Electricians get THIS type job over the festive period...

  Рет қаралды 11,523

Eastway Electrical

Eastway Electrical

Күн бұрын

Пікірлер: 30
@weeniebeastie
@weeniebeastie 9 ай бұрын
Story time with Del on his electrical stool is a win for me. Maybe you could do some more of these, telling stories of previous jobs over the years while wiring plugs, adding ferrules etc
@djdanny9000
@djdanny9000 3 ай бұрын
I love watching your videos very fascinating and educational I love technology and I love your videos
@dj6596
@dj6596 9 ай бұрын
Their should be a 45amp double pool switch between the CU and the cooker cable point. I would have used the dedicated circuit and use a double cooker cable point and connected both the cooker and hob together in the double cooker cable point. 45amp fuse. 45amp - 10amp = 35amp 30% x 35amp = 10.5amp 10.5amp + 10amp = 20.5 amp If there is a single socket on the isolator then add 5amp to the result. on-site Guide Appendix A page 136 brown book keep them coming Del, love your video. one brother to another.
@StevenOBrien
@StevenOBrien 9 ай бұрын
I once had to track down a faulty bulb on a wire of Christmas lights. I'm something of a festive electrician myself.
@Imakeelectronicchaos
@Imakeelectronicchaos 7 ай бұрын
I do that every December lol
@leeroberts1192
@leeroberts1192 8 ай бұрын
When I had my oven replaced (single to replace a single), I had the option of having it on the kitchen ring but I opted to have the oven and the hob together on their own circuit, with a local isolator switch by the oven.
@HeathenGeek
@HeathenGeek 9 ай бұрын
you're right, for ovens greater than 2kW, they shouldn't be plugged into the kitchen ring, they should have a dedicated circuit. However, this dedicated circuit can be the same circuit as the hob, so the 6mmsq cable that was there could have done BOTH the oven and the hob. You can buy dual cable outlet plates (elephants noses / cooker faceplates, whatever some people call them) from CEF and other places specifically for hardwiring in both. There's no requirement for local isolation for cookers in the regs now, maybe just best practice, but if an isolator is fitted, building regs say it should be within 2m of it.
@amac1657
@amac1657 9 ай бұрын
I’m sure you’re right about the isolating switch. In the event of the oven being on fire or repair or maintenance work needs carrying out it is convenient/ safer to isolate that part of the electrical network before touching the appliance.
@CommercialGasEngineerVideos
@CommercialGasEngineerVideos 9 ай бұрын
Thanks for sharing your experience
@gdexterc
@gdexterc 9 ай бұрын
4mm has always been rated for 32A, there's a reason we're OTT, Safety
@phillallen01
@phillallen01 9 ай бұрын
We used to always supply a single cook supply of its own back in the day and we used to use 10mm on a 32 amp fuse surely pluging that into a ring is going to overpower the circuit
@lotuselise4432
@lotuselise4432 9 ай бұрын
@@mrfixit0273 - Lots of tin foil rolled up on a 6 inch nail............
@tonywatson1412
@tonywatson1412 9 ай бұрын
Why 10 mm. ? Then fused at 32 amp...
@lanceeaton2812
@lanceeaton2812 9 ай бұрын
I was of the understanding diversity is only used to determine the size of cable and fuse supplying the whole installation ie 100A fuse for a home? The cable supplying the cooker should be rated to full load current of the appliance.
@gezmonder
@gezmonder 9 ай бұрын
We'll call this piece "Musings whilst wiring a plug".....
@AnthonyChopra
@AnthonyChopra 9 ай бұрын
id prob want isolator switches for all high powered items.
@HA05GER
@HA05GER 9 ай бұрын
Ahhh john ward love his videos
@stepbackandthink
@stepbackandthink 5 ай бұрын
Biggest problem with time served sparkies is their insistence on hanging stinky string switches in bathrooms. Just put a normal switch in where it’s out of zone ffs.
@mattFreya
@mattFreya 7 ай бұрын
Hope you’re doing ok Delroy. Are you planning any further videos anytime soon?
@audibell
@audibell 7 ай бұрын
Nice job
@robertpeters8531
@robertpeters8531 9 ай бұрын
Good video Thankyou
@maicod
@maicod 9 ай бұрын
Is the reason UK requires isolation switches the fact there's Ring Circuits while in for instance Netherlands all is Radial ?
@johnb.9190
@johnb.9190 9 ай бұрын
Hi,there is no regulation that requires an isolator for an oven/cooker providing it can be locked off at the mcb/rcbo at the consumer unit,as Del was saying we do things because we were taught that way.A few years ago I was wiring a kitchen with a glass backsplash and nowhere for isolator’s so I rang the NICEIC helpline to find out what I had done for over 35years was just good practice.
@maicod
@maicod 9 ай бұрын
@@johnb.9190OK yea good practice is always nice ! I was more refering to the general wall sockets in the UK that have a switch on them. I was suddenly thinking is that cause these wall sockets are in a ring circuit and otherwise you'd need to cut the whole ring at the fusebox to isolate one of the ring's sockets? here in Netherlands we have no wall sockets with switches but we use Radial circuits afaik (I'm not a sparky myself but doing hobby electronics (low voltage))
@chas3997
@chas3997 8 ай бұрын
Best to think of the idiot that could move in and mess with it ,therefore use 6mm cable & double pole cooker isolator on an RCD protected circuit.
@ianbaulk9766
@ianbaulk9766 9 ай бұрын
Should of been wired into a fused spur
@sidtariq6176
@sidtariq6176 9 ай бұрын
Single ovens only need a plug lol
@Dazzy84
@Dazzy84 9 ай бұрын
Diversity is your friend.. had to use it a few times myself.. 👍
@stuartlane141
@stuartlane141 9 ай бұрын
Diversity is not your friend. Belt and braces is always the way forward. Why skimp on copper to give yourself peace of mind. I totally disagree.
VOLTAGE DOWN THE NEUTRAL CAUSING LED PROBLEMS AND EARTHING ISSUES
25:55
Eastway Electrical
Рет қаралды 29 М.
Ozoda - Lada ( Official Music Video 2024 )
06:07
Ozoda
Рет қаралды 28 МЛН
Стойкость Фёдора поразила всех!
00:58
МИНУС БАЛЛ
Рет қаралды 7 МЛН
Good teacher wows kids with practical examples #shorts
00:32
I migliori trucchetti di Fabiosa
Рет қаралды 12 МЛН
Why I Left The UK & How Much It Costs To Move And Live In Cyprus! 2024
20:25
“Why Would A Spark Do Something So Stupid”🤦‍♂️
19:46
Eastway Electrical
Рет қаралды 51 М.
Intermittent Tripping: These Faults Are The Hardest To Finds
12:49
Eastway Electrical
Рет қаралды 20 М.
The REAL Problem with Smart Meters
20:05
RECESSIM
Рет қаралды 578 М.
FIRST RIDE: Tesla Robotaxi - Our Driverless Future Has Arrived!
24:58
🤦🏿‍♂️ I Thought This Was Going To Be A Simple Job...
22:06
Eastway Electrical
Рет қаралды 18 М.
Electrician's Job In A Pub Goes Wrong...
17:42
Eastway Electrical
Рет қаралды 18 М.
"They've Used Blu Tack To Hold This Up!!" | This Must Be DIY
19:28
Eastway Electrical
Рет қаралды 41 М.
Ozoda - Lada ( Official Music Video 2024 )
06:07
Ozoda
Рет қаралды 28 МЛН