EEVblog 1507 - Mida: A surprisingly good cheap portable Electric Car EVSE Charger

  Рет қаралды 112,110

EEVblog

EEVblog

Күн бұрын

Teardown of the cheapest portable electric car charger EVSE available in Australia, the 15A Mida Type 2 portable electric car charger.
s.click.aliexp...
Zappi solar EV charger: • EEVblog 1437 - Zappi 7...
Forum: www.eevblog.co...
Support the EEVblog on:
Patreon: / eevblog
Odysee: odysee.com/@ee...
Web Site: www.eevblog.com
EEVblog2: / eevblog2
EEVdiscover: / eevdiscover
AliExpress Affiliate: s.click.aliexpr...
Buy anything through that link and Dave gets a commission at no cost to you.
Donate With Bitcoin & Other Crypto Currencies!
www.eevblog.co...
T-Shirts: teespring.com/s...
#ElectronicsCreators #EVSE #ElectricCar

Пікірлер: 241
@midaevpower
@midaevpower Жыл бұрын
Thank you for your recognition and evaluation of our products
@AdamBakerBaker
@AdamBakerBaker 2 жыл бұрын
I do love it when you say "yankee bucks"...
@DrTune
@DrTune 2 жыл бұрын
As a person who works on these; with big 50+A relays the coil thermal dissipation is substantial. We definitely pay attention to the latching vs holding current and do stuff like adaptively PWM the coil after contact. PCB trace dissipation also all adds up, we have a lot of thermistors. Also; things like UL safety tests for these can be a bit of a PITA...
@Miata822
@Miata822 2 жыл бұрын
Uncommon these days to see a consumer electronics teardown that isn't shoddy or downright dangerous. Good on Mida.
@stevenbliss989
@stevenbliss989 2 жыл бұрын
I agree, rare these days, but it is crazy over engineered though!
@mikeselectricstuff
@mikeselectricstuff 2 жыл бұрын
Latching relays are really common in these - it's about coil heating. You'll probably find it unlatches immediately on power-up. I think I've seen one with a big cap that unlatches on powerdown
@EEVblog
@EEVblog 2 жыл бұрын
Yep, mentioned both those things in the video. Coil power in this case is 1.5W per relay. Not good in a sealed enclosure like that.
@mikeselectricstuff
@mikeselectricstuff 2 жыл бұрын
Latching probably also gets more contact pressure, may need a bigger coil for non latching
@EEVblog
@EEVblog 2 жыл бұрын
That would be interesting to try and get data on.
@GodmanchesterGoblin
@GodmanchesterGoblin 2 жыл бұрын
Also the case that latching relays, if designed appropriately, can be driven into a disconnecting state rather than just relying on spring tension.
@BlackXeno
@BlackXeno 2 жыл бұрын
Common with Chinese e-bike chargers!
@ingolfmuller566
@ingolfmuller566 2 жыл бұрын
I learned, to leave the ground wires always a bit longer, in case of a damaging pull at those cables, the 'hot' cables will disconnect first.
@jwardell
@jwardell 2 жыл бұрын
I have a 32A version (identical on the inside and outside, another brand, again cheapest on Amazon) and it has been charging my car wonderfully for 6 months. Love the extra display
@mikeselectricstuff
@mikeselectricstuff 2 жыл бұрын
EVSEs that ignore the diode are surprisingly common - the standards do require diode checking, but I tested one that had been tested by TUV that didn't. Strange as it's not hard to do.
@EEVblog
@EEVblog 2 жыл бұрын
I wasn't sure if the standards required it. I wonder if the genuine Hyundai one does it.
@Sparky400
@Sparky400 2 жыл бұрын
​@@EEVblog a major company with an expensive product cheap out on a part or not folow a standard? never *cough* porsche built in charger *cough*
@sarowie
@sarowie 2 жыл бұрын
@@Sparky400 well, Porsche is part of VW and VW internal combustion engines are famously not build for for German weather and need protection from those extrem lows from fall/winter/spring and highs in summer. Meanwhile Porsche internal combustion engines inject extra fuel into the engine on german Autobahns, because, well: it helps cool the engine and its not prohibited as those speeds are outside of the regulatory frame work.
@emmettturner9452
@emmettturner9452 2 жыл бұрын
As for the thermistor: Believe it or not, they more often insist on it more for use with low amperage outlets which might not be able to safely handle sustained loads from vehicle charging. They can get hot and melt. This was contrary to your speculation so I thought I’d mention it. I have a real-world example, if you are interested: I have two EVSEs with the exact same ClipperCreek Gen2 EVSE board inside, one running GM’s firmware with a NEMA 5-15P 120v plug and a 12A limit (bundled with the Chevy Volt/Bolt) and the other running ClipperCreek’s firmware with a NEMA 14-30P 240v plug and a 16A limit (sold as “AmazingE” brand). Only the GM firmware with the 5-15 plug has the thermistor… and it won’t work without it unless you use a resistor to bypass. I know because I found the populated PCB for $30 as a new GM spare and used it to build another EVSE, so I really have three with the same board. ;) The AmazingE unit does not have/require the thermistor/resistor because they expect a NEMA 14-30R to easily handle 16A without getting hot. A NEMA 5-15R, on the other hand, is often worn out and gets hot. Though his Volt would default to 8A on 120v my brother would routinely override and set it to the theoretical safe limit of 12A until the outlet in his garage melted. After that we converted his GM unit to 240v and gave it a NEMA 14-XX plug (no neutral to fit more receptacles).
@wtmayhew
@wtmayhew 2 жыл бұрын
I know the GM/Clipper Creek EVSE supplied with the Volt/Bolt will safely operate from 240 volt 8 or 12 amp single phase using a pigtail adapter. Is there something more you did internally beyond changing the plug, as I notice you said you converted your brother’s GM EVSE?
@dglcomputers1498
@dglcomputers1498 2 жыл бұрын
The UK/Type G ones have to have a thermistor in the plug as I understand, a UK plug can get quite warm even at 10A so some overheating protection is needed. On a forum an ex-GPO bloke said that they would only rate 13A type G sockets at 10A and that was only with MK plugs and sockets, any other combination and it was more like 8A I believe.
@emmettturner9452
@emmettturner9452 2 жыл бұрын
@@wtmayhew My reply got ghosted. :( The CC Gen2-based GM unit works great with an adapter but you can’t chop and completely replace the plug without bypassing the thermistor. Ai4px posted the specs for a replacement thermistor or resistor bypass on ChevyBolt. Small world since I already knew him from Ninjette. :) I had to replace the thermistor with ai4px’s resistor bypass with my GM spare board since it never had one and refused to run without it.
@wtmayhew
@wtmayhew 2 жыл бұрын
@@emmettturner9452 Thnaks very much for your reply. Duly noted.
@wtmayhew
@wtmayhew 2 жыл бұрын
@@emmettturner9452 Thanks for the information, much appreciated.
@PeaceChanel
@PeaceChanel Жыл бұрын
Thank You for All that you are doing for our Planet Earth.... Peace.. Shalom.. Salam.. Namaste 🙏🏻 😊 🌈 ✌ ☮ ❤
@1kreature
@1kreature 2 жыл бұрын
The NTC is for the input cable so it can monitor the connector temperature. Not sure where it is mandatory but some places it is. Especially if passing the 10 amp limit on a schuko.
@DeKempster
@DeKempster 2 жыл бұрын
Would like to see the earth wire longer than L/N. If the cable would be janked out the earth would disconnect last
@Sparky400
@Sparky400 2 жыл бұрын
even if they left the PCB as is and just made it with a bit of extra slack.
@pnjunction5689
@pnjunction5689 2 жыл бұрын
Nice! I like the curvy PCB traces. Somebody had fun 🙂
@andrew2004sydney
@andrew2004sydney 2 жыл бұрын
In 2000, Australia converted to 230 V as the nominal standard with a tolerance of +10%/−6%
@6toeNL
@6toeNL 2 жыл бұрын
and before? 110?
@ChungshanStory
@ChungshanStory 2 жыл бұрын
@@6toeNL 240V ±6%
@kataraluna8417
@kataraluna8417 2 жыл бұрын
They should also attach the ground together with a wire instead of just the board. If the board breaks it has no more ground connection. (even if its hard to break, it can happen.)
@romanmaier4307
@romanmaier4307 2 жыл бұрын
Shouldn't be a problem with a plastic housing. And ive you break your board, youve got other - bigger - problems... especially youve got an rcd in your house.
@marvingudel605
@marvingudel605 2 жыл бұрын
Hope the price doesn't go through the roof after this review, I'd definitively get one of these if I ever need one ;) Also the rounded traces on the bottom are a real joy to look at.
@chr155h4w
@chr155h4w Жыл бұрын
Thanks for the really comprehensive review. The dip switches do set current and region, anything from locking in at a specific current to 1-40amp selectable at 1amp spacing! I've upgraded my unit from standard UK 13a plug to 16a commando plug, then adjusted the dip switches and got 16a option enabled. I've got a badly handwritten table of which switches do what if anyone needs it.
@Ritari2000
@Ritari2000 9 ай бұрын
Also bought this charger. I would appreciate if you write the table here
@hyperfluff_folf
@hyperfluff_folf 2 жыл бұрын
as for the additional connectors inside by what i would conclude this is likely just an alternative way to install the board in a different enclosure where you may not directly screw on the wires but instead put them in such a connector, maybe the board is used in other products too
@SkaBob
@SkaBob 2 жыл бұрын
Good to see easily replaceable power cables on both ends.
@randycarter2001
@randycarter2001 2 жыл бұрын
The best description of an EVSE is a smart safety switch. It only allows power to flow when all of the safety criteria has been satisfied.
@mikeselectricstuff
@mikeselectricstuff 2 жыл бұрын
Surprising that they have the metering stuff in there, and the load current sensing - no need at all for these in a low-cost EVSE and some significant cost savings possible without impacting functionality or safety. Also the display for that matter...
@EEVblog
@EEVblog 2 жыл бұрын
Yeah, at this price point I expected to just see basic current limiting.
@edc1569
@edc1569 2 жыл бұрын
@@EEVblog Why, can you not trust the car to pull what its told to?
@EEVblog
@EEVblog 2 жыл бұрын
@@edc1569 Yes, by "basic current limiting" I mean the PWM signal to control the car to do the current limiting, and maybe some gross overload limiting protection perhaps.
2 жыл бұрын
You have to me much more conservative in limiting the current if you are only checking the peak or average.
@travcollier
@travcollier 2 жыл бұрын
@@edc1569 Because you don't want a single point of failure to burn down your house ;)
@travcollier
@travcollier 2 жыл бұрын
I love these teardowns. Cheap Chinese equipment these days can be quite good quality, but can also be absolutely crap. Nice to see the examples of manufacturers over there upping their game. Nerds taking some pride in their work
@glenmartin2437
@glenmartin2437 2 жыл бұрын
Thank you. Good video and enjoyed the comments.
2 жыл бұрын
The reason for that power monitoring chip is that you have to limit RMS current and it's really hard to measure RMS current if current is not sinusoidal, which you bet it isn't, particularly when you are driving the car charger at very low load factors, down to 1kW for a 22kW charger.
@sarowie
@sarowie 2 жыл бұрын
I wonder how the accuracy of the current limit has to be on the lower load factors.
@andrelange9877
@andrelange9877 2 жыл бұрын
How does it accomplish current limiting? It has only a couple of relays so you mean shutting down the load likeusing fancy electronics to emulate a circuit breaker?
@JasperJanssen
@JasperJanssen 2 жыл бұрын
@@andrelange9877 yeah. It tells the car it’s allowed to draw n kW, and if the car fails to honor that, it fucked around, time for it to find out.
@tx5brent
@tx5brent 2 жыл бұрын
As an Aussie who has 15A equipment in my garage, I know exactly why you may want to limit the current to 10A......
@hannahranga
@hannahranga 2 жыл бұрын
One could easily have the assumption the only difference between a 10A/15A plug is a rough brass edge on the earth pin.
@tx5brent
@tx5brent 2 жыл бұрын
@@hannahranga hahahaha yeah, too bad KZbin doesn't let me post photos...
@Sparky400
@Sparky400 2 жыл бұрын
is there a story behind this?
@tx5brent
@tx5brent 2 жыл бұрын
@@Sparky400 you can easily file down the earth pin on a 15a plug to fit in a 10a socket. Our outlets are designed such that you can plug the lower rated plug into a higher rated socket, but not the other way around. A 10a plug will fit into a 10, 15, 20, 25 and 32 amp socket, but a 25a plug will only fit into a 25a or 32a socket (unless you have a file....)
@MrThomashorst
@MrThomashorst 2 жыл бұрын
And as a German who has a 16A outlet in my garage, I can tell you there is a huge difference of using 16 amps for a few minutes and charging an ev over night 😱
@looksharpPT
@looksharpPT 2 жыл бұрын
I Dave, I have one just like that. Working fine since May/June 2021. At the time, it cost me about: 90~100€ (delivered).
@hermannschaefer4777
@hermannschaefer4777 2 жыл бұрын
Also available in Europe, as modell MIDA-EVSE-PE16S with a higher current rating: 8A 10A 13A 16Amp. I wonder if there are any differences, I guess: no. ^^
@KeritechElectronics
@KeritechElectronics 2 жыл бұрын
Fine build quality indeed, interesting relays and oh my, just look at those curvy traces! Old style PCB design, thing of beauty, joy for ever. Wonder if it was designed in modern Kicad. It's good to see an integrated RCD here, very smart to have it if your house's wiring doesn't have one and you get a breakdown between the primary and secondary side in the car's converter. Cool EV simulation circuit :) BTW the larger ground contact on a plug is pretty sensible, allows a lower current rated plug in a larger current socket but not the other way around, making it impossible to connect heavy loads to the wiring that can't handle them... Unfortunately this doesn't prevent the "wise guys" from circumventing this safety measure by cutting the ground prong off.
@EEVblog
@EEVblog 2 жыл бұрын
I believe the RCD is part of the standard.
@KeritechElectronics
@KeritechElectronics 2 жыл бұрын
@@EEVblog standard for wiring and standard for EVSEs, I guess. And any devices meant for outside use, like outdoor vending machines, water pumps etc.
@Broken_Yugo
@Broken_Yugo 2 жыл бұрын
Re cutting the ground pin off, I'm reminded of the one and only NEMA 5-20P (20 amp plug for 20 amp north American outlets) I've ever seen in the wild. It was a molded factory plug on a pressure washer and someone had twisted the pin with pliers so it'd fit in a 15 amp outlet.
@hannahranga
@hannahranga 2 жыл бұрын
@@KeritechElectronics not as needed for other equipment in aus as almost all gpo's are RCD protected these days (it's required to sell/rent). Makes more sense for a evse as hopefully it's a type B RCD in case of any DC earth faults
@KeritechElectronics
@KeritechElectronics 2 жыл бұрын
@@Broken_Yugo inconsiderate or plainly stupid people have been, are and will be all over the place. If you try to make something idiotproof, the world will always come up with a better idiot.
@TheEmbeddedHobbyist
@TheEmbeddedHobbyist 2 жыл бұрын
Nice to see the you turn it around to match normal circuit flow convention of left to right. everyone knows electrons don't like to flow right to left on paper 🙂
@moestrei
@moestrei 2 жыл бұрын
Those relays can go into one on one off when there is a power failure. My unit needed me to manually switch both off to recover. I also have a Khons 22kW adapter, pretty bullet proof and a gen2 Tesla HPWC which has an ABB 64A contactor and is converted to charge from an 12kWp off grid solar (charge rate according to solar input).
@fiddlerJohn
@fiddlerJohn 2 жыл бұрын
Thanks for the tip!
@kilwo
@kilwo 2 жыл бұрын
It’s 1m waterproof, but the cable to the plug didn’t look like a meter long!
@randycarter2001
@randycarter2001 2 жыл бұрын
Since the hold current is much less than the toggle current you can cut relay power by over 75% by reducing the voltage.
@edc1569
@edc1569 2 жыл бұрын
In the UK most electricians will tell you these are only for emergencies as PEN faults (when the neutral in the street drops so neutral comes live, and so does earth) just want to kill you at any moment. The same electricians will go lash up a load of class I outdoor lighting in the flower beds of your garden where the kids play. Its a huge money spinner installing fixed charge points at the moment here, part of the sales pitch is scaring people off of using portable EVSE's and weirdly (or not) the NICIEC and IET are behind it.
@glynjones8187
@glynjones8187 2 жыл бұрын
It's not just the risk of the PEN failing and making the cpc live on the supply side. It's the DC being passed back from the vehicle to the supply side and having no were to go as most common AC, A and F type RCDs can't see a smooth DC current under 10mA. So a 800v DC current from a modern battery in a failed TN-C-S (PEN) system would be fatal on contact with any extraneous conductor within the Equipotential zone eg any metal or class 1 piece of equipment within the property.
@JasperJanssen
@JasperJanssen 2 жыл бұрын
You can see this guy has both a current sensor and an RCD built in - presumably it’s an A-class or better RCD.
@OneBiOzZ
@OneBiOzZ 2 жыл бұрын
The only complaint i have is i would like to see some plastic over those input terminals so that ribbon cable does not rub over those screws
@EEVblog
@EEVblog 2 жыл бұрын
Yep, agreed.
@HwAoRrDk
@HwAoRrDk 2 жыл бұрын
I hope those white wires going to the front panel board have a suitably high insulation voltage rating, given that it looks like they'll be folded up against the mains screw terminals when the thing is closed up. :) Also not sure about the fact the earths are linked only by PCB trace. Looks like, what, 5mm wide trace? On 1oz copper? Might just be able to handle 15A without burning itself. But then if there's any significant earth current, it'll shut itself off anyway, right? So probably not an issue.
@mikeselectricstuff
@mikeselectricstuff 2 жыл бұрын
I was thinking the same - there is no need for the earth to pass through the PCB, they could have run a longer wire and screwed into the same post as the output terminal
@EEVblog
@EEVblog 2 жыл бұрын
Yeah, direct earth avoiding the PCB would be better. But ultimately it's got an RCD internally on the mains side, and also you'd have an RCD and fuse in your breaker box as well.
@chasingcapsaicin
@chasingcapsaicin 2 жыл бұрын
@@EEVblog Not here with two Edison 30A fuses to the single phase 220 dryer outlet using loose conduit for ground. yehee, grandfathered
@fabianfeilcke7220
@fabianfeilcke7220 2 жыл бұрын
If you have a earth leakage, it switches off within a few milliseconds, so the trace does not have carry 15A for any significant time.
@hannahranga
@hannahranga 2 жыл бұрын
@@chasingcapsaicin one the things Aus does is require RCD's to be fitted in order to sell or rent a property. Tends to help prevent ancient unsafe electrical installations (not that fuses themselves are unsafe, just the lack of RCD's and likely poor condition of the older cable)
@restfulplace3273
@restfulplace3273 7 ай бұрын
I recently bought a 8A/19A/13A/16A version of this for AU$130 delivered. Stuff is getting cheap. I’m seeing 7kW versions with wifi, Bluetooth. Hoping to see integrations with common solar inverters to use only excess solar. Thanks for posting.
@mlenstra
@mlenstra 2 жыл бұрын
I would’ve liked to see them leave a bit of slack length on the ground wire to help ensure that the ground connection is the last thing to break in case the cable is forcibly pulled out of the housing.
@rud
@rud 2 жыл бұрын
Good to see these things coming down in price. Now we can hope that proper type2 cables will come down in price as well so they are no longer +$250 items.
@ZomB1986
@ZomB1986 2 жыл бұрын
1:40 100% Chinese font detected. Doesn't mean Chinese quality though. Where I work we closely collaborate with a Chinese manufacturer and for the final products it's quite random which parts of each product they will design and what parts we design.
@ANTALIFE
@ANTALIFE 2 жыл бұрын
Loving the curvy traces ;^)
@emmettturner9452
@emmettturner9452 2 жыл бұрын
You might want to go lower when using with a source that you know can’t handle 15A. For example, a worn out outlet. It’s why 120v EVSEs often default to 8A and require a manual override for 12+A. Adapters to fit higher amperage outlets often signal this to the EVSE so it can default to 12A or 16A or more. Though a standard NEMA 5-15 in the USA should be able to safely handle a sustained 12A (80% of the maximum 15A rating), they often can’t because they are worn out and loose from too much use.
@NNoradIV
@NNoradIV 2 жыл бұрын
I'm also thinking if you already use the same circuit to power other things, like my outside plugs are also used for my lights and other stuff. If you set the charger to full power, you might blow the breaker.
@drkastenbrot
@drkastenbrot 2 жыл бұрын
gotta love the garbage nema sockets
@__beer__
@__beer__ 2 жыл бұрын
@@NNoradIV 15amp outlets here are generally a dedicated circuit and are not part of the general power circuit with the home. They're mostly protected by a 16amp or 20amp cb
2 жыл бұрын
Anybody else felt a big Electroboom fibe? 🤣
@emmettturner9452
@emmettturner9452 2 жыл бұрын
@@drkastenbrot Well, the grade/intended application is what typically determines how robust it is (consumer versus commercial, industrial, hospital, etc). ;) NEMA just defines the prong configuration and expected amperage when functioning correctly. I’m sure you can wear out a lot of other plug types!
@evensgrey
@evensgrey 2 жыл бұрын
Given that the 15A plug has sleeved pins for the hot and neutral, while the 10A plug doesn't, I would expect the standards for the 15A outlets are substantially higher so they are able to reduce the potential contact area on the pins.
@m4d3ng
@m4d3ng 2 жыл бұрын
I was of the understanding that these must prevent any dumping of supply into your house wiring should a fault develop in your car which would potentially smoke your house wiring in an instant.
@casainho
@casainho 2 жыл бұрын
Great video, thanks!! So much good details for use to learn, great job.
@sinasattari
@sinasattari 2 жыл бұрын
I would have put the screw lugs further apart avoiding the possibility of ring terminals rotating and causing a short across.
@hannahranga
@hannahranga 2 жыл бұрын
If the terminations are that loose a short is probably less than bad than a fire from a high resistance connection.
@DelticEngine
@DelticEngine 2 жыл бұрын
Great video! I don't have an electric car (yet!) but I would really like to see this modded into a smart extension lead, possibly with remote on/off capability. The remote on/off would be good if it was 5V triggered so it could be activated by, for example, the 5V from a USB lead becoming live when a computer starts up. It could also be triggered as part of a non-EV battery charging setup, to switch on a 12V car battery charger when it is connected to the battery, for example, and show the amount of charge going into the charger and on into the battery.
@slavric
@slavric Жыл бұрын
Hi. I use cheap "smart" energy meter for this purpose, about 25€. Unfortunately you need enclosure for that. Also you can buy "smart" 20A plug, but I prefer solid connections since the plug can overheat at this current.
@randycarter2001
@randycarter2001 2 жыл бұрын
That means the device is NOT SAE J1772 compliant or the European equivalent. That diode is there so that if the plug is dropped in a puddle of water the power can't be switched on. It should also throw a fit because the earth circuit is open. Even the piece of junk that came with my Leaf stopped when the earth connection opened.
@telwood15
@telwood15 2 жыл бұрын
Good video and all in one breath.
@catalinalb1722
@catalinalb1722 2 жыл бұрын
Dave, Wiha or Wera as for the best screwdrivers ? :)
@moestrei
@moestrei 2 жыл бұрын
Type 2 goes up to 44kW or 64A 3 phase. Early Renault Zoe could be charged at that rate.
@landspide
@landspide 2 жыл бұрын
Should the earth lead be longer?
@MrThomashorst
@MrThomashorst 2 жыл бұрын
The Latching relay should not be a problem. At least for the car, because the contactor block on your ev battery will disconnect when the communication is interrupted.
@nickhill9445
@nickhill9445 2 жыл бұрын
Interesting it uses latching relays. Another approach might be to use 12v to activate the 12v relay, then drop the voltage to reach it's holding current. This would drop power consumption from 1.5w per relay to maybe 0.26w per relay.
@Nautilus-v8p
@Nautilus-v8p 2 жыл бұрын
The NTC is for the temperature sensor in the plug(the EV charging plug, not the 3-pin plug). The older design normally has this feature for redundent protection. But you need special cable and special plug to accomate this feature which adds cost. Anyway, it's not mandatory, at least not in China. BTW Chinese standards do not permit 32A on this kind of boxes, they have to be permanently installed.
@mrx.2233
@mrx.2233 2 жыл бұрын
Hi Dave, if I may suggest maybe you can do a tear down of a Vitron Energy Inverter Single phase and three phase.
2 жыл бұрын
They don't have a live/neutral swap relay? For example schuko plug is unpolarized, but probably the car expects N and L1 to be in the right order.
@m1geo
@m1geo 2 жыл бұрын
The Tesla EVSE definitely has an NTC sensor in the mains plug in the UK.
@neuropilot7310
@neuropilot7310 2 жыл бұрын
I'm surprised they didn't use a super-capacitor somewhere to unlatched the relay if power is lost while charging.
@samj4348
@samj4348 Жыл бұрын
Thanks for the review - I got this one in 10amp! This might be a silly question, but is it safe to use outside if the ground is damp or it is raining? Assuming the power point itself is covered. What about if I use it with an extension cable - is there anything to keep in mind? Most of the time it would be in a covered in a garage, but I'm thinking of when we are on holiday where the car is outside and the power point is a little while away (i.e. cable will be running along the ground possibly with a extension cable)
@sunhuatom
@sunhuatom 2 жыл бұрын
Looks like designed by one of the daughter companies of the State Grid. These guys dont mess around, absolute all of their products spare no cost, but not necessarily good looking. For normal Chinese companies, at least the phoenix connectors won't be there during mass production.
@petersage5157
@petersage5157 2 жыл бұрын
14:07 That odd kink in the application schematic at the line side; I don't understand why they would draw it like that. Splainy?
@shaun2072
@shaun2072 2 жыл бұрын
Sad to see the dip switches left alone, what modes hide within?
@FrankGennari
@FrankGennari 2 жыл бұрын
I think the two green connectors are just there for the wires to rest on as a sort of strain relief to help keep the screws from coming loose due to vibrations. Or maybe they could be secondary connectors for the lower current model.
@notathome13
@notathome13 2 жыл бұрын
Where the ctick(or equivalent) Aussie stand mark?
@jonmusgrov
@jonmusgrov 2 жыл бұрын
Dave throw it outside overnight with the rain you'll be having you'll know if the ip rating would hold up the 8amp feature would be good for those who attack the earth pin with a grinder (not using safety glasses just the safety squint) so it can fit in a standard 10amp socket
@barrieshepherd7694
@barrieshepherd7694 2 жыл бұрын
Lot of effort - cut the plug off and install a 'standard' one 😊😊
@tin2001
@tin2001 2 жыл бұрын
@@barrieshepherd7694 Or safer - Bunnings sells a box with a breaker in it that lets you plug a 15A into a 10A socket. Has an RCD too. Down side is it's $85. But your house is probably worth a little more than that.
@pepecrisostomo357
@pepecrisostomo357 Жыл бұрын
Great video! Do you know how they actually limit the maximum current through to the car?
@SeanBZA
@SeanBZA 2 жыл бұрын
Phoenix connectors are probably there for factory test purposes, simply plug in a loom and no need to use the heavy connectors or a special test jig, just 2 flying leads on cables for multiple models.
@EEVblog
@EEVblog 2 жыл бұрын
That's what I spectulated. Can't remember if I edited that bit out?
@SeanBZA
@SeanBZA 2 жыл бұрын
@@EEVblog Seems likely if they do a whole range of different EVSE units, cheaper to simply have flying leads, and the odd other connector for some semi automatic test rather than a dedicated station per unit. Just mark them with a colour code for specific model variants and you can use untrained people to plug in, press button, and get green light.
@Nautilus-v8p
@Nautilus-v8p 2 жыл бұрын
Ehh I'm pretty sure this thing does not comply with standard. It is NOT supposed to charge without PE properly connected. It is designed for crazy domestic market which PE connector is not always available( PE connector is mandatory, but dut to various reasons it is possible to be absent). Older EV charger just follows the code, but get too many complaints from the consumers due to missing PE connector. The new design, as you see, completely ignored PE connector detection feature described in the standard.
@maxwang2537
@maxwang2537 2 жыл бұрын
“Minor band”? Possibly I don’t know. The top right corner of the schematics shows Fudan Microelectronics. Fudan is one of the top universities in China.
@transmitterguy478
@transmitterguy478 2 жыл бұрын
I expect cordless charging to be built into all parking places, especially in a new home driveway and garage. You pull your car into a spot that automatically charges your car, like your phone. The user ID will be detected and the usage will go onto your monthly bill.🚙
@moestrei
@moestrei 2 жыл бұрын
Way too much losses.
@nathanthomasrecruiter
@nathanthomasrecruiter Жыл бұрын
Quick question. Is this RCM approved? I want to know how I can check if this meets the AUS standards. Cheers
@rasimbot
@rasimbot 2 жыл бұрын
Funny how Dave is scrolling Chinese datasheets like he can read them
@AnotherPointOfView944
@AnotherPointOfView944 2 жыл бұрын
Maybe he can?
@hikaru-live
@hikaru-live 2 жыл бұрын
The company that made the device is related to State Grid of China, and that company has rigid safety standards for its products and services, That may just propagate to its subsidiaries.
@FalcoGer
@FalcoGer 2 жыл бұрын
Here we have brown for the color that your pants go when you touch it, blue for neutral and a fancy yellow/green striped one for earth.
@tarassu
@tarassu 2 жыл бұрын
Chief engineer, we need a plug that carries more amps... I know, let's take the last one and make the GROUND pin bigger.
@neutron7
@neutron7 2 жыл бұрын
You must hate guitar pedals with their backwards signal flow.
@JohnEnergy2012
@JohnEnergy2012 2 жыл бұрын
Power other stuff is the main reason to select lower:
@Hhtfvhrcbgrejkkjhffvbhb
@Hhtfvhrcbgrejkkjhffvbhb 3 күн бұрын
Chager not on bms battery. Sir how to on charger without bms . Any tips for can comunication. Testing purposes on charger 😢😢
@Knorrkator
@Knorrkator 2 жыл бұрын
Is it safe to let these draw the maximum current the socket supports (16A) for several hours?
@Knorrkator
@Knorrkator 2 жыл бұрын
Why are these not available without the typ 2 cable and just a socket? Everyone already has a typ 2 cable and now i have to drive around with two
@Sparky400
@Sparky400 2 жыл бұрын
wouldn't that mean a bigger connector and box?
@Knorrkator
@Knorrkator 2 жыл бұрын
@@Sparky400 Slightly bigger box but overall it would be way smaller
@babbadge
@babbadge Жыл бұрын
Why is there only one pwm control wire? Does it use one of the power wires as reference? But the power wires will have a voltage drop due to the high current. Doesn't seem practicle to me! Or the earth wire?
@Kalanag54
@Kalanag54 6 ай бұрын
Yes, the reference is PE
@LawpickingLocksmith
@LawpickingLocksmith 2 жыл бұрын
Neat! Thanks, I just learned something new. EV's are getting more common around the world than downunder. Tesla mounts this sort of box on a house wall. Mercedes takes big money and only gives you a 10A box just as cheap as the MG toy. Well more to come I guess.
@Sparky400
@Sparky400 2 жыл бұрын
is there any reason this couldn't be built into the handle? so the wall plug is on one end, then just a rather bulky handle with all this in it. nothing between. The only issue I could maybe see is the electronics need to be away from the handle in case the handle is tripped or Loses waterproofing and the relays need to be switched off
@EEVblog
@EEVblog 2 жыл бұрын
Possible in theory, but would be bulky in practice for no real major advantage.
@rkan2
@rkan2 2 жыл бұрын
I dunno.. I see no reason why not. Probably no critical mass yet so someone will probably do it soon. Or maybe it is some weird part of the CCS standard to not be allowed to have it in the handle?
@Sparky400
@Sparky400 2 жыл бұрын
​@@EEVblog advantage being nothing bulky on the ground to have to worry about. IE hanging off that wall or what ever. maybe less points of water ingress and cable connections.
@Sparky400
@Sparky400 2 жыл бұрын
​@@rkan2 I should try and read up on the standard. I suspect that's the case.
@mikeselectricstuff
@mikeselectricstuff 2 жыл бұрын
There is a reason, if it was in the charge plug the rcd couldn't protect against cable damage.
@jeffgorkisch4489
@jeffgorkisch4489 2 жыл бұрын
Nice parts, should be rated for 20amp like most heavy usage appliances in the US. My freeze dryer requires a dedicated 20smp circuit. It's funny an electric car does not.?
@sarowie
@sarowie 2 жыл бұрын
you do realize that most of the world is 220/230/240V and the US is 110/120V? Doubling the voltage means four times the power for the same current. Yes, you can argue multiphase, but that also exists every where, just a question of two or three phase.
@RetroAnachronist
@RetroAnachronist Жыл бұрын
I’d have thought you’d go the OpenEVSE route. Build one yourself.
@murraymadness4674
@murraymadness4674 6 ай бұрын
I've been asking on every video...does evse j1772 interface really require -12v in the pilot signal? It is only using the positive voltage as the signal and the duty cycle, I see no reason for -12v
@Kalanag54
@Kalanag54 6 ай бұрын
-12V is necessary for the mandatory diode checking.
@BlackXeno
@BlackXeno 2 жыл бұрын
Isn't risky to have the cables screw like that? If for any reason a screw get loose, a cable can rotate and touch the neighbors...
@andreidoimetri
@andreidoimetri 2 жыл бұрын
@6:20 green for earth, I'm sure that is yellow
@benjaminhanke79
@benjaminhanke79 2 жыл бұрын
Do these EVSEs work on an inverter? Is it possible to charge your car from one of these battery packs with 2000W output? Just to have a few extra kilometres for emergency.
@mahmoudgaber5347
@mahmoudgaber5347 2 жыл бұрын
Speaking about the copper thickness @10:32..... I'm designing a pcb in which one polygon holds 25A.... how can I decide the proper thickness...thank you
@platin2148
@platin2148 2 жыл бұрын
We should really standardize on a single plug to rule them all.
@worroSfOretsevraH
@worroSfOretsevraH 2 жыл бұрын
So you could just hack together a simple circuit to fool the car's charger, and apply mains to charge it without this box?
@pdev9414
@pdev9414 2 жыл бұрын
if you do not mind getting electrified in case of an issue, you only have to apply the right duty cycle with +-15V levels and adding 2 resistors or so. NOT recommend! An EVSE is ad Dave says, not a charger. It is a safety device that can tell the car what max current if can take and only close the relays if there is no earth fault (AC and DC if correctly done)
@montenegro3167
@montenegro3167 2 жыл бұрын
nice video
@africanelectron751
@africanelectron751 2 жыл бұрын
Dreams in South African of one day having a ev....we don't even have reliable electricity supply.
@cristifl
@cristifl Жыл бұрын
Can I mod a three phase mobile charger to allow more current. I have a common three phase charger from Aliexpress, that is limited to 16A per phase. It works also with single phase, but limited to 16A or 3.7kw. I want to mod it to draw 24A single phase. Is it possible?
@mikeselectricstuff
@mikeselectricstuff 2 жыл бұрын
The 2902 may be driving the PWM as it's a bipolar signal
@EEVblog
@EEVblog 2 жыл бұрын
Could be. There is a capacitor divider coming from the AC charger side, maybe that provides the 12V required. But doesn't make sense beign on the switched charger side.
@MrFrednurk23
@MrFrednurk23 2 жыл бұрын
@@EEVblog I don't think the 2902 has enough slew to drive the +/- 12V 1kHz PWM signal . (At 8% duty the pulse is 80us wide but the 2902 rise and fall time might be 12us.) It is probably part of a the AC voltage sensing circuit feeding the HT7017 voltage input. You pointed out the two string of HV resistors that would be part of this.
@mscir
@mscir 2 жыл бұрын
Great video, thanks. Any chance you'll open up a Tesla model?
@3v1Bunny
@3v1Bunny 2 жыл бұрын
this looks like '90s mid 90's build quality.. Everything crimped / connectors wonder what the top range models look like inside now.
@jarinaumanen8447
@jarinaumanen8447 2 жыл бұрын
Ground wires should always be longer than phase wires.
@barrieshepherd7694
@barrieshepherd7694 2 жыл бұрын
?? Most fixed wiring in the UK has smaller ground wires than L (Active/Phase) & N. e.g. in 2.5 mm cables (not flexes) the earth is usually 1.5 mm - I believe that 1.5 mm is considered adequate to blow a 32 amp breaker.
@hannahranga
@hannahranga 2 жыл бұрын
@@barrieshepherd7694 longer not thicker, so if the cable gets yanked out you can't have the scenario where the earth is snapped but the active/neutral are still connected.
@barrieshepherd7694
@barrieshepherd7694 2 жыл бұрын
@@hannahranga My bad I initially read that as thicker.
@vonnikon
@vonnikon 2 жыл бұрын
Surprising that they removed soldermask in an attempt to improve condictivity: It doesn't really work. The conductivity of tin is so bad that it makes no meaningful difference. Better to just keep the soldermask to protect against oxidation.
Edd China Reveals the Shocking Truth About EV Battery Repair
19:52
Electric car chargers aren't chargers at all - EVSE Explained
27:19
Technology Connections
Рет қаралды 2,1 МЛН
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 36 МЛН
Quando eu quero Sushi (sem desperdiçar) 🍣
00:26
Los Wagners
Рет қаралды 15 МЛН
EEVblog 1518 - Hoymiles Solar Microinverter TEARDOWN
26:20
EEVblog
Рет қаралды 106 М.
Your Powerbank has 1 BIG Problem! (That we can "Hack")
12:13
GreatScott!
Рет қаралды 368 М.
Playing Music on the Oldest Running Computer in America!
27:06
Usagi Electric
Рет қаралды 392 М.
EEVblog 1497 - RIP Fluke. Thanks Energizer. NOT.
19:28
EEVblog
Рет қаралды 103 М.
EVIQO EVIPOWER Smart EV Charger Review
21:54
Josh Charles
Рет қаралды 2,4 М.
The Truth about EV Battery Life and Charging Best Practice ! | 4K
23:46
Noco Boost Plus GB40 Lithium Jump Starter | Can I Fix It?
53:27
Buy it Fix it
Рет қаралды 363 М.
The EASIEST way to connect used EV packs to grid! 🔋
7:35
Dala's EV Repair
Рет қаралды 590 М.