Earth ground testing with Fluke 1625

  Рет қаралды 88,436

ToomsDK

ToomsDK

Күн бұрын

Пікірлер: 25
@ahmedfrag7817
@ahmedfrag7817 3 жыл бұрын
I WOULD LIKE TO THANK YOU SOOOOOO MUCH FOR YOUR VIDEO.
@NichyMateescu
@NichyMateescu 6 ай бұрын
Hi…thank you. Very informative.
@soydelrancho
@soydelrancho 8 жыл бұрын
Great video. Thank you.
@rogerpaul2931
@rogerpaul2931 3 жыл бұрын
Dont know if anyone gives a shit but if you are bored like me atm then you can watch pretty much all of the new movies and series on instaflixxer. I've been watching with my girlfriend lately xD
@guillermotrace4391
@guillermotrace4391 3 жыл бұрын
@Roger Paul definitely, I've been watching on Instaflixxer for years myself :D
@andreimartins4679
@andreimartins4679 6 жыл бұрын
my friend, I did the same procedure and the resistance is giving 0.523 on average, when I use another brand of equipment other than the resistance of something close to 5.2R. is there a function in Fluke that changes the decimal places?
@alexandersuarez6839
@alexandersuarez6839 7 жыл бұрын
Hello, I need to know something. Are the stake of aluminum? or what kind of material?
@ToomsDK
@ToomsDK 7 жыл бұрын
they are not alu, it is some type of hard steel
@loknathsaha5171
@loknathsaha5171 4 жыл бұрын
What is the current flow through electrode?
@ToomsDK
@ToomsDK 4 жыл бұрын
cannot remember it, it was long time ago
@drytkni2313
@drytkni2313 5 жыл бұрын
Usually using only one electrode for grounding gives poor result, using many electrode making loop around the house and connect them together with 16mm copper wire is the proper why to do it, just remember not to close the circle as it can start working as an antenna.
@ToomsDK
@ToomsDK 5 жыл бұрын
I think that depends on what country your in and local law and rules, in Denmark one electrode is often more then good good enough.
@jerrykgamane9671
@jerrykgamane9671 5 жыл бұрын
If the resistance is too high, how many in meters do you put the extra spike apart from the existing one??
@ToomsDK
@ToomsDK 5 жыл бұрын
It dependes, if it is because the old just dont work then you can most likely place the new one nex to it, if it is high resistance to grund at the location then you have to selected a better location
@electronicatutorial
@electronicatutorial 5 жыл бұрын
The easiest way is by increasing the depth of the electrode to double you will decrease the resistance by 40%, by increasing the diameter of the electrode to double you only decrease resistance by only 10%, you can also use special dirt with a solution with bentonite clay around the electrode, that is sold in special electrical stores. Problem with bentonite is that when it is very dry it shrinks therefore creating discontinuity in the contact between the bentonite clay and the surrounding soil and this will increase the resistivity.
@ToomsDK
@ToomsDK 5 жыл бұрын
@@electronicatutorial it is not allowed to use tricks like changing soil or pouring water when testing, based on the Danish rules then you have to add more earth electrodes and / or move it to another location. Please do not use tricks, read and follow the rules as per your country.
@electronicatutorial
@electronicatutorial 5 жыл бұрын
@@ToomsDK No you are confused I was not referring to tricks to make measurements I know some people do that is against the rules. I meant is a chemical treatment of soil is a good way to improve earth electrode resistance when you cannot drive deeper ground rods because of hard underlying rock, for example you leave it around the earth rod permanently. Magnesium sulfate, copper sulfate, and ordinary rock salt are suitable non-corrosive materials and are widely used you can google it.
@muhammadhamadrashid1540
@muhammadhamadrashid1540 7 жыл бұрын
Isn't the resistance supposed to be less than 1 ohms ?
@ToomsDK
@ToomsDK 7 жыл бұрын
here in denmark the rule is that private house installations most be protected by HPFI relay with 30ma trigger and person volt max most be 50v, so 50v / 0,03A = 1666 ohm i the max ohm to ground limit and my test says only 40-50 ohm and that is well below the 1666
@electronicatutorial
@electronicatutorial 7 жыл бұрын
The NFPA and IEEE recommend a ground resistance value of 5 ohms or less while the NEC has stated to “Make sure that system impedance to ground is less than 5 ohms specified in NEC 50.56. In facilities with sensitive equipment it should be 5ohms or less.”
@teodenpenaroya8474
@teodenpenaroya8474 6 жыл бұрын
Indian engineers here in Saudi are all scambags with fake documents,they are fine even if they got scolded in the site by Construction Manager and PMT,what a shame for this people,it’s fine with them even if they got humiliated just for them to learn what a waste.
@mrdungmy
@mrdungmy 4 жыл бұрын
Make a tutorial video with a pliers
@WZDIESEL
@WZDIESEL 7 жыл бұрын
uh. uh. uh.
@purveekhaynkhyrvaa30
@purveekhaynkhyrvaa30 7 жыл бұрын
super
HOW TO PREFORM EARTH RESISTANCE TEST
14:36
rictor rictor
Рет қаралды 261 М.
龟兔赛跑:好可爱的小乌龟#short #angel #clown
01:00
Super Beauty team
Рет қаралды 111 МЛН
Electrical Grounding Explained | Basic Concepts
6:45
RealPars
Рет қаралды 932 М.
Fluke Academy   Fluke Medidor de puesta a tierra 1625   COMP
5:26
Juan Bustillo
Рет қаралды 4 М.
Earth Electrode Testing
14:16
John Ward (jwflame)
Рет қаралды 505 М.
Ground Rod Resistance
2:41
Northwest Lineman College
Рет қаралды 57 М.
What is Ground? Earth Ground/Earthing
9:27
RimstarOrg
Рет қаралды 3,2 МЛН
Megger DET4TCR2 four-terminal earth/ground resistance testers
4:31
San_measurement
Рет қаралды 1 М.
C.A 6117 Resistance and Continuity testing with Dave Savery
5:19
Chauvin Arnoux UK
Рет қаралды 303
龟兔赛跑:好可爱的小乌龟#short #angel #clown
01:00
Super Beauty team
Рет қаралды 111 МЛН