things like air vent, isolation valve, pressure relief valve and selection of gauge well explined.
@WeldingandNDT4 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@yasirkhan47434 жыл бұрын
No one can match your quality explanation. ..thank you.
@WeldingandNDT4 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@AAMIRSHAHZAD11223 жыл бұрын
@@WeldingandNDT sir channel ko join karny me problem aa rahi ha CSWIP 3.1 ki video kaisy dekhan
@tapasdash11002 жыл бұрын
Very well explained sir. Being a non technical person too I could easily understand the entire thing. Many wishes for your channel.
@WeldingandNDT2 жыл бұрын
Thank you. Please join my channel to support me. Joining Link: kzbin.info/door/H7nXSievFlbRKzKzEySbkwjoin
@arunkumar-ij8lw2 жыл бұрын
@@WeldingandNDT sir 10 minutes and 6minute/cm maximum 2hr... Can u pls explain
@ودجادينجادين-ك6ح2 жыл бұрын
Thank you very much ,,if we make a pressure test for pipes with liquid out of water, what is allowable drop in pressure?
@WeldingandNDT2 жыл бұрын
Thank you. Please join my channel to support my initiative. Joining Link: kzbin.info/door/H7nXSievFlbRKzKzEySbkwjoin
@nirmalsurendranmenon7049 Жыл бұрын
Tanks undergo Hydro Pneumatic Test. So how is the test pressure calculated for Hydro Pneumatic?
@ভালোথেকোবন্ধু-স৯ঘ3 жыл бұрын
Sir, please make a video for the reason of selecting the pressure gauge having the minimum and maximum limit of reading between 1.5 to 4 times of the test pressure . Also the capacity of the PSV/PRV with reason. Why are two pressure gauge needed ?
@devkumar-gk2bo4 жыл бұрын
Guruji .....great explanation...
@saleeshmadhavan60772 жыл бұрын
Sir, set pressure for PRV ? Chloride content of water used for SS ?
@haleelimprove4 жыл бұрын
Super sir.. Watching your videos and also your websites 👍🏻 good work
@WeldingandNDT4 жыл бұрын
Thank you so much 🙂
@Infoten_K4 жыл бұрын
Excellent explain sir.. thank you
@WeldingandNDT4 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@saurabhsurti10754 жыл бұрын
Is there any particular quality water required when we are carried hydro test in stainless steel components??
@NIKHILJADHAV3334 жыл бұрын
Demineralised water
@qismatali40732 жыл бұрын
@@NIKHILJADHAV333 as per SAES-A-007 water for SS should below 50pPM chloride conc. And PH value greater than 5.5
@ilangkumarkumar3774 жыл бұрын
Dear sir, Nice stuff. I knew the holding time is 10 minutes as per B 31.3, but 6 minutes per centimetre of thickness and 2hrs maximum. Could you please provide me reference?
@adhwaafiq71593 жыл бұрын
Easy to understand..thanks for the knowledge.
@WeldingandNDT3 жыл бұрын
Thank you. Please join my channel to watch all videos. Joining Link: kzbin.info/door/H7nXSievFlbRKzKzEySbkwjoin
@manushareddy47073 жыл бұрын
Wonderful video sir.. Thank u
@WeldingandNDT3 жыл бұрын
Thank you. Please join my channel to watch all the videos. Joining link: kzbin.info/door/H7nXSievFlbRKzKzEySbkwjoin
@humenbot243 жыл бұрын
Sir, please upload more videos consisting of industrial knowledge. It helps freshers to view and learn for entering the industry. This way we can make our set of knowledge to enter companies and make a better career.
@mistermhw2 жыл бұрын
Hi, if you don't mind, please also visit my channel, maybe it can take more information and education
@harerhdesai5324 Жыл бұрын
Nice presentation 👌
@WeldingandNDT Жыл бұрын
Thank you. Please join my channel to support my initiative. Joining link: kzbin.info/door/H7nXSievFlbRKzKzEySbkwjoin
@mohammadshabbir75243 жыл бұрын
THANKS SIR VERY GOOD EXPLANATION....KINDLY MAKE MORE...VERY HELPFULL THANKS
@WeldingandNDT3 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@saurabhsurti10754 жыл бұрын
Great lecture sir!!
@WeldingandNDT4 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@omprakashmiddi61644 жыл бұрын
How much pressure drop allowed in Piping? What is the calculation for Piping systems? How to select the pressure gauges?
@WeldingandNDT4 жыл бұрын
no pressure drop, pressure gauge selection explained in this video itself
@omprakashmiddi61644 жыл бұрын
@@WeldingandNDTThanks for your prompt response. What about due to temp. & lengthy piping systems difference. I faced a problem like this.
@ranjanprakash914 жыл бұрын
ASME SEC. VIII DIV.1 -UG -102 & 99 FOR MORE INFO.
@muhammadbilawal80754 жыл бұрын
Does hydro test comes under metallurgy / material science technology?
@kafeelahmad98034 жыл бұрын
from where you are taking the value 118 and 138
@Allinone143764 жыл бұрын
Language is very good and very good info sir...
@WeldingandNDT4 жыл бұрын
So nice of you
@vivekjindal14994 жыл бұрын
Sir, calculation of Hydro pressure is same EN standard or different calculation?? kindly explain on this
@munnakaka39074 жыл бұрын
I'm requesting for you please make this topic and other videos in Hindi language. I'm understanding but my some friends not understand. This video knowledge full video. Thanks for this.
@WeldingandNDT4 жыл бұрын
Hindi version of all videos are available. Except this topic, which will be uploaded in Aug/Sep. Thank you. Please visit my website www.weldingandndt.com/
@qismatali40732 жыл бұрын
Sir, how to calculate pressure for process piping.
@saddamhussain-br9gz4 жыл бұрын
as per b31.3 which formula is to be use
@unclejamesx98083 жыл бұрын
Very nice. Thank you sir
@WeldingandNDT3 жыл бұрын
Thank you. Please join my channel to watch all the videos. Joining Link: kzbin.info/door/H7nXSievFlbRKzKzEySbkwjoin
@NavinKumar-tb5lr22 күн бұрын
Can you show the stress value of material in asme 2 part d
@pradeepreddy86514 жыл бұрын
Very nice explanation sir Tqvery much
@WeldingandNDT4 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@vikeshpatel88014 жыл бұрын
Sir,If pressure increased?
@amazingvideos93704 жыл бұрын
This session is very good Plz upload hydrotrst checklist and describe.
@NiranjanMehta14 жыл бұрын
Very good. Keep making more such video
@WeldingandNDT4 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@victors84564 жыл бұрын
Sir During hydro how much pressure difference allowed in two pressure gauges?
@qismatali40732 жыл бұрын
I guess 5% different is allowed if different heights
@saanbk72583 жыл бұрын
Sir how you get St 138 n Sd 133 please reply
@rupakdey14783 жыл бұрын
Sir, please discuss pump selection criteria during hydraulic test
@himagiriparasingi81424 жыл бұрын
Thankyou sir. Very good explanation.
@WeldingandNDT4 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@arunr36954 жыл бұрын
Sir, If we have a system with 90m height. Due to the height variations in pressure gauge reading arises. And how much difference between both gauges is allowed? And in section where it is mentioned? Thanks
@rahulahir77753 жыл бұрын
Really really helpful
@arvindchauhan54 Жыл бұрын
Sir loop file kaise bnate h oske upe videos daliye n🙏
@santoshrana17854 жыл бұрын
Sir Hydrotest me guaje ka selection kaise karege pls guide me....
@erikzeynl43473 жыл бұрын
Thank you detailed explanation.
@WeldingandNDT3 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@saddamhussain-br9gz4 жыл бұрын
When will come part 2 video sir
@qismatali40732 жыл бұрын
Sir, thank you for your efforts. Could you please guide how to prepare safety instruction sheet for process piping?
@WeldingandNDT2 жыл бұрын
Sure. Thank you. Please join my channel to watch all the videos. Joining Link: kzbin.info/door/H7nXSievFlbRKzKzEySbkwjoin
@khurshedansari95984 жыл бұрын
Pressure drop kitne limit tk acceptable hota hai aur kis condition mei aur calculation kase krte hain ki kitna water hai pipe mei
@WeldingandNDT4 жыл бұрын
no pressure drop
@khurshedansari95984 жыл бұрын
Sir calculation kase krte hain ki pipe mei kitna water hai
@souravbohrays41894 жыл бұрын
no pressure drop allowed but in piping if pressure exceed than the max pressure than can release upto hydrostatic test pressure than again hold
@ranjanprakash914 жыл бұрын
Theoretical volume of pipe Vt= (ID)^2/4*π*Length of pipe in (m) Where, I -internal dia of pipe π-3.14
@khurshedansari95984 жыл бұрын
@@ranjanprakash91 Dear fd please details in brief plz..
@venkateshgondu26453 жыл бұрын
How to get pdf files of this topics
@sksaddamhussainofficials69714 жыл бұрын
How to know pipe is fully full
@er.kiran.mt153 жыл бұрын
Sir how to see St & Sd?
@sksaddamhussainofficials69714 жыл бұрын
How to calculate water volume in sylender
@yme99804 жыл бұрын
How much pressure drop is allowed during pressure test after reaching test pressure?
@WeldingandNDT4 жыл бұрын
No pressure drop
@vasanthakumar-nv9fq2 жыл бұрын
Sir super explanation thank u so much sir
@WeldingandNDT2 жыл бұрын
Thank you. Please join my channel to support me. Joining Link: kzbin.info/door/H7nXSievFlbRKzKzEySbkwjoin
@chhatrapatishivaji72124 жыл бұрын
Very useful video sir..
@WeldingandNDT4 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@rohitpatil37804 жыл бұрын
Thanks sir for explaining about hydro tesr.similarlyvrequesting you to guide about air test or pneumatic test.
@WeldingandNDT4 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@viswanath313 жыл бұрын
When to include bolting
@tushantpulkanthwar12004 жыл бұрын
Great video.... Thanks....
@WeldingandNDT4 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@nirmalsurendranmenon70494 жыл бұрын
Sir why are you taking ASME Sec VIII Div 1 and not B31.3?
@WeldingandNDT4 жыл бұрын
For PV. Thank you. Please visit my website www.weldingandndt.com/
@nirmalsurendranmenon7049 Жыл бұрын
This is applicable for Pressure Vessels only
@pradeeps91524 жыл бұрын
How to find Test water temp
@arunr36954 жыл бұрын
We can check temperature using thermometer at the pump area or at vent line
@mohan123574 жыл бұрын
Well explained sir
@WeldingandNDT4 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@krkumaran37183 жыл бұрын
good explanation
@WeldingandNDT2 жыл бұрын
Thank you. Please join my channel to watch all the videos. Joining Link: kzbin.info/door/H7nXSievFlbRKzKzEySbkwjoin
@nikhildaunderiya39444 жыл бұрын
Pls upload single video related painting and blasting.
@lokeshmanjhi4 жыл бұрын
Sir, please explain about Overlay welding in your style..
@narasimhabhagavatula83603 жыл бұрын
The main problem is isolation fittings calclations for safe testing
@mohammedamjad39783 жыл бұрын
Really excellent presentation.Thank you boss.
@WeldingandNDT3 жыл бұрын
Thank you. Please join my channel to watch the members-only exclusive videos. Here is the link: kzbin.info/door/H7nXSievFlbRKzKzEySbkwjoin
@parisworld53434 жыл бұрын
add Valve helium leka test by hood method as per asme sec.v
@kausarraza84484 жыл бұрын
Sir where could I get the ST/SD Data Please explain
@WeldingandNDT4 жыл бұрын
ASME sec 2
@rajasekharbarla61794 жыл бұрын
Sir ji please do pratictical vedio on hydro test
@jiyaslittleworld95984 жыл бұрын
Nice video sir ji
@WeldingandNDT4 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@vinodbhosale21034 жыл бұрын
Sir you are superb
@WeldingandNDT4 жыл бұрын
Thank you
@JavedAlam-gy6vt4 жыл бұрын
Sir Please Explain how to calculate welding consumable...
@WeldingandNDT4 жыл бұрын
Already explained in one of my video. Please check into the playlist. Thank you. Please visit my website www.weldingandndt.com/
@legendsyamokkaElephant2 жыл бұрын
Thnks sir🙏🙏🙏
@WeldingandNDT2 жыл бұрын
Acceptance Criteria video also available on my channel. Please check into the playlist. Thank you. Please join my channel to support my initiative. Joining Link: kzbin.info/door/H7nXSievFlbRKzKzEySbkwjoin
@abdullaar35904 жыл бұрын
Sir where can I get ASME book
@WeldingandNDT4 жыл бұрын
It's not free. But you can download pirated version from telegram. Thank you. Please visit my website www.weldingandndt.com/
@nreependrakumar3953 жыл бұрын
Sir pls help me with another video how to Known st and sd value in MPA from different different sections.pls clarify about It sir 🙏
@WeldingandNDT3 жыл бұрын
Thank you. Please join my channel to watch all the videos. Joining link: kzbin.info/door/H7nXSievFlbRKzKzEySbkwjoin
@chakradharpradhan3574 жыл бұрын
Sir different stainless electrode ki video banaea with sample
@WeldingandNDT4 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@akashvimal92223 жыл бұрын
Good sir
@WeldingandNDT3 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@rc71474 жыл бұрын
Sir first comment 😎
@WeldingandNDT4 жыл бұрын
Super
@sahebhussain85034 жыл бұрын
@@WeldingandNDT sir can you explain according to API 1104.because in pipeline hydrotst is very important ..it's request kindly go through pipeline
@deepeshraghwani34434 жыл бұрын
Sir plz continue RT session.. we r waiting from long period..
@WeldingandNDT4 жыл бұрын
Thank you, but so far the numbers are not encouraging so I have dropped the plan. I may plan in future, if the watch time will improved. Please visit my website www.weldingandndt.com/
@deepeshraghwani34434 жыл бұрын
@@WeldingandNDT k. We got it.. we were started a whatsapp group at international level for welding and ndt purpose. If u want to join plz msg me personally
@mohammadshahalamhussain.ss37673 жыл бұрын
@@deepeshraghwani3443 brother any telegram channels?
@TheAlamshamshad3 жыл бұрын
Bro can you send me pdf of LSR
@khurshedansari95984 жыл бұрын
Sir please Gas pipe line ka hydro test aur calculation aur water removing ka full details video bnaiye plz
@WeldingandNDT4 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@engineersoutlook74 жыл бұрын
Nice
@WeldingandNDT4 жыл бұрын
Thank you. Please visit my website for notes, videos and other important informations www.weldingandndt.com/
@souravbohrays41894 жыл бұрын
non flamable,non toxic liquid,weld joint should be free of any kind of masking,temprature of metal,temprature should be monitor ,pressure guage should pe as per spec,only 1 required which should be clearly visible and readible to inspector,pressure guage should be callibrated with master guage should be callibrated from nabl approved lab,manifold should be callibrated,vent should be at top and drain at bottom, air pessage should be check during draining,guage should be placed at top most position of equipment,all welding ,fitup,heat treatment ,ndt should be done before hydro test,for vertical pressure additional static head pressure should be add ,hydro area should be isolated,hydrostatic test to check aginst stress due to internal pressure for external pressure vaccum testing to be done,for ss chloride content is must
@souravbohrays41894 жыл бұрын
now this video is complete.
@abdullaar35904 жыл бұрын
Sir can I get your WhatsApp number
@WeldingandNDT4 жыл бұрын
Thank you. Please visit my website www.weldingandndt.com/
@ketankanojiya98913 жыл бұрын
@@souravbohrays4189 can you share your contact details pls