This is a hydraulic elevator. What it's doing is called "blowing through the floor" in the down direction. Unit valve in the machine room most likely was out of adjustment. It's hitting the buffer springs in the pit and releveling up to the floor. This opens the bottom emergency terminal switch which cancels the call that was registered. Doors then won't open unless DO is pushed on the COP or another call is registered. When it blows through intermediate floors in the down at full speed, it levels down to the next floor. Single floor runs it's not getting up to rated speed and re levels at the floor. Typical of Down Transition not being adjusted properly. That adjustment increases and decreases the Down Leveling transition from full speed. I've installed, replaced and adjusted Maxton and EECO unit valves many times in the last 14 years as an Elevator Constructor.
@beedslolkuntus20705 жыл бұрын
Wow thanks for explaining mate
@jonathankoster5472 жыл бұрын
I've been looking for this for YEARS and I finally found it!
@CenTexElevators4897 жыл бұрын
See what I mean about these newer generic elevators? They break down so much, because they always are the lowest bidder, and the old ESCO lasted 55 years with absolutely NO problems!
@lucasnassar27785 жыл бұрын
CaptainElevator42189 And why Star City Elevators rides this thing,why didn't waited one month to go,it's not full calibrated yet,if I was him I had to wait after 1 month at least modernized then I could go
@TheOfficialDorianelevator Жыл бұрын
man that hydraulic valve is completly busted... oh and also 4:47 killed me of laughter
@mattmoreira2105 жыл бұрын
Oh! I don't think it's supposed to do that... let's continue riding it until it breaks!
@aprilkolwey47797 жыл бұрын
As kind of a wild guess, maybe the ULM (upper leveling marker) sensor on the tapehead isn't working properly, so it doesn't realize it should be slowing down for the floor until it actually gets there. By that point, it's too far to stop in time, so it misses the floor, and then the controller decides to go downwards to one of the limit switches (bottom floor demand) to kind of "recalibrate" in response to seeing unexpected inputs from the broken tapehead.
@ThompYT6 жыл бұрын
probably also doesn't help that it's most likely a 2 speed motor
@apetersenALT6 жыл бұрын
This is why generic stuff SHOULD NOT EXIST!
@lucasnassar27786 жыл бұрын
Adam Petersen Maybe this one was sed up to manual controlling
@2035jim2 жыл бұрын
It’s not a controller issue it needs a new hydraulic valve
@chrisblackstone59757 жыл бұрын
the second part of the video you mentioned some vibrations. The mic picked that up perfectly. I am wondering if for some reason the brake wasn't catching properly if that would cause the vibrations I heard at the end of the video.
@sheagenix53205 жыл бұрын
You're super brave to play with elevators the way you do. I couldn't do it, so it wouldn't be the job for me. I barely like riding them but then again I don't like exercise so there you go lol
@snddly846 жыл бұрын
Seems to me that if it weren't for elevators this guy would be in his mother's basement staring down a dark hole muttering something about lotion and hoses...
@jaworskij5 жыл бұрын
No matter how many times I replay this video I just can't understand what he's mumbling about at 0:22
@helpthehurtlondon5 жыл бұрын
just an afterthought, that fire alarm pull station is wayyyyy too close to the elevator call buttons
@aandersen937 жыл бұрын
I also feel like placing the fire alarm and call station next to each other may not be a good idea on the 1st floor.
@JordanLoweElevaToursCanada7 жыл бұрын
aandersen93 I agree.
@casualgamer246 жыл бұрын
YA SOMEONE can easilly pull it
@silasmcgee36476 жыл бұрын
Evan The gamer 3:04that's probably the cutest sound the elevator made
@thecarwashelevatorfanatic74335 жыл бұрын
Silas McGee Weird.
@arizonaelevatorsandmore27782 жыл бұрын
This elevator is definitely not a Minnesota Elevator, this is a generic junk elevator.
@EvergreenElevators5 ай бұрын
Did you not see the branding on the door jamb at the beginning of the video when he shows the door equipment? Because I'd argue it says otherwise...
@HSETM5 жыл бұрын
When it's going up, the stuff under the lift might be pulling on the buffer spring. When it's going down, the buffer might be hitting something, making it safety break
@SAMIEWALLFORD7566 жыл бұрын
Whoa!!!... Is suddenly a death trap of THIS elevator! Elevator needs fixtures and re-installed on the system modernized properly. How creepy done like this?!
@aandersen937 жыл бұрын
The elevator in Temple Building will often under level when it hits the basement and relevel while the door is open. Sometimes on other floors as well if it's been heavily used that day.
@inkognito88886 жыл бұрын
My university institute has an 60 years old elevator where you manually open the outside door. On each stop it jumps with such a strong jump you are unable to carry a full cup of tea within it. :-D
@watchmakerful6 жыл бұрын
This is typical for single speed traction elevators.
@luznoceda58626 жыл бұрын
Idk why but while u were doing this I was like: Stop it stop right now..
@EDISONTECH6 жыл бұрын
7:55 Classic Leveling!
@HannahBug16 жыл бұрын
That elevator makes scary noises. ;-;
@HannahBug16 жыл бұрын
They should replace that elevator then.
@silasmcgee36476 жыл бұрын
HannahBug1 or as a description says should have kept the older elevator
@Jamestube84397 жыл бұрын
Is it a Schindler? Also I think the elevator was going down and while it was doing it, it crashed to the ground and then it thinks it messed up and moves up to level with the floor, that's I think, it may not be calibrated with the floors correctly
@Jamestube84397 жыл бұрын
Also notice, you can here the motor after the crash, it had to be leveling with the floor when it crashed.
@mattXJF6 жыл бұрын
It’s a Minnesota
@blockavgaming74402 жыл бұрын
I also have a deep fear of elevators, so thats why i always use the stairs.
@JuanP19302 жыл бұрын
Everything is gud if you use an hydraulic elevator because in that one you can't free fall in the elevator
@VeeTHis Жыл бұрын
@@JuanP1930 Traction elevators can't free fall either
@JuanP1930 Жыл бұрын
@@VeeTHis why are you in a comment from 3 months ago?
@Patriot2609 Жыл бұрын
The elevator is statistically much safer than taking the stairs...
@jetway7566 ай бұрын
@@JuanP1930Fun fact, sounds stupid, but hydraulic elevators CAN free fall, and in a more uncontrollable way than tractions, but as long as they're maintained well that won't happen
@inactivechannel70295 жыл бұрын
Hey, you aren't the only one who has gotten stuck in a generic! I have too!
@najlaallawati72326 жыл бұрын
When i went to Iran there was a hotel called toos I rode the elevator it was a little bit different elevator when you reach the floor it under levels and mid levels
@HSETM5 жыл бұрын
2nd guess: It might have hit one of the final limit switches
@LuarAuditore6 жыл бұрын
At 4:04 if you look carefully at the elevator it looks like it going up without the door closing
@aghcatz6 жыл бұрын
Can you please go to Lithuania for a lift test? There are some old elevators, you can check them out ;)
@BitGridTV6 жыл бұрын
it might be a reasonable programming if the elevator does not open automatically when reaching the basement. think about water possibly being there or gas/smoke.
@lucasnassar27785 жыл бұрын
BitGridTV Yes,just one week and it's not on full installations
@AlanTech12 жыл бұрын
you ended the video when you where inside the elevator most people end it when there outside just saying Lol
@supertechnocat82536 жыл бұрын
Any background history of Wright and Mack elevator?
@MrEngineer200516 жыл бұрын
At the end of this video when there was new padding in the Elevator, your talking was softer. And at the beginning of this video, when there was no new padding in the Elevator, your talking was louder.
@crazydogeROBLOXBuildingandGame5 жыл бұрын
Feel like the door drive may have something to do with it not opening its doors by itself on floor 1 and level B
@drdog101schannel46 жыл бұрын
And I Also Think That It Doesn't Open Due To The Fact That Once Its Done Releveling It Thinks It Already Opened And Closed, And The Time For The Door To Stay Open is Really Short So Thats Why The Controller Must Think That.
@JordanLoweElevaToursCanada7 жыл бұрын
This may be new but it could use some help. This controller on the elevator is really messed up!
@RaynFox7 жыл бұрын
It was like the thing doesnt have brakes when it stopped at basment, but the real reason is, the floor is too close to the cab, so it stops, but the door wont open. And when you wanted to stop at 1, it forget to brake and slowly did go Down to the basement, Controller may be failing ;)
@livionaves7 жыл бұрын
It went a little bit more down than necessary and had to pump some oil to level up correctly to the basement. The problem is that it did that abruptly. There is a video of some filmer where a Schindler Hydro in a dept. store did a similar thing while leveling down at the ground. Strange that this one didn't open the door automatically.
@blueauraretriever7 жыл бұрын
Maverick 3458 I've been on TWO Schindler MT hydros this year that did the same thing. I think that's just a unique characteristic of the logic.
@StarCityElevators7 жыл бұрын
Must be a fairly new thing. Either way, it's just enough of an issue to set the average person on edge like they're trapped. It might be that some sort of leveling switch/valve was not engaging at the proper time.
@lucasnassar27785 жыл бұрын
Lívio,acontece que nesse vídeo a modernização não passou de uma semana,ou seja a máquina ainda deve estar aprendendo a funcionar,nem todos aprenderão a nivelar rapidamente,o Star City Elevators não poderia estar indo nele,é por isso que tem que esperar pelo menos um mês para calibrar tudo corretamente
@jahairareyes56382 жыл бұрын
your not alone 😂 that happens to my elevator sometimes
@Dewbertee5 жыл бұрын
Why I see a hand print on the left lol
@StrawPlayz17 жыл бұрын
New elevators sometimes had some glitches here and there but this elevator wasnt calibrated right
@lucasnassar27786 жыл бұрын
Straw Playz If is recent,they had to set in service,to make everyone know they're still in tests
@AquaSea176 жыл бұрын
Nice video
@drdog101schannel46 жыл бұрын
@Star City Elevators Thats Call Releveling, It's when the elevator went down too much from the basement and it had to use to hydraulic motor to go up again so that you can get out safely, So Really The Elevator Wasn't Malfunctioning.
@lucasnassar27785 жыл бұрын
DRDOG101's Channel Yes it's still learning,an elevator in 1 week modded it's still learning the new things,cost any wait?
@Psevdonim1235 жыл бұрын
The leveling is so painfully long! Even for hydraulic... The pump might be failing, as it overshot's the floor only on way down.
@StarCityElevators5 жыл бұрын
It's a brand new elevator (not a mod)...and if you watch till the end of the video, you will see that they fixed it. I should probably do an update on that though...
@Psevdonim1235 жыл бұрын
@@StarCityElevators Even if it's brand new there might have a leak or solenoid valve might have been too weak... New lifts (elevators) also can break especially in first two months or so. Because every installation is a bit unique and engineers need a time to set everything up correctly. I don't think that in this situation it was a wrong setting though... It might have been a manufacturing defect
@StarCityElevators5 жыл бұрын
@@Psevdonim123 It's possible that might be what happened. Usually I give an elevator six months to a year to get up to "out of the box" working order. I don't remember how old this was though, probably less than a month.
@scythal7 жыл бұрын
If this happens really frequently, the buffer springs would wear out.
@rainalmida44366 жыл бұрын
I think the elevator can't stop at basement or 1st floor because there is no one lives there
@Jamestube84396 жыл бұрын
Instant door close.
@AN-yy9cq6 жыл бұрын
That looks to be a major controller issue.
@chrisblackstone59757 жыл бұрын
received a reply to my comment I had posted about this particular lift. What the individual doesn't realize when they wrote their reply is I have been watching videos like this for quite a while. So, it is easy to pick out a installation that is a garbage insall or badly maintained. This installation in this case is both a crap install and not kept up very well.
@lucasnassar27785 жыл бұрын
Chris Blackstone Well but don't you know that a modded elevator when even did just one week it still can be in tests,why a person like has to ride without waiting the full installation,at this time the machine is still getting it's learnings
@msj1919617 жыл бұрын
Garbage installation. Nothing more to say about it.
@supertechnocat82536 жыл бұрын
Rushed Modernization? :/
@lucasnassar27785 жыл бұрын
Super Techno Cat Actually he is wrong of riding something fresh out of the box,it's just one week in this video,why not wait once everything is done,the installations are complete?
@OPG27116 жыл бұрын
LOVELY.
@Creamcrus Жыл бұрын
why the elevator 1st the 1F to BF HUH
@boiii3productions945 Жыл бұрын
If it’s new it should’ve been mrl not hydro
@OrlandoGamingOfficial11 ай бұрын
That isn't normal...
@HSETM5 жыл бұрын
It safety breaks at -1
@AquaSea176 жыл бұрын
The elevator was making creepy noises
@chaterii80936 жыл бұрын
I would of broke the alarm button for help
@albertsflamingo79935 жыл бұрын
I'M SO CONFUSE
@BNSF44752 жыл бұрын
Nice job MEI 🙄
@EC_32768 ай бұрын
MEI with fully innovated bruiser
@drdog101schannel46 жыл бұрын
and I also think it never opens cause the timer for the door to stay open is like.. really short so once its done releveling it thinks it already opened automaticly
@DaRealIlnois7 жыл бұрын
All those buttons
@chrisblackstone59757 жыл бұрын
elevator is simply crap. I was listening to it going down and it is strange how it sounds like it stops for half a second and then from what it sounds like the pump kicks on and it continues to go down. I however also didn't like the sounds it made when it would go up or down at certain points.
@mataribrahim85007 жыл бұрын
Chris Blackstone its crap huh? Ur lazy ass uses it everyday boi shut up
@Jamestube84397 жыл бұрын
Not calibrated.
@bernardtheaubreycoxandcoolgame4 ай бұрын
That's creepy
@VOLTRONDEFENDER44406 жыл бұрын
I hate when that happens
@dawnzephyr6 жыл бұрын
Obvious question, did you let anyone know there was a problem?
@gracephipps94235 жыл бұрын
im scared of elevators so when he was standing in the door way I was like GET IN THE ELEVATOR BEFORE THE DOORS CRUSH YOU
@TransitUSA7 жыл бұрын
Hate to say it, but thats a POS.
@juggernaut9116 жыл бұрын
U have no life straight up
@bss13466 жыл бұрын
Arash Mazand fuck off mate 😂 look at your views compared to his views...
@dickcheney66 жыл бұрын
Not an elevator technician, but could it be the device that tracks the elevator's position?