THREE WAYS 3-WAYS CAN BE (3way Switch Wiring - ILLEGAL AND LEGAL METHODS)

  Рет қаралды 430,286

Electrician U

Electrician U

Күн бұрын

Пікірлер: 757
@Ibuildit2817
@Ibuildit2817 8 ай бұрын
THIS was exactly what I was looking for! We recently did a simple switch disconnect/reconnect but I was trying to wire the traditional way but as it turns out, we were dealing with a Dead End 3-way. totally confused me. We did finally figure it out but this explains so well why 99% of 3-way wiring videos out there do not show dead end wiring. THANKS! I needed this!
@khybersafi9137
@khybersafi9137 3 жыл бұрын
Here's a future video idea: How to do a re-wire or replace a home-run most efficiently with minimum amount of drywall damage. Any tips and tricks you've learned over the years that would be helpful to new guys getting into the field. Thanks.
@glennreynolds962
@glennreynolds962 3 жыл бұрын
Depends on what is above or below and where you can fish from. Sometimes you have to go up over and down. I worked in a split level that had the walls been open would take 50 ft of wire from the panel to new AC. Because we had to drill and fish up over and down it took almost a full roll of 10/3 NM
@305liveandlearn
@305liveandlearn 3 жыл бұрын
I would love to see a video about this uuf
@TheChadavis33
@TheChadavis33 3 жыл бұрын
Agree. I’m always wanting to do the minimum amount of damage, and obviously still get the job done quickly and efficiently
@rileybolling761
@rileybolling761 3 жыл бұрын
This would be tremendously helpful.
@tay13666
@tay13666 3 жыл бұрын
I can tell you that re-wiring without opening the walls uses a whole lot more wire. You can't do it efficiently without opening up walls. If you don't open walls you use lots of junction boxes in the basement and attic, and a lot of dead end runs. But that is the trade off for not damaging original plaster in an 1890 house. First floor isn't as bad if you have a basement, not nearly as much wasted wire going from underneath to wall outlets. Going up to the attic, then dropping down the wall for each receptacle on the second floor burns through wire pretty quick though.
@dakotagarcia3772
@dakotagarcia3772 3 жыл бұрын
The Code Time segment really sets this channel apart. I feel your channel is very underrated and want to say thank you for inspiring me in part to persue this career!
@JmanRx81
@JmanRx81 Жыл бұрын
Indeed!
@ChuAlready
@ChuAlready 3 ай бұрын
Hes the real deal, very knowledgeable and comes with facts!
@warrennetherton6011
@warrennetherton6011 25 күн бұрын
Explained well and cited code from the book. I was trying to figure out wiring a dead end 3-way. Your explanation was clear and you explained conditions or concerns of doing this. Thanks for the video.
@dannyrondeau7873
@dannyrondeau7873 3 жыл бұрын
Can I double thumb up this vid? It took me an hour to figure out a repair on a dead end threeway last month. One of the switches had died, but seeing that hot neutral in the light box with no ID tape on it left me so confused until I drew it out on the table. Your video makes it so clear so quickly. Great info!
@imdeplorable2241
@imdeplorable2241 3 жыл бұрын
BINGO!! It was a "Chicago 3-way" design. While merely replacing an old 1920s porcelain 3-way in a friend's 1905 house, I blew 4 Edison base fuses. What the...? So, I had to run a wire from a water pipe to determine what wires were hots or neutrals using my Wiggy. Yes, there was a neutral (!!??) on the switch. NOW I KNOW WHAT WAS GOING ON THERE. "Chicago 3-way." Thank you so much for this tutorial. Neither of those systems was taught in my apprenticeship.
@richaw42
@richaw42 2 жыл бұрын
When I was a kid, my father replaced a 3-way switch, and as soon as we flipped the switch, it blew the fuse! Huh? Well, it was (as I now know) a Carter 3-way, and the replacement switch was a mercury switch, and flipping the switch momentarily connected all three terminals, shorting the power, and blowing the fuse! Minneapolis, not too far from Chicago :)
@sambulate
@sambulate Жыл бұрын
Dude, thank you SO much for this! The way you've animated this, and how you've illustrated the connections are SO helpful. The physical connections and interactions between the components are what I have struggled with, and this helps me visualize it better than I ever have. More, please!
@juanlorenzo7341
@juanlorenzo7341 3 жыл бұрын
im a journeyman electrician , i know this stuff but for some reason i cannot stop watching your videos, thank you for the videos your doing keep up the great work
@vlad1889
@vlad1889 3 жыл бұрын
IS NEC certified same as Journeyman? Taking exam at your local village or other local jurisdiction but it just states licensed electrical contractor not journeyman. So journeyman is specifically for union electricians?
@jimmac1185
@jimmac1185 3 жыл бұрын
@@vlad1889 Nope, where I live there is 4 classes of electricians, licensed by our state, union or not. Class A: Master Class B: Journeyman Class C: Systems Contractor Class D: Systems Technician I currently hold a Class A and B licenses, since for some reason your not actually allowed to do electrical work with s Class A. Weird huh?
@steve-o6413
@steve-o6413 3 жыл бұрын
@@vlad1889 state licensed for general electrical contractor is the same as journeyman...
@johnsandlinjr
@johnsandlinjr 3 жыл бұрын
@@steve-o6413 in DE a journey needs to work under a master still. Only a master can pull a permit.
@jeromewilliams4516
@jeromewilliams4516 3 жыл бұрын
I only see this NEC 2020 "neutral at switch boxes" applying to completely new switch circuits as in a rewire or new construction. As a practice, I try to always (especially in residential) have my switch legs go up to a fixture outlet from a wired switch box rather than than down. and this practice was influenced from my early electrical maintenance days (mostly service work), whereas I hated having to fool with a light fixture to troubleshoot a problem such as bad splices. Another great video for sure...
@newenglandman2413
@newenglandman2413 3 жыл бұрын
You just solved a 29-year mystery in my world. It was that long ago that I was unable to figure out the wiring of a 3-way switched light in an old house retrofit with K&T (had been gas lit) that had then been plastered-over. For the love of God nor money could I figure this thing out. Of course, I could not see the wiring paths behind the walls and all wires were the same color black. It was, I see now, a Chicago/Carter method. Thank you.
@jurassicsparks5220
@jurassicsparks5220 3 жыл бұрын
Ok, so terminology is different as I’m a licensed Electrician in both Australia and UK. But the first 3 way and the dead end 3 way is generally what we would use… the dead end is wired slightly differently but the principle is the same. Enjoying your vids and the different words we use.
@joshuaarellano6600
@joshuaarellano6600 3 жыл бұрын
Would you mind recommending some electrical channels similar to this from one of those countries? I'm interested on learning more about how things are wired in a 240v system.
@jurassicsparks5220
@jurassicsparks5220 3 жыл бұрын
@@joshuaarellano6600 Check out Artisan electrical and Tom Nagy
@Turbo.M777
@Turbo.M777 2 жыл бұрын
I was going nuts trying to figure out how to replace a three way switch setup in my house. It didn’t make sense looking at how the existing wiring was. Until I found this video! apparently it was a “cali” three-way. Thanks!
@martytruelove5026
@martytruelove5026 2 жыл бұрын
He is a Great Teacher...understandable explanations.
@youdontknowme5969
@youdontknowme5969 3 жыл бұрын
Perfect timing!! I encountered a strange 3-way delimma over the weekend at a 90 year old house. I bet it's a Chicago 3-way...
@Roy-ij1wq
@Roy-ij1wq Жыл бұрын
Great video. You just helped me solve a problem I was working on today with two dead end 3 way switches that control the garage light from the kitchen door and garage door. Saved me the trouble of having to call for help. Update - Section 404.2c was changed in 2020 and now prohibits a "dead end" three-way in a remodel if there is no finish on the wall and the wire is readily accessable and can be changed. I ran into this on my remodel when I exposed an old dead end three-way and had to add a neutral. The reason for this is that many modern "smart" switches require a neutral. If the neutral isn't used, it is capped for future use. I'm also having to upgrade some single pole switches to 14/3 wire because the home runs are to the junction box for the light. Again, the unused neutral is capped for future use.
@timlabarr6131
@timlabarr6131 3 жыл бұрын
Totally thought this was gonna be another repeat video. BUT It wasn't that's awesome because I didn't know about the Chicago 3 ways or the Cali 3 way really except that Kelly 3 ways were dead in 3 ways as well. Thanks for the knowledge dude and nice animations.
@chris2884
@chris2884 Жыл бұрын
Love your video and have come back several times to watch the variations. One variation of the three-way switch I’m having a really hard time finding is one where the power comes into the switchbox, and then both the three wire to the other switch, and the two wire to the lights come out of that same box. Might be a great video for someone as I can’t find it anywhere
@Sparky-ww5re
@Sparky-ww5re 11 ай бұрын
What you're describing is the dead end three way, actually a commonly used variation. Technically still a code compliant 3-way since the box with the incoming power has an available neutral. Especially useful in renovations where you need to convert a single pole switch into a pair of 3 ways with minimal work.
@benjaminhoskins5733
@benjaminhoskins5733 Жыл бұрын
This video answered a lot of my questions. The white board and diagrams made it simple. Much appreciated.
@tadonplane8265
@tadonplane8265 Жыл бұрын
An old electrician who wired many California three way circuits explained it to me like this. On a three way switch you have a common and two throws, not a common and two travelers. The wires are travelers not the terminals. A traveler is a wire that connects two switches together and no matter how many boxes that wire goes through nothing else gets connected to it. A conventional three way (straight, loop, dead end) has two travelers. A California has one traveler between the commons, nothing else is connected to that wire. While the throws are wired together too, those conductors are not travelers because in every box they go through, one is a hot and the other is a switch leg. In a Carter there is no traveler. Each switch gets hot and neutral on its throws and the lamp is wired between the commons. It’s illegal because it can break the neutral leaving both sides of the lamp shell hot, with the lamp being off. The benefit of the California is when a three way is needed to control a string of lights, it saves a conductor in the run compared to a conventional three way. It’s totally legal under 404.2 because it only breaks the hot. Save yourself some wire, use the California when you have multiple loads on a three way.
@eldenboy11
@eldenboy11 2 жыл бұрын
This was soo helpful. I just found out about the neutral code requirements and wasnt sure, about how to handle until watching this video. Thank you!!
@Sparky-ww5re
@Sparky-ww5re 2 жыл бұрын
Can be especially confusing for traveling electricians because often local jurisdictions have stricter requirements than the NEC and while one county for example, may allow dead end three ways, the next county may not, or they may allow 14-4 or two runs of 14-2 so as to have a neutral at all switch boxes, for example.
@comingtofull-ageinchrist6736
@comingtofull-ageinchrist6736 2 жыл бұрын
basically, if you are running Romex, then the neutral needs to be in the outlet box. If it's EMT, and you can add it later then you don't have to run it; it can be added later if it's needed. This is basically why, in Oklahoma, they stopped letting us use the white wire to send a switch leg to the other 3 way and mark it with some red tape to identify it as hot. As an apprentice in open shop, I worked with a Journeyman that liked to use the white wire in a 12/3 to send the switch leg to the other side. He argued it uses less wire and saved on overhead. People were calling that a California 3 way for years until we had an electrician from California come along and tell some people that this wasn't a California 3 way. This is the first time I ever seen someone describe a California 3 way, and it is definitely different from what Journey were calling one back then. I have never seen the Carter 3 way but that looks kind of sketchy! I wonder who dreamed that up?
@Sparky-ww5re
@Sparky-ww5re 2 жыл бұрын
Jimmy Carter lol😂😂
@darbyl3872
@darbyl3872 2 жыл бұрын
I just checked the NEC Handbook (2017), Article 200.7(C)(1). Another commentor is correct. For cables (MC, Romex), the white wire can be used and re-identified as ungrounded, if a switch supply or traveler in a single pole 3-way / 4-way switch loop, but not a switch leg. Interestingly, it doesn't prohibit all switch legs from being white wire (from a cable). Some people will say the switch leg should never be white, but that's not in the code (2017).
@Sparky-ww5re
@Sparky-ww5re 2 жыл бұрын
Also the white wire can be used and re-identified as a hot, when used to power a straight 240V load, such as a water heater, baseboard heater, or a NEMA 6-20R typically used for larger window AC units and larger electric heaters.
@darbyl3872
@darbyl3872 2 жыл бұрын
@@Sparky-ww5re Yep, if it's cable.
@fdMT_EnGy
@fdMT_EnGy 2 жыл бұрын
Ok, this might seem like a dumb question and you might have mentioned it. In the first example, how would you run the ground? I've seen two ways. Coming from the panel, bypass the outlet and switch, straight to the fixture, then from the second switch to the fixture. Basically just one continuous wire from the panel to the fixture, grabbing a tail from the second switch. The second way I've seen is from the panel meeting up with a tail from the outlet and each switch then up to the fixture. So basically grounding everything along the way to the fixture. I hope that all makes sense.
@danan9037
@danan9037 10 ай бұрын
I really learn a lot from your vids and appreciate your producing them. Great explanation of three ways. Another way to wire a dead end 3-way and have a constant hot and neutral in the leg box is using 12-2-2 or 14-2-2. Method: From the line-side, send the hot (black) to the load (black screw) of the leg switch. Use the red and red/white conductors for travelers and cap off the neutral (for future). In the line-side box, connect the light's black wire (load) to the load post (black screw) and splice your neutrals there. We had to do this where we had a huge barring post in the way making other paths difficult.
@golgothingaming4719
@golgothingaming4719 2 жыл бұрын
Dustin I need your help. I believe I have a dead end 3 way in my kitchen (house built in 1952) I am putting a light fixture and dimmer in my living room. I put the dimmer on the opposite side of the wall where my kitchen light switch is (suspected dead end 3 way with no neutral wire). So I want to run power from the dead end switch to the dimmer. My 2 problems are 1. I'm having a hard time finding out which is power and 2. since there is no neutral in the dead end box where do I tie the neutral from the new light? I understand you are a busy person so I'm hoping you can help me. Love your videos and your channel! You have taught me so much and gave me the confidence to tackle these jobs on my own as I can not afford to call an electrician out. Thank you
@andycopeland7051
@andycopeland7051 3 жыл бұрын
Fantastic video brother! Learned a lot about the two odd-ball wiring methods. Your animations were perfect. Thanks a lot man keep it up
@aristotle56
@aristotle56 2 жыл бұрын
The 'Dead End 3-Way' is what I would use based on my 45 years in electronics, though I would run the 14/3 red & black from the travelers on the first hot switch plus the neutral straight into the ceiling box, then strip off the outer jacket, cut the white wire and fasten it onto the shell screw, then put black tape onto the other end of the white and connect it to the screw hooked to the bottom light socket contact. Then I would continue the cable over to the other 3-way switch, and hook red and black to the travelers, and white to common with a black tape band added. The down side is pulling the wire all the way through the box. BUT, I know the way we would do things in electronics does not always satisfy code, though it would save on wire nuts and wire. Thanks for your informative videos. I learned a bunch of this stuff from my dad a long time ago, but he went to trade school to be an electrician in the 1930s. Much has changed!
@Sparky-ww5re
@Sparky-ww5re 10 ай бұрын
Wonder if your dad learned the carter 3 way method, because it allowed power on both ends of a three way using 3 wires instead of 4 not counting the ground, and the economic hardships of the time forced many people to get creative and make do with the least amount of material. Actually ran across a carter 3 way a little while back on a farm with a yardlight between the house and barn with a single conductor running from the house and barn to the light pole, controlled by 3 way switches from different panels. House and barn were built c. 1910 and got electricity in the late 40s.
@jockenese5031
@jockenese5031 2 жыл бұрын
Liked the video. I get so many calls especially from one handy man friend that he’s removed a switch and can’t remember what he did. As you know it’s not easy trying to help him figure out what he’s done if there are multiple switches at the same location. Going to refer him here for the future. Anyway is a 3 way really a 3 way and is a 4 way really a 4 way??? A 3 way has a common terminal (let’s for simplicity say an input) and two other terminals which dependent on switch position are in connection with the common, throw the switch and those connections change. 1 way or the 2nd way, thus 2 ways. No matter how you bring power in it can only leave 1 of 2 ways. Same for a 4 way, power is always coming in on one terminal of two and leaving on one of two others on the opposing side, 3 1/2 way maybe?. Lol just messing. Using the amount of terminals as the WAYS doesn’t work, otherwise a 1way should be a 2way Being a euro trained spark living in the US for over 20yrs I’ve messed with a lot of my colleagues over the years. Typically we call a 3way a 2way and a 4way an intermediate (it intermediately intersects the travelers). I’d be interested to hear other thoughts on how switches got the names we use. Keep up the interesting lectures 👌👍
@jamesmarshall1993
@jamesmarshall1993 2 жыл бұрын
Hey Dustin. As a Canadian studying the electrical trade in our code books (CEC 2018 24th edition) Section 4-022-2 states that a Neutral conductor is required in every switch box. It reads as "The identified conductor shall be installed at each location of a manual or automatic control device for the control of permanently installed luminaires at a branch circuit outlet."
@rosskeenum4413
@rosskeenum4413 2 жыл бұрын
Thank you Dustin! I'm just a DIYer but had a situation where I had a misbehaving 3 way setup. Turned out to be a miswired dead end 3 way. I suspect it has never worked correctly for the 10 years since the house was built.
@billweare2146
@billweare2146 3 жыл бұрын
Thanks for your video. I ran across this Carter/Chicago style 3 way on a repair job that the customer had put in new switches and it was very helpful!
@Sparky-ww5re
@Sparky-ww5re 3 жыл бұрын
Lol did it take you some time to figure out what they had running? If so how long. Luckily I have personally never ran into a Chicago/carter 3 way, I have only heard of them and apparently they have been illegally installed decades after they became illegal in the mid 1920s. A fairly common application, was on older farms , and homes in rural areas, where you had a home, a yardlight and an outbuilding, and some receptacles in the outbuilding that are to remain constant hot, and 3 way switches in the home and outbuilding controlled the yardlight using only 3 wires instead of four with or without ground.
@ethanerwin8649
@ethanerwin8649 3 жыл бұрын
Thanks so much. I’ve never heard of the dead end 3-way. Literally saved me hours of work.
@foddermott9532
@foddermott9532 2 жыл бұрын
Perfect! The dead-end 3-way is just what I had been searching for. I want to convert a switch inside the attached garage into a 3-way with the second switch on the other side of the wall that has a pilot light so I can tell if the garage light is on or not without opening the door. Wiring the pilot into the dead-end shouldn't be a problem? Thanks for the video.
@binaryglitch64
@binaryglitch64 3 жыл бұрын
On those old Carter setups, did they run single conductor from the load or did they run Romex and just cap off a line in the box? Like what would I look for to know that it's wired Chicago style? I mean I can work out how to test it, but are there any tells that might lead me to testing for it sooner than later? Obviously age and location can help, but I mean by observing the system ... anyways you get the idea.
@ElectricianU
@ElectricianU 3 жыл бұрын
It would depend on who did the work, what they were taught, and what you have seen before in your career. Also geographical location. Some places just do weird stuff.
@binaryglitch64
@binaryglitch64 9 ай бұрын
So basically, if I'm diagnosing a switch, I have two indicators that can give me an idea that I might be looking at a carter... the switch device is a three-way but on a is set up on 2-wire, or the fixture has voltage refrenced to ground when off (if I'm luckey enough to have a ground wile being unlucky enough to run into a Chicago 3-way) but if I have no refrence at the fixture side other than hot and neutral, or if the sw-leg 3-way is burried and the line 3-way has had the device swapped for a standard switch by the home-owner who forgot to mention that as it happened years ago... (the actual situatuation I was facing back when I wrote that.)
@binaryglitch64
@binaryglitch64 2 ай бұрын
Meh, I got it, if looks sus I just test the light socket to see if the hot switches. We have a lot in a small town in central Kansas that has a bunch of old houses. I've run into one like 4 times in the last 6 months. Honestly I'm pretty sure one was a home owner diy job where he just kept trying things till something worked. The first on, the one that got me flustered and writing that reply. Service tech work has me getting pretty good at figuring this stuff out now. I swear though, if I run into another one I'm making a socket lead for my multimeter so I can just screw it in and let it hang while I flip switches and see if the polarity switches with it. Cuz I know the second I see a non-standard and assume, it's gonna be a cally or a dead end or a standard with the wrong colors and they won't be reassigned... these centry homes with residents almost as old are something else man. What a wild ride the career is. I've seen a doubled switched half and half (that's what I'm calling it anyways) it's like a switched half-hot recept but both outlets are switched from different switches. Don't ask cuz I don't know, it was a kitchen counter recept but it was made to be a switched half hot by taping over a switch. We made it a regular unswitched recept and just eliminated one switch and used the box for the other for a fan speed control. It was quite the project. But the grandma that lived there loved it. She baked us cookies (not all grandma cookies are the best, but it was the gesture so I choked two down and made it look like I loked them. Probably shouldn't have though cuz the dog wouldn't eat the other five that came home in a sandwich bag) anyways enough story time, thanks again Dustin.
@samuelcrossland1101
@samuelcrossland1101 2 жыл бұрын
This was very informative. I can't say I have seen the Chicago or California 3 way locally. But the one I didn't see is the hybrid 3 way. I use it mostly for entry halls. But to save that additional 2 wire switched leg, we run 3 wire from a switch box with power to say an entry chandelier box, then 3 wire back down making a dead end on the other side of the hall. Neutral comes from the power switch box. Switch leg is the common at the dead end. And yes you have to change the color of the travelers in the ceiling box to avoid having two white wires at the fixture.
@jleslie246
@jleslie246 2 жыл бұрын
I think this is what I have in my house.I have a foyer light with stairs. switch at bottom and switch at top. The bottom switch has a common/hot, neutral and two "travelers". the top switch has only one traveler and one neutral (coming from wire nut with 3 or 4 other white wires going who knows where). Im trying to wire up a smart switch but cannot get the top switch to work. Any ideas? and yes, I am not an electrician.
@samuelcrossland1101
@samuelcrossland1101 2 жыл бұрын
@@jleslie246 if there multiple neutrals in the box at the top of the stairs that tells me there at one point was a pig tail coming from the "hots" in that same box to feed the circuit. This is more akin to the California 3 way described in the video. In older homes a neutral is a neutral to older electricians. Neutral and switched leg comes from the bottom of the stairs and you have a black and white pair of "travelers" at the top of the stairs and a hot wire in the switch at the top is the common.
@samuelcrossland1101
@samuelcrossland1101 2 жыл бұрын
If you're wondering where how power gets to the switched leg, it's the travelers, all the switch does is alternate between the two travelers as paths. Commons are source and load.
@jleslie246
@jleslie246 2 жыл бұрын
@@samuelcrossland1101 the only wires connected at the top of the stairs are the traveler and neutral. it worked with the old switch but the new smart switch i put in at the bottom wont work with the top switch connected.
@samuelcrossland1101
@samuelcrossland1101 2 жыл бұрын
@@jleslie246 it needs a companion switch of the same type.
@DeanM-p5i
@DeanM-p5i 16 күн бұрын
Thanks. This is awesome. I know how to wire a 3-way, but every time I run into a new situation I'm like "I wonder if there's an easier way to do this." I also like that you point out which are to code (at least as of when you made this) and which aren't, and why. I'm not interested in doing anything not to current code, but when I find something wired differently in my (200-year old) house, I like to be able to decide whether I should update it or leave well enough alone. The "why" is really important there. Well done!!
@Audey
@Audey 3 жыл бұрын
Goddamn dead end 3-ways finally just clilcked for me. Describing it as just bringing the switch leg over to the 2nd box via the white wire in a 3-wire cable makes so much more sense than any other way it's been explained to me. Thank you!
@kaseyatwell1640
@kaseyatwell1640 3 жыл бұрын
Congrats, I finally understand it when I used my red and whites as Travelers instead of red and black. For some reason, Black wires always going to common side of switch always made more sense to me rather than using the white as a common.
@rockhouseoutdoors75
@rockhouseoutdoors75 2 жыл бұрын
Thank you man. I’m in vocation school right now and was really stumped on the dead end. My instructor kinda just told me to figure it out as he sees it as a better alternative of learning as hik showing us.
@gerardodh1951
@gerardodh1951 2 жыл бұрын
Hello and thank you for your videos , very solid. I have a question, how can I add a receptacle to a 3 way switch in my house if I don’t know where is the hot or the leg. Can I add a receptacle in any side of the 3 way? So far I added the receptacle, but works with only one switch…. If I flip one of the switches, it will turn on or off the receptacle. How can I identify the leg or the hot?
@timlouie5484
@timlouie5484 3 жыл бұрын
Your explanation and diagram of the dead end 3way perfectly described the hot mess I was seeing in switch boxes. Thank you so much!
@markied2873
@markied2873 2 жыл бұрын
Any way to make it work to an outlet?
@steveloux4709
@steveloux4709 3 жыл бұрын
Hey Dustin, one thing you mentioned parenthetically was the dubious use of #6 and smaller white conductor used instead as an ungrounded circuit conductor, and that doing so was not compliant, but that most AHJs would not cite this as a violation. Just a reminder that cable assemblies are discussed in Article 200.6 and even white wires #6 and smaller may be re-purposed as ungrounded circuit conductors by way of phase tape or other effective means. For cable assemblies, there is no code violation.
@darbyl3872
@darbyl3872 2 жыл бұрын
Good info. Thanks.
@garbo8962
@garbo8962 2 жыл бұрын
Wired up a huge house that had 5 seperate doors leading in the place. Had several hallways that criss crossed another hallway. Had at least 14 three way switches and maybe 6 four way switches. Sparky working with me never wired in a 4 way switch and screwed up wiring them. As long as you are using 2 NM cables for each 3 or 4 way very easy to wire them. Liked to put a piece of black tape on wire that feed switches.
@powwow8796
@powwow8796 2 жыл бұрын
I still do switch loops but I run them with 12/3 and cap off the neutral inside the switch Box
@fredericklangbein635
@fredericklangbein635 2 жыл бұрын
On the dead ends, I always did the white and red for the travelers and kept the black for the switch leg. I always stripped my common for the other people working on the finish. You need to show the fed at light with 2 dead ends, very useful in an old work situation.
@SuperVstech
@SuperVstech 3 жыл бұрын
I have worked on thousands of houses from the turn of the century and I’ve NEVER seen a Chicago 3Way… and I’m glad of it! Wow, who’d a thunk of that…
@wizard3z868
@wizard3z868 3 жыл бұрын
try living on the east coast especially New england where K&T is still widely present i ran into a cple of times. now word is out to call me when modern bulbs are burning up or just not working lol (im not a professional or licensed but i get a lot of calls from some asking to dble chk for a carter system lol
@heroknaderi
@heroknaderi 2 жыл бұрын
Very Cool and detaied information i appricciate it. the dead end method you showed at the end of the video looks like the one i used before I once did a 3 way setup to control some recessed lights in my bedroom to control from 2 spots.😎
@HennaMorgan
@HennaMorgan 3 жыл бұрын
I have come across another version of the dead end 3way where the power (via 14/2) was coming in to the ceiling jbox .running from their to each 3way switch was a 14/3. The neutral from the supply directly hooked to fixture ,the hot from supply to one white 14/3 , the other white 14/3 to the fixture hot, and both travelers capped together in ceiling j-box.
@jackallen3994
@jackallen3994 3 жыл бұрын
Most of the 3-way switches in my house are like this, which means you cannot install a smart-switch that requires a neutral. One solution I found was to install a smart-relay in the light fixture box. The problem with that is if you have to press the smart-relay reset button, you have to remove the light fixture to get to it. Does anybody have an acceptable way to use the existing wires, repurpose them in some way, so a smart-switch can be installed?
@jakesully5402
@jakesully5402 3 жыл бұрын
@@jackallen3994 It sounds like it’s time to replace the 3-wire with a 4-wire at the “hot” location. If you can’t attach a 4-wire to the 3-wire and pull through, well, I’ve learned from experience that they make drywall and mud everyday 🤪
@joshuaarellano6600
@joshuaarellano6600 3 жыл бұрын
Anyone know the name for this type of three-way?
@kaseyatwell1640
@kaseyatwell1640 3 жыл бұрын
I always called this Cali 3 way, except red and whites pass through light box as Travelers and 1 black is hot, the other black is switch leg. Same thing just different color travelers.
@ryanwashburn1804
@ryanwashburn1804 3 жыл бұрын
You should make a video about trouble shooting them on service calls.
@jamesdannibale3065
@jamesdannibale3065 3 жыл бұрын
I agree Ryan even if it’s not a true service call
@Aepek
@Aepek 3 жыл бұрын
One easy way if troubleshooting a 3-way on a service call and KNOW it is the issue…..undo all wires and rewire; find easier then trying to spend the time searching and looking and testing everything (and yeah, might end up doing anyway), but undoing all the wiring and doing over tends to be fastest and able to “see” what’s happening, imo. Everyone does service calls diff, so, this might work great for me etc…so, everyone has there techniques and steps for dealing with troubleshooting service calls😉 Cheers✌🏻
@that1electrician
@that1electrician 3 жыл бұрын
@@Aepek When you say undo all the wires and re-wire, do you mean re landing the correct wires where they're actually supposed to go? I'm a little confused about what you mean here.
@Rishnai
@Rishnai 3 жыл бұрын
@@that1electrician Easier to tell where things really go if not hidden / biased by the old known-wrong wiring
@glenmartin2437
@glenmartin2437 3 жыл бұрын
Thank you. I repaired a 3-way in my folks home years ago. I had to diagram it out to do the repair. This video really helped. Also, thanks for the code discussion. I started studying AC circuits and the code as a graduate student when an electrician told me 240 single phase was the same as 208 3-phase. Even as a professor, I get confused by the words in the NEC. So do the electricians and inspectors. Thanks again.
@ianshay2664
@ianshay2664 3 жыл бұрын
the same? in what context?
@mrromantimothy
@mrromantimothy 2 жыл бұрын
that's what makes our American system so good, 240 3 wire is a single phase Edison type circuit, and used in mostly residential, and 208 is two circuits of a three phase delta boat sharing a neutral, electricity can flow more freely through our grid without big differences in voltage, they are the same in regards to the equipment you are running, but they are very different in a lot of other ways. 208 in a three-phase wye system is a single pole stinger leg.
@douglasgreaves188
@douglasgreaves188 2 жыл бұрын
UK we call it 2 way switch, intermediate switch for adding extra. We don't mix lighting & sockets. Lived in US still mix up terminology & get some odd looks.
@yopappy891
@yopappy891 3 жыл бұрын
Very helpful video, I ran into a dead-end recently on a non working 3 way switch repair. Dustin your awesome Thank you.
@darinsmith9468
@darinsmith9468 3 жыл бұрын
I encountered this Cali 3-way crap on my 70s house in the Dallas area. They apparantly didn't want to spring for 12/3 cable, so they used 12/2 everywhere. Tied to a separate circuit's neutral & that's how I discovered it. Had the hallway circuit on for extra light, while working on a bedroom circuit--breaker switched off and confirmed. Unwired the neutral bundle in the bedroom switch box and got bit & hallway light turned off. Go switch off that circuit and open up the hallway boxes to find this mess. So my simple bedroom switch replacement turned into a run to the hardware store to buy some 12/3 and fix that crap. I checked the other 3-way setup for the garage & yep, same crap.
@brianpowers1116
@brianpowers1116 7 ай бұрын
I have this same setup in my early '80s house in the Houston area. They actually daisy chained the separate circuit's neutral so that the outside light hot used the kitchen neutral, the kitchen hot used the dining room neutral, and the dining room hot used the stairway neutral. Is this just a version of the California 3-way, or would this qualify as a different type of setup?
@raymondchow8722
@raymondchow8722 2 жыл бұрын
I recently did a kitchen/house remodel. I ended up scrapping all my 3 way switches. I had three 3-way (kitchen, hallway, & stairs) switches and replaced them with the Lutron smart switches. I know you are a electrician and it is less profitable for you to install wireless switches. But these Lutron Caseta switches/dimmers are legit. I even convert a existing 3 way situation into 4-ways by simply adding the wireless receivers. I have also convert the living room and family room single pole switches into 3 way Lutron dimmers. The great thing about the Lutron line is that the switches do not require neutral wire which mean you can easily upgrade your older houses into modern smart homes.
@wecsam
@wecsam 2 жыл бұрын
My newly constructed house (in 2022) had two dead-end three-ways in it, except that the hot side was at the dead end in both cases. To install smart switches, I had to flip the hot and leg sides so that the hot side was in the same box as the neutral wire.
@mikieboyblue
@mikieboyblue 2 жыл бұрын
I've done the same in my 1972 house. Basically "undid" the dead end three way and capped the red.
@bj2448
@bj2448 2 жыл бұрын
I really appreciate your explanations as you drew these diagrams. I encountered a situation where whoever wired this house ran the load and neutral wires from the light into Switch A, and connected the incoming hot line to the white wire along with the travelers, essentially bypassing Switch A to run the power directly to Switch B. This configuration was not represented in any of the standard wiring diagrams I was able to find, but your drawings in combination with some voltage and continuity tests (plus lots of head scratching) revealed the situation....and I was able to fix the 3 way circuit in my dining and add a functional dimmer. Thanks!!!!
@jimgarity1755
@jimgarity1755 23 күн бұрын
Thanks!
@bulldog_504
@bulldog_504 2 жыл бұрын
I just came across a California three way replacing a light switch in my house and I didn’t understand how three ways worked until I watched your video thanks for explaining how they work
@schowers
@schowers 3 жыл бұрын
Im used to seeing the "cali" three way in Houston (in new residential construction mind you) where they used/repurposed the white/"neutral" wire as a traveler.
@dalee580
@dalee580 Жыл бұрын
The animations were helpful. Finding out a variation of a dead end 3 way is okay for now was helpful. Mine had the travelers go like normal and the hot travel from the power source to the dead end through the white wire on the 12/3. The other switch common went to the light.
@ILove2Learn3
@ILove2Learn3 2 жыл бұрын
When it comes to the conduit fill and wire count there have been several times ive had to have 1/2" emt to a single switch but dont want to have another conduit come out of the switch leg side. What ive done is what i was taught is called a cold switched 3way....might be named wrong but this is where you have power and switche leg on the same side. All you do is tie your common wire into power right away which send the piwer side to the switch thats a die/ alone then wrap your switch leg on the travelers.
@williamsnyder6514
@williamsnyder6514 2 жыл бұрын
Hey bro love your content just an FYI 200.6(E) (exc) allows you to re-identify a white conductor as long as it's part of a cable assembly. You do correctly interpret 404.2(C) keep up the good work!
@happyfrybreadbushcraftands8637
@happyfrybreadbushcraftands8637 9 ай бұрын
Up here in Canada I've seen 3 ways done a different way. You use 4 wire cable, red, black, white and ground. You run such a wire from the wall switch up into the ceiling light fixture and then down to the other wall switch. You can bring a hot 3 wire into any of the 3 boxes to power the circuit with with slight variations. I'll use an example of running the hot wire into one of the switches. You connect the hot black wire to the common pole. You then connect the black and red from the 4 wire to the other two poles. In the light fixture box you connect the black and red so they run on to the other switch. At the end switch you connect to black and red to the same poles as the first fixture and the white wire running back to the box to the common pole. This makes the white running back to the light a hot wire, mark it with black tape at both ends. Now just connect the hot white to the base connection of the bulb and the white going back to the start to the neutral side. At the first switch connect the white from the 4 wire to the white 3 wire power in line. And of course all the ground wires in all boxes are connected together. There's a bit of variation you can figure out yourself when the hot 3 wire is brought into the light fixture box in the ceiling. This set up seems to make it simpler and easier to wire 3 ways. There's no mystery 3 wire running in the walls along a different path. Overall it reduces wire costs and stringing for most jobs. It's also a lot easier to fish a single wire in a repair or retrofit scenario in a finished home. I notice now there is no neutral in the last box which isn't current code. If I had to install a smart switch in an existing box without a white neutral I would connect the neutral pole to the bare copper ground wire. The electronics in the switch don't return juice down the neutral. They just need it as a reference ground voltage. The ground wire should serve. Not sure if this acceptable under code??? It should be safe if the smart switch is made properly. I've seen electricians do this back in the day for old 240 volt electric stove circuits that didn't have a bare ground wire. They would connect the newer stove's ground wire to the white neutral going back to the panel. As we all know the ground and white neutral eventually connect to the same piece of metal in the panel. All the neutrals and grounds are electrically continuous, connected, in a home. And you'd likely get a better ground voltage reference from the bare copper wire than a neutral which could get thrown off by juice inputs elsewhere along the neutral circuit. I think the makers of such switches made an unnecessary mistake in choosing the neutral instead of the bare ground for a reference ground voltage. Or perhaps to accommodate older wiring with no bare ground wire. Or maybe I misunderstand the need for a neutral in smart switches. I would think the bare ground would be preferable when available. Somebody should check into this, see if technically the bare ground is ok and safe to use and the makers say it fits with their design intent. This would make meeting code requirements easier and cheaper Just a note of caution here when using fixtures and switches made in or for Canada. Canada is bilingual, French and English. As a result laws require labeling in both languages. That creates a mistake that's easy to make. In French white is spelled "blanc". If you're not paying attention or in poor lighting it's very easy to mistake the "blanc" label on components for "black". You'll connect the hot wire to the wrong pole. Heads up on this eh! I've seen some weird things the text books don't describe in AC wiring and I've come to believe there is very little or no current or voltage from a device down the neutral wire. I've seen houses where someone stole the bare #6 ground wire from the panel to ground to sell the copper. The new tenant or owner is unaware and the electrical in the house seems to work, more or less. There's no connection to ground anywhere in the system. It's all running on capacitance instead of grounding. It's wonky and likely dangerous but most of it still works. Of course I immediately tell the owner they need to put back the bare #6 ASAP.
@Louieo2012
@Louieo2012 Жыл бұрын
If you use the Chicago 3 way to a florescent fixture would it make a difference???
@Sparky-ww5re
@Sparky-ww5re Жыл бұрын
Not as dangerous as on a regular incandescent with a screw shell, other than it's still against code to switch the neutral. If you hook up a Chicago 3 way to fluorescent, LED or HID fixture (not recommended) it can be switched from either end just like a traditional hot side/leg side 3 way because the fixture sees 120v when it receives a hot and a neutral, and sees 0V when it receives two neutrals or two hots
@steve-o6413
@steve-o6413 3 жыл бұрын
Great explanation for 3ways didn't know about the Chicago 3way even after many years in the Trade you can still learn new things...
@crimestoppers1877
@crimestoppers1877 3 жыл бұрын
Excellent presentation! Bravo!
@w1swh1
@w1swh1 2 жыл бұрын
Excellent Dustin! I like your emphasis on code. As often happens, ignore the code until the house burns down or worse a demise, and then remorse, "if only I had followed the code"
@lgninjalo
@lgninjalo 3 жыл бұрын
Conductors can be reidentified if smaller than #6 if part of a rated cable assembly. Thanks for explaining the cali three way.
@robertapreston4200
@robertapreston4200 3 жыл бұрын
your graphics are getting better every video. Love it❤👍👍 Rock your stuff... thank you for ALL you do👍👍😎
@xanataph
@xanataph Жыл бұрын
With DC SELV power there is a way of doing this that requires only two wires between the source & first switch , and second (remote) switch and load. The first switch is what you refer to as a "4 way", but is also called in "intermediate switch" - what they really are though is reversing switches. So it will simply reverse where the +ve and -ve poles appear on the travellers. Then at the remote end one terminal of the lamp is connected to one of the travellers and the other is connected to the common of a three way switch (SPDT in panel switch nomenclature) the other terminals are both connected to the other traveller, but through diodes, that are reverse polarity to each other. When the polarity of the current in the travellers matches the diode leg that is switched to the lamp it will light. If the other diode is selected it will block the current and the lamp will remain off. This of course means you need to use a lamp that is not polarity sensitive, such as an incandescent bulb, but generally MR-16 base LED lamps already have rectification built into them. Alternately, you could use a second intermediate switch at the remote end, then just one diode would be required (but on the lamp side of the switch) and the current would always flow in the same direction through the load. This setup also allows a permanent source of power at the remote end from across the travellers. Of course they will reverse polarity as the intermediate switch is operated at the source end, but if this is an issue for the load a bridge rectifier can be added. The switch at the source naturally needs to be rated for the current of both the lamp and the extra load.
@nicholsconstruction1
@nicholsconstruction1 3 жыл бұрын
Thanks for sharing your knowledge. Just working on my house today, moving switches and ran into a Chicago 3way. It was kicking my butt. But after watching this video it went back together as you described. 3 way back up and working.
@steinravnik8692
@steinravnik8692 2 жыл бұрын
I had a 1926 rowhouse in Washington DC that had a 3 way wired with the Carter method. It wasn't working right when I bought the house. It took quite some time for an electrician to get it working right. The house wiring was Greenfield, and I did not want to rewire the area where the switch was. Due to the wiring being old, it was hard to distinguish between the colored fabric coating.
@comingtofull-ageinchrist6736
@comingtofull-ageinchrist6736 2 жыл бұрын
I stopped going to electrician groups, and, really, I only entered into these type of chat groups for a short time. I would look at some of the discussions on different topics and really didn't find any helpful information being given. I did find myself digging into the NEC code book a lot, though. I remember going online to look for questions for exam prep and spent more time searching the NEC trying to decided if the the question was even legit lol, but it did get me into the code and made me search for the truth, and I find that a lot of it is interpretation, and you have to weed through all that as well. I think the important thing is trying understand what the panel for each section might of been trying to convey. Because one thing that a person brought to me attention that sat on panel 5 and 17 of the NEC is that The National Electric Code is a "minimum safety requirement", so when I'm looking at the code, I'm thinking minimum safety requirement as a fundamental rule in interpretation!
@Bloated_Tony_Danza
@Bloated_Tony_Danza 2 жыл бұрын
Two year helper here, boss's son has "ten-thirteen years experience". It's amazing how well he cites code to explain something and be absolutely wrong. Not just wrong, but like holy hell I'd be so screwed if I listened to you wrong. Destroyed equipment wrong, it's actually astounding. He's convinced himself of absolute absurdities and he's trying to teach them to me, only to be stopped dead in his tracks and told to shut up
@TheHellKnight
@TheHellKnight 9 ай бұрын
seriously considering a career as an electrician now. thank you very much, brother.
@MichaelRGlatfelterJr
@MichaelRGlatfelterJr 2 жыл бұрын
Both of my three ways I have in my home are the dead end type. Both are for controlling lights from two different floors. So, I have a normal 3-way downstairs for an outdoor lamp and upstairs a smart 3-way for the same lamp. The other is similar, smart 3-way upstairs for outdoor stairwell and normal 3-way downstairs. I only have and need neutrals where the smart switches are and the normal 3-ways don't go to any outlets, so neutral is not necessary.
@AM-hf9kk
@AM-hf9kk 3 жыл бұрын
Sending this to my Father-in-Law. The previous owner of his place had some hack install a "three way" circuit in the living room, one switch at the front door and one at the kitchen. Unfortunately, it's only 14/2 throughout and uses single-throw switches. Dude got it right in that both switches WILL turn the light off... but if you turn it off at the front door, the kitchen switch won't work. If you turn it off at the kitchen, then the front door doesn't work. The hack just put two switches in series, then installed a ceiling fan with a pull switch, which is what my in-laws end up using. It pains me greatly and I end up walking around in the dark rather than dick with it. I'm dreading replacing that mess because my Father-in-Law thinks the attic is unsafe and hasn't agreed to let me look at it yet.
@tidwellelectric
@tidwellelectric 2 жыл бұрын
So many right ways to wire 3-way and 4-way switches! Check this out, I always use the WHITE and RED for my travelers for efficiency. Yes I have to phase but you would anyway if your pulling switch legs and/or power out of 4-way locations. Also when your running a dead end 3-way (just one 14/3 in a box) you must have to use the white for the common and phase it. Mainly its nice to have options on a long 4-way run to put light leg and power where you want to along the run without being confused by the splice. Just make sure your crew is all doing them the same way!
@neilspell8727
@neilspell8727 3 жыл бұрын
I know of another type of "3-way" switch. A smart switch (Alexa- or Google Home- capable, for example -- also, some dimming 3-ways) uses the three wires as 1) Hot 2) Ground and lastly 3)"data/communication". I was baffled until I finally got it right. Then I realized what was happening. Both switches need to be "on" to respond, so a hot and ground are needed. But the switches also need to know what the other one is doing, therefore one of the wires is used for communication.
@LibertyDIY
@LibertyDIY 4 ай бұрын
Also, many of those AC powered smart devices draw 1 or more Watts of standby power, 24-7. May not seem like a big deal but when every GFCI, AFCI, wifi switch, remote switch, motion sensor, dusk dawn sensor, microwave, toaster oven, washing machine, dryer etc etc are smart, you get a sizable phantom load even when all the devices are off.
@benjaminc.m.9873
@benjaminc.m.9873 2 жыл бұрын
So glad you have a digital white board now, much better
@ian_snyder
@ian_snyder 3 жыл бұрын
Amazing video! I’ve been helping a friend with some electrical work and I’m pretty sure they’ve got a dead end 3-way but didn’t know enough about it, so this was perfect info for me 👍 Subbed! 💪
@ElectricianU
@ElectricianU 3 жыл бұрын
Thanks for the sub!
@maxderman447
@maxderman447 3 жыл бұрын
Yo dustin I'd love to see a Code Myths video! Most recently I've debated 1. Connecting all grounds in a junction box (even when there's 2 different sized circuits) and 2. Running romex through EMT
@ericfine5200
@ericfine5200 3 жыл бұрын
Fairly certain both is wrong....I never tie my grounds together from different circuits out in the field. Even if it's not code I could see it being code eventually. Obviously I'm referring to houses and not your commercial environment with conduit and such. I just like the idea of having everything separate. Easier to diag on the future
@anthonysmith9410
@anthonysmith9410 3 жыл бұрын
No romex thru emt…….thats a no no
@mrbmp09
@mrbmp09 3 жыл бұрын
I think he already did the romex in duit video, Its a no if it can get wet. I think.....
@juledoren
@juledoren 3 жыл бұрын
@@anthonysmith9410 that would be a bitch to pull😂😂 we have pulled romex thru 2” emt that was stubbed out of panels before but screw pulling romex in emt for over 2’
@spelunkerd
@spelunkerd 3 жыл бұрын
Oh, this (sharing grounds) is one we should talk about. You can't share neutrals but I don't see why one can't share a ground. So, pulling two circuits from the same panel through conduit, do you guys pull two separate insulated ground wires even though they go to the same place at either end? They all attach to the junction box anyway, and one circuit blows at a time. It seems a waste....
@pabloluna7881
@pabloluna7881 3 жыл бұрын
Well here in Oklahoma City we always called the California three-way it's where you have the hot and switch leg in the same box and you just send the switch leg over on the white wire
@KevinCoop1
@KevinCoop1 2 жыл бұрын
Many years ago, before neutrals required in boxes, a couple country boys were wiring rows of fluorescent lights with 3-ways. They took power to the first light and from that point used only 2 conductor NM cable. It took me a while to figure out how they did it. Legal? As far as I can tell, it met all NEC requirements and could also put a neutral at both boxes.
@andevipertraderpfeiffer8787
@andevipertraderpfeiffer8787 2 жыл бұрын
Holy s*** dude tons of thanks this is the only video to diagnose a California 3-way in a 50 year old house
@comingtofull-ageinchrist6736
@comingtofull-ageinchrist6736 2 жыл бұрын
the last California 3 way you described is the only one I had ever heard of, and, like I said, someone from Cali came along, once upon a time, and said, that isn't a California 3 way lol. I don't know how anyone can argue with that lol. personally, if I'm wiring a new home or doing a remodel, I'm going to put a neutral in every switch box and I'm not going to cheat on cost by using a 12/3 to send a switch leg to the other side. I'm going to put the hot on one end and the switch leg on the other. Not that big of a deal and I don't need someone to tell me to put a cover on a box or conduit body lol; it's just something I'm going to do to protect the wires in the box and make sure someone doesn't accidentally come into contact with it. People can interpret away. I'm just going to do best practice! I, personally don't see no good reason not to put a neutral in every switch outlet, so that's what I will always do. People don't want to, that's on them. I don't need a code book to tell me to put a neutral there. In Oklahoma, people are using programmable switches that require a neutral hooked up to the switch, so it's just a best practice for everyone. Again, The NEC is a minimum safety standard, so it's ok to go above and beyond requirements!
@KameraShy
@KameraShy 3 жыл бұрын
Always very interesting and informative. I am in Chicago and never heard of a Chicago 3-way. At least in the electrical context.
@glennreynolds962
@glennreynolds962 Жыл бұрын
I use red & wht as travelers in a 3way so the blk is the leg. I have also had a feed at switch A with a 3wire going to the light and a 3wire from the liight to switch B. The wht in switch A is neut and blk & red travelers. Switch B red & wht are travelers and blk is switch leg. I served my apprenticeship in the early 80's in NJ
@brianfolsen1919
@brianfolsen1919 2 жыл бұрын
Hey Dustin, you briefly mentioned an old home built in the 40's still on 2 wire. Where can I find out troubleshooting and different issues that may be possible in this situation? I rent a duplex that is that very situation. I have a breaker that was tripping. The landlady sent out an electrician who couldn't figure it out. I started messing with it and find all kinds of strange conditions as I check places with my meter and tools. I just want to be sure stuff is safe. Thanks. I have learned quite a bit watching your videos.
@CrazyDude1705
@CrazyDude1705 3 жыл бұрын
If you want more than 3 switches for 1 light (let's say in the staircase of an apartment building), just use a relay in the breaker panel with a push button circuit as switches. Standard practice in Germany. :D
@ricksmith1156
@ricksmith1156 2 жыл бұрын
Hey Dustin, I have a end three way switch that I want to jump off of to a single pole switch to operate an outside light. Can I do this ? The travelers are hooked up and the neutral is recoded black and I want to jump to the single pole.
@jasonji1900
@jasonji1900 2 жыл бұрын
On the Cali 3 way, hot needs to come into the left switch at one of the other two terminals. Bringing it into the middle point of he switch gives the left switch total control over the current supply to the bulb.
@barrysharp3559
@barrysharp3559 3 жыл бұрын
Here in the UK we have 2 way switching what you call three way and intermediate which is what you call a four way, which similarly can have as many switches as you want in theory.
@kevinchang4962
@kevinchang4962 Жыл бұрын
Awesome video , was looking for a explanation for a dead end 3 way wiring without using recepticals in your explanation. Just a dead end 3 way using the 2 switches and the light
@caring-assoul_
@caring-assoul_ 8 ай бұрын
Man, I remember the days when it first started as an apprentice doing residential electrical work and I would always come across these and the California version as well. A lot of exciting 💥moments for me back then😅.
@sr.gateau
@sr.gateau Жыл бұрын
Had a 4-way in a previous home. Needed to figure it out in a pre-KZbin era. If you want to use smart dimmers in a 3-way setup, neutral will be required in both dimmer locations.
@AdamSmith-ze6gl
@AdamSmith-ze6gl 3 жыл бұрын
Amazing descriptions, thanks. First video that helped me explain the dead end method for a remodel I'm doing. What is the best practice to re-identify a white (on dead end) to hot?
@ElectricianU
@ElectricianU 3 жыл бұрын
Good to hear! To answer your question: Tape. Field identification for switch loops and re identification for HVAC systems is allowed. Just can't identify an ungrounded conductor as grounded.
@blueyesterday3920
@blueyesterday3920 3 жыл бұрын
Excellent content!!! The only two three ways I’ve ever known were the regular and dead end. I always heard the dead end called the “old way”.
@toadjones79
@toadjones79 2 жыл бұрын
Ok, big question. I have several 3 & 4 way switches that were wired with the power at the light fixture. So no neutral at any location. Very frustrating. What I am wondering is if there are any tips to dealing with this for adding smart switches? Alternatively, if I have to I can run a new wire from the panel up through the wall into the boxes from the basement. But then I am unsure about violations having the circuit spread out across the building that way. Having hot come in from above on an old wire, and grounded conductors come in from below in a new wire.
@frankgorgone6679
@frankgorgone6679 3 жыл бұрын
What about the 3 wire going from switch to light and them N from light to switch? I wired homes like that for years. It saves you time and wire. The powered side is used for the neutral and the dead man side is legged. Any thoughts on that one. I’ve also come across a legged 4 way a few times
@robertstovall7195
@robertstovall7195 9 ай бұрын
Thank you for the Dead end 3 way lesson! Nobody else showed it.
How Many Lightbulbs on a Circuit? USE OHM'S LAW!!!
2:59
Electrician U
Рет қаралды 42 М.
THIS IS WHY ELECTRICIANS DON'T HIDE J-BOXES IN WALLS - Finding Hackwork!!
30:07
小丑教训坏蛋 #小丑 #天使 #shorts
00:49
好人小丑
Рет қаралды 54 МЛН
How To Wire a 3-Way Switch System
16:28
Sparky Channel
Рет қаралды 3,9 МЛН
How Japan Made Their Outlet Safe
12:32
Andrew Lam
Рет қаралды 573 М.
Five Things Apprentices Should NEVER Do!!!
18:56
Electrician U
Рет қаралды 242 М.
What Wire Connector is the Best? Settling a Debate! Wire Nut VS Wago
11:09
How To Wire A 3-Way Light Switch - 3 Way Switch Explained (2 EASY & SIMPLE Methods)
20:37
Sub Panels Explained - Why are neutral and ground separated?
16:22
The Engineering Mindset
Рет қаралды 1,6 МЛН
How to Wire an Electrical Panel - Good Workmanship
27:38
Electrician U
Рет қаралды 294 М.
How 3 Phase Power works: why 3 phases?
14:41
The Engineering Mindset
Рет қаралды 2,1 МЛН