I am building my home in Thailand, realising early on that there is no electrical standard and very little knowledge of Earthing, I decided to use an UFER grounding system. All my rebar is connected together, by welding and thick copper/brass cable joints, then concrete is poured and metal points at 4 corners of each building come out and all the risers and are connected above the floor plane to a common point by copper cables, all dry, sheltered and protected. For anti corrosion I smuggled in a tin of Copperease (can't get that here along with Marmite and PG Tips) as we used to use that on ships' antennae installations, it doesn't wash off or emollify much. I use a Three Terminal Ying Tong Meter as above and thank you for your video as when I got it the bloody thing the destructions were all in Chinese. For the whole installation therefore I use multiple earths for each supply box being the UFER grounds, as the company supply earth isn't available (LN only) and anyway it's just a piece of galvanised metal buried in dry sand. Drinks are on me if you are ever in Hua Hin area.
@andreim8418 жыл бұрын
Thank you for taking the time to make all these great videos and educate the rest of us. Best of luck to you and your family in 2017!!!
@TinG-hz7fm4 жыл бұрын
Great video, though you could have mentioned that the middle electrode (commonly designated as S) is just a high impedance voltage measuring probe, while the outer probes (commonly designated as E (earth) and H(auxiliary)) are used to inject AC current into the soil. Resistance is calculated internally as the voltage measured at the S-probe divided by the current measured internally by the instrument itself.
@tgwallbank8 жыл бұрын
Just to say I really enjoy your videos, the style in which they are presented and that I appreciate the amount of time you must spend in doing these. Thank you.
@56jmack8 жыл бұрын
Another excellent, well explained video.Cheers John.And Happy New Year
@peterjones27616 ай бұрын
Im wondering which direction you would go away from the original earth stake. If i had a new overhead pole put in for my new supply (I'm very out in the sticks) would I be advised to head towards the pole which happens to be in the same direction of an overhead transformer for me and a neighbour on the next farm. The new supply is PME but the estimator guy said to put an earth stake in with a 25mm CPC connection to it. Never had that request before in my youger days of new house etc.
@jwflame6 ай бұрын
Doesn't matter particularly, other than it should not be near any other buried metalwork, cables, pipes or other electrodes. 10 metres distance from anything else at least.
@dreamkiss2 жыл бұрын
I am trying to find the video for the first method of earth testing when power is available, cannot find it ?
@christastic1003 ай бұрын
As always very clearly explained.
@fardellp8 жыл бұрын
Surely the resistance will vary greatly at the same installation depending on the type of soil and for a given soil type, its wetness or dryness. Presumably the test should be done after a (long) dry spell.
@doddsy79920 күн бұрын
You are absolutely correct, I was thought that the minimum depth the electrode could be was 300mm, this is because at this depth the earth is not affected as much by climate conditions and is a much more stable environment.
@alialshammari49853 жыл бұрын
Thank you so much sir for your rich information and simple gorgeous way in explaining the lecture, appreciate your help and effort making the information so simple and approachable, from kuwait ali
@Appregator3 жыл бұрын
Do you have a reference for the easy method on your videos? I can't find the link despite searching. Thanks.
@sshrek19963 жыл бұрын
How to measure the resistance of the grid ? I believe the grid resistance will affect the earth resistance. Please correct me if I'm wrong
@gavinstirling94723 жыл бұрын
How can you test an earth electrode if you can not find it because it's Hiden under a deck or something please ?
@robbiesinyangwe56625 жыл бұрын
Thank you for your time to teach. You make understanding simple. Thank you Sir!
@Андреич-с4н Жыл бұрын
I could not find your video about measuring earth resistance when the main electricity is available, and ask my question here Can one get results using any household electric appliance like, say, Incandescent light bulb, a mulimeter and the old good Ohm's Law? One terminal of the bulb is connected to live, the other to earth and the current is measured. Divide voltage by current and subtruct the bulb's resistance and the result is the earth resistance.
@jwflame Жыл бұрын
In theory that could work. In reality you do NOT want to be attempting that, as doing so will put a significant voltage onto the electrode and anything else connected to it which could be dangerous. Would also need a circuit with no RCD on it, otherwise it would trip immediately. Other videos are here: kzbin.info/www/bejne/lXPOf2uch7GMjtk kzbin.info/www/bejne/gWGzZqp9iM-rgqc all others can be searched from the main channel page.
@Андреич-с4н Жыл бұрын
@@jwflame Thank you for answering. If I got you correctly, this method will give sufficiently valid result, yet it is not safe. I still cannot understand the danger. Significant voltage is the same 240 (in my place it is 220) - and this is a voltage we handle habitually with common sense. I am going to use an electric plug and a lamp socket. Connect the live pole of the plug to one lamp socket terminal (the other plug pole unused). The other lamp pole terminal connect to the earth. Of course making all these connections while the main switch is off. RCD is already there
@nilusahio37867 жыл бұрын
why resistance decreases by increasing the distance between the two rod?
@firasalam12 жыл бұрын
Thanks A lot John! very clear and the explanation is straight to the point !
@Teenagegoogoomuk7 жыл бұрын
Damn!! here in the US we have to use 10 foot (3m) rods and achieve 3 to 6 ohms of resistance. I've also had to use 1/4" x 12" X 12" copper plate or ufer grounds for the hard to get places.
@energiavadasz33285 жыл бұрын
Because of the 110V mains
@tablatronix2 жыл бұрын
So how do you do this without special testers? Seems like you could
@adelachacha258211 ай бұрын
so if we have well of earth 40m and electrode of 3m distance of t1 400 m
@i-will-get-you-there8 жыл бұрын
Thanks for the vid... Have a good new year! Cheers
@Motorman21128 жыл бұрын
Thanks John. You mentioned that you might be doing these tests while it is raining. Is it necessary to repeat the test when the ground is drier to ensure that the resistance will still be low enough during hot periods with little rain, or does it not change much?
@rrrrrrrrrrrrrrrrrr09 ай бұрын
Ideally you want to do it when the conditions are least favourable, say a hot dry day
@aussie81143 ай бұрын
What about if it’s not a sunny day 🌞
@CaptainK0075 жыл бұрын
(Newbie) So what’s the score on wet ground? If you do the tests/install in a soggy February and you get good reading and we have a very dry summer and the ground drys out. Cheers enjoy the vids.
@ajvantonder70553 жыл бұрын
Hey John hope you can help me with the question it reads: A maximum earth resistance of 300 Ω, shall be maintained between electric fence earth electrodes. Do I connect the leads to both electrodes +- 30meters away. Or do I insert the small electrodes into the ground as shown on your video the electrodes are 1.2meter long.
@MD0MDI6 жыл бұрын
Very useful, thanks very much for also adding the what if section, really helpful.
@amroshareef1006 жыл бұрын
Dear Sir I'm working on an existing hospital over 30 yrs old, and i found only lightening pits connected to the lightening grid on roof, how should I test the earthing system and is it possible for the designer to used the concrete grid instead of the earthing electrode ?
@christiandogbe85462 жыл бұрын
This is deeper knowledge. We greatful
@user_i.d5 жыл бұрын
If u use a earth grid or earth tape how far do they need to be in the earth?
@crigeorge95496 жыл бұрын
good explanation John.
@ninav745 жыл бұрын
What's the purpose of moving the earth spikes please?
@JEFF-Elliott2 жыл бұрын
Hi this is great because it gives me ideas of how to achieve my goal, but I would like to know more about the meter you’re using I have been told I need to use a mega but this looks like something else you have but you did not mention what it was. I use Radio and I need to know I have a resistance of less than 10 ohms. This sends current, and I am afraid to test as I may damage my equipment. 🤔. This demonstration 👍 just need to know more.
@ibrahimwahb26077 жыл бұрын
How we could test it if the main power available ?
@ooltimu5 жыл бұрын
Wet your fingers and touch the mains cables
@bhupendrosalam60375 жыл бұрын
Some people ,knowingly or unknowingly, put common salt ,charcoal inside the pit(dug for the purpose), before putting a GI pipe (though costly). Will the salt help significantly or is it only a precaution?
@jwflame5 жыл бұрын
It will reduce the impedance, but it will also increase corrosion so is not recommended.
@Tanmay_Bhattacharya17 жыл бұрын
Need more details regarding how exactly this mechanism works
@TanveerKhan-bk7sq4 жыл бұрын
What shall be the earth electrode resistance
@jwflame4 жыл бұрын
Depends on the circumstances and the installation, but generally less than 200 ohms is required, and lower is better.
@sbusweb7 жыл бұрын
When doing the 'rod test', all very well testing your own electrode, but what about the impedance of the earth-electrode at the source transformer, how do you test that // what standards is 'their' elecrode rated/checked to?
@jwflame7 жыл бұрын
It should be less than 21 ohms, usually a lot less. The earth electrode at the transformer is usually a large metal grid buried in the ground, not a single rod.
@ianlouden79395 жыл бұрын
DNO's sometimes spend more money getting a low enough earth impedance at the substation than the cost of the substation, TN-C-S is therefore more or less guaranteed to be good!
@AngDavies3 жыл бұрын
Test again with mains, and compare the two?, Line conductor impedance should add rather little to the loop
@davidnorthcott92296 жыл бұрын
Fantastic video. Thanks for making it look easy to understand
@valyardelean5 жыл бұрын
What do you do when you have the earth rod to test surrounded by concrete slab, where do you put the test probes with the spikes? Thanks for the vid 🤗
@jwflame5 жыл бұрын
If it's all concrete then you can't- however other test methods are available.
@valyardelean5 жыл бұрын
@@jwflame I was thinking to try a Ze test.
@yousefghareeb82878 жыл бұрын
Dear Mr.John , I have to test the earthing for 40 connected electrodes (earthing network ) . Please tell me if I can use 62 % way , and please tell me if i have to isolate the electrode from the earhting network during this test ? Best Regards,
@jwflame8 жыл бұрын
You can test the electrodes together, but they must be disconnected from the electrical installation when testing.
@jenko7018 жыл бұрын
I like your videos because I like to see the differences from here in the US . We should all use the term earthing like you guys do . We just say grounding wire and some times there is confusion between it and the neutral , and as you know we split our 240 to 120 circuts so a neutral go with every 120 circut. This was deliberately set up by Elihu Thomson for safety?
@mongaabraham6743 жыл бұрын
Nice course i appretiate it good explaination but thats not enough for me you suppose to talk about the soil type as well and the great ground résistance value for in low voltage and Médium voltage
@Ricky-zj6sy3 жыл бұрын
I find it always best to use a 17th or 18th edition multi function tester to measure the Ra or earth fault loop impedance for the means of earthing. The three spike testers will not measure the critical loop to ensure automatic operation of the RCD's. They can be misunderstood and also show incorrect readings from the short temporary spikes into dryer topsoil rather than deep clay, Two wire testers will measure the entire earth fault path from the transformer through the line conductor, down the spike to the ground, and across the ground and back to the high voltage earth at the TX. this needs to be below 200 ohms and is the best method by far. You also need to ensure that you disconnect the earthing conductor and test only the means of earthing (NOT parallel paths to heating systems and water mains etc.) You MUST also ensure that this test is done with ALL current using equipment turned off at the main switch to ensure nobody can become injured while the earth has been disconnected.
@Ricky-zj6sy2 жыл бұрын
@David Morris Exactly David, that three wire test method is a nonsense and only tests the ground between the three electrodes used and not the critical Ze (Ra) measurement. Don’t waste your time attempting it mate.
@henryvergara33035 жыл бұрын
Thank you for this video sir.it's my first time working in earthing and im looking for some info.and im found yours.thanks.
@wayneisinwater8 жыл бұрын
hey john! great video. i realyl like the quality of your videos. what kind of camera do you use?
@ΣπύροςΚουνέλης-μ1κ5 жыл бұрын
where can I find the previous video or how is its filename so that I can watch it ?
@jwflame5 жыл бұрын
All videos here, arranged by topic: kzbin.infoplaylists?shelf_id=0&view=1&sort=dd
@sbkentertainmentknowledge42136 жыл бұрын
Well, Can you Clarify my few doubts Sir. 1. What is the reason behind puting the 10 time of Depth of Earth road. If not maintained what will happen
@valyardelean5 жыл бұрын
Than it's in the same area ...
@MrDumbdane8 жыл бұрын
Here in denmark, we rely on rcd's for protection. They are in fact required by law to be installed in all consumer units. Therefore, the earth electrode needs to fit the rcd. As 50 volts is max alowed for humans to touch and most rcd's trip at 0,03 amps, the max resistans for the earthrod is 50/0,03 = 1666 ohms. Some equipment require 0,1 or 0,3 amp rcd's so 500 and 166 ohms. Could you please explain why you say 100 ohms for TT in england? And thank you for all the videos you do, I realy enjoy watching them. As others has said before, you can explain things so everyone can understand them. Keep them comming 🙂
@Jamal_Tyrone6 жыл бұрын
According to the On-Site Guide (BS 7671) it's between 21 and 200 ohms on a TT Earthing System. Obviously the closer you get to 21 ohms the better.
@bobuk57226 жыл бұрын
Calculation is misguided. There's a potential divider effect. Faulty low rsistance load connected to high resistance earth rod gives a high voltage on the supposed 'earth' wire.
@jeffclement94485 жыл бұрын
Thank you for your video. Very informative and helpful.
@gratitudeacademy89666 жыл бұрын
Correct me if possible, but i thought the ideal Earth test resistance should be less than 1 Ohm?
@jwflame6 жыл бұрын
Less than 1 ohm on TN systems where the earth is provided from a cable. With an earth electrode (TT), resistance will be much higher as it depends on the resistance of the electrode to the surrounding soil, which is typically many 10s of ohms.
@jamesgrimwood12858 жыл бұрын
9:00 - Words spoken by someone who's obviously done this themselves ;-)
@Pentti_Hilkuri8 жыл бұрын
What madman dislikes earth electrode testing???
@MartiA19736 жыл бұрын
Pass the hi Vis vest and boots. We playing in the mud! Another classic JW crystal clear explanation
@ebaystars3 жыл бұрын
All Thai "electricians" who are also "car mechanics", "builders" "architects" "pilots" etc etc
@ryanelliott16503 жыл бұрын
The type that wants to be an earth electrode
@Michelle-jc7dj3 жыл бұрын
Really informative videos. Be great to have one on hot tub installations as there's a lot of conflicting information around interpretation of BS7671 special locations, PME, TT systems etc. I'm sure you could guide people through the correct best practice, and I for one would appreciate some expert clarification.
@danieleuboldi9967 жыл бұрын
Hi John, do you any video showing the use of method 1, i.e. mains?
@jwflame7 жыл бұрын
Not yet. Hopefully will do videos showing all of the various tests, but it is rather difficult to find somewhere that it's possible to show the tests, and get permission of the building owner. Making a video while doing them means it will take several times longer, so a few hours of tests could end up taking a couple of days - most people don't want that.
@mwemamutua1914 жыл бұрын
Hi John do you have video showing testing when mains available ? Or can u explain in writing ?
@arqamsaeed12285 жыл бұрын
You done a great job thank you so much. Very useful for me.
@Bharatmatakijai1112.....5 жыл бұрын
What is the angle between other two electrodes
@gntviix5824 жыл бұрын
I think it has to be in the same line
@jenko7018 жыл бұрын
I like your videos and for any one that likes the history of this topic a great person to look up is Elihu Thomson.
@jamblob32084 жыл бұрын
I am unclear why the electrodes need to be far apart yet tape or a grid or a pipe are considered the same thing. They are not only Not Far Apart but continuous?
@AngDavies3 жыл бұрын
Given two electrodes, spacing them apart gives more 'bang for the buck' than putting them close together, tape/grid would just overwhelm that with shear area. I.e. where two electrodes far apart might have half the resistance, close together would have more than half
@michaelagnew78254 жыл бұрын
good vid, but slightly confused, putting aside the 10:1 rule surely connecting multiple rods to a soil with poor conductivity even if they are inches apart will gain more surface area, hence better figures. Im guessing that surface area plays a big role here
@jwflame4 жыл бұрын
Surface area is the main factor, so more is certainly better. Multiple rods close together will be better than a single rod, but spacing them apart is better still - and as the effort of installation is the same regardless of where they are located, they may as well be spaced apart.
@michaelagnew78254 жыл бұрын
@@jwflame thanks JW, its an awkward question I know!
@michaelagnew78254 жыл бұрын
@@jwflame I guess that if theres no option due to area restriction and crappy soil condition, planting them very close and bonding together is the second best thing as we dont want voltage potential
@habiblee2603 Жыл бұрын
I have concrete ground 😢
@bobhatcher55058 жыл бұрын
Very informative, thanks!
@jsanti725_Offl7 жыл бұрын
thanks a lot for your recommendation and knowledge
@ajithkumaraha4 жыл бұрын
Great video very helpful
@ekawakakonahi11746 жыл бұрын
What do you do for earthing the elctrode if you live on a old lava field and have no soil besides solid lava rock?
@DerekkMurray8 жыл бұрын
I used to do this with a variation of a whetstone bridge
@Chimp_No_17 жыл бұрын
Wonderful.. So helpful, thanks John
@ianlouden79395 жыл бұрын
It should be noted TT earth impedance can easily double from wet months to dry months throughout the year, I guess that why
@propertyomgtv2546 жыл бұрын
Dear sir, is the type of material of the electrode important and affecting the readings significantly?
@jwflame6 жыл бұрын
No, as long as it is conductive. The main thing affecting resistance/impedance is the contact between the electrode and the surrounding soil. Longer rods or larger diameter rods will improve this as there is more surface area.
@propertyomgtv2546 жыл бұрын
John Ward Dear Sir, many thanks for your kind reply. I was considering the options of electrode, as the high copper content composition one costs 4x more than the generic ones. Thank you. And i love your channel!
@benharris22178 жыл бұрын
is there not a risk of striking a buried cable or pipe when driving these electrodes in?
@jwflame8 жыл бұрын
Yes, so a proper survey is essential before installing one.
@geoffmatthias39926 жыл бұрын
Ben Harris Oh yes there is a friend of mine who is a spark was driving a spike in and hit a Gas pipe ? Gas company had to dig up a drive needless to say the owner was none to happy?
@fireblazer66617 жыл бұрын
Question: Can a person who has ZERO ground in a house, ground just ONE power outlet in the house by running a ground wire from the ground terminal out into a grounded stake in the ground? My house has old screw in fuses, and absolutely no ground wire anywhere. There's no plumbing or anything in the house to use for a ground either. I run a compost toilet/outhouse, and haul water there. I want to avoid the risk of frying my electronics but I cannot afford a full electrical update. It's 10,000-12,000 to do this (almost as much as I PAID for the house!!)... I won't be able to afford it for YEARS best case. SO what I want to do, is somehow protect my electronics by at least grounding ONE outlet cheaply. Is this possible? AND NO, I DO NOT HAVE INSURANCE, so I don't care if things are certified insurable, just so long as my gear is safe.
@pedrosegoviavarela384710 ай бұрын
Quiero que se explique en español por favor..
@gntviix5824 жыл бұрын
For real , thank you sir
@williammacrae61195 жыл бұрын
Wrong middle lead is 62% of long leads distance
@mdrashidarafat80196 жыл бұрын
After getting resistance of electrode , how to get soil resistivity
@MD0MDI6 жыл бұрын
Is this what is called 'Ra' testing?
@jwflame6 жыл бұрын
Yes, Rₐ is the resistance of the earth electrode and the conductor connected to it.
@MD0MDI6 жыл бұрын
John Ward thanks John, having a nightmare trying to get a suitable Earth, presently cannot get below 1.8k with three earth rods, now going to try tape on Monday once Yesss opens up..
@jenko7018 жыл бұрын
Did I hear you right , earthing electrodes are not required on new installations .
@jwflame8 жыл бұрын
Yes, but only because new installations are very unlikely to be TT. If a new install is TT, then an electrode is required.
@computeraddic6758 жыл бұрын
What is TT?But in the Netherlands,every dwelling,every family home,every housing flat has to have its own earth pin!If the Housing flat is long even more than one!It amazes me to hear this is not required in the UK for new installations.
@benharris22178 жыл бұрын
Computer Addic We usually use the suppliers earth. the most common earthing method in the UK is known as TN-CS. essentially all line to earth fault are converted into line neutral faults. The earth electrode (or earth pin as you call it) is generally only used in rural areas.
@computeraddic6758 жыл бұрын
So the resistance to earth is higher than in the Netherlands.We think 10 ohms is a lot!
@jwflame8 жыл бұрын
TT is where the only earth connection is via the electrode, the electricity supplier does not provide any earth connection from their cable. Most supplies in the UK have the earth connection provided as part of the supplier's cable and a separate electrode is not required.
@asadbaig92762 жыл бұрын
That sun looking cool
@MDMAx7 жыл бұрын
Thank you so much!
@linossinkala78402 жыл бұрын
Thankyou sir
@rajnishsaharawat32564 жыл бұрын
thanks a lot sir
@rossaindow43907 жыл бұрын
Why do we do this test ?
@jwflame7 жыл бұрын
To ensure the impedance is low enough to trip the protective device (an RCD usually) when a fault occurs. If it was too high, a fault between line and earth in the installation would result in exposed metalwork becoming live, and the power would not be disconnected.
@rossaindow43907 жыл бұрын
Thanks a lot great explanation
@MrOckhamsRazor6 жыл бұрын
He's wearing a Stewie T-Shirt. This is commendable !
@rokutime2627 Жыл бұрын
229 dislikes. Arrest former CEO Susan for protecting corporations.
@electrisienali45847 жыл бұрын
كيفيت حساب
@soewin97842 жыл бұрын
Good.
@akinolaoluwabusuyiezekiel33064 жыл бұрын
Thsnks
@edmundfisher49518 жыл бұрын
Somebody is awake early!
@amerriaz108 жыл бұрын
so you do not want anyone else to learn
@humaali78815 жыл бұрын
V nice sir good explain
@ibrahimabdullah44306 жыл бұрын
Stewie Griffin 😂 1st thing I noticed when video started. Thanks for sharing another great video. 👍
@dengakairup3 ай бұрын
Today our sun 🌞 very nice
@ragubathi18615 жыл бұрын
Super
@Zilvinas0214 жыл бұрын
Save the environment by writing on both sides of the paper or use a tablet!
@josephsagoe55197 жыл бұрын
Good
@pedrosegoviavarela384710 ай бұрын
I like and Englihs and spanish type bilingue okey...!
@singh-ov2qi6 жыл бұрын
in hindi
@toma97486 жыл бұрын
Stewie!
@AshokKumar-ij8rc6 жыл бұрын
ka hindi ma na bol sakte hai Na ki
@hiei35164 жыл бұрын
bare mumble
@natepeterson346 жыл бұрын
Horrid explanation JW! This is the worst training on earth electrode testing that I’ve possibly ever seen! If you don’t know what you’re talking about, why would you sit there and muddle your way through it and tell people some stupid stories!