here is the step by step procedure on how to run synchronous generators in parallel. #seaman #generator #engine #seafarer #reefer #refrigeration #refrigerationcycle #refrigerationequipment #airconditioner
Пікірлер: 75
@jenishrajan89923 ай бұрын
I learnt lot of from this video.Thank you very much for uploading this video.
@terasakisingapore33962 жыл бұрын
Just completed the refit couple of months ago 😁😁😁😁. Hope you like our systems. Nice video!!!
@harishanam927 Жыл бұрын
Hello my friend, you are making very very useful video. I learned lot things from your video. I have one request to you. Plz make one video on three lamp parelling method in details .
@rhandycan12 жыл бұрын
Salamt madami. Dami ko natutunan sa channel na to
@leckyjake2 жыл бұрын
Thanks sa support
@rexandrew80128 ай бұрын
REally love you video. Best Explanation with handson Explanation😍
@goldCrystalhaze Жыл бұрын
Omron timers are quite troublesome i see...Thanks for the excellent videos you create for us!
@nigelpreddie69362 жыл бұрын
Awesome stuff that's worth learning...keep up the great work..!
@reubengrant3746 Жыл бұрын
Excellent work
@hancecrawford2 жыл бұрын
very enjoyable video you are good teacher :)
@komal25256 ай бұрын
Good information. Thanks for sharing
@yazanabusleman560311 ай бұрын
Very useful explanation
@ARzik-ei9ct2 жыл бұрын
Such a great work. Carry on. I would like to ask you to show us how to set the speed governor into doop mode ? So that the load sharing can be performed??
@allezvenga76172 жыл бұрын
Thanks for your sharing
@jeromewelch74092 жыл бұрын
Thank you Jake awesome tutorial
@leckyjake2 жыл бұрын
Thank you for watching
@reefercontainerph41822 жыл бұрын
Thank you for sharing your knowledge.
@auhyg62 Жыл бұрын
Thanks for share
@EdWo.channel2 жыл бұрын
Very awesome video.
@andrewsmart29492 жыл бұрын
older detroit diesel units had 3 lamps which flashed slowly as govnor was adjusted to voltage and frequency,then as they go dark on the flash cycle you threw in the breaker
@shyster7172 жыл бұрын
We have them lamps also on newer vessels, together with other stuff like synchroscopes and so on...
@mdfarukmia69217 ай бұрын
Very good
@davidmears94102 жыл бұрын
Very smart man LeckyJake
@filchaneco506 Жыл бұрын
basta pinoy! lakas yarn
@LeckyKenTv2 жыл бұрын
Thank you sir for sharing your knowledge, for free❤...
@khalilbenrezkallah66310 ай бұрын
I love you my friend thanks you helped me a lot
@monzurhasan35832 жыл бұрын
Awesome, i hope you share a Video of Emergency Generator battery charging system 💝
@charinath54452 ай бұрын
For Essential and Emergency generators on a ship, where are the AVR and governor controller typically located on a diesel generator? Are they housed together in the same control panel on the skid, or are they installed in a remote control panel separate from the skid? What is the standard practice or current trend? The capacities range from 1.5MW to 5MW.
@marioroma7325 Жыл бұрын
Great video, thanks.
@ВикторияЛирник-я9и2 жыл бұрын
Thank you these is good video
@vladifique2 жыл бұрын
Thank you! You made it look easy.
@hendersongina70592 жыл бұрын
Thank you leckyjake.. hope to work with you in future👍🏼👍🏼👍🏼
@Shiva68 Жыл бұрын
Thank you so much sir …
@rb1m4262 жыл бұрын
Mr secretary sa plc system naman😊
@vedatinal24712 жыл бұрын
First of all, thank you very much for your information. I am working as a chief engineer on a ship. There are 4 690 volt generators on our ship. When we parallelize the generators, the generator number 3 gives load too high deviation alarm. How we can solve this problem. I would be glad if you help.
@lawofnature199410 күн бұрын
Thanks with sadness Bro
@keything84872 жыл бұрын
AWESOME !!!!...thank you
@harishanam927 Жыл бұрын
And make one video. How to increase or decrease voltage by AVR.
@jagadeeshkumar9752 Жыл бұрын
Sir Can explain manual load sharing video ..I mean near generator
@gosho02 жыл бұрын
Do video on Magnetron change, Generator sensors (PT-100 etc.) , Generator protection and Winch faults
@KoHtet-pk6sb Жыл бұрын
thanks sir
@constantinolloveras58772 жыл бұрын
sir ask lng po ako,ano po ang problima sa isang unit namin nakung i on manually ang synchroscope ang pointer at synchronizing lamp ay steady lng at nag umiilaw naman
@gerageru15 Жыл бұрын
❤
@boybangastv30792 жыл бұрын
Salamat lecky Jake
@mfbfreak Жыл бұрын
How does the shaft generator work? Can it only be used when the main engine (and thus the vessel) is running at a specific speed, since the engine RPM is directly related to the frequency?
@Darklor_WCF Жыл бұрын
Most likely the ship has a variable pitch prop so while the ME RPM needs to be constsnt, it will still work the same way ultimately and the ship can traverse at any desired speed by varying prop pitch instead of ME rotation
@prescan70002 жыл бұрын
Why is the voltage around 260V? Isn't that quite high? I was expecting something around 230-250V (400V 3phase).
@prashanth64062 жыл бұрын
Hi, i have a question What will happen if we close the breaker but the synchronisation conditions are not met
@robertp72092 жыл бұрын
If it’s way out of sync, you could effectively wreck something, since the machine tries to change speed in an instant to match the others, which it can’t do. May sever a shaft or coupling or mounting bolts or worse case wreck windings. That’s a no no. The automatic as well as manual operation may have protective relays supervising the operation and if it sees a condition not to spec, will block closing of the circuit breaker.
@ajithottakandan33742 жыл бұрын
thank you
@yancri145 ай бұрын
What could cause one generator to displace another and take it out of parallelism?
@superconfort2 жыл бұрын
Thanks!
@gerageru15 Жыл бұрын
Dear i have 4 g but when i sencroniz 3 g will close one of them delay to close after one minut it will clos immediately the other 3 show revers power what will be the problem pleas explain to me
@dilkhushkumaryadav821010 ай бұрын
Apfc panel auto me pf maintain nhi ho pata hi keya karan hi
@edcarlos102 жыл бұрын
Hy Jake, How the PMS working is automatic panel ??
@jamesowusu-ansah5952 жыл бұрын
Thanks for the video…. But can I please get the circuit diagram
@MuhammadMujahidIqbal-l5v Жыл бұрын
Hi friend where are you from
@reyjames51442 жыл бұрын
Panu po pag nag agawan ng load yung 2 genset, anu po dapat gawin?o anu po mostly yung problem pagganun?.Salamat
@vedatinal24712 жыл бұрын
When the generator number 3 is on alone, the voltage and amperage values are normal, but when we parallelize the other generators, the amperage values in the generator number 3 increase too much and load too high deviation alarm is given.
@robertp72092 жыл бұрын
Are the “other” generators taking load once synchronized?
@zainahmedmalik6759 Жыл бұрын
its because on auto synchronization load vary and due to this variation of load some alarma come. it will be automatically adjusted ..... by the way good observation 👍👍
@seachest2 жыл бұрын
Sir , can you explain how the load balancing unit work , i don't get it yet
@robertp72092 жыл бұрын
The engine of the generator or generators you want to add load to has to be given more fuel. It doesn’t run faster but takes more of the load vs. the other generators on line at the time. Looks like the control marked with the word governor motor is what does it, at least in manual. If they have an automatic system there to do it fine or do it manually as auxiliary power demands change. I presume they have synchronous generators.
@leckyjameschannel33202 жыл бұрын
Ask lang ako sir lec my possibilty ba na mag blackout pag di ma timing ang pag synchronize?
@robertp72092 жыл бұрын
You have some leeway, have to read the specifications, if you close the sync breaker way out, you may do severe damage. Worse than blackout. The senior operators are trained in this practice.
@vedatinal24712 жыл бұрын
I changed the current transformers in generator number 3. I changed the syncronoscope. I changed the screen. I changed the cotroller. Unfortunately I couldn't find a solution. please help.
@christianmaniego1382 жыл бұрын
Sir lecky,how to fix the mcb computer system fail in synchonized panel is alarm indication??
@leckyjake2 жыл бұрын
just refer to your wiring diagram and trace the source
@wasiqzamir1731 Жыл бұрын
Hello sir i am fresh electrical engineer and want to go on ship kindly guide me through interview and 1st day
@demardemar58487 ай бұрын
Bakit di sabay mag control ng load sa gen 3 at gen 4. Inisa isa nya kala ko sabay dapat pag ganun load sharing
@helloworld402 Жыл бұрын
9:58
@314Chingo31411 ай бұрын
Do you got an e mail address maybe when i need help of better understanding in the future i can contact you..
@mechanicalengineeringtutorials Жыл бұрын
You did not even blow through the generator you started it directly?
@benjaminjacob6319 Жыл бұрын
Please sir can u give out your social media handle