REVIEWED: BG CONSUMER UNIT 2021 updates - what's new?

  Рет қаралды 10,291

eFIXX

eFIXX

Күн бұрын

Пікірлер: 111
@glenwoofit
@glenwoofit 3 жыл бұрын
I've always been a Wylex installer as I try to stay away from the cheaper consumer units but I do like that BG are listening to us and improving their products to suit.
@efixx
@efixx 3 жыл бұрын
Thanks for commenting and watching 👍
@travoltasbiplane1551
@travoltasbiplane1551 3 жыл бұрын
Same. Although I'm not aware of a recall on the scale of what wylex had!
@glenwoofit
@glenwoofit 3 жыл бұрын
@@travoltasbiplane1551 True.
@farmersteve129
@farmersteve129 3 жыл бұрын
One improvement would be to have positive retention of the busbar shield via clips or screws - I've often had the shields fall out when removing covers on quite a few different boards. I think that I've previously mentioned that I'd also like to see proper clamping terminals for neutral and earth/CPC rather than screwing directly onto the copper conductors. Nearly every board I've looked at has at least 1 pinched conductor - often on 1 & 1.5mm conductors. MCBs & RCBOs have them, so why not the other terminals? Ditch the bubble because it isn't going to be reliable - any tradie that doesn't use an appropriate size level that can be tested against itself needs to be retrained!
@tonyyoung8232
@tonyyoung8232 3 жыл бұрын
Have fitted lots of these boards without issue. Solid and well finished. The old wylex fusewire boards fitted millions and they are still about today. We have come a long way !
@efixx
@efixx 3 жыл бұрын
Great comment
@callumthomson2154
@callumthomson2154 3 жыл бұрын
Im new to industry and have been recently installing a load of these. Love the built in Gary Neville. Find them great, loads of room, nice screws, easy to make them dressed properly and neat. I often wonder why they supply the B40 in these modern times, a lot of the flats / houses I work on would benefit from a B20 or two or an extra B16 instead. Not experienced many different brand of boards so forgive me if I'm just in a honeymoon period with these.
@brianwood5220
@brianwood5220 3 жыл бұрын
Nice work BG.I'll be recommending this to friends and colleges from now on. Thanks for sharing guys.
@efixx
@efixx 3 жыл бұрын
Thanks as always Brian 👍
@iScoTT29
@iScoTT29 3 жыл бұрын
Biggest improvement I can see is the lid being hinged from the middle instead of the bottom. This will make running trunking under the board possible now without block the lid from opening 👍
@carlrobson5745
@carlrobson5745 3 жыл бұрын
Liking the spinal tap reference.
@efixx
@efixx 3 жыл бұрын
Goes to 11
@ajmelectricalcontractors
@ajmelectricalcontractors 3 жыл бұрын
One thing I've noticed about the BG consumer units is you have to take the busbar out to fit an additional MCB and the lids a little trickier to get on, on the whole though I think its a pretty solid consumer unit
@oldbutstillcurious3615
@oldbutstillcurious3615 3 жыл бұрын
Removing the busbar just to replace an MCB, ? why - that seems a bad design.
@pwoody8587
@pwoody8587 3 жыл бұрын
I’ve installed a few BG boards, they seemed to be a good quality and well built, but that plastic grommet for the back cable entry comes loose very easily, as soon as cable touches it, it pops loose. What I do now is drill 4 holes 3mm around the edges of the grommet and use some mini tie wraps to hold it in place jurying installation. Makes life easier
@efixx
@efixx 3 жыл бұрын
Great tip 👍
@Ant86744
@Ant86744 3 жыл бұрын
Mount it to the back so when pulling/ pushing the cables through the hole it holds better in place then as your pushing the plastic on the base
@Ant86744
@Ant86744 3 жыл бұрын
Not away from the consumer unit
@rayc1503
@rayc1503 3 жыл бұрын
Small dab of super glue works all the time for me.
@Dog-whisperer7494
@Dog-whisperer7494 3 жыл бұрын
Nice to see there is a lot more room for dressing in the circuit cables 👍 And another great video from team eFix thank you guy’s
@HAelec1
@HAelec1 3 жыл бұрын
Another good thing about these CU’s is there’s a stop on the right hand side to push the main switch up against that some others don’t have which can be a pain if you’re not fully loading the board and you put the lid on there’s a gap and you then have to go back and slide everything along and potentially redress some cabling. Fitted many of the previous version of these before I changed over to there RCBO units and can’t fault them on the price and quality
@raymondbrooke4334
@raymondbrooke4334 3 жыл бұрын
7kp
@raymurphy9749
@raymurphy9749 3 жыл бұрын
Do you still have to allow 6 hrs added on top of a board change to get the lid on?
@andrewscott6078
@andrewscott6078 3 жыл бұрын
Been there got the t shirt
@dimitrakisaimegia3852
@dimitrakisaimegia3852 3 жыл бұрын
Ahahhha gold
@johnoreilly7052
@johnoreilly7052 3 жыл бұрын
Hi Gary thanks for sharing your video with me and I would love to see a lot more of your videos and also I love using BG boards and they are a good space to terminated the conductors into the board
@altinbasha9511
@altinbasha9511 3 жыл бұрын
All the ways I’ve been using BG, I think it’s a great product.
@oldbutstillcurious3615
@oldbutstillcurious3615 3 жыл бұрын
The projections on the sides of the base keep the base away from walls etc, thus allowing the lid to be fitted easily. Other videos have commented about various brands where installers had forgotten about the lid overlapping the base and had to butcher the lid or adjacent wall or cabinet simply to fit the lid.
@waynio67
@waynio67 3 жыл бұрын
Still no use as I never fit split RCD CU’s any more, RCBO boards for me now
@Ant86744
@Ant86744 3 жыл бұрын
They do rcbo boards with spd, and go up to 55a in the rcbo
@thattoolguy9432
@thattoolguy9432 3 жыл бұрын
I tend to only fit Wylex boards, but that BG boards looks solid and neat enough, only thing i spotted is the 32mm knockout at the bottom wasnt directly below the gap at the side of the main switch, would make it a lot easier fitting tails bottom entry and just look nicer overall.. nothing that cant be sorted with a starrett
@stuartbrown2567
@stuartbrown2567 3 жыл бұрын
Always liked BG because there front dropped down but noticed you now have to lift it up, which I find a bit of a pain when refitting, but glad to see they have now add SP. May be yo could do a video on the one with the MCBOs. Keep the videos coming.
@rayc1503
@rayc1503 3 жыл бұрын
With the lid dropping down over the switchgear. The CU has an improved fire rating. A bit of a pain if you have to hold it up, but hey-ho.
@conradknightsocksknight1590
@conradknightsocksknight1590 3 жыл бұрын
Love that the RCDs are type A you should say why this is better. Tails grip and a gland for the tails would be nice. Pity about the cheap nasty plastic blanks.
@marcusshipley3935
@marcusshipley3935 3 жыл бұрын
A lot of people are down on the BG boards, they're very similar to Hager in design (I believe the same designer) I do regularly fit these and there are only three improvements I'd like to see implemented. They are a welded bracket to clamp the tails into position, metal blanks as standard and fire retardant grommets supplied as standard.
@Spark101.
@Spark101. 3 жыл бұрын
Good video guys. Unfortunately, BG are at the cheaper and nastier end of the market in my opinion. Even with the changes. Everything screams cheap.....and nothing about it looks high end. On a positive note....I started using Lewden recently and I am pleasantly surprised. The quality feels great!
@efixx
@efixx 3 жыл бұрын
Thanks for adding your thoughts K C 👍
@andrewscott6078
@andrewscott6078 3 жыл бұрын
Lewden is great value and nice tall board
@rayc1503
@rayc1503 3 жыл бұрын
Agree, Fusebox by CP electrics are also pretty decent, good value CU's. Hager wins as they're readily available.
@user-wc1nd9ie6x
@user-wc1nd9ie6x 3 жыл бұрын
You lads should have a look at the ‘Live” fuse board, put one in the other day for the first time- I like them! Reasonably priced and come with all the mcb’s
@crumps84
@crumps84 3 жыл бұрын
I'm just here to read the DIY Dave comments...
@phillee2171
@phillee2171 3 жыл бұрын
BG boards are absolute crap. Wylex or CP boards are much better
@oldbutstillcurious3615
@oldbutstillcurious3615 2 жыл бұрын
@@phillee2171? In what way(s) ar BG boards unsatisfactory ?
@darrencoll6782
@darrencoll6782 3 жыл бұрын
where do u buy this new version only see old versions on line
@alpachino468
@alpachino468 2 жыл бұрын
What's the difference between the 'Fortress' and the non-'Fortress' range?
@triplerjm2353
@triplerjm2353 3 жыл бұрын
Never been a fan of BG Board but since your last video about GB Board and was tempted to try it, which I did use few board but didn’t like, was finding it difficult to close the cover.
@dimitrakisaimegia3852
@dimitrakisaimegia3852 3 жыл бұрын
Always problems with the cover. Contactum is the best when it comes to the cover.
@danf6491
@danf6491 3 жыл бұрын
Is there a meter tails clamp? Will we ever see a wago consumer unit to match that amazing socket outlet you own
@andytap560
@andytap560 3 жыл бұрын
Id fit bg over mk,have done on budget restriction jobs with no problems but generally stick with contactum or fusebox.
@efixx
@efixx 3 жыл бұрын
Thanks for commenting Andy 👍
@efixx
@efixx 3 жыл бұрын
Andy an I correct in thinking the fuse box RCBO’s are to be tightened to 1.2 Nm of torque...?
@andytap560
@andytap560 3 жыл бұрын
@@efixx yes they write the figure on rcbo’s and earth/neutral bars.
@johnnythefixer
@johnnythefixer 3 жыл бұрын
Have you taken a look at the EnviroBurst fire suppression system yet. I've seen some videos on it, and it looks pretty good for extinguishing any internal fires before they get out of hand.
@aspudkicker
@aspudkicker 3 жыл бұрын
Why are BG glands so expensive? A set of BG glands costs nearly as much as the c.u.
@efixx
@efixx 3 жыл бұрын
Thanks for commenting
@Ant86744
@Ant86744 3 жыл бұрын
Ask the retailer you are buying from as its there mark ups 60% upwards that sadly make the product more expensive
@rayc1503
@rayc1503 3 жыл бұрын
Wylex glands fit amongst others.
@Spark101.
@Spark101. 3 жыл бұрын
Why not make both RCD’s 100amp?
@efixx
@efixx 3 жыл бұрын
We ask that question 👍
@AndyK.1
@AndyK.1 3 жыл бұрын
Cost! And it’s really not needed! 80 is plenty
@Spark101.
@Spark101. 3 жыл бұрын
@@AndyK.1 There is no cost difference, and it is needed in many cases
@AndyK.1
@AndyK.1 3 жыл бұрын
@@Spark101. They need thicker wire around the ferrite, so material costs are more even if they sell individual units to the public at the same cost.
@Spark101.
@Spark101. 3 жыл бұрын
@@AndyK.1 but if they sell them at the same cost, they must be able to afford to make them all 100amp at that cost
@desmondyoung5963
@desmondyoung5963 2 жыл бұрын
The boards are first class quality. I would like to have an option of knockouts to take electrical trunking into the board. example 50MM x 50MM
@dg2908
@dg2908 3 жыл бұрын
Nothing wrong with keeping spare MCBs on the van; why would you leave breakers in the board that aren't required in the installation? Preloaded boards will always encourage compromise- installers need to plan their work before doing it. The last BG boards (metal with hinge at bottom) needed the board lid shut to get it on then open to do up the screws so it wasn't ideal. Never fitted a BG board- I'm happy with other makes that have been selling me DP Type A RCBOs and SPDs without dedicated breakers for 18 months. I've never seen a BG board with its bubble level. Is it the product or the installer that's poor?
@lewis94uk
@lewis94uk 3 жыл бұрын
BG quality has always been okay the problem with them is that BG seems to be the kitchen fitter board of choice.
@user-wk7wv8rn8h
@user-wk7wv8rn8h 3 жыл бұрын
As soon as I see one I prepare for the worst; like you say its the screwfix special but the quality isn't inherently bad just the installation most the time
@phillee2171
@phillee2171 3 жыл бұрын
Worst board of the lot.
@MS-Patriot2
@MS-Patriot2 3 жыл бұрын
@@phillee2171 do elaborate please..
@phillee2171
@phillee2171 3 жыл бұрын
@@MS-Patriot2 board is filmsy, has to mounted tons perfect surface. MCBs don't sit square when torqued to specs, which you struggle to fit the lid on. No A type RCDs easily available on the split load boards. The quality of the manufactured crimped neutral connections is poor. As a brand I generally avoid.
@MS-Patriot2
@MS-Patriot2 3 жыл бұрын
@@phillee2171 Thanks Phil, I was about to use a metal 5 way with type A in a garage, looked ok to me for that job. Probably not for indoor. As you imply, plenty of choice nowadays. What is your preference?
@Chris_In_Texas
@Chris_In_Texas 3 жыл бұрын
Being in the US, what is the average cost difference between a dual RCD vs just springing for the fully RCBO based consumer unit? I am surprised that the demand is still high for dual RCD instead of just moving to RCBO based CU. I must say with our load centers with neutral bus bars now for the breakers installing our AFCI/GFCI breakers are so much cleaner without all the extra tails in there. Personally we have 240V 400A (dual 200A panels) service feed with 80 breaker spaces, and in ours 72 breakers are being used. Its funny to see houses with 60/80 or 100A feeds and have the amount of high draw devices like electric showers, boilers, ovens, stoves and even EV chargers etc. It would seem the UK will soon burst into flames in 2030! 😁😁🍻 With all the extra loads of EV's going in and the state of some of the service entrance cables I have seen on some videos, I assume the power companies have to gear up for all these changes as well?
@AndyK.1
@AndyK.1 3 жыл бұрын
Rcbos are at least £15 each. Mcbs almost free.
@jblaze260
@jblaze260 3 жыл бұрын
hate bg boards with a passion always there for 3 hours trying to get the cover back on lol, i always go hager
@AndyK.1
@AndyK.1 3 жыл бұрын
Only thing it’s missing is tail clamps which is the latest rage
@markhedley8587
@markhedley8587 3 жыл бұрын
Certainly not board of choice, I can see some improvements but still wouldn't choose this over a Hager even if it is cheaper. Most common fault I've come across on the BG boards have been failed RCD's,
@acelectricalsecurity
@acelectricalsecurity 3 жыл бұрын
BG get a bad rap only because of Screwfix. They have been around years and I think their stuff is ok, yes the din rail would drop down, but that was the same with mk and others. I have never been a fan of twin RCD boards, but it looks ok on the face of it.
@barrett407
@barrett407 3 жыл бұрын
Someone listening to feedback
@efixx
@efixx 3 жыл бұрын
👍
@scott1506
@scott1506 3 жыл бұрын
hope they not kept the old cover design. was shocking quality . even to get it to fit and screw on was a task.
@michaelwhite28
@michaelwhite28 3 жыл бұрын
Who still installs dual RCD boards in 2021?
@efixx
@efixx 3 жыл бұрын
See Instagram
@travoltasbiplane1551
@travoltasbiplane1551 3 жыл бұрын
I'd be more concerned about who'd install BG full stop... It's down there with chunt. Nasty DIY kit.
@markyd2633
@markyd2633 3 жыл бұрын
Maybe they will listen to feedback about their accessories, switches and sockets total crap
@andytap560
@andytap560 3 жыл бұрын
@@markyd2633 so re MK now,utter shit
@AndyK.1
@AndyK.1 3 жыл бұрын
Sadly lots. Including brand new houses
@utherpen69
@utherpen69 3 жыл бұрын
First again! This getting to be a habit :-)
@ColinRichardson
@ColinRichardson 3 жыл бұрын
But why not make 10 louder?
@liamjordan5935
@liamjordan5935 3 жыл бұрын
What's the point if you do tell us the price . U just made me watch this and no price , Toilet paper no toilet paper yeh I no They had to make those adjustments cus u couldn't get lid on and s-level rubbish, also how many have u two fitted ?? None in the last 5yrs fact Keep up the good work
@TeamSimpsonRacing
@TeamSimpsonRacing 3 жыл бұрын
Plastic blanks supplied for a metal clad board 😏
@efixx
@efixx 3 жыл бұрын
What are the MCBs made of?
@TeamSimpsonRacing
@TeamSimpsonRacing 3 жыл бұрын
@@efixx plastic but not super wafer thin like the blanks.
@markyd2633
@markyd2633 3 жыл бұрын
Now to sort out their switches and sockets.......rubbish
@splodders
@splodders 3 жыл бұрын
They were an ok board, but split load CUs are a thing of the past. We shouldn’t be fitting them now.
@Xoreaf
@Xoreaf 3 жыл бұрын
Why are you guys still promoting split load boards? People need to stop putting this archaic rubbish in.
@amatchmadeindevon2005
@amatchmadeindevon2005 3 жыл бұрын
No decent sparky should be fitting these anymore, with the price of fusebox RCBOs, look at the size of the bloody thing, needs its own council tax band
@efixx
@efixx 3 жыл бұрын
See Instagram - you don’t see many full RCBo Hager boards!
@oldbutstillcurious3615
@oldbutstillcurious3615 3 жыл бұрын
Thanks for the size comment, made me laugh out loud!
@curtismal1726
@curtismal1726 3 жыл бұрын
Why is anyone still fitting split load?!?! Hate BG with a passion after fitting better brands
@efixx
@efixx 3 жыл бұрын
Most new builds still use split load boards.
@oldbutstillcurious3615
@oldbutstillcurious3615 3 жыл бұрын
What has made you hate BG. ? were they plastic or metal cases ? other problems.
@garethmcguire632
@garethmcguire632 3 жыл бұрын
I hate BG boards. They are just 💩
@madhatter61
@madhatter61 3 жыл бұрын
I wish you'd stop all this dressing of cables nonsense. Cables get routed not dressed.
@oldbutstillcurious3615
@oldbutstillcurious3615 3 жыл бұрын
Either way, there's not much through traffic through a distribution board.
LEWDEN CONSUMER UNIT with DOUBLE POLE RCBOs
13:42
eFIXX
Рет қаралды 42 М.
Electrical Connections Behaving Badly
23:40
eFIXX
Рет қаралды 16 М.
Try this prank with your friends 😂 @karina-kola
00:18
Andrey Grechka
Рет қаралды 9 МЛН
BG Consumer Unit Bodge Up - Part 1
21:57
Artisan Electrics
Рет қаралды 75 М.
The BG Consumer Unit Update: What's Changed?
9:51
eFIXX
Рет қаралды 28 М.
Inside the V3 Nazi Super Gun
19:52
Blue Paw Print
Рет қаралды 1,9 МЛН
NEVER install these programs on your PC... EVER!!!
19:26
JayzTwoCents
Рет қаралды 4,6 МЛН
Should you install a full AFDD or RCBO CONSUMER UNIT?
10:24
Try this prank with your friends 😂 @karina-kola
00:18
Andrey Grechka
Рет қаралды 9 МЛН