Still got my old Baxi back boiler installed in 1976. Still working. Just in the process of changing it to a modern boiler. Not a lot to go wrong with the old back boiler as long as it’s serviced. But heho, let’s get into the 21st century. Don’t even know why I watch your videos (as well explained as they are) as I’ve just retired. 😂😂 Keep up the good work for the next generation.
@robincurwood Жыл бұрын
Same here,I retired 2 years ago. My elderly mum, still has a Baxi back boiler installed way back when I was a lad.(1971?) My brother manages her care now as she suffers from dementia.
@leeedwards3783 Жыл бұрын
Great video. Love how clearly you explain it all. Only ever come across one and ended up taking it out.
@bentzionroyde4786 Жыл бұрын
Thanks Derek great video 👍
@stephenmcgrath2976 Жыл бұрын
Really well explained be interesting how you work on a baxi Bermuda back boiler
@tomkatgastraining Жыл бұрын
Love the baxi Bermuda so easy to work on and you knew it would go back together again
@welsh443 Жыл бұрын
Extractor fans on?
@davidproctor6359 Жыл бұрын
thanks 4 ur lesson
@ed3939 ай бұрын
Turned off a 1969 Baxi BBU last week AR, The customer had a conservatory built 6 year ago vent bricked over it passed f/f and spillage no signs of soothing actually in really god condition like new, Customer said other engineers have been and never issued a notice or mentioned ventilation nor did they go in the loft, I really wonder how these guys sleep at night.
@chrisgreen98022 ай бұрын
To tomkat gas training currently renewing my acs and assessor said a sweep test doesn’t exist and u can’t do it
@chrisgreen98022 ай бұрын
Anyone have any thoughts on
@tomkatgastraining2 ай бұрын
@@chrisgreen9802 I would change training centre immediately as the assessor seams not current with the assessment process and gas industry.
@chrisgreen98022 ай бұрын
@@tomkatgastraining thank you but the course for my renewal was booked through company
@ivanhoe636611 ай бұрын
My own boiler, not a plumber/gas fitter, is a Worcester 9.24 electronic open flue combi. 1989
@simonwalton6856 Жыл бұрын
I'm a bit confused there because surely what you've done is the same test twice , because you put the smoke in the same place, one with the alliance not running and one with it running? Shouldn't the flue flow go at the base just past the burner at the start of the primary flue?
@tomkatgastraining Жыл бұрын
No you test at the draft diverter not at the burner. The flue flow and spillage are different test like I say in the video
@pallsmortion4750 Жыл бұрын
The oldest boiler I maintain is a 1964 Powell Duffryn
@tomkatgastraining Жыл бұрын
Winning so far 👍🏻
@nickcannon5592 Жыл бұрын
Potterton janitor International with an SMC Admiral pump