Just incase next time swap that 90 for a sanitary tee with a clean out.
@ShouldBeGood8 күн бұрын
Great idea! I will definitely have to do that on the next one!
@brianc3481 Жыл бұрын
Good work, hopefully that works flawlessly.. aavs are the best for stuff like that
@jamesguiberteau660711 ай бұрын
😂 should be good. Lived by this philosophy all my life and i guess i turned out "good"
@ShouldBeGood11 ай бұрын
it's a proven method 😂 Thanks for watching!
@laurasullivan669021 күн бұрын
Question for you! I am required to have an air gap between the 3 comp. sink and grey tank. Do you have one? If no, how would you have done this with an air gap? My idea is a floor sink drain but yours looks better.
@laurasullivan669021 күн бұрын
air gap bottom element minimum 4 inches wide. Grey holding tank external under the trailer, directly under the sinks.
@ShouldBeGood21 күн бұрын
@@laurasullivan6690 This system does not have an air gap. I am definitely no plumber but I have seen restaurants with the air gap system and they put it right above the p-trap. So I would just have an open pipe coming from the last drain going into 4" air gap fitting and then attached to the p-trap and down into the grey tank. I would skip installing the air admittance valve since you will have the air gap. Good luck on your project and thanks for watching!
@laurasullivan669019 күн бұрын
@@ShouldBeGood thanks so much for your reply! Good luck to you as well
@chrisheiberger36858 ай бұрын
Nice video, this was exactly what I was looking for, as I'm doing the same set-up in a small bar area.
@ShouldBeGood7 ай бұрын
Thanks for watching and good luck on your project!
@A1DeliandSmoke13 күн бұрын
So to become certified by the New York state you can use pvc?
@KaySancoppermug3 ай бұрын
Thx for the video .
@ShouldBeGood3 ай бұрын
Thanks for watching and good luck on your project!
@velascofrancisco7911 ай бұрын
Si I made one like it thanks to you
@prid12349 ай бұрын
Since you installed a p trap with no union, how is one supposed to service this and take it apart without cutting everything out? Also would recommend a cleanout on the vertical drain before it goes through the floor.
@ShouldBeGood9 ай бұрын
The p trap I installed has a drain plug for servicing and the vertical pipe has an air admittance valve that can be removed to clear any clogs. Should be good 👍🏼
@larrywilliams48163 ай бұрын
where are your paper gaskets?
@ShouldBeGood3 ай бұрын
@@larrywilliams4816 I don’t use the friction gaskets, just lubricate the rubber gasket and the locknut tightens right up. Thanks for watching!
@MichaelZerai7 ай бұрын
Thank you so for your help Can you help me for the leg of the sink mount to the trailer what size mount you use
@ShouldBeGood7 ай бұрын
1 5/8" Here is what I used amzn.to/3Wne7U2
@MichaelZerai7 ай бұрын
@@ShouldBeGood thank you again be bless more and more
@juanbeltran76965 ай бұрын
Any video how insulating wall for trailer
@ShouldBeGood5 ай бұрын
No, I just cut 1” foam insulation to fit between the framing
@Gary-f2j2 ай бұрын
What state do you live in. I see a ventless water heater?
@ShouldBeGood2 ай бұрын
CO
@Jason-crypto3 ай бұрын
What size dimensions is the grey water tank so that both fresh and grey fit under sink?
@ShouldBeGood3 ай бұрын
I didn’t install my grey water under the sink, only freshwater.
@scottfung77005 ай бұрын
The p-trap is used to block off sewer gas. However, your vent pipe, which carries sewer gas, ends under the sink's drain board. What is the point of installing a p-trap then?🤔🤔
@ShouldBeGood5 ай бұрын
Hi Scott, that is not the vent under the drain board. It is an air admittance valve, which only lets air into the pipes to increase drain flow and prevent negative pressure to further prevent gasses from coming back up through the pipes. The gray tank is vented on the outside of the trailer. Thanks for watching!
@derekmitt2310 ай бұрын
I think that sanitary T is supposed to be a wye fitting. Looks good other than that.👍