DUUUUDE I’m watching u more then Netflix stay BROOWN MY FOREIGN BROTHER
@D2DNYAC Жыл бұрын
Thank you 🙏 😂
@roqueherrera8471 Жыл бұрын
Ima sign up tonight bro definitely very THERAL descriptions on real life incidents…….
@roqueherrera8471 Жыл бұрын
6:15 In beautiful Dixon, CA
@14idontcare14Ай бұрын
You mean, "thorough"?@@roqueherrera8471
@Rinebo Жыл бұрын
I’m about to work my way through all your videos! Thank you for posting these!!!
@marcoselgaucho1106 Жыл бұрын
Cool! Haven’t seen these yet! 🇯🇲 thanks
@D2DNYAC Жыл бұрын
Thanks for watching!
@roqueherrera8471 Жыл бұрын
Mi Hermano I as a foreigner from MX u a bad ass
@D2DNYAC Жыл бұрын
Thank you for stopping by
@dionesiogerman55282 ай бұрын
What if xhange the compressor wirhout coresense protection module..it is possible? And how to wire or bypass the coresense?
@D2DNYAC2 ай бұрын
Just shunt the switch wires m1 & m2
@alejandrozometa1951 Жыл бұрын
Great video are you working on a rack compressor or a chiller
@D2DNYAC Жыл бұрын
Thanks
@jasonjohnsonHVAC4 ай бұрын
Some have a 3 wire thermistor set up. It's uses a PTC & NTC thermistors
@D2DNYAC4 ай бұрын
Thanks for watching
@boywhohadatiger9 ай бұрын
Had a locked rotor code on one of these today but the compressor would start briefly and stay on but it sounded like it was losing its stage or variability
@D2DNYAC9 ай бұрын
Is your compressor electrically sound?
@boywhohadatiger9 ай бұрын
@@D2DNYAC yes it’s receiving high voltage and windings are in tact. It’s a digital compressor and I didn’t know it had that Loading and unloading feature until later. Luckily I didn’t give an official diagnosis until I got more information. I’ll go back later and adjust the set point or disable the valve but I think the compressor is fine after watching your videos. I’m a preferred member I can pm you with more info.
@jiyesh1007 ай бұрын
I have a same copeland scroll compressor and it works and after dont pump but the motor is running. May be i need to decrease the discharge pressure
@D2DNYAC7 ай бұрын
No, my friend, just let it cool down completely by leaving it off, then see what you got!!!
@sureshkumar-ux2nq Жыл бұрын
What are the factors to be seen when replacing a compressor if not getting same manufacture, let me know
@D2DNYAC Жыл бұрын
Capacity, voltage /power supply, oil and you may have to do some additional piping and mounting
@mohamedatef-do6pj Жыл бұрын
I hvav a problem of 4 flashing (scroll compressor high temperature) and compressor current is 120A Could it be because of crankcase heater??
@D2DNYAC Жыл бұрын
120 amps that sounds very high what's the supply voltage and compressor tonnage?
@ДайтеЗрелищ Жыл бұрын
Hello👋. How named your multimeter?
@D2DNYAC Жыл бұрын
I responded with a link to Amazon
@ДайтеЗрелищ Жыл бұрын
@@D2DNYAC model, name, shield. Its wery saved me.
@ДайтеЗрелищ Жыл бұрын
@@D2DNYAC i make very more audit and diagnostic works and simultaneously ampers and Volts its wery comfortable.
@ДайтеЗрелищ Жыл бұрын
🤣Say the model.
@jasonjohnsonHVAC2 ай бұрын
I just did a video on using my laptop to connect to the Coresense
@D2DNYAC2 ай бұрын
Checking it out thanks
@roqueherrera8471 Жыл бұрын
Sup my brotha
@D2DNYAC Жыл бұрын
Yes sir
@ДайтеЗрелищ Жыл бұрын
You Will connect to this device. Bitzer standing analog only 95 series screw.