Brother,if it's a concealed dB and more number of conduits are coming to top and bottom of db,and no enough space on top and bottom of db for conduit to enter , then how would you manage that situation
@Team.4elseif5 жыл бұрын
Sooperb cheta....good presentation....technician um puliya...adipoli work....
വളരെ ഉപകാരപ്രേതമായിരിക്കുന്നു. നന്ദി ഇത് A To Z അതായതു electricity line മുതൽ switch board വരെ വിഡിയോ ഇടുമോ 🙏
@moiduakode34535 жыл бұрын
ELCB wiring video ഒന്ന് ചെയാമോ
@malluengineer18385 жыл бұрын
ചെയ്യാം
@sharafupng5 жыл бұрын
Oru sadarana veedu yengine cheyyam yennoru video cheyyamo yendokke venam cappasitty elcb amp yennokke yethara kg vair light nu mm yethara venam ac ku mm yethara yellam pardekshikkunnu
@malluengineer18385 жыл бұрын
Stay tuned
@krishnakumarsankarankutty77365 жыл бұрын
Video is very good, Please use proper tools for termination, like wire stripper. Which country standard is this ?
The incommer cable should be 16 square mm or above. Am I right. Thanks
@malluengineer18385 жыл бұрын
Depend on load
@malluengineer18385 жыл бұрын
If it is 40A 10mm^2 enough. 16mm^2 for 63A 25mm^2 for 80A...etc
@vimalraj-xs2xp5 жыл бұрын
oru MCB il engane aanu r y b wire orumichu vannat..?
@malluengineer18385 жыл бұрын
3pole mcb yil mathrame r y b connect ചെയ്യൂkzbin.info/www/bejne/kGfSf2x7a5qho6M
@sonupradeep19965 жыл бұрын
3 phase mcb kittum..atil ryb anu
@AnilKumar-rg5vx5 жыл бұрын
Gulfil evideya u a a
@malluengineer18385 жыл бұрын
Dubai
@AnilKumar-rg5vx5 жыл бұрын
@@malluengineer1838 njanum dubailayirunnu eppol nattil electrical works cheyyunnu
@dhanilgovindnsunnniunnni1715 жыл бұрын
Sinhlr phase db dresssing kanikua
@brilliantbcrrth41984 жыл бұрын
ങ്ങനെ wire അടുപ്പിച്ചു ടൈ ചെയ്താൽ ഏതേലും ഒരു വയർ ചൂടായി ഉരുകി മറ്റ് വയറിലേക്കു ബാധിക്കില്ലേ
@malluengineer18384 жыл бұрын
ഇല്ല,
@devdasambadi40654 жыл бұрын
അഥവാ അങ്ങിനെ സംഭവിച്ചാൽ MDB യിൽ സർക്യുട്ട് കട്ടാവും,, പിന്നെ ഒരു കാര്യം ഓർമ്മിപ്പിക്കുന്നു Pin Type lug use ചെയ്താൽ നല്ലതാണ് കാരണം ചില വയറുകളുടെ ഇൻസുലേഷൻ MCB യിൽ കണക്ട് ആയി സർക്യൂട്ട് കിട്ടാതെ വരും അത് Ringസർക്യുട്ട് ആണെങ്കിൽ അറിയില്ലാ,, എനിയ്ക്ക് ഒരു അനുഭവമുണ്ട്,,
@babujose44224 жыл бұрын
അടിപൊളി ആയിട്ടുണ്ട്.... ഒരു സംശയം ഐസൊലേറ്ററിൽ(4pole വേണ്ടേ )ന്യൂട്രൽ കണക്ട് ചെയ്യണ്ടേ
@malluengineer18384 жыл бұрын
Neutral separate oru connectoril ആണ് connect ചെയ്യുന്നത്
@ajithsasidharan14555 жыл бұрын
Please do a video on central battery system.
@malluengineer18385 жыл бұрын
ചെയ്യാം
@subimariyamjejo81935 жыл бұрын
Make a video about different types of panels form 2 ,form 3 etc
@malluengineer18385 жыл бұрын
Please stay in touch
@bihasbayern27415 жыл бұрын
CT യുടെ SHORT CIRCUIT & PT യുടെ OPEN CIRCUIT എങ്ങനെ ചെയാ എന്ന് KAANIKO, പിന്നെ CT & PT ratio ഒന്ന് explain cheyo, നിങ്ങളുടെ super ആണ്
@malluengineer18385 жыл бұрын
Thanks
@ajithkumaraha3 жыл бұрын
korachi korachi Malayalam ariya. Good Job keep it up. from Srilanka.
@althafaman18532 жыл бұрын
Db trouble shooting vdeo chayyamoo
@arjunnk41744 жыл бұрын
R Y B WITH NUTRAL ഇവ എല്ലാം ഒപ്പം ഒരു പൈപ്പിലൂടെ കൊണ്ട് വരുന്നത് കുഴപ്പം ഉണ്ടോ
Where u get this type dB in dubai or Sharjah ?pls specify the brand ,,,
@malluengineer18385 жыл бұрын
Dubai, alfanar
@Percyshelton5 жыл бұрын
Thanks
@shanijani22374 жыл бұрын
Bro may i have your contact nbr plz.? Ir plz send "Hi" on WhatsApp to me 00971581363904
@Sabithksidhique Жыл бұрын
Incomer and outgoing cable should be segregated. Incomer isolator is in left side but Incomer cable glanded in right.
@shibukrishnan78095 жыл бұрын
3fice power factor fix cheyyunnathu Engane 25kv
@malluengineer18385 жыл бұрын
Need total connected load
@malluengineer18385 жыл бұрын
25kv or kw
@malluengineer18385 жыл бұрын
Also need your present power factor
@varghesevg4 жыл бұрын
DB schedule cheyunnadinte video cheyaamo?
@khadeejap73314 жыл бұрын
ഐസൊലേറ്ററി eലക്ക് വരുന്ന 10mm കേബിളിൽ ന്യൂട്രൽ കേബിൾ കണകറ്റ് ചെയ്യുന്നത് വീഡിയോയിൽ കാണുന്നില്ല:
@malluengineer18384 жыл бұрын
3pole isolator ആണ് use ചെയതത്, neutral connectoril ആണ് terminate ചെയതത്, അത് വിഡിയോ യില് mention ചെയ്തിട്ടുണ്ട്
@shylucbshylucb41704 жыл бұрын
Good work nammude workkum ithupole thanne ( phsae colour code koode undagil poli ayene
@SasiKumar-rw9hq4 жыл бұрын
Thanks for very good video and description
@muhammedsabic87735 жыл бұрын
Helpful 👍👍👍,DEWA standard um indian standard um Ulla difference topic cheyyamo
@malluengineer18385 жыл бұрын
Thanks, stay tuned
@ramrah47345 жыл бұрын
Eth vertical db aano
@malluengineer18385 жыл бұрын
Alla, vertical DB internal busbar connect anu
@santhoshthombra35683 жыл бұрын
ഏത് കേരളത്തിലാണോ അതോ purathano
@muhammedkabeerkabeercochin36393 жыл бұрын
Valare bamghyulla D B dressing
@subimariyamjejo81935 жыл бұрын
Very useful video chetta..
@malluengineer18385 жыл бұрын
Thanks
@jamsheerali8994 жыл бұрын
Super.! Waiting for more videos
@sasik74564 жыл бұрын
ELCB ഒരെണ്ണം വച്ചാൽ എന്താണ് കുഴപ്പം
@malluengineer18384 жыл бұрын
Load differents varum, പിന്നെ RCCB റേറ്റിങ് DIFFERENTS ഉണ്ട്
@AbuSaleemMdr5 жыл бұрын
*3 phrase db യിൽ റോട്രി add ചെയ്യുന്നതല്ലേ... ഇതിൽ ഒരു line cut ആയാൽ. അതിലേക്ക് കറന്റ് എങ്ങനെ കൊണ്ട് വരും* ❓️❓️
@malluengineer18385 жыл бұрын
Sorry question മനസ്സിലായില്ല
@vipinug67025 жыл бұрын
6
@devdasambadi40654 жыл бұрын
dubai യിൽ ഒരു ലൈൻ മാത്രമായി വളരെ അപുർവ്വമായി മാത്രമേ കട്ടാവാറുള്ളു,, ഇനി കട്ടായാൽ തന്നെ എല്ലായിടത്തും Stand by Power ഉണ്ടാകും അതുകൊണ്ട് നാട്ടിലെ പോലെ Rotary Swicth Add ചെയ്യാറില്ലാ,,,
@muhammedpv1584 жыл бұрын
kidu 👌
@AjithM-uj2kl2 жыл бұрын
Good presentation 🙏
@syedsheik87804 жыл бұрын
Great explanation thanks bro..
@sreejithsasidaran65355 жыл бұрын
Show that a DB with RCBO is attached
@malluengineer18385 жыл бұрын
Here in Dubai, Normally RCBOs are not used in DBs
@ArunKumar-ex4bi3 жыл бұрын
Super are be electrical work Video send this bro
@jinukrishnang91795 жыл бұрын
63 amps power nu cable size ethra venam ?? 125 amps num ?? athu engane calculate cheyyam ?? oru 10Sq mm cable vazhi maximum ethra ampere use cheyyam??