Compressor Replacement! Using Triple Vacuum Evacuation!

  Рет қаралды 5,245

Jeff’s HVAC Adventures

Jeff’s HVAC Adventures

Жыл бұрын

In this video we remove a compressor that Burnt Out and blew a pin. Install a new compressor, and pull a triple Vacuum!
Like and Subscribe
email me
jeffshvacadventures@gmail.com

Пікірлер: 52
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
So the more I thought about this one the more I’m thinking there is an issue with the TXV staying open too far. Usually a non adjustable TXV has a Minimum Superheat setting which keeps the superheat positive. I am getting a 0 superheat. Even after I put the bulb in 32° water, I only got about 8° of super heat. The TXV should have closed a lot more than that in freezing water. I am following up in a couple weeks to replace the filter drier (standard practice after a burnout) and I will bring a TXV with me when I go back. Jeff
@matth.4932
@matth.4932 3 күн бұрын
Best how to video of unbrazing! You earned my subscribe! Was nice of you to clear the leaves out for home owner.
@JeffsHVACAdventures
@JeffsHVACAdventures 3 күн бұрын
Appreciate that. I did get most of the leaves out of the base pan.
@jrh86
@jrh86 Жыл бұрын
Brilliant job👍👍👍
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Thanks man.
@Aviation2016
@Aviation2016 Жыл бұрын
I subbed. Im in school to become a tech and that was a very good video of a triple evacuation. Im always looking to do things the best I can when I work. Thank you for the video, I saved it to look back on.
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Thanks for watching, and subbing!
@dfwhvac
@dfwhvac Жыл бұрын
Yellow jacket makes a vacuum rated stubby hose . I use it to attach my micron gauge and then close the ball valve on the hose when I’m ready to charge so oil never hits the sensor
@SupremeRuleroftheWorld
@SupremeRuleroftheWorld Жыл бұрын
the TXV is probably borked from the junk that came from the old compressor. it should always be replaced after a violent compressor death. dont forget any check valves and/or the 4 way valve! and ensure its running proper in both modes. its really sucks if you have to replace those...
@jenniferm5375
@jenniferm5375 Жыл бұрын
Jeff, a couple of weeks ago we had the exact same problem compressor making weird noises at starting, well same thing low super heat and sub cooling wouldn't rise, replaced txv and compressor and what a difference, su cooling went up and super heat is at where it should be
@97Napkins
@97Napkins Жыл бұрын
close suction isolation valve and no leak from compressor
@oscarguzman9669
@oscarguzman9669 8 ай бұрын
dode it was gray , just miss one think every time you change an compressor change the tsv
@dfwhvac
@dfwhvac Жыл бұрын
And I believe your pinned comment is correct , I bet the txv is most definitely over feeding . That sucks because those type of things there’s really no way to know that until you get the system back up and running . A lot of guys at my company when compressors fail are starting to always add TXVs to the repair quotes just to cover the ass and I’m probably going to start doing the same thing , within reason of course
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Yea it certainly does suck having to go back to the customer with the news but usually they understand in the long run.
@chrissipple1018
@chrissipple1018 Жыл бұрын
That little of missing insulation will not hurt anything, it just looks a lot cleaner.
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Yup. I didn’t have any to put back anyway. 😂🤙
@samersarah957
@samersarah957 Күн бұрын
Nice job bro what size of tip use for compressor lines and how to set torch I mean how many pressure for acetylene and oxygen? Thank you
@JeffsHVACAdventures
@JeffsHVACAdventures Күн бұрын
I’m not exactly sure what size the tip I use is but I set my pressures at 7 acetylene and 14 oxygen. Some guys due 10-20 but I’m good at 7-14.
@jonhvac
@jonhvac Жыл бұрын
I'd change the TXV
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Yea I am. I pinned a comment about it.
@alross18058
@alross18058 Жыл бұрын
I used to always put in a suction filter after a burnout
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
I considered that but where the acid test came negative I decided against it.
@VinceCuzmono
@VinceCuzmono Жыл бұрын
Outstanding!!! Love the bulb test. Does no super heat mean you have liquid going back to compressor? Yeah something is up, maybe that 5/16 is kinked somewhere or the meter device on the outdoor unit is gunked up. 🤔
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Yea no super heat means liquid is coming back. I’m going to follow up in a couple weeks to change the filter drier anyway. (Usually always do that after a burnout.) And I might pull the outdoor piston and clean and also maybe check that indoor TXV again. It was working but i have a suspicion it might not be working properly.
@frankduarte7109
@frankduarte7109 15 күн бұрын
When you go back to change the txv and drier will you use the same refrigerant? Or do you have to go back in with virgin after a burnout
@richlikeg3722
@richlikeg3722 Жыл бұрын
What tip did you use on your torch? You were able to heat it up fast. Does breaking vacuum hurt the micron gauge?
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Just a standard tip. No, the micron gauge can handle a little pressure.
@jamestoy426
@jamestoy426 Жыл бұрын
What did take out the compressor? I think I would go back and change the liquid line out because there was not enough discharge. to get rid of the heat and I think the compressor overheated. I also agree with Jon Hvac I would also change the TXv would not be a bad idea
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
The stuck TXV took the compressor out.
@joselanda8316
@joselanda8316 Жыл бұрын
That txv over feeding is probably what killed the compressor in the first place...
@xelaju8
@xelaju8 Жыл бұрын
What kind of brazing rod did you use for the compressor? silfos15?
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Harris Stay-Silv 15. 15% silver 80% copper 5% phosphorus
@dipley3771
@dipley3771 Жыл бұрын
Maybe airflow, also don’t see how adding that extra refrigerant would cause it to start flooding back again. Did you let it run 15 minutes after that?
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
It was a bad TXV.
@sheldon8115
@sheldon8115 Жыл бұрын
I don’t think it’s the size of the discharge line because your head pressure was normal. I think Txv
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Yea. I pinned a comment about it.
@stevebates6281
@stevebates6281 Жыл бұрын
Hi. I need to replace a Mitsubishi compressor. Will map pro gas get hot enough to separate the lines from the compressor? Are you using oxy acetylene?
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
I don’t think Map gas will get it hot enough. And if it does it will take a really long time. Your gonna need Oxy acetylene (recommended) or turbo torch.
@Kilcrops0914
@Kilcrops0914 Жыл бұрын
At least now you know what killed that compressor
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Sure do!
@glennsepelak5113
@glennsepelak5113 Жыл бұрын
Copeland wants stubs on compressor, Do Not beat it shut.
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Didn’t know that. Been beating them shut for 20 years. Thanks for the advice.
@lunytoo
@lunytoo 11 ай бұрын
Hi Jeff I’m curious you could have quoted a new condenser right?
@JeffsHVACAdventures
@JeffsHVACAdventures 11 ай бұрын
This one is going back a ways but I’m thinking this compressor was under warranty.
@applianceman6009
@applianceman6009 Жыл бұрын
Glad that’s a Copeland. I am not a fan of LG.
@timrob0420
@timrob0420 Жыл бұрын
Don’t those tests say must be running compressor and take sample of vapor refrigerant??
@JeffsHVACAdventures
@JeffsHVACAdventures Жыл бұрын
Ideally yes. But where this compressor was bad and blew a pin, I had no choice.
@bigdaddy4975
@bigdaddy4975 Жыл бұрын
Running no superheat is really bad for the compressor no wonder it burned up.
@osvaldomcs1213
@osvaldomcs1213 5 күн бұрын
Never charge on the low side. Liquid in the compressor.
@JeffsHVACAdventures
@JeffsHVACAdventures 5 күн бұрын
That's the only way you can charge when topping a system off. A heat pump has a suction accumulater which protects the compressor. I agree you don't want to slug a compressor with liquid while it's running but charging with liquid slowly through your suction side is the only option most times on AC systems.
@osvaldomcs1213
@osvaldomcs1213 5 күн бұрын
You just killed the new compressor
@JeffsHVACAdventures
@JeffsHVACAdventures 5 күн бұрын
No.
HVAC 150 Vacuum p17 Example 5 Triple Evacuation
14:48
Love2HVAC with Ty Branaman
Рет қаралды 17 М.
Burnout Compressor change (R410a) with acid cleanup
13:42
NathansHVAC
Рет қаралды 145 М.
تجربة أغرب توصيلة شحن ضد القطع تماما
00:56
صدام العزي
Рет қаралды 57 МЛН
KINDNESS ALWAYS COME BACK
00:59
dednahype
Рет қаралды 163 МЛН
마시멜로우로 체감되는 요즘 물가
00:20
진영민yeongmin
Рет қаралды 31 МЛН
Clowns abuse children#Short #Officer Rabbit #angel
00:51
兔子警官
Рет қаралды 73 МЛН
How to vacuum an air conditioning system.
20:32
paulohvac
Рет қаралды 39 М.
Locked Compressors
20:13
HVAC School
Рет қаралды 108 М.
HVAC Advanced: Triple Evacuation
6:54
Chadwell Supply
Рет қаралды 10 М.
Diagnosing a Locked Compressor 3D
10:02
HVAC School
Рет қаралды 48 М.
How to Replace a Defective Copeland Compressor in a Rheem 4 ton Outdoor Central AC Condenser
27:29
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 25 М.
Testing if an HVACR Compressor is Shorted to Ground, Open, or Overload Tripped!
11:06
Compressor Burnout and Acid Management: HVAC 101 @MechanicalPros
14:26
Steps to Vacuum and Charge Refrigerant on a Mini Split Unit!
15:08
AC Service Tech LLC
Рет қаралды 1,2 МЛН
Severely Oil Logged TXV Takes OUT Compressor!
17:41
Jeff’s HVAC Adventures
Рет қаралды 2,8 М.
تجربة أغرب توصيلة شحن ضد القطع تماما
00:56
صدام العزي
Рет қаралды 57 МЛН