVAC
Рет қаралды 15 М.
Charging a system with liquid-HVAC Online Training and Courses
6:38
Aircon Academy
Рет қаралды 101 М.
Explaining Superheat and Subcooling to Your Apprentice!
14:14
AC Service Tech LLC
Рет қаралды 612 М.
How I Add Refrigerant to an Air Conditioner
10:20
Fox Family Heating and Air Conditioning
Рет қаралды 382 М.
Steps to Vacuum and Charge Refrigerant on a Mini Split Unit!
15:08
AC Service Tech LLC
Рет қаралды 1,2 МЛН
Goodman Heat Pump Low On Refrigerant!  Adding Leak Stop And Charging With R-410a!
12:43
Whoa
01:00
Justin Flom
Рет қаралды 56 МЛН