"No valid atomic position available" error happens, when the structural information is not available in the select JCPDS card. In this video, I have shown how to get rid of the error “No valid atomic position available” when performing Rietveld refinement. If you have any questions, ask them in the comment section below. For more videos, please subscribe to NanoWorld. Thank you.
#NanoWorld
______________________________________
For more updates follow us on,
Facebook: / fascinatingnanoworld
Twitter: / nanoworld8
Instagram: / nanoworld85
Contact: fascinatingnanoworld@gmail.com
______________________________________
Interpretation of SAED pattern | estimation of d-spacing & (khl) values
• Interpretation of SAED...
How to put a scale bar on SEM & TEM images (SEM/TEM data analysis)
• How to put a scale bar...
No valid atomic position available (Rietveld refinement through X’pert Highscore)
• Fixing of valid atomic...
Negative intensities in scan data points (Rietveld refinement through X’pert Highscore)
• Fixing of Negative int...
Indexing XRD peaks with Miller indices (hkl) values using X’pert Highscore software
• Indexing XRD peaks wit...
How to plot JCPDS card with the XRD data using OriginLab software
• How to plot JCPDS card...
XRD data analysis using X’pert Highscore software
• XRD data analysis usin...
Deconvolution of photoluminescence PL spectra (PL peaks fitting)
• Deconvolution of photo...
How to find peak position and FWHM of XRD data
• How to find peak posit...
How to calculate crystallites (grain) size from XRD data?
• Crystallites (grain) s...
Estimation of grain size through modifies Scherrer equation
• Grain (crystallites) s...
Crystallites size and strain using W-H plot method
• crystallites (grain) s...
Calculation of nanoparticle size through SEM image
• nanoparticles size fro...
How to find Miller indices of XRD peaks?
• How to label XRD peaks...
How to calculate d-spacing from XRD data?
• How to calculate d-spa...
How to calculate lattice constant (a, b, c) values from the XRD data?
• How to calculate latti...
How to calculate microstrain and dislocation density from XRD data?
• strain and dislocation...
How to calculate crystallinity from XRD data?
• how to calculate cryst...
How to smooth XRD data?
• How to smooth data (XR...
Baseline correction for XRD data
• Baseline correction fo...
Cyclic Voltammetry Data Analysis
• CV Data Analysis throu...
How to find bandgap energy using the Tauc plot method?
• Band gap energy from a...
How to calculate bandgap energy using the Kubelka Munk function?
• Bandgap energy using K...
Understanding Tauc plot, 1240 (constant) and 2.303 constant
• Band gap energy (Tauc ...
How to know a material either have direct or indirect bandgap energy?
• How to know a material...
DSC Data Analysis
• DSC Analysis Through O...
TGA Data Analysis
• TGA Analysis Through O...
How to plot the double Y-axis in a single graph?
• TGA & DSC double plot ...
Electron paramagnetic resonance (EPR) data analysis (calculation of g-factor)
• Electron paramagnetic ...
_________________________________________
Music Source
Unconditionally by Broken Elegance 🎩 / brokenelegance Creative Commons - Attribution 3.0 Unported - CC BY 3.0 creativecommons.org/licenses/b... Music promoted by Audio Library • Unconditionally - Brok...

Пікірлер: 38
@shreyjain6447
@shreyjain6447 3 жыл бұрын
Gr8 vid. One question, why does skip patterns without structure data does not appear?
@imadafghan6825
@imadafghan6825 3 жыл бұрын
genius piece of work sir and new comer researchers will pay tribute to you always. Thanks
@nanoworld6122
@nanoworld6122 3 жыл бұрын
Many thanks
@VersatileProfessors
@VersatileProfessors 3 жыл бұрын
Great Work......... Keep It up.... I'll encourage you......... Background music is also sooooooooooooo soft.
@monicamariagomezhermida6980
@monicamariagomezhermida6980 3 жыл бұрын
Hello, thanks for this videos, but i dont have jcpds with atomic positions, can i put this manually or can i load a cif with this positions?
@iceiceq2369
@iceiceq2369 3 жыл бұрын
How to export the fitting results (as data)? So I can replot them in other softwares.
@suleymangokhancolak8747
@suleymangokhancolak8747 3 жыл бұрын
Hello, when I do a rietveld analysis, I encounter the warning "No structural data for simulation/refinement." Do you know why this problem occurs?
@wasim6370
@wasim6370 Жыл бұрын
facing the same problem......do you know how to resolve it
@suleymangokhancolak8747
@suleymangokhancolak8747 Жыл бұрын
@@wasim6370 I'm still searching sorry😔
@user-xb5sl8xz9h
@user-xb5sl8xz9h 4 ай бұрын
please help me how to resolve that issue. it desn"t have any function about skip data without structural information.
@madamostafa1455
@madamostafa1455 3 жыл бұрын
I have problem the skip of non structure data icon didn't exist in the list of the icons the last icon is skip of non reference pattern how can i add this tap to to calculation
@medagmedhin3509
@medagmedhin3509 Жыл бұрын
What exactly are you doing when you drag and drop the Origin file into the X'pert high score? does the Origin file contain the data or the graph for the ZnO?
@adrpcomputer3998
@adrpcomputer3998 3 жыл бұрын
Sir along with this error I have one more stating too many data points for reitveld module. How to solve it ?
@exactlykot
@exactlykot 2 жыл бұрын
in anchor data sheet which one is Bragg position?
@rajprasad3991
@rajprasad3991 2 жыл бұрын
hello sir, even after doing the same method, the structural data is not shown. any idea why this happens?
@harry-ho9ti
@harry-ho9ti 3 жыл бұрын
Sir could you please make a video on how to draw crystal structure using diamond software?
@mbhiccvv1620
@mbhiccvv1620 Жыл бұрын
Hello, can you provide us with ICSD Database for HighScore. Thank you
@smitanand1836
@smitanand1836 2 жыл бұрын
kindly provide the link of your current version of xpert highscore software
@yulissaramirezgarcia9408
@yulissaramirezgarcia9408 3 жыл бұрын
Hello and thanks for the video. Do you know why the option "skip patterns without structure data" does not appaer? I really appreciate your help :c
@nanoworld6122
@nanoworld6122 3 жыл бұрын
What version of the software you are using? I'm using 3.05. the problem maybe due to the different version.
@itanruiz7828
@itanruiz7828 3 жыл бұрын
@@nanoworld6122 Hello. I'm using the version 3.0. But it doesn't have the option for "Skip patterns without structure data".
@hemapalleth7687
@hemapalleth7687 2 жыл бұрын
When we skip patterns without reference scan the search result as no candidate found. Plse do help sir
@williamsflores3582
@williamsflores3582 Жыл бұрын
Someone have the 3.0.5 versión? I dont found in the Web. I need the latest versión please
@exactlykot
@exactlykot 2 жыл бұрын
dear can u make one KZbin Rietveld refinement through X’pert Highscore with Bragg position on Origin software
@physicsofsolidssimulation8941
@physicsofsolidssimulation8941 Жыл бұрын
Hi, please you have file ".ASC" how to change my file ".dat" to ".ASC" ? Because the ".dat" not available
@sakshithakur8927
@sakshithakur8927 Жыл бұрын
I have followed the steps, but in quality tab there is no such option of structural info? whats the issue.. please tell if anyone know about this?
@kavitayadav8351
@kavitayadav8351 3 жыл бұрын
Hello sir , for resolving the problem of no valid atomic position available, the option in quality tab i.e. skip pattern without structural data does not appear, why this is so
@nanoworld6122
@nanoworld6122 3 жыл бұрын
For this, you will need a newer of the software.
@surajsing8131
@surajsing8131 3 жыл бұрын
This option is not available in my expert high score plus software How can I solve this problem ? Plz help
@nanoworld6122
@nanoworld6122 3 жыл бұрын
you need a latest version of the software.
@mathagroups2865
@mathagroups2865 Жыл бұрын
Sir I have selected NIO but no result found varudhu sir.... How can rectify this problem...pls help me
@atiqurkhan1789
@atiqurkhan1789 2 жыл бұрын
'Actual scan axis is not supported for refinement' error showing, please solve it.
@medagmedhin3509
@medagmedhin3509 Жыл бұрын
In the X’pert Highscore software i am using, there is no "skip pattern without structural data" under the "quality"
@MuhammadArshad-qe5ly
@MuhammadArshad-qe5ly Жыл бұрын
I also have the same problem, my HSP not showing me may be mine one is old version of HSP.
@asmasohail7727
@asmasohail7727 2 жыл бұрын
"No structural data for simulation/refinement." plz solve this problem
@nanoworld6122
@nanoworld6122 2 жыл бұрын
have you watched this video? kzbin.info/www/bejne/pqGvoI2sn8yUmpI
@asmasohail7727
@asmasohail7727 2 жыл бұрын
@@nanoworld6122 sir The version of xpert high score plus which I am using has no option of 'skip pattern without structural data'
@thetthetswe3004
@thetthetswe3004 Жыл бұрын
@@nanoworld6122 HI Sir, the problem report for "no structural data for simulation/refinement" is appeared on my screen... pls help how to solve that
XRD data analysis using X'pert highscore software - 23
13:19
NanoWorld
Рет қаралды 89 М.
Clown takes blame for missing candy 🍬🤣 #shorts
00:49
Yoeslan
Рет қаралды 39 МЛН
Little girl's dream of a giant teddy bear is about to come true #shorts
00:32
Playing hide and seek with my dog 🐶
00:25
Zach King
Рет қаралды 32 МЛН
Xpert HighScore Plus-Rietveld Method tutorial 2018
5:46
Engineering Sciences
Рет қаралды 37 М.
XRD Analysis for Phase Determination using X'Pert HighScore Plus
20:12