Thank you so very much our installer left us nothing no manual or instructions how it works and what to look for .
@pats893
@pats893 Жыл бұрын
Tutorial yg amat jelas dan bermanfaat ,trima kasih ...
@ak29491
@ak29491 6 ай бұрын
Thanks for very helpful and informative video
@FilterShopZa
@FilterShopZa 6 ай бұрын
Glad it was helpful!
@arrianpascual8346
@arrianpascual8346 5 жыл бұрын
Hi. Thank you for the video, it is really helpful. but I only have 1 question, If I have a water refilling station and atleast 70-100 containers a day. How many days does it need for the backwash/regeneration? as of now I set it to 5 days. But not sure if it is correct
@semiusefulinformation144
@semiusefulinformation144 5 жыл бұрын
It will completely depend on your water quality and what the rest of your system is.
@arrianpascual8346
@arrianpascual8346 5 жыл бұрын
@@semiusefulinformation144 Thank you for your reply, I have dual membrane and I'm producing purified water. I also have these 3 levels of filtering, Water Softener, Carbon Media Filter, and Multi Media Filter. its a 24 stages water system
@0837739644
@0837739644 2 жыл бұрын
I'm using this head with tennin removal resin. Is the any way I can set the head to regenerate more than once a day? Tnx Yasin Cape Town Siuth Africa
@vikasbrahmavar122
@vikasbrahmavar122 5 жыл бұрын
Hi...Thanks for the video...very useful..Can we do the setting for regeneration once in say 3000 Lts instead of number days...
@edgarchristiancabilan3635
@edgarchristiancabilan3635 3 жыл бұрын
If the day of the backwash is 00 does it still do the backwash process?
@منالحياةاليمنية
@منالحياةاليمنية 4 жыл бұрын
Thank you, can i do the backwash manul as i need in any time?
@jamir1915
@jamir1915 5 жыл бұрын
What was the causing the purified water become salty after backwash.
@chriscars3578
@chriscars3578 4 жыл бұрын
Thanks for the video great 👍👍👍👍
@johancj4810
@johancj4810 Жыл бұрын
Good day I got F71Q1. How must I program iron removal. If you can help please
@FilterShopZa
@FilterShopZa Жыл бұрын
Hi, what media are you using?
@WilliamGrabCar
@WilliamGrabCar 8 ай бұрын
i have a problem about setting the softener automatic valve for supply boiler water cap 1 ton/hour could u suggest the best cycle for regeneration,backwash until rinse
@FilterShopZa
@FilterShopZa 8 ай бұрын
Hi, the amount of time for each cycle will depend on your water quality. A good start is to run it till you find that your still getting some hardness after the softener and then set a interval that is about 30% shorter than it took to get to that point.
@Amazingdecora
@Amazingdecora 2 жыл бұрын
Is this timer type or meter type?
@MarkAnthonyRushe
@MarkAnthonyRushe Ай бұрын
Ive noticed since our power went that our salt isnt getting used and lime is coming in. All my settings are set as the video but when i try to firce a regeneration nothing happens
@FilterShopZa
@FilterShopZa 7 күн бұрын
That doesn't sound right, is the valve head giving any errors? Also check if the valve in the brine tank isn't stuck in a closed position.
@narsshop4981
@narsshop4981 Жыл бұрын
Is day 7= Sunday?
@rajpalmesh
@rajpalmesh 2 жыл бұрын
hows the performance of this valve ?
@deniceomondi5489
@deniceomondi5489 4 жыл бұрын
Hi my regeneration lamp keeps on flushing but when I tried forced regeneration it's not going thru what could be the problem same modelF63B1
@jepprhona1903
@jepprhona1903 4 жыл бұрын
Hi boss. How do we fix -E1- error with continuous beep? Thank you.
@ed-liem
@ed-liem 6 ай бұрын
What are the factory standard minutes for each stage assuming normal operation
@FilterShopZa
@FilterShopZa 6 ай бұрын
Hi, I think Backwash is 30min, regen 45min, brine refill 15min, Fast rinse is 10min. You would however want to set them to your specific situation.
@paweostanski4167
@paweostanski4167 5 жыл бұрын
Hi,I finnaly know how to set it.Tho what do the green stripes indicate, and those it matter if they are green and red?,thx
@FilterShopZa
@FilterShopZa 5 жыл бұрын
The stripes moving is just an indication that it is in operation, as such a different colour might just be model dependent. Glad the video could help you with the setup.
@lajjapatel3128
@lajjapatel3128 5 жыл бұрын
My valve has stopped showing change in the water level while in operation. Why so?
@sandygrant-taylor8819
@sandygrant-taylor8819 11 ай бұрын
If i have a tank for filtering and a second tank for the cationic resin, can i set the the regen and refill to 0 minutes?
@FilterShopZa
@FilterShopZa 11 ай бұрын
If you set it to zero minutes then your never going to regenerate the resin and it will get depleted very quickly.
@sandygrant-taylor8819
@sandygrant-taylor8819 11 ай бұрын
@@FilterShopZa This is only the the tank that I'm using for filtering, not softening. It's it ok for that. I get a small amount of water coming out the brine port.
@FilterShopZa
@FilterShopZa 11 ай бұрын
@@sandygrant-taylor8819 Hi, That sounds like the valve head isn't sealing properly internally. If you never use the brine refill or regeneration modes you should be able to seal it off to prevent the water leaking, if it is connected to a brine tank there is normally a float valve at the other end.
@MaGrasya27
@MaGrasya27 3 жыл бұрын
In case there's a power interruption for a long time, will it default the program?
@semiusefulinformation144
@semiusefulinformation144 3 жыл бұрын
It normally keeps its program for about a day of no power.
@diosdadoc.espiritujr.2844
@diosdadoc.espiritujr.2844 4 жыл бұрын
Our F26b1 do not proceed to normal operation screen, it just continuously display the start up screen where all part of the screen is lit and after which showing the model then cycles from then on. Is my F26b1 needs to be replace? or is there a way to reset the entire program? thank you for your reply
@semiusefulinformation144
@semiusefulinformation144 4 жыл бұрын
Hi, Check for an agent in your country, they should be able to check it for you. You are normally able to replace just the damaged component and then don't need to replace the whole valve.
@krisztiangyorgymolnar7355
@krisztiangyorgymolnar7355 Жыл бұрын
Hi! Isn't the regeneration time short? 60 minutes is a lot, but the set 1 is not enough. There is no time to absorb the correct amount of salt water from the tank. I don't want to tease, I just want to help. Have a nice day everyone.
@FilterShopZa
@FilterShopZa Жыл бұрын
Hi, you would want to it just to run long enough to empty the brine tank. The time will vary depending on the pressure in your line and the size of your brine tank.
@krisztiangyorgymolnar7355
@krisztiangyorgymolnar7355 Жыл бұрын
@@FilterShopZa Thank You for your answer.
@coldwind70
@coldwind70 7 жыл бұрын
If power is OFF to the controller while in SERVICE mode, will it maintain at SERVICE mode valve opening?
@damienfynn1522
@damienfynn1522 7 жыл бұрын
LW Ling , yes it will stay in service mode if the power is off.
@KoraputiaHasahasi
@KoraputiaHasahasi 3 жыл бұрын
How can i set Automatic Regeneration on this?
@glennmataragnon1409
@glennmataragnon1409 10 ай бұрын
What does the brine refill time means?
@FilterShopZa
@FilterShopZa 9 ай бұрын
It is for refilling the brine tank where you would add salt.
@chrissiwu7616
@chrissiwu7616 3 жыл бұрын
I had -e2- in my monitor? Can i fix it?
@changemakers622
@changemakers622 Жыл бұрын
What is E-3 in mpv
@linehougaard1397
@linehougaard1397 3 жыл бұрын
I can’t go into the A-01 option and brother the H options. And I can’t put on the hardness of the water? What to do?
@loriusseanafack401
@loriusseanafack401 Жыл бұрын
Please for the manual guide ( pdf or link)
@FilterShopZa
@FilterShopZa Жыл бұрын
There is a nice description here: filtershop.co.za/en/pg-purifier-of-water
@tayoa1368
@tayoa1368 5 жыл бұрын
How to clean manual?
@charlottedayto2276
@charlottedayto2276 2 жыл бұрын
Hello how to fix E4
@wsstczambo8577
@wsstczambo8577 7 жыл бұрын
how to reset it.....?
@darrenryall1995
@darrenryall1995 7 жыл бұрын
You can Reset it to factory settings, by disconnecting it from power for more than three days. Not sure if you can reset it manually.
@KidanuDagnew
@KidanuDagnew 11 күн бұрын
kid
F63B3 Softener Valvehead Setup
12:30
FilterShop
Рет қаралды 30 М.
7500 Control Valve Programming
9:44
Clean Water Store
Рет қаралды 22 М.
Family Love #funny #sigma
00:16
CRAZY GREAPA
Рет қаралды 31 МЛН
Não sabe esconder Comida
00:20
DUDU e CAROL
Рет қаралды 63 МЛН
ЛУЧШИЙ ФОКУС + секрет! #shorts
00:12
Роман Magic
Рет қаралды 22 МЛН
Perfect Pitch Challenge? Easy! 🎤😎| Free Fire Official
00:13
Garena Free Fire Global
Рет қаралды 51 МЛН
Настройка клапана умягчителя RUNXIN F65B3 - первый вариант
17:37
Очистка Воды Отопление Водоснабжение
Рет қаралды 76 М.
How to Program a Tier1 165-150 48,000 Grain Water Softener Valve
4:56
Tier1 Water and Air Filtration
Рет қаралды 17 М.
Programowanie głowicy i uruchomienie zmiękczacza Hydro Plus
8:37
Technika Wody Zmiękczacze i filtry
Рет қаралды 57 М.
F67B1 Automatic Backwash valve head
6:49
FilterShop
Рет қаралды 101 М.
setting runxin valve F67C1
5:51
فكره اونلاين
Рет қаралды 5 М.
Ablandador de agua cabezal simple
6:39
Jaime Ocampo
Рет қаралды 27 М.
HƯỚNG DẪN SỬ DỤNG AUTOVALVE RUNXIN F63/F71 - 0421
5:40
HOANCAUTECH
Рет қаралды 2,9 М.
F63P3 Runxin Automatic Softener Valve Programming Video.
8:27
WE LOVE LIFE !!!
Рет қаралды 1,7 М.
Runxin  yumuşatma valfi
9:40
Gökhan CİNGÖZ
Рет қаралды 8 М.
Family Love #funny #sigma
00:16
CRAZY GREAPA
Рет қаралды 31 МЛН