Chinese diesel heater error codes E-01 E-08 E--10 etc

  Рет қаралды 51,520

Off grid with Kaos and Lenny

Off grid with Kaos and Lenny

Күн бұрын

Пікірлер: 129
@IAm1InTheIAm
@IAm1InTheIAm 3 жыл бұрын
How wonderful, glad I stumbled across your channel. Very informative, and you're certainly a precious old soul. Thank you. I put one in my '58 VW bus and I love it, just what I need in Alaska. First time I ran it, it threw a EE05 code, which was an overheated unit. Apparently, the fan was not moving enough air through the heater on the LOW setting, and hence, the heat buildup. On the higher settings, it moves more air and is not a problem . Somehow, it's possible to control the fan speed, but given the absolutely atrocious directions, I am petrified to attempt changing any of the settings in case I screw it up. Jolly good show, old chap. Keep a stiff upper lip, and all that rot👍😉
@PKandL
@PKandL 3 жыл бұрын
E-05 I shall add that to the next vid. Thank you
@shawnwhite872
@shawnwhite872 3 жыл бұрын
I live off grid. Tiny house on wheels. Secondary heat I use a chinese diesel heater. Error codes are very difficult to understand. Thank you for explaining so we'll. And yes I love them.
@rickheaney-kickstartthinki2297
@rickheaney-kickstartthinki2297 3 жыл бұрын
Great information mate. Thank you. I've just installed my heater but it wouldn't start. E08 error. Have checked the fuel supply to the pump - all good. Nothing from the pump. Put 12v directly to the pump and nothing. Talking with the eBay seller at present about a new pump. Your video is really helpful Much appreciated.
@lisakinder1287
@lisakinder1287 7 ай бұрын
I used your advice when first getting error 08 several times...thank you 🙏 but then that didn't work another time so I replaced the fuel line from the green one that comes with the kit to a white one, unsure of material but it's less flexy so fuel pumps through better. Can buy online cheap. Never had error 08 since
@PKandL
@PKandL 7 ай бұрын
Thank you for the feed back. It’s such an imprecise science diesel heaters. I’ve mention on several videos about poor quality fuel lines. They split easily and even the tiniest of holes will cause a fuel blockage. Thanks again Pk
@ShaggyEells
@ShaggyEells 3 жыл бұрын
Great vid thank you! Diagnosing the problems in these heaters can be hard =\. I've got an E-10 I'm battling with
@exbassguide
@exbassguide 2 жыл бұрын
Try running at HIGH temps from time to time to burn off carbon deposits!
@leeedwards9043
@leeedwards9043 2 жыл бұрын
brilliant mate😎👍very informative. having a bit of trouble with mine over the weekend so your information is a very good starting point many thanks.
@jetpropelled9024
@jetpropelled9024 Жыл бұрын
Why did you skip over E02? I understand it’s an over-voltage error. Given that nothing has changed in my electrics and it’s been working fine for months, I was really orally bewildered. I solved it by removing the fuse and putting it back after a wait. It seems fine now, but I’m still surprised you’ve not covered all the fuses, even if it’s just to say what it might be but that it’s not a common one.
@PKandL
@PKandL Жыл бұрын
At the start I contacted the manufacturer for advice. Not all error codes were initially covered. So I have actually done a follow up video covering the three error codes I missed. The other issue is the manufacturer appears not to fully understand the error codes on their own machines. I’m being contacted regularly by people with error codes and new problems/solutions to these said coding issues. There honestly isn’t a definitive answer to each code, there are so many problems it’s staggering. I’ve added fuse pulling onto my cheat sheet for e-02 along with nine other possible issues. Thanks for taking the time to message me.
@xxbambamxx7261
@xxbambamxx7261 2 жыл бұрын
Always have a extra pump and glow plug, filter and fan housing laying around, atleast if you really needs it to work 24/7, then you are secure..
@touho68
@touho68 2 жыл бұрын
thanks for basic english demo :)
@dangeroustoman
@dangeroustoman 3 жыл бұрын
E01 could also be a low battery.
@chuckjohns4698
@chuckjohns4698 3 жыл бұрын
Yep it is
@sammilaidlaw8847
@sammilaidlaw8847 2 жыл бұрын
Ah yes my leisure batteries are empty!!! Cloudy winter time … learning these things , first winter with the solar panels etc
@colindyer6107
@colindyer6107 6 ай бұрын
Don't know weather you can help I start up heater starts normal then fan speeds up full then error 6 and stops have checked fan it's running free
@PKandL
@PKandL 6 ай бұрын
You’ll know if the fan is stuck as you’d hear it scraping. So error 0-6 can also be wiring particularly in new fans. If it is new then I’d suggest you contact the supplier as this may be on the main wiring loom. If it’s an older model then pull out the wiring loom connector from the unit and give the connections a good clean and reseat it. Very important to make sure the loom isn’t twisted or kinked as the wires are of a particularly cheap installation and they are know to break if bent. Let me know how you get on
@papilon1958
@papilon1958 10 ай бұрын
Many Thanks my friend for that video,great help.👍
@PKandL
@PKandL 10 ай бұрын
Glad it helped
@jesserosas5452
@jesserosas5452 3 жыл бұрын
Great video. Thank you. I have e/ten error code. Should I buy a new one. Does this happen by improper shutdown? Do you have my suggestions on my best solution?
@PKandL
@PKandL 3 жыл бұрын
Check the Air intake pipe and filter before you do anything. air starvation will cause an E10 error code. Then I'd suggest getting a heating engineer to take take a look. A simple cleaning of the combustion chamber around the sensor maybe enough but of course its the cost against a new one so it may be simpler to buy new.
@exbassguide
@exbassguide 2 жыл бұрын
@@PKandL Try running your heater at high temps to burn off carbon deposits!
@logannixon7306
@logannixon7306 2 жыл бұрын
Hello, thanks for the video! I have an E10 as well, but my heater is freshly installed. I've primed it and attempted to run it several times, but it just spits cold air while the pump runs. Given that it's never successfully heated up, it shouldn't be carbon deposits, right? I can hear the exhaust puffing, just no heat and the eventual E10. Any ideas? Help us greatly appreciated. 😅
@MattysWorkshop
@MattysWorkshop 3 жыл бұрын
Gday, thanks for the help here mate, certainly helped me a lot, cheers
@carpenterfamily6198
@carpenterfamily6198 2 жыл бұрын
Watched a bunch these videos, none seem to tell how to get past or clear the Error Codes. I had an E-10 and could see tons of air in our fuel lines. But we could not enter manual prime mode. The keystrokes to enter prime only work from the default screen ( where the time is displayed ) ~ Being stuck on E-10 we could not solve the problem by priming. Eventually we unplugged the controller for a few minutes. When reconnected the E-10 gone and we were able to enter prime mode and clear the air from the lines.
@PKandL
@PKandL 2 жыл бұрын
Thanks for the tip
@xxbambamxx7261
@xxbambamxx7261 2 жыл бұрын
The cheap chinese heaters, are just as good as a webasto.. But, you have to know how to run it.. What I've seen, is that the accessories are of bad quality.. But the heater itself are just the same.. And if you run them low over time, they will clogg shut, and you will start to get smoke and error codes all over the place.. For most people it is common sense on how they work and how they should be run to function 100%..
@comfortablynumb8832
@comfortablynumb8832 3 жыл бұрын
Error 01 flashing battery is shorten your live wire to the battery and or replace for a thicker 6mm cable
@PKandL
@PKandL 3 жыл бұрын
That’s an interesting one. Thanks for that. Still comes down to the manufacturers comment. Whatever code you get check the electrics first!
@comfortablynumb8832
@comfortablynumb8832 3 жыл бұрын
@@PKandL 100% worked for me
@richardgrimbleby7853
@richardgrimbleby7853 2 жыл бұрын
Hi wonder if you can help ime getting E 00 my fans running no heat and I carnt turn off without taking the fuse out many thanks
@PKandL
@PKandL 2 жыл бұрын
E-00 is normally a “ no error” code. If the fan runs but doesn’t switch off without popping a fuse it’s sounding like a pc board fault. How old is the unit? It’s not unheard of for relatively new systems being faulty. If it is then you probably need a new board.
@richardgrimbleby7853
@richardgrimbleby7853 2 жыл бұрын
@@PKandL Thanks for that it's under a year old my mates just solved an E 07 code which turned out to be water ingress in the main plug on the 3 wires that go to the control panel he sorted this by doing away with the main plug and hard wiring the cables using water proof connections (he does this type of work for a living) it's worked perfect for 3 weeks and now this I think Ile give him a ring I was just trying to give him a head start many thanks
@PKandL
@PKandL 2 жыл бұрын
@@richardgrimbleby7853 that’s a sensible idea. E-00 as a fault is rather unusual so check the circuit board first as it’ll save you time. Please do let me know how you get on, if ever it comes up again I can pass on your experience
@UQRXD
@UQRXD Жыл бұрын
What instructions mine came with none.
@PKandL
@PKandL Жыл бұрын
Not a great start for you! Even if you do have instructions it ain’t that easy to understand them! Hence me writing to them about error codes and even then it only gives a brief description
@Genghis-Khan121
@Genghis-Khan121 2 ай бұрын
You can have wrong voltage all kinds of reasons when your pump isn’t clicking ie working
@fkbiden6990
@fkbiden6990 6 ай бұрын
My diesel heater has E-01 and my controller keeps flashing all different colors
@Danimaz3211996
@Danimaz3211996 8 ай бұрын
I've had an e 07 error for months that I just can't be bothered to try and sort or get someone to sort as it means ripping everything out of my van as they've put it in a very stupid place basically when I turn the diesel heater on it comes on as normal but after about 10 minutes I get an error 07 code come up then it turns its self off does the run down procedure for a few minutes then when It turns off I just hold the on button and it fires back up and comes back on again comes on fine heats up hot , but again runs for about 10 minutes then E07 and turns off it's annoying because we have to keep turning it back on every 10 minutes , but it's not broken in a way thats stopping it working fully it just does what I've explained , it's annoying and I want to get it sorted but I bet If I take it somewhere it will cost me an arm and a leg to get it sorted I've been putting it off but I'm not sure wether to get it sorted , I'm not really sure what places deal with this kind of stuff apart from specialist camper van companies and they aren't cheap :(
@PKandL
@PKandL 8 ай бұрын
That actually sounds like an e-08 error cade. Does the outer shell get almost too hot to touch? An oddity that it runs, switches off then resets on an e-07
@Danimaz3211996
@Danimaz3211996 8 ай бұрын
@@PKandL yeah deffinately an error 07 code , could send you a video of it happening if you could send videos on here but you can't annoyingly yeah runs for 10 mins the E07 then it does the shut down then couple mins later it legs me turn it on for 10 mins and just keep repeating the process , can't feel the actual heater as it's boxed in
@glumpy10
@glumpy10 3 жыл бұрын
I had an E-6 Error. The fan had moved too far AWAY from the control box which has a sensor to detect the magnets in the back of the fan so it knows how fast it is spinning. I got a socket and tapped the fan in looking at the intake end so it moved towards the control box. Needs to be about 1mm but not touching or rubbing. The fans can slide too close and cause rubbing or too far away and the control box loses signal. Needs to be about 1mm or so from the box. Let me know if it helps anyone. Very simple Fix.
@PKandL
@PKandL 3 жыл бұрын
It shows how loose the error codes are. There are just so many variations to pick up on. Thanks for taking the time to comment
@glumpy10
@glumpy10 3 жыл бұрын
@@PKandL Have to remember we are dealing with Chinese made here. They can't even bring themselves to pay a decent translator for the manuals. Be nice to be able to pay another $50 on their price and get a quality unit. Hope the heads up helps some people.
@jackmason4374
@jackmason4374 2 жыл бұрын
Just fitted one and worked ok for couple of days now it’s just blowing cold and I can’t turn it off 🥱 no error codes any ideas
@PKandL
@PKandL 2 жыл бұрын
Ooh! That’s an odd one. Sounds very much like an internal fault. Tbh it’s best to contact the supplier on this one and ask for a replacement. No error code maybe a deep seated fault. Sorry I can’t be more useful
@jackmason4374
@jackmason4374 2 жыл бұрын
@@PKandL thanks👍
@timwilliams6877
@timwilliams6877 Жыл бұрын
Hi I have the E2 error code batteries are fine not over powered can't work it out
@PKandL
@PKandL Жыл бұрын
E-02 is the most common fault this time of year. It base fault is an over charge but it can be a number of other issues. Firstly if you battery is charged make sure the connections are on correctly particularly the live. The wires that the heater are made from are not great, they are quite underrated and this can cause an issue too. Is it a new heater or an older one that’s been sat during the summer? What batteries are you using? Amp hours? Are the linked? Give me an idea of set up B and I will try y to o help you through it. K
@craigjohnston2314
@craigjohnston2314 2 жыл бұрын
Hi Any advice. It was running good but let battery run dwn also out fual but filled nw nd charged uphave é 01 battery charging 14.2v nd under load 13.6v but still flashing battery she priming but é 01 code checked all connections all good. Were. What to luck for. Thanks in advance
@PKandL
@PKandL 2 жыл бұрын
E-01 is an electrical fault as a rule so first thing check the voltage setting. Go into settings on your controller and look for voltage. These heaters are duel voltage and you could have tripped onto 24v which would explain why your battery is fully charged but you’re still getting the error code. Try that first and let me know how you get on.
@craigjohnston2314
@craigjohnston2314 2 жыл бұрын
@@PKandL on heater screen it's 14.2 V all time unless battery not charging and then goes dwn to 11.6 wen use to start. Other then that I've no idea to c if it's on 24v or 12v all I I knw none of applience work off battery only fridge, everything else is plugged into mains to work checked breaker nd fuse all 100% checked and tighten all connections points
@craigjohnston2314
@craigjohnston2314 2 жыл бұрын
It's was Way wired up sockets etc 24v. 12v only fridge nd usb nd 1 set lights
@PKandL
@PKandL 2 жыл бұрын
It can default to 24v it may very well be your issue. What controller do you have and I’ll try to find the way into the control system
@angelosdovletoglou6911
@angelosdovletoglou6911 2 жыл бұрын
Hello and thank you for all the good info you provided. My diesel heater has been working well for 2 years but few days ago started showing E10. The lithium house battery voltage is 13V and fully charged and the display of the diesel heater shows 13V. So that's good. When I start the diesel heater the fan is starting first and slowly the display of the diesel heater shows the voltage to drop from 13V to 9V and then shows the error E10 and shuts down. The Li ion battery display continues to show 13V during all this time. The heater needs 12V to start so something is happening and does not get the minimum 12V needed from the battery or the heater "believes" does not have 12V. Do you think that either carbon build up in the combustion chamber or water ingress via the air intake pipe can cause voltage drop? Is it possible that the electronic controller inside the diesel heater is not working properly and when I start the heater it malfunctions and "reads" low voltage and then it shuts down showing E10 that’s an error code for a variety of reasons? Any suggestions would be greatly appreciated.
@PKandL
@PKandL 2 жыл бұрын
Hello and thank you for your kind words. If your voltage is dropping on the heater but remains constant on the batteries then it sounds like either a control chip malfunction or more likely a wiring issue caused by the heat. Firstly as you fire up and the voltage begins to drop check the voltage on the batteries to make sure they are stable. If the battery draw is ok then you need to remove the outer case and check the wire terminals. They corrode over time and loosen causing a drop in charge. If this is still causing an issue run the unit without the cover and check for any observable signs of shortage. If still no go then it’s the control chip. Remember to check the terminals at the fusebox too. Let me know how you get on K
@nightskyimages2977
@nightskyimages2977 2 жыл бұрын
Mine won't run now and I need it but I have air in the line and priming won't work the fuel won't go through all the way
@PKandL
@PKandL 2 жыл бұрын
Two things. Check you’ve not got an air lock on your fuel tank. Open the lid then switch on the heater. If that doesn’t cure it then it sounds like the pump is faulty. Do you get an error code? How old is the heater. Regards Kaos
@nightskyimages2977
@nightskyimages2977 2 жыл бұрын
@@PKandL hey mate thanks for the reply 👍 I've taken the lid of did nothing to help it I know the hose that goes onto the pump is leaking fuel tho so not sure if that's why I'm not good with that stuff so I'm just lost lol 😕 the heater is over 6months old been running perfect until I ran it out of fuel was silly of me but that's wen the problem started
@PKandL
@PKandL 2 жыл бұрын
@@nightskyimages2977 Thats likely the issue. any air getting in will affect the pumps operation and cause a flame out. Replace the hose and that should.... cure it. There needs to be a constant fow through to the pump. Good luck
@helenanderson6693
@helenanderson6693 2 жыл бұрын
Brilliant 👏
@romakayak
@romakayak Жыл бұрын
New installation but immediately e-2
@PKandL
@PKandL Жыл бұрын
First check your batteries. Is there enough voltage especially after it’s been running for a few minutes. If you’ve multiple batteries in parallel then try disconnecting one of the other batteries. This is a common first time fault. Let me know how you get on
@romakayak
@romakayak Жыл бұрын
@@PKandL I just tried again with my batteries being charged at 14volts and still E-2. The instructions say voltage must be between 9 and 16 volts
@PKandL
@PKandL Жыл бұрын
@@romakayak I’ve just checked my notes from the manufacturer. E-02 can also mean over charge fault! Take that as you will. Go into settings and make sure you’re on 12v and not 24v. It should automatically change voltage as the unit is dual voltage. I know it sound obvious but you’ve not wired your 12v batteries into 24v configuration? That will also affect it. Somewhere this is an electrical issue rather than mechanical fault
@romakayak
@romakayak Жыл бұрын
@@PKandL I have replaced my thin wires and bought a much better,5mm wire and now it's working.
@PKandL
@PKandL Жыл бұрын
@@romakayak really interesting. It’s something I’ll mark down on my trouble shooting list. May suggest it to the manufacturer. Thanks for letting me know
@eero77
@eero77 3 жыл бұрын
Great info, what about those heaters without a display? Mine shuts down from time to time and starts blinking leds. Seems to work better at higher speeds.
@exbassguide
@exbassguide 2 жыл бұрын
Try running your heater at high temps once in a while to burn off deposits of carbon!
@leebroom562
@leebroom562 Жыл бұрын
Cheers 🍺 nice video...
@NLopezzz
@NLopezzz 2 жыл бұрын
Very helpful video on the 08 error I had. Do you have issues with smell/fumes? I have used my heater twice but get a very strong smell inside my tent. It smells like chemicals/ fumes -not exhaust. My carbon monoxide detector shows no exhaust in the tent but the smell is strong and gives me a headache so I stopped using the heater.
@PKandL
@PKandL 2 жыл бұрын
I’m guessing the exhaust is well away from the tent.? As there are minimums set in law over vents in houses so the same rule although not mandatory should really apply to other applications. Sounds odd but have you “sniffed” the hot air vents just in case you have a leak in the heat exchange? How exactly have you set it up. I’m pleased the video was initially helpful K
@MrPsh-xs7ul
@MrPsh-xs7ul 2 жыл бұрын
@@PKandL I just got a error code 8 and it started shutting down and heavy smell of diesel. I was told it was a fuel issue it could of sucked a air bubble and also the caps on the tanks dont vent well. I got it to fire right back up but still have a a smell of diesel coming out of the vents. I’m running it on high hopefully will clean it out or something. It’s blowing really hot still but the diesel smell is there. Have the exhaust out of the wall and the air cleaner out the wall. Will this smell burn off and go away?
@PKandL
@PKandL 2 жыл бұрын
@@MrPsh-xs7ul smell of diesel can be a number of things. Fuel line leak. If you’re using the original green or blue fuel lines they’re not fuel rated and do perish relatively quickly so check the line for a fuel leak. If the smell is coming from the hot air vent there’s an issue with fuel escaping from the combustion chamber. This is more serious because fuel should not enter the heat exchanger. If it does it’s really an issue for a qualified engineer. Third and sometimes the most common issue is you have a leak on the exhaust at the bottom of the unit. As it gets hot the pipe can expand and this causes it to leak particularly under pressure. Use a fire proof sealant around the joints. Try burning it on hot and see what happens but I’m hoping it’s likely to be the first problem I’ve suggested. Do let me know how you get on. K
@darioking3133
@darioking3133 8 ай бұрын
And what happens when E-18 is displayed????
@PKandL
@PKandL 8 ай бұрын
What make of heater are you using? That will make a difference
@darioking3133
@darioking3133 8 ай бұрын
China Car Air diesel 5 kw
@paulring7152
@paulring7152 Жыл бұрын
Hi installed heater primed it worked fine this morning all I'm getting is e10 driving me mad Heater goes to start pump kicks in but does not ignite no bars showing up Heater in new and only just installed it
@PKandL
@PKandL Жыл бұрын
First thing is check the voltage is high enough. Chinese heaters are renowned for electrical issues. If you’re using the fuel tank provided make sure the air hole in the top of the lid is clear. If this blocks it causes a vacuum and fuel starvation, the heater won’t kick in. Still stuck give me some more info and I’ll check the manufacturers list. K
@paulring7152
@paulring7152 Жыл бұрын
@@PKandL Its straight into main tank it worked fine when I first started it up I've also noticed after a while it turns off then goes into like a after burn roaring away then shuts down but then it shows 3 heat bars Then shows code e-10
@PKandL
@PKandL Жыл бұрын
@@paulring7152 ok. The speeding up of the motor shortly before shutdown is programmed into the system. After the combustion chamber shut down the fan is blowing through the system to clear out excessive materials in the chamber, it’s quite normal. You say the fuel is straight from the tank? It still must breathe. There must not be an airlock. Try taking the lid off and fitting it loosely back on. It is sounding like a fuel issue to me. Check through the fuel line to make sure it’s not pinched and there are no air bubbles through. Do let me know how your getting on Pk
@paulring7152
@paulring7152 Жыл бұрын
@@PKandL Hi after investigation it seems the pump is pulling in air cant see no bubbles from tank to pump but from pump to heater I get a fair few bubbles and I keep trying but keeps on producing bubbles in fuel line
@PKandL
@PKandL Жыл бұрын
@@paulring7152 Well, thats a new one to go onto my list of suspects. I'm guessing youve checked the fuel lines onto the pump itself? no splits? The supplied pipe is not the best in the world, but please do keep me informed then I can help others as it may come up again.
@jimmance8899
@jimmance8899 Жыл бұрын
I have some earned knowledge on E-2 code..your battery is low. Enjoy your day 🙂
@PKandL
@PKandL Жыл бұрын
Indeed you are correct, but it can also be a bad earth, over voltage, and insufficient draw due to cable length. Trouble with Chinese DH are that an error can mean several different things. Thanks for taking time to message
@sukhjinder138
@sukhjinder138 2 жыл бұрын
hello i have vevor diesel heater it shows E-3 and when i turn it on it runs for 3-4 seconds and then shows this E-3 on screen and stop working… what should i do
@PKandL
@PKandL 2 жыл бұрын
Hello. You’ve a glow plug fault. It could be a simple thing like a loose or poor connection to the plug or it sounds very much like a coking issue. That means the plug tip is covered in carbon and is not able to produce enough heat to ignite the fuel. You’ll need to open up the casing , locate the glow plug and remove it. Chances are you can just clean it of and that should do the trick. Just be aware the wiring in these units are not the best so make sure you have a good connection. Regards. Kaos
@TerriLynch
@TerriLynch Жыл бұрын
Mine doesn't look like that
@hakansundstrombmwsweden7645
@hakansundstrombmwsweden7645 2 жыл бұрын
Can 08 also mean " no fuel, out of fuel " ?
@PKandL
@PKandL 2 жыл бұрын
Yes. No fuel through the pump into the combustion chamber. It will need to be primed. So filling the fuel tank will not solve the issue. This will lead to an airlock in the fuel lines. Hope that helps
@rexdavis526
@rexdavis526 3 жыл бұрын
I have error 04 ,Can you explain a error 04 please, Cheers
@PKandL
@PKandL 3 жыл бұрын
Hi. I have made a catch-up video on the missing E numbers including E-04. I had to write to the manufacturer to get a clarification. Basically it’s an oil pump issue. They recommend checking the wiring first then the pump. Take a look at the video, I won’t tell you how to fix it but it will give you an idea of the likely problem. Hope that helps K
@graemestephens1894
@graemestephens1894 3 жыл бұрын
AT what voltage does the unit cut out?
@PKandL
@PKandL 3 жыл бұрын
I don’t know the answer to that. There’s nothing in the manual. I’ll try contacting the manufacturer and I’ll get back to you.
@graemestephens1894
@graemestephens1894 3 жыл бұрын
@@PKandL Mine turns off at 11.7 volts , does that sound right? Cheers Mate
@PKandL
@PKandL 3 жыл бұрын
I’ll check but that does sound low
@PKandL
@PKandL 3 жыл бұрын
Ok. The official line is cut out can occur around 11.5v as voltage is too low to feed the pump. Make what you will of that comment so your voltage maybe just on the limit and the motor trips out. Hope that helps
@graemestephens1894
@graemestephens1894 3 жыл бұрын
@@PKandL Cheers mate. that makes sense now.
@peeinginthewind
@peeinginthewind Жыл бұрын
Have a new 5k unit with about 2 hours on it … pump stopped ticking .. replaced it with a new pump same problem E-08 ?
@PKandL
@PKandL Жыл бұрын
So sorry for the slow reply. It sounds like a wiring fault between the unit and the sender in the heater chamber. Wiring is a common fault. It’s rarely the pump. Have you managed to resolve the problem. ?
@peeinginthewind
@peeinginthewind Жыл бұрын
@@PKandL no problem at all.. I wasn't able to get it started .. if I set it to prime fuel the pump turns on... but on normal start operation the pump won't start .. I put my multi meter in the big plug and it seemed to sending a pulse out of the plug 🔌 still no start ..
@carlosalbertoluna5889
@carlosalbertoluna5889 2 жыл бұрын
DESDE ARGENTINA, AGRADEZCO VUESTRA INFORMACION. FUE MUY UTIL.
@PKandL
@PKandL 2 жыл бұрын
Gracias, me alegro de haber ayudado
@colleenhipkiss4923
@colleenhipkiss4923 3 жыл бұрын
Don’t get error 4 no one seems to know what the hell that one is
@PKandL
@PKandL 3 жыл бұрын
I need to do an addendum to my vid. E04 can be either low voltage or a disconnected fuel pump. Check to wiring to the pump first then fuel line in. Hope that helps
@kr3392
@kr3392 2 жыл бұрын
Great video 👍 But i have Errorcode 17 does anyone know what that mean
@PKandL
@PKandL 2 жыл бұрын
Blimey. Never heard of a 17 Think your lcd controller maybe up the shoot. I may contact the manufacturer and ask. Because I’m not sure it even goes that high.
@PKandL
@PKandL 2 жыл бұрын
Just looked it up. E17 is a fuel pump error normally associated with the wiring. Maybe shorting out or pump over heat is also possible. It’s a new one on me. Hope it helps
@kr3392
@kr3392 2 жыл бұрын
@@PKandL thank you 👍 for quick answer im not in THE garage right now, but i Will be there tomorrow. Thanks again, i Will be back
@kr3392
@kr3392 2 жыл бұрын
@@PKandL Now its working i just i just reinstalled THE red positive om THE battery 👍
@PKandL
@PKandL 2 жыл бұрын
@@kr3392 that’s a relief. I shall make a note. If it ever comes up again. Thanks for letting me know
@Roger_Gustafsson
@Roger_Gustafsson Жыл бұрын
They work absolutely not fine. Lol. Total Garbage
@PKandL
@PKandL Жыл бұрын
Sadly a high percentage are poorly made. If you get a good one they’re ok. I’ve hade mine 2 years and it’s still chuntering. Maybe I’ve been lucky 🍀
@Roger_Gustafsson
@Roger_Gustafsson Жыл бұрын
@@PKandL Yeah, mine worked for about 20 minutes. Then fuel pump error. Got a new one. Glow plug error. Got a new one. Now high voltage. Threw it in the bin.
@PKandL
@PKandL Жыл бұрын
@@Roger_Gustafsson blimey. Talk about bad luck. I get your feeling about tbh I think I’d have done the same or demanded my money back
Chinese Diesel Heater Error Codes E01 - E10  All Codes, Faults & Fixes
8:41
Van Life Uk A Complete Survivors Guide
Рет қаралды 260 М.
204. E-08 Error - Chinese Diesel Heater
16:43
Ralph's House
Рет қаралды 9 М.
ROLLING DOWN
00:20
Natan por Aí
Рет қаралды 11 МЛН
Glow Stick Secret Pt.4 😱 #shorts
00:35
Mr DegrEE
Рет қаралды 11 МЛН
Just Give me my Money!
00:18
GL Show Russian
Рет қаралды 643 М.
This Dumbbell Is Impossible To Lift!
01:00
Stokes Twins
Рет қаралды 37 МЛН
Chinese Diesel Heater Error 0-8 Fixed!
14:29
VanOnTour
Рет қаралды 77 М.
espar heater vrs Chinese parking heater side by side comparison
12:08
E-01 error Solved! Chinese diesel heater issues.
16:10
Chinese diesel heater error E-08 PART 1 #chinese #heatercentral
14:15
Steve the Transit Camper
Рет қаралды 17 М.
Chinese Diesel Heater New Controller Q & As
14:47
Mic S
Рет қаралды 111 М.
How to tune a Chinese diesel heater with no tools 2kW & 5kW
10:20
Chinese Diesel Heater Error Codes Troubleshooting Guide
12:49
chinese diesel heater insight
Рет қаралды 7 М.
ROLLING DOWN
00:20
Natan por Aí
Рет қаралды 11 МЛН