Current Transformer Concepts| CT Burden | CT Accuracy Class

  Рет қаралды 54,515

Electrical lectures

Electrical lectures

Күн бұрын

Пікірлер: 42
@amazingvideos673
@amazingvideos673 3 жыл бұрын
Wow first time ct burden is explained in simpler manner
@asmafarid2939
@asmafarid2939 3 жыл бұрын
Too good. Wonderful explaination
@nuthalapatisudhakararao3515
@nuthalapatisudhakararao3515 2 жыл бұрын
Your way of explanation is awesome thank u ...keep more topics ..
@electricallectures
@electricallectures 2 жыл бұрын
Stay tuned and dont forget to subscribe plz
@sohailjanjua123
@sohailjanjua123 3 жыл бұрын
Hi, I like your lecture. Thanks
@electricallectures
@electricallectures 3 жыл бұрын
Stay tuned and dont forget to subscribe plz
@sanjayhake6872
@sanjayhake6872 Жыл бұрын
Nicely explained
@electricallectures
@electricallectures Жыл бұрын
Thanks stay tuned and dont forget to subscribe plz
@hfahFun
@hfahFun 3 жыл бұрын
Stunning well done
@macpeleanyanwu745
@macpeleanyanwu745 2 жыл бұрын
This is an excellent tutorial, keep it up
@electricallectures
@electricallectures 2 жыл бұрын
Thanks. Stay tuned and dont forget to subscribe
@amazingvideos673
@amazingvideos673 3 жыл бұрын
Outstanding way of teaching
@manojillangasooriya3590
@manojillangasooriya3590 11 ай бұрын
good one. thank you.
@electricallectures
@electricallectures 11 ай бұрын
Stay tuned and dont forget to subscribe plz
@wakh6260
@wakh6260 3 жыл бұрын
Perfect as usuall
@yibeltalassefa3619
@yibeltalassefa3619 2 жыл бұрын
Thanks a lot
@electricallectures
@electricallectures 2 жыл бұрын
Stay tuned and dont forget to subscribe
@suryasreedharreddy2277
@suryasreedharreddy2277 3 жыл бұрын
CT operating in normal mode then fault current appears in load ... how can we reduce fault current on primary side by effective changes on Secondary side... what are the changes possible on Secondary side to reduce fault current on primary side
@sushilkoch8625
@sushilkoch8625 Жыл бұрын
Thank you.
@electricallectures
@electricallectures Жыл бұрын
Thanks. Stay tuned and dont forget to subscribe plz
@Ragavenutb
@Ragavenutb 3 жыл бұрын
Hi,if data markings on the CT's disappear how would one determine the correct ratio? Thank You.
@electricallectures
@electricallectures 3 жыл бұрын
Then you have to do it by hit and trial. One thing for sure the output is always 5. So by measuring secondary current and primary you can compute ratio
@Ragavenutb
@Ragavenutb 3 жыл бұрын
@@electricallectures so i basically run 100a through the line and measure Ct output amps. If its 2.5 its primary is 200a. But due to impedance and accuracy class, output can't be accurate right?
@abidkayani336
@abidkayani336 3 жыл бұрын
👍
@edupros9028
@edupros9028 3 жыл бұрын
From which software u make this video
@ahmadmohmed4448
@ahmadmohmed4448 26 күн бұрын
what he means by"CT Secondary should never be opened"? Is it even possible to open it Physically?
@electricallectures
@electricallectures 26 күн бұрын
I mean to say secondary connection should not be open while CT is energizes. And it can also be possible to open CT physically as in Clampmeter
@ahmadmohmed4448
@ahmadmohmed4448 25 күн бұрын
@@electricallectures thanks a million, god bless you
@suryasreedharreddy2277
@suryasreedharreddy2277 3 жыл бұрын
What happens on primary side current when burden increases on Secondary side
@electricallectures
@electricallectures 3 жыл бұрын
No effect on primary but if burden exveed the ratio will be disturbed and so as secondary current
@suryasreedharreddy2277
@suryasreedharreddy2277 3 жыл бұрын
If the Secondary winding is replaced with reactance instead of short circuit after sometime then what happens on primary side current
@debarpanchanda7506
@debarpanchanda7506 3 жыл бұрын
Sir could you please explain any practical application or uses of reduction of CTR...? It's will be much beneficial for me..Thanks in advance sir.. 🙏🙏🙏
@electricallectures
@electricallectures 3 жыл бұрын
Do you want to ask usage of CT . I dont actually understand your question. Reduction of ctr
@Artistic_S0ul_
@Artistic_S0ul_ 3 жыл бұрын
I have a question. Please could you tell me, what would happen if the flow primary current is 300 A permanently, and the ratio CT is only 200/5 A? Thanks by the answer.
@electricallectures
@electricallectures 3 жыл бұрын
Ct will saturate and 5 A will continue to flow
@Artistic_S0ul_
@Artistic_S0ul_ 3 жыл бұрын
@@electricallectures Thanks a lot by the answer.
@fabianm.2982
@fabianm.2982 2 жыл бұрын
@@electricallectures I don't agree, please elaborate further. There are times when you can set the pick to be above the 100% rating, which is 5A. I have seen the CT's rated 600/5A and relay set at 1.2 of the primary current. Is that a wrong practice or what?
@electricallectures
@electricallectures 2 жыл бұрын
Absolutely wrong. Ct can only produce 5A. As far as pickup is concerned , 1.2 can be set if the maximum primary current is 600. Let say ur relay is supposed to trip @400A which is 1.2 times. Now ur ct is 600/5 and it will work in this situation
@Dario-ox6zi
@Dario-ox6zi 3 ай бұрын
I need 1000/5 but 0.3 burden 15va
@سبکچھ-ش4ل
@سبکچھ-ش4ل Жыл бұрын
200/2 farmola 😊
@electricallectures
@electricallectures Жыл бұрын
Don't understand
@michelvidallo7288
@michelvidallo7288 5 ай бұрын
i cannot understand you bus or bar type?? wtf
Difference Between Single Phase and Three Phase Power
9:43
Electrical lectures
Рет қаралды 30 М.
Current Transformer vs Voltage Transformer : What’s the Difference ? TheElectricalGuy
12:32
How To Choose Mac N Cheese Date Night.. 🧀
00:58
Jojo Sim
Рет қаралды 107 МЛН
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 10 МЛН
Муж внезапно вернулся домой @Oscar_elteacher
00:43
История одного вокалиста
Рет қаралды 7 МЛН
5P10 & 5P20 Class of Current Transformer | Explained | TheElectricalGuy
11:17
Gaurav J - TheElectricalGuy
Рет қаралды 26 М.
Current Transformers (CT)
14:31
Eaton
Рет қаралды 508 М.
What are Resistance Reactance Impedance
12:26
Prof MAD
Рет қаралды 1,1 МЛН
Current Transformer types every Electrical Engineer should know | TheElectricalGuy
16:58
Gaurav J - TheElectricalGuy
Рет қаралды 13 М.
Current Transformer Basics | Effects of CT Saturation on Protection Relays
9:11
Romero Engineering Company
Рет қаралды 13 М.
Overcurrent, Overload, Short Circuit, and Ground Fault
6:54
Dave Gordon
Рет қаралды 923 М.
How to read the parameters of PS, 5P & metering core of a CT | TheElectricalGuy
13:47
Gaurav J - TheElectricalGuy
Рет қаралды 9 М.
What does "impedance matching" actually look like? (electricity waves)
17:08
I never understood why you can't go faster than light - until now!
16:40
FloatHeadPhysics
Рет қаралды 4,1 МЛН
How To Choose Mac N Cheese Date Night.. 🧀
00:58
Jojo Sim
Рет қаралды 107 МЛН