Sir we love yr videos a lot, plz be concern on our interest of learning through yr videos And teach us continuously
@structuralanalysisanddesign4 жыл бұрын
It gives me immense pleasure to know that you all love my videos, definitely i will try my best to upload videos regularly
@rohitshetty87582 жыл бұрын
@@structuralanalysisanddesign why you took 1.5
@rohitshetty87582 жыл бұрын
@@structuralanalysisanddesign sir
@mdhasann26402 жыл бұрын
@@rohitshetty8758 it's an factor of safety
@NasirYousuf-m6b16 күн бұрын
i'm attracted by the beautifull and simple way you made me understand this lesson thanks sir
@bigfore70833 жыл бұрын
I wonder, how on earth someone put a dislike to such well polished explanation
@structuralanalysisanddesign3 жыл бұрын
Thanks for appreciating, some people will be there to dislike but it gives us more motivation to do more videos which are helpful to civil engineering community
@saifaly359 Жыл бұрын
A very thank you sir. Because of you I passed this subject
@vikeshtalda10694 жыл бұрын
Thank you sir, your explanation is so simple, we understand like a piece of cake.
@structuralanalysisanddesign4 жыл бұрын
So nice of you, these kind of words will motivate to come up with more videos, support us by sharing, all the best
@fistonndongalo1393 жыл бұрын
SIMPLY THE BEST , Keep up the great work Sir
@structuralanalysisanddesign3 жыл бұрын
Thanks a lot! Keep supporting by watching and sharing
@ashokkumarar43343 жыл бұрын
I found something wrong i.e., Instead of taking Mu=0.138 fck b d2 for Fe415 you took Mu= 0.133 fck b d2 which is for Fe500. I have been seeing all your videos and its very clearly explained.. Keep doing brother..
@slgamerty90769 ай бұрын
Ur my god plz continue your vedios 🎉🎉 super explanation sir 😊
@yuwabharatshakti36034 жыл бұрын
First of all gd evening। Your videos is very helpful in ssc je mains paper।
@structuralanalysisanddesign4 жыл бұрын
Good Evening, If helpful kindly share the content among your friends circle
@vivekruthvik74688 ай бұрын
here before 3 days of my exam
@abhijeetbhatnagar35623 жыл бұрын
Thank you sir, very well explained
@structuralanalysisanddesign3 жыл бұрын
You are welcome, I am happy this video helped you, keep watching and sharing, all the best
@tendayimapawona3237 Жыл бұрын
Perfect, well explained thank you sir
@structuralanalysisanddesign Жыл бұрын
So nice of you, all the best, keep sharing
@michaelshongwe99952 жыл бұрын
Clear explanations, thanks 🙏
@surajthapa10593 жыл бұрын
thanks sir from nepal
@structuralanalysisanddesign3 жыл бұрын
Welcome, keep watching and supporting
@MasterCivilEngineering4 жыл бұрын
Awesome video Sir
@structuralanalysisanddesign4 жыл бұрын
So nice of you
@sarfrajahmad28504 жыл бұрын
You are fabulous sir
@structuralanalysisanddesign4 жыл бұрын
So nice of you, thanks a lot, keep watching and sharing
@structural_design80013 жыл бұрын
It is good practice to provide at least 25 % of the Ast (minimum) and subject to two bars (minimum) at compression side also, even if it is not required,
@shashank_d_a Жыл бұрын
Thank you so much sir. Please make more videos of different methods. ❤️❤️
@structuralanalysisanddesign Жыл бұрын
Welcome, I will try to come up with more videos, keep watching
@civilexplorer70383 жыл бұрын
Sir, In the problem u have taken Fe415 grade but while finding d u took Mu= .133fckbd2 which is for Fe500. As well Mulim comes out to be 94.46kNm
@adityajoundal85002 жыл бұрын
Thanks sir 👌👍
@armyofficermanishsharma50394 жыл бұрын
Happy Navratri sir
@structuralanalysisanddesign4 жыл бұрын
Happy Navratri Manish
@NileshRoamingNITIAN3 жыл бұрын
Just Amazing 🔥🔥🔥🔥
@saipraneethasp98473 жыл бұрын
Sir, I just watched ur videos for ssc je mains.. tnx for this neat nd clean explanation sir.. Pls start Steel if possible..
@structuralanalysisanddesign3 жыл бұрын
Thank you for appreciating my lectures, yes i am starting design of steel structures in a very detailed manner very soon, keep watching and sharing with your friends
@masoodmomin52964 жыл бұрын
Thank you very much sir. What is live load you considered. Is it brick dead load of bricks. Also called as super imposed load
@structuralanalysisanddesign4 жыл бұрын
Yes overall live load
@masoodmomin52964 жыл бұрын
@@structuralanalysisanddesign we take live load Max upto 3 kn/m2 on slab. What is that load. Which taken as live load in problem.
@structuralanalysisanddesign4 жыл бұрын
Nowhere they had mentioned from where load was coming, its assumed overall load coming on beam say brickwork etc
@amansah93544 жыл бұрын
tq very much sir for this video
@structuralanalysisanddesign4 жыл бұрын
So nice of you, all the best, keep watching and supporting
@adityajoundal85002 жыл бұрын
Excellent 👍
@advselvaa55553 жыл бұрын
Superb. Thank you sir.
@sheetal_baisa2 жыл бұрын
great efforts.
@vkchowdary79244 жыл бұрын
Thank you sir, will you make video on Continuous slabs.
@structuralanalysisanddesign4 жыл бұрын
Sure, your request noted
@Anuradha1354 жыл бұрын
Very Nice Video Sir 👍👍
@structuralanalysisanddesign4 жыл бұрын
Thank you mam
@RohitSingh-xb8ic3 жыл бұрын
How to know whether to use 2 legged stirrups or 4 legged stirrups
@amiteshsingh86824 жыл бұрын
*Sir, can you upload videos of design of steel structure,bolted connection,joints,tension members and compression members?*
@structuralanalysisanddesign4 жыл бұрын
Sure soon i will try to upload
@amosopiyo64034 жыл бұрын
Good explanations and can you please upload a video on simply supported slab with cantilever on both sides
@structuralanalysisanddesign4 жыл бұрын
Will try to do it, thanks for watching
@biswasmihir00012 жыл бұрын
Thank You Sir. Please give us a design calculation on rcc cantilever slab.
@yuwabharatshakti36034 жыл бұрын
Spacing of sturip remains constant in the middle of the beam or spacing decreases on the fixed portion।plz tell।
@structuralanalysisanddesign4 жыл бұрын
As the Shear force will decrease as you we go towards free end, spacing can be increased as you move towards free end, In this problem i have kept same spacing
@nksconstructionworld28193 жыл бұрын
Thanks you sir
@structuralanalysisanddesign3 жыл бұрын
welcome, keep watching and supporting
@manikumar75013 жыл бұрын
sir, as the adopted reinforcement is Fe415 , after concluding the section as under reinforced why did you take Mu = 0.133 fck bd2. 0.133 is for Fe500 and for Fe415 we have adopt the formula Mu = 0.138 fck bd2.
@professor7666 ай бұрын
Yaa, taken value of Mulim is wrong
@vikeshtalda10694 жыл бұрын
Sir, while calculating the dead load, why be always multipy it by 25 ?
@structuralanalysisanddesign4 жыл бұрын
25KN/m3 is density of concrete, some textbooks take 24, both values you can take
@sasikumartherayil96204 жыл бұрын
Sir Your efforts are good Go for IS Code Minimum mix is M25 for rcc. Now a days 415 steel is not available. Make it more practical by Bring a project in to it. So that the students will understand why it is a cantelever. Why it is starting from column. Tell how the load is coming. Shiw full details then come to the xantelever
@structuralanalysisanddesign4 жыл бұрын
Good suggestions, i will try to do it, but M20 is minimum mix for RCC as per IS Code and problem is solved as per IS code only
@sumeetavhad78493 жыл бұрын
Sir please make video on combined footings and structural analysis topic
@soimhossen30232 жыл бұрын
Beautiful
@vikeshtalda10694 жыл бұрын
Also sir, in some cantilever problem, I have seen, the addition of wt of rib, what is the formula for it, and what is rib actually?
@structuralanalysisanddesign4 жыл бұрын
Rib comes in T Beam, analysis of T beam is there on this channel, kindly check
@vikeshtalda10694 жыл бұрын
Thank u so much 💓
@shanimat30034 жыл бұрын
Awesome!! Sir.....can u upload the lintel design?
@structuralanalysisanddesign4 жыл бұрын
Thank you, your request noted, soon i will try to upload
@gauravarya24193 жыл бұрын
Hi sir, really loving all your videos. Could you please clear one of the practical doubt of the following case. It is for my home site. How do I extend a balcony of 1.2x2.5m of a preconstructed apartment using cantilever beams? It is a third floor. Column size is 9x12 inches. I am going to use 6 top bars of 16 mm and 3 bottom bars of 16mm, curtailing 2 top bars at 0.6m with the main slab bars of 12mm and distribution bars of 10mm. Stirrups bar of 8mm with spacing 4 inches center to center. cover block of 30mm with hook angle 135 degrees and angling downwards. slab thickness at support 6 inches As it is preconstructed apartment, I could not extend the bar back, however I have reclaimed around 0.6m beam and slab bars after demolishing beam and slab. Will this be enough for lapping length of slab and development length of cantilever beam. I plan to create a brick wall (4 inches, 9 feet ceiling height) to include this space inside to be used as a kitchen counter of 2 feet and overhead storage. What modifications I can perform to ensure safety. Total reinforcement area is now 3feet 6 inches cantilever, column(9″x12″), 2feet overlapping length.
@ARKK-ORGANIZATION4 жыл бұрын
Sir this problem solved by LIMIT state or WORKING state method?
@structuralanalysisanddesign4 жыл бұрын
Limit State Method, in this channel everything will be by limit state method
@FareedKhan-ec5iy3 жыл бұрын
First i would say, You are a true gem dear, appreciated your effort and the way you explain things A to Z, really really impressed. Keep this great channel going. My question is what if Tv
@structuralanalysisanddesign3 жыл бұрын
Thank you so much for appreciating me and for best wishes to the channel, this kind of motivating words keep me motivated to do videos, keep watching and supporting. To answer your question, if there is no need of shear reinforcement but still we have to provide minimum shear reinforcement in the form of stirrups, kindly refer IS 456-2000 Page 72, clause 40.3
@FareedKhan-ec5iy3 жыл бұрын
@@structuralanalysisanddesign Thanks for your answer. Sir will you provide a lecture on deep and hidden beam design if yes then expected time?
@structuralanalysisanddesign3 жыл бұрын
I cant guarantee but your request noted
@brjangid308811 ай бұрын
Is it not necessary to check against overturning moment.
@emaaduddeen Жыл бұрын
sir how did you calculated hanging / bottom bars?
@structuralanalysisanddesign Жыл бұрын
That is just nominal we can provide
@ianballesteros68153 жыл бұрын
If Nominal Shear stress is bigger, does it mean Shear Design is not required? Do I still need to provide stirrups? And what will be the spacing if ever?
@chukwuagoziefavour812Ай бұрын
Sir pls which of the authority code are you using?
@arnabsikder59172 жыл бұрын
it is limit state or working state
@alfavarghese12424 жыл бұрын
Can you explain more about negative moment and positive moment
@structuralanalysisanddesign4 жыл бұрын
That comes in continuous beam, soon i will try to upload it
@alfavarghese12424 жыл бұрын
@@structuralanalysisanddesign awaiting for that video
@nepalitechnocrats51683 ай бұрын
How much % of main steel we should provide on bottom side (hanger bars)?
@yangchinlhamu2104 жыл бұрын
Sir, the same problem in BC Punmai book ,they are not calculating effective span and have directly taken given length. Sir can you tell in cantilever problems excluding the given clear span problem, where we should calculate effective span and where not ?
@structuralanalysisanddesign4 жыл бұрын
Simply supported beam its necessary
@theexecutioner35102 жыл бұрын
Sir which bool did you refer for studying design of cantilever beam. Jain? Should I commit this solution?. Pls rply sir.
@darshancalldarshu64132 жыл бұрын
Bro you can upload estimation long wall and short wall method and centre line method
@structuralanalysisanddesign2 жыл бұрын
Already uploaded, kindly watch ir
@NehaNaaz-o6j4 ай бұрын
Now a days using Fe 500,550 Expecting design of rectangular footing on this subject
@yangchinlhamu2104 жыл бұрын
Sir in some books b=0.5 D (overall depth) . And you are solving by b=0.5d (effective depth). Is it okay to use both ?
@structuralanalysisanddesign4 жыл бұрын
As far as it is safe than there is absolutely no problem
@newera57733 жыл бұрын
Hello Sir!! Your explanation skills are outstanding. These are on the great videos of RCC design sir at 25:49 we use 2nd formula of tv am I right or wrong.
@samcivil97723 жыл бұрын
Sir if point load@end then how it is design
@shyamsundaryadav87523 жыл бұрын
Sir, magnel method samjhadijyae naa
@nilakanthapanda42784 жыл бұрын
Deflection ?
@vijaybhasker29283 жыл бұрын
sir please make a video about design dog-legged rcc stair cases
@sumanbarat22812 жыл бұрын
I think d check is 0.138b D2 fck in place of 0.133 for fe415
@opendicharles31273 жыл бұрын
can u also us how to do the curtailment. and also how to design to eurocode2
@AnkitMaurya-gs2po10 ай бұрын
Plz explain how will be b = 2d/3....🙏🙏🙏🙏
@affu21042 жыл бұрын
In all problems u have not solved for check for development length..... Is it necessary to check or not..?? Plz reply
@yogeshnegi1090 Жыл бұрын
same question
@gujjugamer7585 Жыл бұрын
Which method is this WSM OR LSM
@structuralanalysisanddesign Жыл бұрын
Limit state method (LSM)
@akashmadar33962 жыл бұрын
What is nominal shear stress
@praveencivilengineer3 жыл бұрын
Bro can u design the cantliver T beam..... With 6ft from wlla
@chrisk8z2 жыл бұрын
may i know what lvs stands for? ty
@structuralanalysisanddesign2 жыл бұрын
LVS - Legged Vertical Stirrups
@Alpha_Dad3 жыл бұрын
Sir, why have you not considered tapering the section and curtailment of steel?
@yogeshnegi1090 Жыл бұрын
same question
@Leo_Rocky_Rolex2 жыл бұрын
Sir what to do if design moment exceeds limiting moment??
@shashank_d_a Жыл бұрын
Sir please upload tapered cantilever problem
@DineshKumar-kd2nn Жыл бұрын
In case of fe550 checking for deflection It's k=0.6 L/d Max for cantilever is 7 xk=4.2 Provided is 3000/450=6.667 It's failing In deflection What should I do
@oscarvaron43842 жыл бұрын
What Sizes support??
@onlineteacher91714 жыл бұрын
Sir, From Which Book is page 37???
@structuralanalysisanddesign4 жыл бұрын
Its IS 456-2000 Code for RCC
@bimalkachhap9750 Жыл бұрын
Pl post the detail calculation sheet paper of design for RCC. cantilever beam, simply supported beam, overhanging beam.
@sathiyaprakash6382 Жыл бұрын
Where we have implemented design widh
@faizanuddin92724 ай бұрын
Sir you didn't divide shear force by 2 Why ?
@atharavupare64793 жыл бұрын
why the first stirrup inside the column?
@MushtaqAhmad-ro9qm2 жыл бұрын
Sir we have to design a beam of jib crane,plz sir if u cooperate with us , tomorrow we have a presentation about that....I will tell u about the required values etc
@aquibmohd3 жыл бұрын
20:16 how to get this formula ?
@shadabanwar61994 жыл бұрын
Sir please upload numerical on shear and bond and also design of doubly reinforced beam as soon as possible please sir it's humble request
@structuralanalysisanddesign4 жыл бұрын
Next video i will put on design of Doubly Reinforced Beam
@structuralanalysisanddesign4 жыл бұрын
Design of Doubly Reinforced Beam Uploaded, kindly check
@gauravarya24193 жыл бұрын
@@structuralanalysisanddesign how do you get to this formula to calculate ast in step 5,
@structuralanalysisanddesign3 жыл бұрын
@@gauravarya2419 Its based on derivations, you can find this formula in many standard text books
@BeardMan1. Жыл бұрын
Can you change the clickpad 😊
@sarttfft2 жыл бұрын
I am going to make 5 ft length of cantilever beam. Size of column = 10'' x12". Any suggestions on placing of reinforcement, developmental length and hidden beam?..
@structuralanalysisanddesign2 жыл бұрын
I strictly suggest you to consult your local structural engineer
@sarttfft2 жыл бұрын
@@structuralanalysisanddesign if you dont mind, can you able to help me somewhere or the other way?
@rakshithvenkatesh98703 жыл бұрын
Hello Sir!! Your explanation skills are outstanding.. Thank u for such a neat/ detailed teaching.. huge respect! I just had one doubt sir.. at 40:09 u have taken the value as 1.6.. ( during the calculation of development length) , but i got the value as 1.92, can u please explain that step? Once again, Thank u soo much for such an outstanding lecture!!
@MissJYL0w3 жыл бұрын
Yah me too..i'm wondering how he get 1.6..i also got 1.92
@petraalbatra98983 жыл бұрын
Actually the total value after multiplying 1.2 and 1.6 comes out to be 1.92. so the value coming out is same. I was also a lil bit confused at that point.
@civilengineering953 Жыл бұрын
For HYSD bars we additional 60% i.e 1.6 ×1.2=1.92
@yuwabharatshakti36034 жыл бұрын
Why you have not cheak the development length that is come from 26.2.1to26.2.3.3c।plz tell sir।
@structuralanalysisanddesign4 жыл бұрын
I have done with 26.2.1 clause only, kindly check it
@petermapp59883 жыл бұрын
I love ALL...OF YOUR VIDEOS.As a do it yourselfer...without civil engineering background...in a world with persons who construct without civil enginerring and THE KNOWLEDGE from your channel...why when i talk..and can explain WHY...the changes must be made..the foreman gives me...THE EVIL EYE
@bhushankatore58686 ай бұрын
Curtailment of bars are not provided
@sprasanna19792 жыл бұрын
PLS CORRECT MU LIMITING FOR 415 is 0.138 not 0.133
@somnathmukherjee57943 жыл бұрын
Please upload a file of equal combined footing design.
@vanand98883 жыл бұрын
Coad book 📚 explanchai sir
@srushtissathish38083 жыл бұрын
👍
@chandanraj7095 Жыл бұрын
Shear ke calculation me clear span lete hai
@prof.pravinspatil1727 Жыл бұрын
kzbin.info/www/bejne/rYrClaN5rrR-aZY, refer this one
@saurabhrajputs4 жыл бұрын
U explained very well but there is 2 mistake one is major and one is minor 1) U took 0.133(Fe500) instead of 0.138(Fe415) 2) U didn't mention of clear cover and effective cover. PS: Plz do not get offend.
@structuralanalysisanddesign4 жыл бұрын
Thank you for telling the mistake yes its 0.138 i agree, i will put this correction in description box with timings, this is the first i made a mistake in my video and thanks again for letting me know, and as far as possible one can take minimum effective cover. Keep watching and keep sharing
@sushilsawant6688 Жыл бұрын
😢
@multicolor103 жыл бұрын
Interesante presentación profesor. Solo intento aportar un vídeo dejo link sobre algunos aspectos. kzbin.info/www/bejne/nXq1o4aMicSrgrs
@gnaneshpramanik5982 Жыл бұрын
Lintel design
@prof.pravinspatil1727 Жыл бұрын
kzbin.info/www/bejne/bp-ag6CFop6faLs, refer this one