Man, that was rough watching you work in this July heat here in Jersey 😢. Much respect especially when you show mistakes…that’s the instructor in you 👍👍🏆🏆
@electricianron_New_Jersey5 ай бұрын
@@chuckq54 Do it right the first time. If not, then do it right the second time.
@electricianron_New_Jersey5 ай бұрын
@@chuckq54 It was brutal. Today the suns not out at all and I’m loving it.
@chuckq545 ай бұрын
@@electricianron_New_Jersey yeah, cloudy here in South Jersey too 👍
@bigtroll82495 ай бұрын
@@electricianron_New_Jersey thank you so much. I like to see you correct your mistakes. I learn a lot for those lessons 👍
@swiftswamp5 ай бұрын
you earned my respect by taking the time to fix your mistake.
@Ben_electric5 ай бұрын
Im a young electrician that just started my own company last year. Ive still got a lot to learn, so thank you so much for sharing your work. Ive picked up a lot of little tricks from watching your videos. I did a service upgrade the other day and it kicked my butt. You make it look so easy! I respect and appreciate you Ron. And beautiful install as always!
@electricianron_New_Jersey5 ай бұрын
@@Ben_electric trust me, I’ve made plenty of mistakes so that’s normal if you ask me.
@Precocktrigger5 ай бұрын
@@electricianron_New_JerseyI'm glad your honest must guys act like they never make a mistake
@BearStar15 ай бұрын
In Texas we use a Bare # 6 Solid CU as the Grounding Electrode Conductor for Residential Service from 100 Amp up to 200 Amp.We also sleeve it 1/2 '' EMT or 1/2 '' Schedule 40 PVC sometimes to make it look better, if the Home Owner asks for it. And since the Water Meters are underground by the curb we are not required to install a bonding jumper at the meter. And we only have to install one 5/8'' Copper Brass Ground Rod near the Main Service Outside Disconnect. And just to let you know Ron , I'm not a '' Arm Chair '' Electrician ! I'm a State Licensed Journeyman Electrician/Sub Contractor with 56 years in theTrade, Residential & Commercial.
@jamescollins8148Ай бұрын
I like that grounding bridge!👍
@joshman23385 ай бұрын
This is a prime example of making it happen. It shows how every service upgrade can pose a lot of challenges hahah. Ron u need to get a little helper for all that crawling around and help you run that SER that must of been a good workout ahhaha.
@electricianron_New_Jersey5 ай бұрын
@@joshman2338 what makes you think a helper would he helpful?
@richb40995 ай бұрын
Very true what you said.....Do work others don't want to and you'll do well......I did exactly that and my working life was always successful. I was an electrician when I was not long out of high school and should have stayed in that line of work. I'm 76 and spent 30 years working on generators of all kinds and sizes for a generator service company. I just retired last year when my company was sold and my job got basically eliminated......Former customers still seek me out and I do a few jobs. I worked on RV generators mostly for quite a while and very few places out there even will touch them......This one was a pretty big job and with the heat we had you earned your money for sure.....Nice job...
@electricianron_New_Jersey5 ай бұрын
Very specialized generator repairs and maintenance.
@50sKid5 ай бұрын
Hey Ron, Milwaukee's been sending me tools to review on my channel for years. I'll see if I can put you in touch with the people who handle that. They aren't spending quite as much money on that program as they used to. It's sort of a lottery/performance-based thing these days, as far as who gets chosen to review a new tool, but you never know. It's good to start these relationships. I think you have one of the best electrical channels on KZbin right now.
@electricianron_New_Jersey5 ай бұрын
That’s very kind of you tk say. Thank you!
@TexasElectrician772 күн бұрын
Nice work, Ron!
@juancortez1195 ай бұрын
Good way i make that whole through roof is attaching a pilot bit to the whole saw . Work like a charm
@steveg55765 ай бұрын
Many folks don't realize a small work table to work from is one of the best tools to have. I carry a wood TV table -- looking for a next size up. Two fans...not fair ! I have one MW.
@electricianron_New_Jersey5 ай бұрын
I literally have 14 fans in my garage and little USB-C fans here at my desk.
@theseattlegreen18715 ай бұрын
The black #6 ground was a real nice hack job! Way to go!👍👍
@electricianron_New_Jersey5 ай бұрын
how do you figure?
@YaksAttack5 ай бұрын
Great looking service! Ive done a few mast services, and ive actually never cut the 2" rigid in a way that ive had to use a compression coupling (or cut new threads god forbid). Technically if you read in PSEGs redbook (or whatever color book it is now), they want you to use straps that go all the way though a framing member or masonry with a nut and washer securing it on the inside of the building. Ive never used them, and never seen them used, but still something thats in the book.
@electricianron_New_Jersey5 ай бұрын
I did not see that in the book.
@davehowell41115 ай бұрын
Fantastic work and video, makes me happy that there still good people out there that go the extra mile and top notch quality workmanship. And ur right Ron good ol fashioned hard work goes along way. My wife and I just recently retired to Florida from Michigan where I was a electrical lineman for 31 years and basically took every opportunity of O/T and we both worked 40+ hrs a week and raised r children and maintained our home. Now we r truly living in paradise and enjoying every single day. So hard work definitely pays off. 👍
@jeffbecraft71744 ай бұрын
Great Job. We use #12x1-1/2 screws... and 2"x24" nipple and rigid coupling to make drop longer. But we in MD. + we have 2 guys. Nice job
@vince68295 ай бұрын
Nice job as always. Thank you for sharing your knowledge and experience.
@electricianron_New_Jersey5 ай бұрын
So nice of you
@michaelm48652 ай бұрын
Great video. Thanks for sharing your install. It would be nice to speak on some of the NEC Code requirements as you go through the process.
@luislazogue80895 ай бұрын
Great video as always, I like the idea of the portable tent.
@andyslime80515 ай бұрын
Thanks for always taking your time when doing your job, i have 3 years experience in new york and is amazing how i learn a lot from you 👏🏻👏🏻
@MurphysSidekic5 ай бұрын
Nice install during a really hot, humid week. I'm not sure if you're on 2023 yet, but the marking / labeling requirement for the emergency disconnect was clarified to dictate the color (red background with white text), and a minimum text height of 1/2". Could be a nice thing for you to start incorporating now so it's already part of your routine when it becomes enforced in your area.
@OzSkyking1525 ай бұрын
I was thinking about having my 100 amp service upgraded to 200amp here in New York and maybe add solar to help offset the cost but for now I will just watch your videos!
@0blivioniox8645 ай бұрын
Nice... I've been aching to see how the masts are done.
@joewhite9175 ай бұрын
The braces between the joists are so that when someone steps on or places a piece of furniture the joist shares the load to to the joists on either side to share the load. Nothing to do with earthquakes.
@electricianron_New_Jersey5 ай бұрын
@@joewhite917 but the bracing prevents the joists from rolling.
@johnsandlinjr5 ай бұрын
100%. Load transfer
@rickbeck-me5jd5 ай бұрын
Could you have used your new riser to come out of meter can and then used threaded end of old cut riser for the 2 feet and the threaded couplimg that comes with them, thus saving having to buy the compression coupling? Also the bridgiing between floor joist is to keep the bottom of the floor joist from twisting.
@tonystrollo1935 ай бұрын
Great job as always Ron I really like watching you work in a professional matter. I really hated to see you work in that heat, but it's not any better here in Florida 100's degree temperatures. Your the best!!! keep the videos coming 😀
@electricianron_New_Jersey5 ай бұрын
Glad you like them!
@johnmazzocchi71165 ай бұрын
Hi Ron! Great job on the service brother! It’s unbelievable how much prices went up on materials . It’s insane!! By the way, I prove the fans you had on your work table. How are they? What doesn’t Milwaukee make these days!! I could have used them Friday in a basement panel change out. Too humid on Long Island here. Have a great weekebd
@electricianron_New_Jersey5 ай бұрын
Thank you, John!
@johnnyrayellison27245 ай бұрын
Awesome video, Ron, as always. I'm sure it's a Challenge at times working by yourself.
@Makitafan5 ай бұрын
Good work Ron. It fought you the whole way. Much respect.
@electricianron_New_Jersey5 ай бұрын
I appreciate that Makitafan
@iN3CROo32 минут бұрын
Great work Ron. Honest question here. Why is it #6 copper for the rods and #2 alum for water pipe? Also, can you just use the 2 new ground rods and not the water pipe? Or perhaps the water pipe and just one rod?
@AndersonElectric5 ай бұрын
Nice video Ron! I'm excited to be apart of each others online communities. I just found out that both of our companies are apart of the IEC. I'm actually a 2nd year student and I do that alongside my job and youtube channel. I just put up a meter/main this Thursday so it is really cool to see how you went about it. Would love to talk to you more about electrical work in the future!
@Eightball25165 ай бұрын
Why would you not use lags on the meter panel combo to mount it like You did with the mast
@ElectroAtletico5 ай бұрын
Just flagged the vid to watch tonight during the night shift (1900-0700). Thanks!!!
@boyd1915 ай бұрын
Hi Ron, I look forward to the 2nd part of this video. That was a crazy run back to the ATS, I'm guessing. I have a couple questions: Are you required to bond the natural gas to service and are you using 4/0 for your neutral in your service riser? Thank you for taking the time to put out these videos. I know it's a lot of work.
@electricianron_New_Jersey5 ай бұрын
If you have natural gas appliances (like a furnace, or gas stove), the natural gas is bonded by the equipment grounding conductor of the circuit supplying power to the equipment. The natural gas pipe entering the home IS NOT PERMITTED to be used as a grounding electrode the way the copper water main is required by the code to be used as a grounding electrode. NEC 250.102
@mcgravelgravel56755 ай бұрын
hello my friend i lern alot from you i do all my eletric work in jamaica an my house .blessing
@electricianron_New_Jersey5 ай бұрын
Just be careful out there. Current leaves the source and returns to the source.
@mcgravelgravel56755 ай бұрын
@@electricianron_New_Jersey ok thank you
@zekenzy64865 ай бұрын
Great video. Good job and nice work. Thank you for sharing
@DavidKingmasterWV4 ай бұрын
You the man Ron😊 !!!
@electricianron_New_Jersey4 ай бұрын
True 😂😂😂
@DavidVerch5 ай бұрын
Wow you really did end up with just enough wire at the end. Sometimes it is better to be lucky than smart.
@hunterstark95562 ай бұрын
Love your work 😎
@electricianron_New_Jersey2 ай бұрын
Much appreciated!
@0blivioniox8645 ай бұрын
Do you ever wind up with kinks in your SER runs? Any tricks for dealing with them in tight areas?
@electricianron_New_Jersey5 ай бұрын
That comes with experience. By walking out the cable like I do before pulling it into the basement, it prevents the cable from getting kinked. It still could get snagged on something and get kinked but its less likely when you walk out the roll ahead of the pull.
@benthomas34185 ай бұрын
Nice job Ron! Love watching your vids. Keep up the great work? Gives me ideas when I’m scoping my jobs!
@ice42785 ай бұрын
Hey Ron what's up nice job. What size aluminum service entrance cable is that. If you were not going through the roof could you use PVC.
@electricianron_New_Jersey5 ай бұрын
4/0 aluminum or you could use 2/0 copper for 200 amp dwelling service.
@fitnesslibrarian9013Ай бұрын
Love your videos. I thought the grounding conductor had to be either bare or yellow or green.
@sevendust076605 ай бұрын
Hey Ron, thank you for all your videos. I live in Bergen county. Just wired my own new build and passed rough-in inspection last week. Your videos have been a great help. I am an electrical PE but to install my own electrical was definitely a new experience. I am working on the service aspect now and was wondering if I could hole saw the PSEG 320A pan in a spot where there are no knockouts. It just would work better for my connection to two 200A Generac service rated ATS’s. Thanks in advance!
@electricianron_New_Jersey5 ай бұрын
Yeah, unfortunately I do not think PSEG will allow you to cut-out your own knockouts in the meter enclosure. That's a utility rule. You could call the construction department and schedule an inspection with one of their supervisors but I do not think they're going to allow it. Good luck with that and I hope this helps!
@sevendust076605 ай бұрын
Hey Ron, you were right, they wouldn’t let me drill. They said it would void the UL listing. Odd since the ATS enclosures have to be drilled; they only have one knockout.
@sevendust076605 ай бұрын
One more question if you do not mind, I have a 350MCM copper feed on the line side of the meter pan. For the GEC, I plan to bury 5/8” rods 8’ min. apart and run #2 AWG in between. From there tap with #4 to each 200A ATS. I also have #4 jumpers to rebar and cold water. My question is, can I bond all three on the ground bus of one of the ATS’s or does it need to happen ahead? Thanks again for all your help.
@gardenjohn13 ай бұрын
Ron, My ranch home built in 2011 has a 200 amp service, 20 circuit panel filled. I want to have a whole house surge protector installed. I may need a sub panel installed, can I get a 20 circuit, have a few needs for extra electric maybe generator, and small sunroom.
@electricianron_New_Jersey3 ай бұрын
@@gardenjohn1 we can add a sub panel or even better install a new 40/ 80 circuit capacity mb panel.
@johnwalker8905 ай бұрын
Great job Ron.......
@edgardobarraza3005 ай бұрын
Good Job . One man band just like me . Stay safe
@electricianron_New_Jersey5 ай бұрын
@@edgardobarraza300 awesome man thank you!
@bigtroll82495 ай бұрын
I love your videos
@kungfurry5 ай бұрын
working on those old houses is an art form. Thanks for all of the informative, detailed videos. If you think of it, can you tell us how long a customer is out of power, on average, when you do a panel upgrade? Thanks either way!
@electricianron_New_Jersey5 ай бұрын
@@kungfurry Anywhere from 6-12 hours. I go to great lengths to keep the time without electricity to a minimum. Always.
@lukehanlon31795 ай бұрын
Hi Ron! Great video as always! Where can I buy that meter main from? Thanks !!
@feelgood34555 ай бұрын
Hey! Can you explain the scenario more? The customer needed a new meter mast and it needed to be in a different location than the original one? Curious the reason.
@electricianron_New_Jersey5 ай бұрын
@@feelgood3455 they wanted it off the front of the house.
@johnvillalovos5 ай бұрын
Great video. Do you use a torque wrench when tightening any of the connectors?
@sblonsky5 ай бұрын
Just curious the reasoning the homeowner wanted the service entrance changed to a new location?
@bigtroll82495 ай бұрын
Prolly cuz the original location was in front of the house and is not asthetically pleasing. Poor curb appeal. Side svc entrance is hidden from view
@electricianron_New_Jersey5 ай бұрын
@@bigtroll8249 that's exactly the reason.
@JoeMack-rm5csАй бұрын
Does pse&g still supply the meter pan or do you have to go to source that from the supply house? What model did you use?
@robertmaciejewski13054 ай бұрын
I got a question, I thought there was a code about using metal EMT straps with PVC isn’t allowed? I don’t know if that’s just a Michigan thing, but I was just wondering? I’m a first year so I’m still learning lol.
@andres7835 ай бұрын
nice work! do you need to call 811 prior to ground rods? here in CA its a requirement...
@electricianron_New_Jersey5 ай бұрын
Not a requirement for ground rods. The gas meter was nearby but I knew the main line came from the street, and not ion the direction of where I installed the ground rods.
@rodolfovesga9795 ай бұрын
Cool video ❤Ron!!!
@electricianron_New_Jersey5 ай бұрын
@@rodolfovesga979 thank you!
@michaelchambers99715 ай бұрын
Can you recommend specific anchors to use with stucco ? I’ve had issues with my plastic anchors pulling right out of the stucco. Thanks
@electricianron_New_Jersey5 ай бұрын
I used my regular plastic anchor with #10 pan head screws. There's six of them in there and it does not move.
@steelfist655 ай бұрын
90 bucks for a stick of 2". Wow, that is insane! Great job, just the same.
@electricianron_New_Jersey5 ай бұрын
@@steelfist65 oh yeah. Might’ve been $80 something
@MrJujubean5 ай бұрын
Hell he said that obe compression coupling was 80 something.@electricalron
@shahrampooee98312 ай бұрын
would you post all your materials for this project?
@Drewchris5 ай бұрын
Good video. Hoping for more.
@zebest33945 ай бұрын
Ron correct me if I am wrong but I thought pseg did not permit the use of combination meter / emergency disconnects yet in NJ?
@electricianron_New_Jersey5 ай бұрын
When I had my meeting with the inspector to get approval for relocating the service drop I asked him point blank and he said as long as the meter portion can be lockable it was allowed. 5th jaw too, you know.
@wirenut90624 ай бұрын
When did PSE&G start allowing 1 family meter mains ?
@electricianron_New_Jersey4 ай бұрын
@@wirenut9062 I spoke the PSEG inspector prior to starting this one and verbally got the approval. The meter portion has to be able to be locked and obviously the 5th jaw.
@richardwesley36015 ай бұрын
Nice video love watching your videos learning alot
@chriskelvin2483 ай бұрын
Folks were knocking the HacksAll, but lo and behold, it can be both small AND get some rough work done.
@bigtroll82495 ай бұрын
Whats the max. distance for straps on each side of the compression coupling? 12 inches?
@electricianron_New_Jersey5 ай бұрын
NEC 344.30 RMC shall be securely fastened within 900 mm (3 ft) of each outlet box, junction box, device box, cabinet, conduit body, or other conduit termination.
@bigtroll82495 ай бұрын
@@electricianron_New_Jersey hmmm... But a coupling doesnt seem like a termination.. its more like a splice. So maybe 18" on each side of coupling?
@jwardcomo5 ай бұрын
Really enjoyed the video. Thanks!
@DavidKingmasterWV5 ай бұрын
Your the best Ron
@electricianron_New_Jersey5 ай бұрын
✌️
@GeorgeProto-u1e22 күн бұрын
Very nice
@MrJujubean5 ай бұрын
You do great work!
@johnmazzocchi71165 ай бұрын
I think you should contact the Milwaukee rep!! He should notice the I side of your truck 😅😅
@jimcasey64605 ай бұрын
Nice job!
@AwakenTheLost4 ай бұрын
This is awesome to see! Could you say what the price range is for this type of electrical job? Apprentice electrician aspiring to have my own business one day!
@AAAElectriqueInc4 ай бұрын
Hello Ron. Question for you from Canada. I noticed you had to extend your rigit conduit by 2 feet with another rigit. Couldn't you extended with 2 inch PVC conduit using the transaction attachment between rigit to pvc?
@AAAElectriqueInc4 ай бұрын
Transition.
@electricianron_New_Jersey4 ай бұрын
No. There’d be no reason. To do that.
@mamer84864 ай бұрын
What's the Model number for this pse&g approved Eaton service meter/disconnect combo, thank you.
@luislazogue80895 ай бұрын
Is that gas meter over 3’ of your service? I can’t tell by the video.
@electricianron_New_Jersey5 ай бұрын
Why, are you worried about it? It's fine.
@luislazogue80895 ай бұрын
@@electricianron_New_Jersey the service should be no less than 3’ of the gas meter, I’ll find the code reference later today.
@luislazogue80895 ай бұрын
@@electricianron_New_Jersey I don’t remember if is in the NEC or PSEG book.
@luislazogue80895 ай бұрын
@@electricianron_New_Jerseyfound it, is a PSEG requirement, It’s in the page 10-16 note 9 of the PSEG book.
@cdfornalАй бұрын
How do you get away with #6 GEC on a 200A service ?
@lancewolf24515 ай бұрын
Should have stabilizing bar for the ladder so the gutter ( aluminum) doesn't get dented
@electricianron_New_Jersey5 ай бұрын
Good point, but did you see how strong those gutters were? They were really nice.
@Precocktrigger5 ай бұрын
Nice Great Video
@shahrampooee98312 ай бұрын
whats the model number of panel?
@stephenwhiteley67865 ай бұрын
Just did a 200 amp on a 80 year old factory. Looked at 80 year old switch gear. Rusted as hell talked owner into a brand new service
@walkerhite24062 ай бұрын
Where can I find that meter base combo?
@electricianron_New_Jersey2 ай бұрын
supply house
@walkerhite24062 ай бұрын
@@electricianron_New_Jersey what is the meter base called? Just a meter shut off combo? Thank you.
@walkerhite24062 ай бұрын
@@electricianron_New_Jersey hey man wondering if you could tell me what to tell this meter is called thank you
@TimboStang715 ай бұрын
Looks great ron, i know that crawl space blew. Still teaching at those classes??
@electricianron_New_Jersey5 ай бұрын
Yup. Next weekend I'll be in Laurel, Md., for an IEC instructors conference at IEC Chesapeake. I'll be teaching year one again starting in the fall.
@garycunningham84785 ай бұрын
I always do 3 feet at the weather-head
@clearviewtechnicalАй бұрын
Those lag screws are NOT 1/2". Screws and bolts are sized by their shank diameter. So they may be #12 or 1/4" or 5/16" etc. The hex head is considerably larger than the shank and I'm guessing yours had a 1/2" (across flats) hex head wrench size.
@electricianron_New_JerseyАй бұрын
@@clearviewtechnical 9/16
@BearStar15 ай бұрын
'' RMC '' , Rigid (Galvanized) Metal (Steel) Conduit !!
@wirenut90624 ай бұрын
Just had an inspector in Bergen county break balls about using a 2 inch LB for 200 amp SER. " I'll let it go but next time it has to be 2 1/2" really dude?
@electricianron_New_Jersey4 ай бұрын
@@wirenut9062 tell him to pound sand unless he has a code reference for the DCA.
@kangaroogod5 ай бұрын
👍
@mackfisher44875 ай бұрын
You don't need a membership in a health club jest perches a fiberglass ladders.
@DougLockard5 ай бұрын
Dude hire some help...save your back
@ThermoCoupleNZ5 ай бұрын
how do you stop water coming down the mast and into the box?
@electricianron_New_Jersey5 ай бұрын
@@ThermoCoupleNZ with a weather head!
@ThermoCoupleNZ5 ай бұрын
@@electricianron_New_Jersey that will teach me for commenting before watching the whole video! great work Ron!
@cdfornalАй бұрын
How do you get away with #6 GEC on a 200A service ?
@electricianron_New_JerseyАй бұрын
@@cdfornal because #6 AWG copper is all that’s ever required for connecting ground rods. 250.53 (E) Supplemental Electrode Bonding Connection Size. Where the supplemental electrode is a rod, pipe, or plate electrode, that portion of the bonding jumper that is the sole connection to the supplemental grounding electrode shall not be required to be larger than 6 AWG copper wire or 4 AWG aluminum wire. THAT’s how I “get away with it” by doing it right the first time.
@cdfornalАй бұрын
@ sorry that came out wrong. I missed the “supplemental” part Your primary ground is sized according to 250.66 right? Usually I’d just run a continuous piece of #4 cu from the panel to two ground rods even if there is a cu water line. This is because most everyone is pulling out or splicing the copper - so we know the two rods should be fine for at least 20 years