Did you see that new ignitor was a 400 V model, the old was a 240 V. It should work but with lower V. It was specified higer than the old, but it will be lower anyway. Bu I hope it works fine :-)
@Smachine62 Жыл бұрын
Good video. My cleaner only fires if you lift the diesel head off to give it more air. What could this be? Do you think the electrodes could be set up wrong?
@DavidMcLuckie Жыл бұрын
Does your blower have an adjustable intake vent?
@neiljones450110 ай бұрын
Hi My diesel spark is purple, the ignition bars a loose and the diesel is not misting. Any tips would be great
@TheInfoworks6 жыл бұрын
HI, Was it me or did that motor not sound happy, a bit rumbly, what is the voltage across the capacitor from the coil connection to the other ac in? Cheers
@DavidMcLuckie6 жыл бұрын
Not sure. I tried the cap on the other coil and it refused to spin. If I remember I'll take the cover off the motor again and take a voltage reading.
@TheInfoworks6 жыл бұрын
Hi. In the video it sounded like the cap was too large, giving that strained motor sound. Cheers
@combatzonepaintball81994 жыл бұрын
Do you know if there is a heat shield inide the heater coil? I have a stella idrobase model but there is a heat shield which covers half of the internal coil. Dont knnow if this was a bodge by someone
@hengkyiw3 жыл бұрын
I have idrobase stella too..the boiler is not working now.
@andyscott33667 ай бұрын
Hi where did you get the electric starter from thanks
@DavidMcLuckie7 ай бұрын
Was a while ago now. But I think off eBay. As long as you match the old one to the new one it should be fine. I did have to email the motor manufacturer for the wiring diagram though.
@andyscott33667 ай бұрын
Thanks
@elvinholmes23853 жыл бұрын
What model number is this pressure washer
@theautisticarborist68462 жыл бұрын
It’s a heavily bastardised cleanwell H11/100.
@dangerousfreedom49656 жыл бұрын
Scotland?
@sergiourquijo40005 жыл бұрын
Hello. I need your help man. Does the spark keep going after the flame is burning??
@DavidMcLuckie5 жыл бұрын
On the one I fixed yes.
@obviouslytwo4u3 жыл бұрын
The spark should stop after 30 seconds to stop the contactors and transformer overheating. They will be a timer wired in conjunction with the flyback transformer.
@tobybrown11793 жыл бұрын
My karcher hds stays on to ignite fuel
@CBRadiouk12 жыл бұрын
all the hot machines i work on, the spark keeps going. most machines have the blower motor and ht transformer wired together. in case ayone points this out, some machines have the blower fan on the back of the main motor.
@nickyogorman15903 жыл бұрын
Be careful, that igniter put me asleep one time !!!!
@DavidMcLuckie3 жыл бұрын
Yeah, I thinks it 25,000 volts or more.
@johnphillip17116 жыл бұрын
Did you say the water was in your crocs? If so seriously...crocs...what is wrong with you man? ;-) Not the first time I've forgotten to put some bit or other on that flows water and got drenched / ended up looking like I've wet myself. Your getting there, its always the way, you find that "one simple fault" is in fact masking about 20 other ones...and whoever designed it didn't consider it would a) be in a car, b) in a frame, c) in a confined space or d) people who work on these things dont have hands the size of a 3 year olds...
@DavidMcLuckie6 жыл бұрын
I was once like you. I said to my mate 'what are you wearing?'. He told me they were crocs and gave me a shot of them. He nearly didn't get them back. They are the comfiest things I've ever worn.