⚠️ Electricians Warned Over Neutral Current Diversions ⚠️

  Рет қаралды 4,066

eFIXX

eFIXX

Күн бұрын

Пікірлер: 66
@christastic100
@christastic100 2 сағат бұрын
So what we are saying is the network providers who receive millions per week in standing charges , who don’t conduct any periodic testing until a failure happens, who get waspy about what goes in your meter box, who have in part a decrepit network in many areas now expect us Electrical contractors to watch out for the problem and dangers they are responsible for. Oh right
@andysims4906
@andysims4906 Сағат бұрын
I used to work with a guy years ago . On any new installation he would never use the PME terminal. He would always install an earth spike and additional RCD . In his opinion it was much safer that way .
@grahamheath9957
@grahamheath9957 3 сағат бұрын
I really don’t understand why we don’t also put in a back-up earth spike for all installs to avoid PEN fault related issues. I just don’t see why that would have any negative consequences fro end users or the DNO
@retrozmachine1189
@retrozmachine1189 4 сағат бұрын
It's weird to me that a country that has implemented TN-C-S to some degree for a long time now needs to issue special warnings and guides to electricians about how to work with it. Is something lacking in training? I think we've all seen that clip where a UK electrician interrupted earthing without so much as a whiff of checking current flow before doing so.
@efixx
@efixx 2 сағат бұрын
The network's getting a bit creaky in the UK. 😬
@MS-Patriot2
@MS-Patriot2 Сағат бұрын
@@efixxall the more reason to push more EV and heat pump roll out!
@paulentwistle6343
@paulentwistle6343 4 сағат бұрын
Why is it that the consumer has to pay the price to put the DNO right? SPDs etc, using aluminium overhead cables within 25 miles of the sea ( we live on an island?)is not supposed to happen, no wonder pen conductors are corroding, premature collapse regs when you get The low voltage boys (failed mains sparkys) doing whatever they like. Courses to fit fans when it is still allowed by the DIY merchants. Thank God I retire very soon! At least with no winter fuel allowance I can burn the hundreds of pounds worth of regs books etc I own for warmth!
@efixx
@efixx 2 сағат бұрын
Thanks for commenting!
@anthonyjones5711
@anthonyjones5711 3 сағат бұрын
Such a brilliant idea to bond on the installation (consumer) side of a gas meter full of explosive gas that could potentially have large diverted neutral currents flow through it in the event of an open PEN fault.
@olly7673
@olly7673 5 минут бұрын
It would not surprise me to hear the next amendment introducing the requirement to install a PEN Fault Detection device either alongside an old CU or as part of a CU change, as the amount of incidences increases and the issues brought more into mainstream media outlets. Manufacturers who are early adopters to miniaturise them to go in a spare way or two will do well.
@sibrown
@sibrown 4 сағат бұрын
We had our own PEN fault on the 1st of October. Was unsure initially what was wrong when we had a flickering supply, a high Ze result (with parallel paths connected) led me to alert UKPN but I didn’t continue with further testing (as I had work to go to) to discover what actually was going on
@efixx
@efixx 2 сағат бұрын
Great insight, thanks for commenting! 😃
@G1ZQCArtwork
@G1ZQCArtwork 2 сағат бұрын
I know PME is very much country wide, but, as it is proving to be so unreliable, why can't they mix PME with bonded TT.?? That way if the Neutral went down, the system would still be protected to some degree with an Earth Spike.! If every property had an Earth Spike back to the transformer more breakers would trip in the properties... Saving lives and unwanted shocks. I have TT here and would not be without it. Someone be brave and tell me why we can't bond the Neutral to a spike.!?? Bearing in mind, I have done loads of work on camping sites.....
@andyb7813
@andyb7813 2 сағат бұрын
That was my question too
@G1ZQCArtwork
@G1ZQCArtwork 2 сағат бұрын
@@andyb7813 To be honest, as a PEN fault is so dangerous, I would have thought by now, it would be Mandatory to back up the system with TT Earth Spikes as a matter of good practice and for much better safety. All Camping sites, Marinas and I think most rural Farm outbuildings are all TT for that very reason. Some older properties do not have any form of RCD in place, so an Earth Neutral fault in the property would never show up unless specifically looked for during "inspections" which are hardly ever carried out in some places.
@Edro-oh5ku
@Edro-oh5ku Сағат бұрын
cant undrestand why not installing , earth rod in addition to PEn, why does it have to be a single arrangement TN or tncs.. , i suggest TNCS-TT , thats it
@Dog-whisperer7494
@Dog-whisperer7494 2 сағат бұрын
I hope the guys who invented the electricians diary got written permission from the IET to use their charts as the IET owns the copyright of those charts.
@craigadams650
@craigadams650 4 сағат бұрын
Clearly will be another addition in regs to add an additional rod on all tncs installs.
@efixx
@efixx 2 сағат бұрын
It's already mentioned in there. 🤔
@markrainford1219
@markrainford1219 52 минут бұрын
I'm going barking here. I thought they introduced it for all new builds or did they revoke it, or am I information overloaded?
@walrus10001
@walrus10001 3 сағат бұрын
Select download link does not seem to work….. page not found 😮
@efixx
@efixx 2 сағат бұрын
Hm, we'll have a look at it. 👍
@frodev728
@frodev728 3 сағат бұрын
ℹ️ the flow chart link is not clickable like the other links are. could you fix that please
@efixx
@efixx 2 сағат бұрын
Thanks for the heads up we'll have a look at it. 😬
@frodev728
@frodev728 Сағат бұрын
@ 🙏
@steve11211
@steve11211 3 сағат бұрын
I wonder is it time that Electrical work is diversified so that you have specific electrical sub jobs for example Electrician - Solar/Battery, Electrician - Mobile generation etc etc.. So you get your electrical qualification then you can specialise in certain areas and become a certain type of electrician..
@efixx
@efixx 2 сағат бұрын
Could be.... 😬
@markrainford1219
@markrainford1219 44 минут бұрын
Electrical work itself is not complicated. It's the damned regulations that's complicated.
@SmithyScotland
@SmithyScotland Сағат бұрын
Good to see your script writer has found a map.
@arcadia1701e
@arcadia1701e Сағат бұрын
Adding an earth rod to TNCS systems is already in the regs btw, seems no one knows this?
@retrozmachine1189
@retrozmachine1189 53 минут бұрын
It's not mandatory though? It's another odd thing really, other countries with TN-C-S type systems have had mandatory dedicated electrodes for decades yet over there it's still only recently become recommended.
@thedon7536
@thedon7536 2 сағат бұрын
FLOW CHART WAS WRONG FROM THE START, KETTLE FOR TRA SHE BE CHECKED FIRST 👏👏👏👏👍👍👍👍😂😂😂😂
@norbertkajubiee1399
@norbertkajubiee1399 4 сағат бұрын
Just remembered my weekly price that i never got 😢
@efixx
@efixx 2 сағат бұрын
Hi Norbert, I'll get in touch with our shipping department and see what we can do. 😬
@timhull8664
@timhull8664 4 сағат бұрын
Well soon have to bend enough earth rod to reach the consumer unit .. 😮
@efixx
@efixx 2 сағат бұрын
😂
@markrainford1219
@markrainford1219 42 минут бұрын
Spiffing idea old chap.
@bitmanev4331
@bitmanev4331 26 минут бұрын
And then still saying the UK Electricity System is the best "in the world"
@Jasonf-km5mq
@Jasonf-km5mq 56 минут бұрын
Draconian, buzzed
@gfy2979
@gfy2979 55 минут бұрын
Fury and Eskimo
@Jasonf-km5mq
@Jasonf-km5mq 59 минут бұрын
Draconian, Bentley
@ianbird4737
@ianbird4737 Сағат бұрын
Eskimo and Buzzed.
@glenwoofit
@glenwoofit Сағат бұрын
Bentley Eskimo
@MustafeFarah-f3n
@MustafeFarah-f3n 2 сағат бұрын
New
@mark_just_mark
@mark_just_mark 4 сағат бұрын
Draconian and Eskimo ❄ (aasuming there are two this week... 🧐 )
@efixx
@efixx 2 сағат бұрын
There definitely are Mark, I promise! 😃
@hasan2471
@hasan2471 3 сағат бұрын
Bentley and Eskimo
@efixx
@efixx 2 сағат бұрын
Bet you've never typed those in a sentence before.... 🤔
@Fitness_bary
@Fitness_bary 5 сағат бұрын
I will be electrician soon inshallah
@efixx
@efixx 4 сағат бұрын
Nice! Keep up the good work. 💪
@thattoolguy9432
@thattoolguy9432 3 сағат бұрын
Rolec and Futureproof ..... 🤣🤣🤣🤣🤣
@efixx
@efixx 2 сағат бұрын
Nice guesses Torchy, how are you doing? 😃
@thattoolguy9432
@thattoolguy9432 2 сағат бұрын
Better now ive left the industry.. hows you
@TheRoss140
@TheRoss140 3 сағат бұрын
I reckon one word was Draconian & Eskimo ?? joe knows how to pick his words haha
@efixx
@efixx 2 сағат бұрын
Ooh, or is one of them a red herring? 🤔😃 Find out on Monday! 😊
@davefrizelle3882
@davefrizelle3882 3 сағат бұрын
Hi there, my guess for the words this week ... draconian and eskimo.
@crazycruff
@crazycruff 4 сағат бұрын
Eskimo and Ice cream
@efixx
@efixx 2 сағат бұрын
Great guesses, listen to next Monday's show to see if you're right! 😃
@colinblythe3710
@colinblythe3710 Сағат бұрын
You are NOT allowed to say ESKIMO anymore - its racist - so I have been informed !! You can't say Aboriginal either NOT a word is said when an English person is called a BRIT Racism only works one way !!
@kevinhenryviii
@kevinhenryviii 4 сағат бұрын
Eskimo and ice cream
@efixx
@efixx 2 сағат бұрын
Nice guesses Kevin, definitely two words in this week... 😬
@Bari_Khan_CEng_CMarEng
@Bari_Khan_CEng_CMarEng 3 сағат бұрын
Draconian, Eskimo
@efixx
@efixx 2 сағат бұрын
Nice guesses, listen to next Monday's show to see if you got it! 😊
This Fault DEFEATED Multiple Electricians! Can We Fix It?
17:31
Artisan Electrics
Рет қаралды 5 М.
Симбу закрыли дома?! 🔒 #симба #симбочка #арти
00:41
Симбочка Пимпочка
Рет қаралды 6 МЛН
Long Nails 💅🏻 #shorts
00:50
Mr DegrEE
Рет қаралды 19 МЛН
Quilt Challenge, No Skills, Just Luck#Funnyfamily #Partygames #Funny
00:32
Family Games Media
Рет қаралды 43 МЛН
Beat Ronaldo, Win $1,000,000
22:45
MrBeast
Рет қаралды 78 МЛН
Deutsch - my new favourite rugged connector
15:13
bigclivedotcom
Рет қаралды 29 М.
Stellantis CEO Carlos Tavares FIRED as US sales crash
11:22
The Electric Viking
Рет қаралды 49 М.
Family Deaths Linked To DIY Wiring
12:32
eFIXX
Рет қаралды 12 М.
Why Should You be an Electrician? - EU On the Road
13:46
Electrician U
Рет қаралды 48 М.
90% of Toilets Are Installed Wrong (Here’s the Right Way)
16:04
Home RenoVision DIY
Рет қаралды 1,8 МЛН
Driving The Stelvio Pass In Supercars | Top Gear Classic
14:07
Top Gear Classic
Рет қаралды 16 М.
I never understood why you can't go faster than light - until now!
16:40
FloatHeadPhysics
Рет қаралды 4,1 МЛН
Симбу закрыли дома?! 🔒 #симба #симбочка #арти
00:41
Симбочка Пимпочка
Рет қаралды 6 МЛН