This is really good. I am in Analog design but continuosly watch your videos for knowledge and better understanding.
@analoglayout3 жыл бұрын
Welcome
@Free_Agent_0075 жыл бұрын
I am a daily costumer to your channel good work brother keep it up
@anwarbadhusha26524 ай бұрын
sir kindly post a video for signal integrity sir your videos are very awesome to understand
@kanthineelamsetty26034 жыл бұрын
Superb CLS and it is very useful thank u
@analoglayout4 жыл бұрын
Welcome 😊
@venkateshmarri72716 жыл бұрын
Nice explained sir Keep...It up.
@thejaswinibatthina21554 жыл бұрын
The way of explanation is awesome,one small doubt sir is there we have different types of cross talks or the types are related regarding metal to metal and metal to subtrate as you explained in video.types of crosstalk is related to this or any else are there?
@analoglayout4 жыл бұрын
I'm not able to understand your question
@thejaswinibatthina21554 жыл бұрын
Can you please explain types of crosstalk
@tomurkin55632 жыл бұрын
Thank you for the video. A few questions: 1. Assuming an all-digital IC, there are two obvious power nets: VDD and GND. You suggest the shielding network to be connected to another ground net called VSS. Is the VSS connected to GND somewhere on the IC or outside the chip? 2. Can shielding be also done with nets connected to the supply network, VDD? 3. Are all clock networks in ICs routed with shielding? Thanks!
@gopal.thadikamalla72983 жыл бұрын
Hi, Why Generally shielding lines are connected to VSS not to VDD ?
@ramakoteswararaopayyavula86776 жыл бұрын
for which nets we have to follow side wall shielding.....i mean names of the nets..
@analoglayout6 жыл бұрын
net is important , we have some criteria based on that we have to do shielding , most of the time side wall shielding they prefer
@ramesh3553 жыл бұрын
@@analoglayout why not other?
@sudheeryarramsetty82156 жыл бұрын
hi sir,, in this video you told that you will tell( 1.05 sec) about critical net and sensitive nets .....but u did not covered that ..so please make a note sir...and thank u once again such a great knowledge sharing
@SaiKumar-qs9dr5 жыл бұрын
Sir I have a small doubt in cross talk prevention for suppose distance r width of the two metal will increase according to formula of the capacitance. While is increasing distance between two metals capacitance increase and also electric field increase then more unwanted siganls also created..?
@analoglayout5 жыл бұрын
Distances increase , cap will decrease
@darshanbnaik5 жыл бұрын
bro the formulae of cap is c = epsilon*A/d
@Sourav_Soumyajit4 жыл бұрын
Nicely elaborated.
@nishtharawat64606 жыл бұрын
one doubt , Should we follow some generalized thing to maintain width and spacing for shield or minimun is fine , as this will also put some cap over the signal ?
@analoglayout6 жыл бұрын
ya , we have to keep mim width , how ever its gng to connect to gnd , so no need to worry abt cap , only side wall and fringe cap is main prob , by connecting a gnd , this problem also we can solve
@vijayanathreddy67894 жыл бұрын
In co axial shielding why we use top metal on upper side and low metal in bottom side
@analoglayout4 жыл бұрын
Then , how will u form a co-axial shielding ?
@mohammedafzal5344 жыл бұрын
If you need to protect the net from all sides means you have do it from 4 sides right! So for top & bottom you are using higher & lower metals. For side wall we are same metals
@manishasutar87015 жыл бұрын
For sidewall shielding can we go for higher metal than a signal line?
@analoglayout5 жыл бұрын
No , same metal u have to use
@manishasutar87015 жыл бұрын
@@analoglayoutCan I know the reason behind using the same metal for sidewall? Why not higher or lower metals than the signal line?
@mohammedafzal5344 жыл бұрын
@@manishasutar8701 May be both will fabricate on same step if we use same metal for side wall. If we use higher r lower metal it will act like top & bottom shielding. I too don't know exactly but i thought in this way
@gopal.thadikamalla72983 жыл бұрын
Hi,clk signals and data signal in which signal we need to shielding? why?
@analoglayout3 жыл бұрын
Based on which is critical, or else shield data
@durgaprasadyellapu77416 жыл бұрын
in side wall shielding why should not go for higher metal is there any problem sir in this you were explaining with m1
@analoglayout6 жыл бұрын
what metal ur using for routing , same metal only u have to do shielding ... if m1 ur routing same m1 should be used for shield , if m2 , m2 u have to use
@nikkiscars42223 жыл бұрын
Sometime we do shielding with VCC also ?
@analoglayout3 жыл бұрын
Ys , some time
@RamaKrishna-cb3yd Жыл бұрын
Why should connect shield line connect vss or gnd why should not connect vdd
@nagendrababumoodu25836 жыл бұрын
Sir I want to know what is Critical nets and sensitive nets please make a comment sir
@analoglayout6 жыл бұрын
this details u will get from schematic engg , but basically bias block , clk signal , etc ...
@PavanKumar-ii3gm3 жыл бұрын
Sir if we increase in width that more gap drc errors will come
@akshatpathak253 жыл бұрын
There should be available space to avoid drc
@kondasandeep39285 жыл бұрын
Is metal orientation is solution for cross talk between metals?
@analoglayout5 жыл бұрын
I thg , I've explained everything in this video , watch it Fully
@mohammedafzal5346 жыл бұрын
Good explanation!
@analoglayout6 жыл бұрын
thqqqqqq
@mohammedafzal5346 жыл бұрын
Whether we have a parasitic capacitance between nwell & p-sub
@mohammedafzal5346 жыл бұрын
Can u make a video on parasitic components.
@analoglayout6 жыл бұрын
ya , we have 4 cap , 4 diode , 4 resister , in one mos , gate to body , gate to source , gate to drain , drain to source , nwell to p sub , also
@analoglayout6 жыл бұрын
yap , sure ... soon
@pacchipulusuvenkatesh37696 жыл бұрын
Sir please make a video on chemical mechanical planarization(CMP)
@sandylootera71984 жыл бұрын
sir, thank for video can i get some more documents related to signal integrity or please provide site details for signal integrity .
@prabhutechnologiechannel63243 жыл бұрын
Hi sir Can you explain me virtuoso l and xl difference..
@kiruthika66803 жыл бұрын
How to interconnect two metals?
@analoglayout3 жыл бұрын
Using via
@youthcentral4936 жыл бұрын
bro nice
@kmeenu5 жыл бұрын
Thanks sir!
@dosapatikrishnakumar65696 жыл бұрын
Hi.. bro Your explanation is good.. I have small doubts regarding shielding 1. Why we mostly connected shielding nets to ground? Why not to Vdd? In which cases shielding nets connected to Vdd? 2.what happens when we do half of the shielded net connected to Vdd and half shielding of the net connected to the Gnd.? Both on the same net this is my IBM Client interview qns 3. Generally we avoid shielding to the high frequency signals? If do what happened.. for this qns I think delay of the net increase.. I expect from you.. another any reason? 4. Vref ,Vbais ,Vclk for which net you give high priority to do shielding and why?
@analoglayout6 жыл бұрын
1. based on the signal , we have to connect it to vdd or vss or gnd , but most of the time we will connect to gnd , bcos its a low impedance path compare to vdd,vss 2. how will u do half vdd, half vss ? its a useless methos , bcos any one half only will shield effectively , another half will get disturbance 3. high fq signal carry , high current & Fq , so u should shield high fq net
@dosapatikrishnakumar65696 жыл бұрын
@@analoglayoutok tq bro
@anilvellanki47175 жыл бұрын
High frequency signal is nothing but clock signal,If you shield clock signal you will add more loading to it which will delay the signal,So we should only shield the place where we are seeing the cross talk,In general to avoid any disturbance fist we should plan to route these critical signals(usually in medium metal).so clock signals should not be shielded in general! Vref is ref signal which is very critical in most cases we will do co axial shielding bias signal can be done in sidewall again it depends on designer,some times he does not want any noice on it then go for co axial vclk we will only shield where ever it is required!