Emergency Generator OFF-LOAD and ON-LOAD TEST. | SOLAS Regulation for Emergency Power Supply.

  Рет қаралды 8,119

Lecky Louie

Lecky Louie

Күн бұрын

Пікірлер: 19
@hunskhant-xq7pv
@hunskhant-xq7pv 8 ай бұрын
Wow very good post migo.. good working habits. ❤❤❤❤
@WandiSuardi
@WandiSuardi 11 ай бұрын
thank you for your great video sir, thats really help..
@francisglenndimacuha4030
@francisglenndimacuha4030 11 ай бұрын
Thank you Lecky
@natnaeltesfaye8280
@natnaeltesfaye8280 6 ай бұрын
Thank you and pls make another video how to setting the 45 sec time relay and point as the located
@malakadananjaya2046
@malakadananjaya2046 Жыл бұрын
Great video
@leckylouie
@leckylouie Жыл бұрын
Thank you for watching sir..
@denwa-pres
@denwa-pres 9 ай бұрын
Ayos ka lecky
@thanhtutaungetr
@thanhtutaungetr 4 ай бұрын
Thanks for your vidoe
@leckylouie
@leckylouie 4 ай бұрын
thank you.keep watching
@pogssss5058
@pogssss5058 2 ай бұрын
Thank You Sir,
@vladimirshandrenko5139
@vladimirshandrenko5139 2 ай бұрын
Thanks a lot
@anasamery2186
@anasamery2186 5 ай бұрын
Thank you. I have a question after I disconnected the supply from the main power in the case of the test.... After the generator starts and supplies the emergency switch board, what will be the fate of the electricity generated during the emergency, because in the case of the examination, the main generator is the one that supplies the power,
@leckylouie
@leckylouie 5 ай бұрын
Sir, during the test of Emergency Generator, the TIE BREAKER between MSB and ESB will automatically open. then the MSB has still normal power. But the ESB is totally blackout during the test and the back up Emergency generator will start and gives supply to ESB.
@randynotarte9943
@randynotarte9943 Ай бұрын
Sir paano Yung dalswang g/e nka parallel tapos pag tsnggalen Ang load Ng Isang g/e nag prefential trip
@sultanhussain6051
@sultanhussain6051 Ай бұрын
For on load test should we required to turn off radar equipment etc ...kindly reply
@leckylouie
@leckylouie Ай бұрын
Yes, to avoid damaging the radar and other bridge equipment. always inform the bridge duty officer to shutdown radar and ecdis prior blackout simulation test.
@sultanhussain6051
@sultanhussain6051 Ай бұрын
@@leckylouie yup ...many Thanks
@spanasia317
@spanasia317 9 ай бұрын
SIR SAAN MAKITA ANG TIMER RELAY PARA MEET NIYA YONG BELOW 45 SECOND.
@leckylouie
@leckylouie 9 ай бұрын
sir,.sa.loob ng.emergency.switchboard, andoon ang mga.timer relay. naka.set ng.SECONDS.
SHIP EMERGENCY GENERATOR - LOAD TEST
8:33
joel sibulo - Life of a Seafarer
Рет қаралды 2,7 М.
Zombie Boy Saved My Life 💚
00:29
Alan Chikin Chow
Рет қаралды 34 МЛН
BLACK OUT AND EMERGENCY GENERATOR, THINGS YOU NEED TO DO
11:20
Learn SOLAS regulations for Emergency Generator in a FUN way!
7:14
How To Carry Out The On Load Test of Emergency Generator
5:41
Marine Engineering 1O1
Рет қаралды 175
Steering Gear Safety Devices and Alarm Testing | Pinoy ETO |
15:15
Generator load bank testing at my high school
15:55
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 7 М.
Emergency Generator In Ship | Starting procedure | Black out
12:27
ETO VIVEK KUMAR
Рет қаралды 6 М.
Generator Reverse Power Protection Test | Pinoy ETO
7:36
Lecky Louie
Рет қаралды 10 М.