F63B3 Softener Valvehead Setup

  Рет қаралды 31,574

FilterShop

FilterShop

Күн бұрын

Пікірлер: 22
@g9rahul854
@g9rahul854 4 жыл бұрын
This video was very helpful, thank you for your explanation
@kristelerono
@kristelerono 3 жыл бұрын
how to reset it?
@marktunstall4577
@marktunstall4577 4 жыл бұрын
Thank you. Very concise explanation
@rajpalmesh
@rajpalmesh 2 жыл бұрын
How reliable are these valves and how long do they last avg life ? Thanks for the video.
@captainissy
@captainissy Жыл бұрын
What happens if we have both this one and the other one? How do we go about setting them? Should they be the same?
@donnaktowler4298
@donnaktowler4298 3 жыл бұрын
Your video has been very helpful. I am probably just missing something but can use your help. How do I know how much water we are using in order to set the number of days between regeneration? I hope i am asking this correctly. I have set it as 7 days at this point but may be too often but not exactly sure how decide the correct setting. Thank you.
@semiusefulinformation144
@semiusefulinformation144 3 жыл бұрын
The easiest is to test the water for hardness with a test strip just before the regeneration. If you have no hardness yet extend the interval, if you have a lot of hardness then shorten the interval.
@billypo_29
@billypo_29 3 жыл бұрын
Thank you, this video very helpful.. 👍
@angelalouiesia1556
@angelalouiesia1556 4 жыл бұрын
is the volume per min or hour per day?
@NSK8700
@NSK8700 5 жыл бұрын
Has the F63B3, evolved to newer Models suitable for Aventura's 1054 size vessels ? These seem new Models: F65B3 or F65C or F69A3 or F69C ( as current?)
@guisilvac
@guisilvac 3 жыл бұрын
Good Morning. Could you help me where to find to sell the Flow sensor?
@jansam71
@jansam71 3 жыл бұрын
Hi, I have F63B3 installed. Overhead tank is connected to underground tank with sensors for automatic functionality. Only issue i do see is , at the time of regeneration, if overhead tank is full, water pump doesn't run which makes regeneration steps doesn't work. How do we overcome with this? are there any settings to be changed?
@semiusefulinformation144
@semiusefulinformation144 3 жыл бұрын
Hi, Do you have a pump from the overhead tank? You need at least 2 bar pressure for the valves regeneration to function, so if it is from a tank it would need to be 20M up.
@tejasjagtap2908
@tejasjagtap2908 5 жыл бұрын
Sir, can we use this Auto multiport valve for the sand filter & carbon filter..if yes..then what about regeneration setting?? I think their is no require of regeneration to sand filter and carbon filter..only back wash , slow & fast rinses are required.. then what should do about regeneration setting..plz sir suggest me.
@renielbandong3984
@renielbandong3984 5 жыл бұрын
What are the steps for trial running after installation?
@rahulbhalerao2334
@rahulbhalerao2334 6 жыл бұрын
He nice explanation ..Thank you
@jetsonharvey542
@jetsonharvey542 6 жыл бұрын
Can you explain to me what happens during the fast rinse?
@darrenryall3402
@darrenryall3402 6 жыл бұрын
Hi, during the fast rinse, the softener resin is pushed back down into place at the bottom of the Vessel in preparation for normal operation. During this process, any excess salt is also flushed out to the drain point.
@jetsonharvey542
@jetsonharvey542 6 жыл бұрын
Thanks, that really helped!
@jepprhona1903
@jepprhona1903 4 жыл бұрын
Hello, how to fix the -E1- error and it continues to beep.
@pandeyvijay2896
@pandeyvijay2896 7 ай бұрын
Same. Problem
@alfredochuquimia4441
@alfredochuquimia4441 5 жыл бұрын
seria muy amable de realizarlo en español
F63B1 Softener Valve Head
14:25
FilterShop
Рет қаралды 63 М.
Softener Setup
10:45
FilterShop
Рет қаралды 20 М.
-5+3은 뭔가요? 📚 #shorts
0:19
5 분 Tricks
Рет қаралды 13 МЛН
Настройка блока Runxin F63P3 для умягчения воды
17:23
Компания АкваМир
Рет қаралды 55 М.
RUNXIN F67B1 Настройка клапана управления.
14:34
AQUATEM Технологии
Рет қаралды 11 М.
Inside the V3 Nazi Super Gun
19:52
Blue Paw Print
Рет қаралды 2,2 МЛН
F63P3 Runxin Automatic Softener Valve Programming Video.
8:27
WE LOVE LIFE !!!
Рет қаралды 2 М.
90% of Toilets Are Installed Wrong (Here’s the Right Way)
16:04
Home RenoVision DIY
Рет қаралды 2,6 МЛН
Tutorial - Cabeçote Automático F63B3 Automatic Valve Head RunXin
6:43
7500 Control Valve Programming
9:44
Clean Water Store
Рет қаралды 23 М.
-5+3은 뭔가요? 📚 #shorts
0:19
5 분 Tricks
Рет қаралды 13 МЛН