Sir you give real understanding of electrical world
@petarsimic45753 жыл бұрын
very useful video and great teacher!
@sahilsrivastav80616 жыл бұрын
Thanku sir...u r teaching ability too good..enjoy....,,
@ElectricalisEasy6 жыл бұрын
Thank you so much..Please do consider sharing the videos with your friends and anyone who might find them.helpful
@Kurogane-el2vq5 жыл бұрын
thanks sir its really helpful. I really appreciate it.
@ElectricalisEasy5 жыл бұрын
Glad to be of help, also do consider sharing the videos with your friends and anyone who might find them helpful...
@cholomsury15485 жыл бұрын
Much appreciation sir
@siddalinga7865 жыл бұрын
Sir I need a clarification I have 3 disel generators each generator have 50kw,my total output load is 150kw. If remove the 1 generator(cutoff) the power will be a 100kw,if power changes, frequency will changes, but here showing that voltage and frequency won't change, how can you please explain sir
@ElectricalisEasy5 жыл бұрын
The voltage and frequency remains constant only when the generator are connected to infinite bus bar
@jyotiranjangiri47096 жыл бұрын
in the last point, you said efficiency will decrease if the machine will not run at full load .. are you saying that input to the machine will be constant and power output is reduced due to the decrease in the load demand?
@ElectricalisEasy6 жыл бұрын
That is.one way to think ...see if your are not using your input power fully, then the difference between input and output is the losses right, which can be heat loss, loss on form of vibrations , accoustic energy and so on..
@mercidesbenz5 жыл бұрын
Hallo Varun D Nair, I realy appreciate your lectures ins the play list "parallel operation of alternators". For that i have tow questions. First one, do you have recommended books and material concernig this topic? And second one, is it possible to you to do an noteher lecture about "parallel operation of alternator" which shos the effect to the load sharing and the prime mover when, changing the droop setting? For me it is very intresting how the behavior of the prime mover changes, when one generator is operating in isochronous and the other in droop mode. Are they some how fighting each other when the load is changing? Hope hearing from you soon and waiting for oter nice lectures from you. Best regarts.
@ElectricalisEasy5 жыл бұрын
Lecture number 26 to 30 deals with areas you have asked...
@abdullahalmiraj35936 жыл бұрын
Sir which reference book do u follow for this lecture?
@ElectricalisEasy6 жыл бұрын
Electrical machinery fundamentals by Chapman
@sehrnazurdu6 жыл бұрын
great sir, are you following e machine by Steffen j chspmay?
@ElectricalisEasy6 жыл бұрын
For synchronous machines mostly from Chapman, and some other books also for certain topics..
@RaselMia-gg1kz9 ай бұрын
Good sir
@comandernehal85676 жыл бұрын
nice
@deepchakraborty79475 жыл бұрын
Sir please upload the potier triangle and methods in synchronous generator 💓
@vishalkunyal76985 жыл бұрын
Sir please upload potier triangle and methods in synchronous generator
@hydrohubb93 жыл бұрын
i think you should use term 'phase relation' not 'phase sequence'
@DhavalPatel-iz7sq6 жыл бұрын
The phase sequence of alternator is R-B-Y ,If the direction of field rotations is reversed then the phase sequence will be A. R B YB. B Y RC. B R YD. Y B R
@sehrnazurdu6 жыл бұрын
sir you skipped the def of emergency generator kindly repeat plx
@ElectricalisEasy6 жыл бұрын
Emergency generators are generators that feed only the emergency loads