No video

Earth electrode testing the proper way

  Рет қаралды 12,751

Residual Electrical

Residual Electrical

Күн бұрын

In this video im back at the new service i recently fitted to conduct some proper earth electrode tests after previously jsut getting a earth fault loop impeadance result.
Earth Electrode testing with Paul Meenan:
• Testing a ConduDisc ea...
If you enjoy electrical content please subscribe to the channel and checkout my links below 👇
M Y W E B S I T E ⚡
residualcurren...
M Y L O A D O U T 🛠️
residualcurren...
B I G B O O T S D I S C O U N T 🥾
bigboots.co.uk... - Use code RESIDUAL
U N I L I T E D I S C O U N T 🔦
unilite.co.uk/... - Use code RESIDUAL
J O I N T H E C H A N N E L 🤝
/ @residualelectrical
I N S T A G R A M 📷
/ residualcurrent
T I K T O K ♪
vm.tiktok.com/...
The works carried out in the video and the opinions shared are my own, and not representative of the associates and companies in the video.
This content is purely for entertainment purposes and is in no way a "how to", tutorial or educational video.
Please consult an electrician when dealing with any electrical installations.
#electricianlife #electrical #electricalengineering

Пікірлер: 42
@Jake_Baker_Electrician1997
@Jake_Baker_Electrician1997 Жыл бұрын
Not a test I have had to undertake often, so this video will be a massive help to refresh the memory in future! You’re probably the best KZbin Spark for informative content that looks awesome 👌 watched all your content and I’ve adopted a lot of the things you do into my own skill set which has helped me massively as an apprentice!
@walseee
@walseee Жыл бұрын
Where you been, we’ve missed you 😢
@TheHomeent
@TheHomeent Жыл бұрын
Once again you nailed it. Always great videos. Full of information and the job done properly, no shortcuts.
@bramcoteelectrical1088
@bramcoteelectrical1088 11 ай бұрын
good to see as not many have done the 3 lead test or understand how to carry out this testing good video thanks
@DarkShadowedOne
@DarkShadowedOne 11 ай бұрын
Only just had to use this sort of tester at work this week for doing lightning protection testing. Lucky you have a nice open area to drive your test stakes in for your video
@paulstimpson8977
@paulstimpson8977 3 ай бұрын
I went with a cheaper tester as testing can be done with as you say by 3 methods, my luck get called to a TT install with a fault no power (Fuse pulled) and what looks like a disconnected Earth Rod! Didn't do the job in the end because no one knew who pulled the fuse or why and other issues! But I would have been in a pickle not being able to prove the TT earth was sound prior to the Supplier (DNO had no contact and stated that without knowing why the fuse was pulled they would not reinstate) coming out and who knows when they would turn up! Would probably need to be there when they came.
@johnward5006
@johnward5006 Жыл бұрын
Top man! You nailed it and that's a plumber commenting!
@fredflintstone1
@fredflintstone1 11 ай бұрын
years ago I used a wheatstone bridge meter for testing earth rods in hospitals
@rattlehead85
@rattlehead85 Жыл бұрын
Fantastic video mate. Good reference material to go back on as this test is not one of the common ones and not many sparks could tell you how to do it. Calculations towards the end got a bit complex with the percentage deviation but how you explained it was great. Well done fella. Enjoy your content. 👍🏻👍🏻👍🏻
@fje1948
@fje1948 11 ай бұрын
Excellent video - you do thing’s properly! Many thanks Mike.
@corymac
@corymac Жыл бұрын
Great job! 👍🏼
@lowrybrock8272
@lowrybrock8272 Жыл бұрын
That’s really interesting stuff. And go ahead and admit it, those were your toys weren’t they? Good to see you back! Be safe out there!
@sergiofernandez3725
@sergiofernandez3725 Жыл бұрын
Great explanation Mike
@Engineer-Samibress
@Engineer-Samibress Жыл бұрын
Thanks for your time
@e5Group
@e5Group Жыл бұрын
coming along nicely
@tincanpete
@tincanpete Жыл бұрын
interesting and helpful video... thanks!!
@maximuspareo
@maximuspareo Жыл бұрын
It is ok 16 ohm ??? In my country we need 4 ohm for normal and 1 ohm for + lighting protection .
@adriatikkrasniqi1453
@adriatikkrasniqi1453 11 ай бұрын
How did you do calculations is 2.2 percentage. To ne work out 3.8 percentage..,
@abdulseaforth6930
@abdulseaforth6930 Ай бұрын
@@adriatikkrasniqi145316.2/16.56≈0.98 ie 2% difference
@alantowler9430
@alantowler9430 11 ай бұрын
excellent video.
@iosebbegiashvili8145
@iosebbegiashvili8145 6 ай бұрын
previously with efli test you have almost similar readings ,i wonder ,is it worthy to do potential fall test as well?
@chrismason3341
@chrismason3341 4 ай бұрын
Dno or supplier still not been out to reseal?
@flint1982769
@flint1982769 Жыл бұрын
Great video!!
@NabeelAhmad-gp5ps
@NabeelAhmad-gp5ps 2 ай бұрын
I haven't five years experience in this field...please guide me and help me i want work with you
@vioreltanasa988
@vioreltanasa988 7 ай бұрын
What are you doing when you measure to a industrial place and you cannot disconnect earth because are a engine in process
@martijn7924
@martijn7924 4 ай бұрын
Look up stakeless and selective earth testing. If money is not an issue, see earth clamp meters as well.
@SpikesMavic
@SpikesMavic 4 ай бұрын
But if the test Spikes are into dry ground, what will that measure ?
@abdulseaforth6930
@abdulseaforth6930 Ай бұрын
Dry ground - worst case scenario
@Riley_Jarvis_the_sparky
@Riley_Jarvis_the_sparky 10 ай бұрын
Lovely video bud keep it up 👍
@residualelectrical
@residualelectrical 10 ай бұрын
Thanks, will do!
@vioreltanasa988
@vioreltanasa988 7 ай бұрын
Rezistence should be under 4 ohms for civil and industrial ,and under 2 ohms for farming 😢
@vioreltanasa988
@vioreltanasa988 7 ай бұрын
You have only 1 electrode must be 3 in star connected
@electricalservicesmaroc
@electricalservicesmaroc Жыл бұрын
Hello man ❤❤❤🎉🎉🎉
@adriatikkrasniqi1453
@adriatikkrasniqi1453 11 ай бұрын
I done the calculations 3.8 percentage not 2.2 percentage…
@fje1948
@fje1948 11 ай бұрын
@adriatikkrasniqi1453 Hi. Can you please provide an analysis of your calculations - Thank you. I make it: max deviation from average 16.56 - 16.20 = 0.36 then (100/16.56) x 0.36 = 2.17% which is close to Mike’s result!
@adriatikkrasniqi1453
@adriatikkrasniqi1453 11 ай бұрын
@@fje1948 you have to do the highest minus average taken from 3 reading then divide by the highest + - 5% but not more then that…
@fje1948
@fje1948 11 ай бұрын
⁠@@adriatikkrasniqi1453 Thank you for your swift reply. Using Mikes readings: Highest 16.84 - Average 16.56 ---------- 0.28 Further using your wording: ‘Then divide by the highest’ 0.28/16.84=0.01662708 ??????????? Your detailed calculations using Mikes readings would be appreciated - Many Thanks.
@adriatikkrasniqi1453
@adriatikkrasniqi1453 11 ай бұрын
@@fje1948 than times by 100 %
@adriatikkrasniqi1453
@adriatikkrasniqi1453 11 ай бұрын
@@fje1948 I the end of the day is good to contribute with this calculation for us as learners maybe I am wrong Mike calculation I could be right I don’t but he to explain the calculation.
@vioreltanasa988
@vioreltanasa988 7 ай бұрын
I am not satisfied with this
@vioreltanasa988
@vioreltanasa988 7 ай бұрын
Electrods sh
@picklenipples
@picklenipples Жыл бұрын
awesome vid!
Calibrating my own multi-function tester
10:52
Residual Electrical
Рет қаралды 4,6 М.
АЗАРТНИК 4 |СЕЗОН 1 Серия
40:47
Inter Production
Рет қаралды 1,1 МЛН
1ОШБ Да Вінчі навчання
00:14
AIRSOFT BALAN
Рет қаралды 4,4 МЛН
Or is Harriet Quinn good? #cosplay#joker #Harriet Quinn
00:20
佐助与鸣人
Рет қаралды 46 МЛН
Florida Man Challenges Me to Build a Massive Winch
41:23
Watch Wes Work
Рет қаралды 247 М.
EMERGENCY Job Means One Thing (Earth Rods) - Electricians Life Uk
14:28
Earth fault loop impedance testing - ZS
9:32
Residual Electrical
Рет қаралды 16 М.
Installing an earth Rod - New TT Supply
30:36
Residual Electrical
Рет қаралды 47 М.
Earth Electrode Testing
14:16
John Ward
Рет қаралды 501 М.
Earth Continuity Test
5:43
Master Electricians New Zealand
Рет қаралды 42 М.
WORST DIY ELECTRICS I'VE EVER SEEN! 🤯
22:52
Artisan Electrics
Рет қаралды 665 М.
HOW TO PREFORM EARTH RESISTANCE TEST
14:36
rictor rictor
Рет қаралды 250 М.
Maximum Earth fault loop impedance
27:21
JPElectric
Рет қаралды 11 М.
АЗАРТНИК 4 |СЕЗОН 1 Серия
40:47
Inter Production
Рет қаралды 1,1 МЛН