One thing to remember is that it is only the 05 and up that has the failure prone STC fitting. None of the 04's (not even the late 04) have the HPOP discharge fitting that can be corrected w/ the updated one-piece fitting. Also, the truck in the video has a tall oil filter cap. That can be ok w/ the proper filter that comes w/ it, but it can be a problem w/ an OEM filter.
@damianacosta40813 жыл бұрын
Hello my names Damian I am repairing a 350 diesel 6.0 I assembled it the other day I put an engine that I bought it was difficult for him to start after he started I turned it off and turned it on again it started well but after a while I found oil in the water I changed the cooler and the The only way to start it is with being fluid, it starts up and I have to have it above 2000 laps, I let go of the accelerator and it turns off, which may be from now on, thanks and your videos are very good.
@AcombativePYRO7 жыл бұрын
Great video. I have a 2007 6.0 and having serious issues with cold starts. I bought the truck used privately, and the old owner treated it like shit. It's fully bulletproofed but he was using shit oil and shit aftermarket filters for everything. I'm back to motorcraft products along with Amsoil 15w 40 with Hotshot stiction eliminator. My truck Definetly doesn't sound like it runs on all cylinders. I also have 2 codes for 2 of my cylinders that say contribution balance.... it supposedly has the high pressure oil pump connector. But I'm not sure what order I should go in to diagnose and fix this rough ass startup. After fooling for 10 minutes it sound the way it should be.
@cameronguillemaud36537 жыл бұрын
I'm glad there are techs out there to help
@nerio07pstroke10 жыл бұрын
if that gauge doesn't work but u can see the oil coming up .. still no start thamay be the problem I got new hpop n I dont see pressure build up on the icp
@FordTechMakuloco10 жыл бұрын
The gauge should come up after some cranking. If you just replaced the hpop then it will take allot of cranking to fill everything up and fire the engine.
@everber116710 жыл бұрын
Thanks for taking time to make this video.
@89TRX350RX10 жыл бұрын
I appreciate all your videos! Yours are the most informative and easiest to follow. Thanks and keep up the good work, From BigBird!
@FordTechMakuloco10 жыл бұрын
89TRX350RX Wow thanks!
@gregorywells57703 жыл бұрын
@@FordTechMakuloco man I need your help
@grumpy93610 жыл бұрын
Have 2006 F-350 that I just replaced oil cooler on and after all work done it started and let run and went for a little drive and all seemed ok as it had been running for over an hour, I shut it off and left it for the day and it was warm, at least up here, I went to start it and no start situation occurred, brought out snap on scanner and it came up with P2284 code for ICP,checked ICP pressure and it was 189 psi but batteries were running down so my next move would be check solenoid at rear ?? and check as have ben told unit can be bad as it was placed in by ford shop and yes was very clean on cooler replacement.
@FordTechMakuloco10 жыл бұрын
I would go right after the IPR and check the screen and valve very common after repairs clean or not some debri is likely to get missed. No Start: Ford 6.0L Powerstroke IPR Checks
@psd6ohslow11 жыл бұрын
So even if the IPR is bad there won't be no codes? Liking all these 6.0 videos thanks!!
@FordTechMakuloco11 жыл бұрын
I have never seen an ipr code of any sort, it will eventually set the low icp codes though.
@dadmiral52986 жыл бұрын
For the benefit of good understanding I think it will be helpful if you can say what all these abbreviations mean,like the icp,ipr,pcm.By saying them fully it will help to allow others that don't know what they mean understand their full meaning.Thanks.
@matthewdonoho454610 жыл бұрын
got 05 6.0L diesel no start did everything ,pulled injection pump,installed update,replaced fica,still no start,ipr pressure is at 0 no matter how much you crank motor,also replaced batteries for slow cranking
@FordTechMakuloco10 жыл бұрын
Ok so you have base oil pressure according to the gauge? What is the icp reading, and ipr reading during cranking.
@JesusRamirez-ho2oe9 жыл бұрын
Nice video is there a way to bypass the ICP circuit so you could start the engine?
@FordTechMakuloco9 жыл бұрын
+Jesus Ramirez If you disconnect the icp sensor connector while the key is off and goto crank it the pcm will assume 700psi I believe and allow the injectors to fire but there still has to be icp pressure, a working FICM and fuel pressure to fire.
@JesusRamirez-ho2oe9 жыл бұрын
Thanks you for taking the time to answer one more question whats the name of the program you are using thank you fordtechMakuloco
@paulludtke3496 жыл бұрын
So if you can get the engine to run by disconnecting the ICP sensor, what does that tell you? Does that confirm that it is indeed a faulty IPR or a faulty ICP? Or possibly both?
@ninjak26473 жыл бұрын
@@paulludtke349 Did you ever find the answer to this?
@fuelofire5 жыл бұрын
I had a quick question about 6.0 IPR valves. I suspected an IPR that was sticking when I 1) had hot start issues and 2) started to throw codes about Injection Pressure High at idle and it would actually shut the engine off. I replaced it with an aftermarket IPR and now my problem has changed. I now longer have hot start issues, but if I shut the truck off and leave it for more than 4 hours, the oil is leaking out of the oil rails. I'm guessing that since I never had this issue before, and that my hot starts and high pressure codes have been fixed, that I've got an IPR thats functioning when engine is on, but isn't keeping the oil in the High pressure oil system. Is this possible? I don't know enough about why if would leak down overnight but not during operation/hot starts and can only assume that their must be a check valve in the IPR to keep if from draining down when engine is off.
@BearLeeHangin11 ай бұрын
Well damn, now I’m curious and no one answered 😒
@pacheco4642 жыл бұрын
You know a cheapest scanner for diesel ? Tanks in advance for your time
@edwardgarcia64967 жыл бұрын
i have 2006 6.0 f250 turns on when cold little rough then when i leave i dont have alot of power till warms up.....any suggestions what to chase after i bought the fitting for pressure test icp..i just did rebuilt on ipr but didnt check voltage..
@everber116710 жыл бұрын
Thanks for the help I'll keep you posted
@everber116710 жыл бұрын
Yes I saw your video and the icp is on the front of thevalves cover thanks for your help and taking the time to make these videos are really helpfully
@williamskelton67517 жыл бұрын
I have a preference for N2 hydro if HPOP system. Usual test psi NGT 1500PSI.
@aaronlaho81156 жыл бұрын
I have 05 6.0 with an air leak in HPO system truck will run for about 15 minutes than dies, as I monitor icp I can watch it fall off until falls below 400 psi than engine dies. Truck came in for injectors. I replaced all 8 injectors stand pipes and dummy plugs, after that this issue started with engine shutting down after 15 minutes. I can hear air on right side I isolated both oil rails no air leaks. Replace IPR and STC fitting also, when putting air through IPR I can hear air coming from right side I have found it coming valley, do you think I have a branch tube issue?
@SnakebitN1297 жыл бұрын
I need a little help 06 F350 cranks,starts cold, runs for a minute then goes dead restart easy then repeats going dead. It does have a P273 code high voltage to #5 inj.that problem I plan on replacing that injector. All parts I use are Ford or Motorcraft this diesel is to labor intensive to use aftermarket.Thanks for any help ! Paul
@wazzup2987 Жыл бұрын
How can I crank the truck over without the truck starting to see the oil pressure gauge reading to verify the low pressure pump is working? Also, I have the P2290 and P2614 for the cam sensor I believe. Which system should I diagnose first? Both my HPOP and Low pressure oil pump are new as my motor was replaced 3 years ago. My Cam sensor was replaced a few years ago however my crank sensor has not been touched. Thanks!
@loosmaster8 ай бұрын
If you haven't figured it out yet, there is a wire running along the right fender. Near the hood hinge is a quick disconnect. This wire is just for starter engagement. Disconnect and make contact on the positive post of the battery to crank. Don't forget to reattach it.
@Turfgreenpro5 жыл бұрын
Question is the icp in the hpop? Or completely Different ? My truck loses power when driving on the highway it starts jumping throws smoke and dies but once dead it starts back up again and drive it and then again same thing loses power speed starts jumping and die. Any tips? Should I replace the high pressure oil pump ? And the icp? And also fuel pump and filters ?
@Chrisjamesbowe3 жыл бұрын
I have 03 code p2290 at full throttle everything runs perfect starts perfect hot or cold any rec icp ipr are new turbo rebuilt
@OscarGonzalez-ih1vc3 жыл бұрын
I’m at the part where I need to jump my truck and it’s taking forever... lol . My ipr had the screen completely blown off. When i took it out. I also figured an oil change to attempt to drain the debre and new filter
@leeizaak31675 жыл бұрын
Mine doing same thing help me out bro great video mine has new stand pipes and dummy plugs new, pump and injector nipple seals..when I do a air test it leaks slow everythings connected ficm wise, turn key fwd and air changes but doesn't stop completely is this an issue
@JCortes0017 жыл бұрын
where can I find that adapter ?? to pressurize the system
@FordTechMakuloco7 жыл бұрын
All parts and tools are linked to in the video description of all my videos.
@MyBlowncobra3 жыл бұрын
Man I'd love to get my truck I to you...where are you
@andrewstevens92466 жыл бұрын
What usually causes the p2286 code? (Icp circuit high) My truck will not run. Ficm is good, fuel pressure is good, and my sct says I have 1600 icp while cranking.
@Mrg-je5ep7 жыл бұрын
I have a 2004 f250 diesel 6.0. My truck did this around winter time and we cleaned the icp sensor an plugged it back in and it ran up until the other day. Now it is not even cranking. Could the icp sensor be completely done and that's why it won't turn over? It's just clicking. Any advice?
@jwoeltje69496 жыл бұрын
Is it normal after repair to re air test and hear a little air from crankcase? i have the test fitting right in the IPR valve I'm sure its coming from the oil feed side of the pump. I replace the pump and SCT fitting.i also removed valve covers caped oil stand pipes. Its an early 2004
@felipesalas29392 жыл бұрын
i have 05 f250 with 6.0 after i apply power to the ipr and add air to system, i hear a air leak on the high-pressure oil pump dump hole. is that normal or should it be fully sealed after power is added? i hear it really loud when no power is added which i know is normal but leak is less when power added
@arabiangote9 жыл бұрын
I have '03 6.0L no start. Just found ICP voltage is 0.13 with key on engine off. When I crank the motor I don't build any oil pressure. Is this because of the ICP or do I have 2 problems (ICP and LPOP)? Thanks for the videos.
@FordTechMakuloco9 жыл бұрын
Curt Canine Yes you need to fix the low pressure issue first.
@justindaniel50875 ай бұрын
I just replaced my IPR valve it was damaged and had a whole in the screen and my 2007 6.0 still cranks no start all injectors clicking so it may be the IPC?
@viergutze9 жыл бұрын
I need some help, I'm working on an 2006 E-350 with the 6.0. I just finished replacing the intake gaskets, oil cooler, and egr cooler. When finished i started the van and ran it for a solid 2 hours. I then shut itself off, now with a crank-no start condition. Turns over great but will not start. I plugged in our computer the same one you have and ran the same test. i get 293psi on the icp and all the other voltages are within range. what would be your next step in this case? Thanks in advance for your help
@FordTechMakuloco9 жыл бұрын
Eric Viergutz Pull the IPR and inspect the screen it is likely damaged. Replace the ipr and you should be good to go.
@viergutze9 жыл бұрын
FordTechMakuloco Just like you said, took out the IPR and bingo there is a rip in the screen. replaced it and now its good to go. thanks agian
@viergutze9 жыл бұрын
FordTechMakuloco Just like you said, took out the IPR and bingo there is a rip in the screen. replaced it and now its good to go. thanks agian
@waterwater3443 жыл бұрын
So I have a 03 6.0l and my basic scan tool says that is has 410psi at starting and it need 500psi minimum so what do I do there I will try the icp voltage and ipr
@bestvocals3 жыл бұрын
If the cap is missing will that be a problem no start
@chrissepesi42232 жыл бұрын
Awesome video!! Great stuff
@stevenmanning52416 жыл бұрын
i havea 2003 f250 was driving and thought i ran out of fuel went and put 3gals in started up drove 2miles stopped started up and drove 3miles home and it died before i got home just had new injectors and fuel pump put in about 1 year ago the codes read p2614 p2617 p2290 p1000 what to do?
@747fox8 жыл бұрын
hello friend I have a question to work on a f350 2006 replace the seals of the oil cooler and the packaging of the air intake now I try to start the truck have some difficult starts and when it reaches its working temperature , does not start I have the code p2284 , when hot icp brand 0.25V , only 2 psi and 85 % ıpr you can help me
@luis84606 жыл бұрын
Very informative video, thanks. Where can I find that software?
@ryanhogan65094 жыл бұрын
Ford ids eBay has it, there is also a free “forscan”
@michaelhaiden67189 жыл бұрын
what did you do to fix the problem I did not see you change or replace nothing pls help
@FordTechMakuloco9 жыл бұрын
michael haiden This is only a test video it will lead you to the problem. This one required a new IPR I have a video on that also.
@AllThingsRamdom5 жыл бұрын
I have a long start on my truck and once it finally starts it sounds just like that truck did at the end of this video where it runs like crap and then smooths out. This happens anytime I let the truck sit overnight or for a few hours after driving. Anyone know what would cause this issue every time I go to start it when it's sat for a bit? Also it didn't have this hard start issue until after I changed the Turbo. Happened as soon as a new Turbo was put in. Only other time it would have this issue is when I drive down the road if I really put the pedal to the floor, poll a load, go up hills or something like that The truck will start to lose power and then stall completely. After it has stalled by half to weigh a few minutes before it will even start again and it will run my crab just like it did in this video when the truck starts at the end of the video once I started backup when it's having that particular issue. Any ideas on what it could be? By the way this problem with it stalling out and losing power happened before the Turbo so it's been a continuing issue. Sometimes I can even drive the truck for an hour with no problems and then the next day it'll have problems after 5 minutes where it will start to lose power and then completely die on me and run like rap when it starts again.
@JakeMormanRacing4 жыл бұрын
Did you ever figure out this problem?
@everber116710 жыл бұрын
I have a 2004 6.0 some times I shut it off and 5 minutes latter it won't start after trying 3 or 4 times starts right away.oil level is fine and two new batteries do you have any idea how to fix this problem,thanks
@FordTechMakuloco10 жыл бұрын
So it has to be cooled off for it to start? Or hot it will start you just need to try it a few times. Is your icp sensor in the right front valve cover or in the rear?
@everber116710 жыл бұрын
No it doesn't have to cool down just out of the blue starts
@FordTechMakuloco10 жыл бұрын
You mention batteries like this is a no crank is that what it actually is?
@everber116710 жыл бұрын
No I just replace them to have better cranking
@everber116710 жыл бұрын
I checked in the last 7 days after reach its norrmal temperature if shut it off it won't start again until cools down.I notice too that cranking for more than 10 seconds the oil pressure gauge don't muve.any comments thanks
@mikefoster63583 жыл бұрын
I replaced my ICP and IPR. The truck will crank and run, but it won't rev up. IPR reads 85%. Any thoughts
@elmonstro92487 жыл бұрын
hey I have a Ford f350 king ranch that it's starts but want stay on . I replaced the oil cooler now it won't stay on it need help if u can
@Mebob200111 жыл бұрын
so many points for leaks... i HATE it when its the w pipe leaking, you think its the injector seals when its not the nipple on the pipe is leaking... only had one but my fuck i was mad:P
@FordTechMakuloco11 жыл бұрын
I have never changed a branch tube and now since the 6.0l are out of warranty hopefully I never will. The other ford tech in the shop did one about a year ago and said it was the biggest pain.
@Mebob200111 жыл бұрын
ye from what i understand it can be, but doing it in chassie is, i would pull the engineto replace it myself
@dsdiesel866710 жыл бұрын
Just curious, what all would I need to start working on these on the side (as in any & everything)? I have all main tools as I'm a diesel tech in a Volvo truck shop but, I'm fascinated with all the diesel pick ups, I have an old idi non turbo I'm fixing up at the moment which is like day & night to a power stroke! lol I have the air test fitting (made one in the shop one day working on a f450 with a 6.0, that was a nightmare at first lol), also have the IPR socket (attempted to make one out of a 1/2" drive axle nut socket that was a waste)! Anyways any other tools needed (gauges, specialty tools, etc)? Also, a good scan tool that's bi-directional but not bad on the wallet(checked out the maximus but, it's $3400), saw a program called auto ingenuity that was a purdy good price & was bidirectional, the reviews seem promising, I currently have ScanXL pro with the ford add on but, all I can do is view codes and PID's, which is helpful but, isn't as good as having the ability to command the IPR valve or do injector cut out, etc. Any how, thanks in advance and have a blessed day! P.S. sorry to be so lengthy!
@FordTechMakuloco10 жыл бұрын
Well I would say the block off tools for each head when doing dead head pressure test, the special threaded fuel pressure test adapter. There aren't many special tools for the common repairs on these. I think the most useful is a bi directional scan tool like you say so you can control things like the ipr fuel pumps etc we do most of our diagnosis with the functions on the scan tool so that is the most important tool on these.
@JohnnieCoffman14 күн бұрын
Have a 2004 f350 super Duty got hot want stay running
@paulfiebke3909 Жыл бұрын
Keep up the good work
@jdb193010 жыл бұрын
Where can I get one of those fittings for the icp to air
@FordTechMakuloco10 жыл бұрын
Online sells them OTC 303-765
@weyli100010 жыл бұрын
Hi I have a 04 6.0 no start it has a new oem ipr 2 months ago new after market icp was running good after I replace those parts but now won't start oil pressure gauge goes up when cranking what u think thanks
@FordTechMakuloco10 жыл бұрын
luis lopez Start with the pressure test that tells all. My bet is something has blown through the ipr screen again.
@jamesb13045 жыл бұрын
good evening I have a ford LCF 4.5 L diesel its a 6.0 less two cylinders, it has a Now start, the Ficim is 48 volts Key on brand new ICP hits 1000 Psi or 1.55 volts and the IPR is 35% it will not start still i had a Code for Injector 6 I changed the injector and the Code went away I have No active Codes, any body have any idea? thanks
@andrewstevens92465 жыл бұрын
I tested mine for a small hpo leak... I applied power to the ipr, I done the same test you done and the air sound did not change, there is still air sound coming from the oil fill and vent on the drivers side valve cover, so I pulled the ipr and done a bench test and the ipr worked on the bench test. I’m confused what my problem with my truck is.
@snebrs35404 жыл бұрын
I had the same problem. I used FORScan to close the IPR and did not hear much change if at all. The reason was because I has significant dummy plug and stand pipe leaks. Pull the dummy plugs and check the seals. If damaged replace and try leak test again.
@justinwarren29393 жыл бұрын
Any update on why that happened? Or does op have any thoughts on why this happened to y’all.?
@mf89133 жыл бұрын
Would this cause hesitation or bucking only at highway speeds?
@Jericho_bella5 жыл бұрын
I just purchased a ipr will arrive in a few days preying that’s my crank no start issue
@dustinwag11675 жыл бұрын
Was it?
@Jericho_bella5 жыл бұрын
Dustin Wag no installed brand new one still low icp I have high pressure oil leak buying air test fitting to locate leak
@JBrain-qs1ll10 жыл бұрын
Great video and good knowledge, thank you. I have a question; what scan tool are you using in this video?
@FordTechMakuloco10 жыл бұрын
That is our Dealer scan tool from Ford called the IDS.
@derrickstoermer66326 жыл бұрын
Hey i have a 04 f250 no start but i cant get live data i have power from the obd 2 port but my scanner says no communication
@SixOFord6 жыл бұрын
What's a good affordable scan tool to buy ?
@Kit-qc8lt4 жыл бұрын
Bluetooth adapter and I forget the name of the app believe it starts with a c
@ceddes26517 жыл бұрын
i'm having a crank no start issue with mine, 390PSI max while cranking and IPR at 86%. hooked up air to the ICP and i heard air coming out of both valve covers and the turbo drain tube or hpop cover... it's a 2003 and i just replaced the HPOP, ICP and IPR 100miles ago. Am i screwed?
@MrNicklinux9 жыл бұрын
Hi, thanks for the video ! Could you tell me how I can command IPR to close from VCI? Thank you !
@MrJarochoTx10 жыл бұрын
I HAVE A 04 F350 DIESEL, THE USE DURING THE DAY AND STEP TO THE STORE AND SHUT OFF, THEN I CAN NOT TURN ON, I HAVE TO WAIT 50 MINUTES FOR STARTING AGAIN .. CAN BE A SENSOR? O WHAT IS THE PROBLEM? ... ME AND I HOPE YOU RESPOND
@FordTechMakuloco10 жыл бұрын
Richie Glez You have a high pressure oil leak and will need to find it with this test in the video. Most likely spot is the dummy plugs or a STC fitting that is starting to fail. Find it before it blows and dies on you. I also Have a video on the STC fitting replacement.
@MrJarochoTx10 жыл бұрын
YOU E-MAIL? TO COMMAND CODES THAT CAME OUT OF MY 2004 F350
@FordTechMakuloco10 жыл бұрын
sent to your inbox
@scrappydawg006910 жыл бұрын
looking for advise. 06 6.0 was cranking longer and longer today. It then would not start. my edge cts shows very low icp pressure which i figured. Well i checked low pressure and the housing fills up.. i already have the updated sct fitting and truck has 161,000 miles.. only about 4000 miles on since studs, hpop update, egr delete. truck ran strong just a starting issue now... where should i start?? i dont have a test fitting for air checking.. thanks
@FordTechMakuloco10 жыл бұрын
I would pull the IPR and inspect it as shown in this video- No Start: Ford 6.0L Powerstroke IPR Inspection
@zachcollinson955510 жыл бұрын
Hey what eneded up being the fix on this?
@dennischandler690410 жыл бұрын
Constant air in the hose while doing the air test???
@FordTechMakuloco10 жыл бұрын
Yes
@ryanepperson255610 жыл бұрын
I have a 06 6.0 had dummy plugs replaced a year ago and just replaced the egr and oil cooler, I drove it for three days and a code PO 2290 poped up, injector cnrl press to low my truck runs great,starts and idles perfect. is it my ipr valve?
@FordTechMakuloco10 жыл бұрын
Ryan Epperson Do you have access to a scanner we need to check the icp voltage koeo to make sure it is not biased.
@ryanceppersson10 жыл бұрын
FordTechMakuloco no I have no access to a scanner I have a scanner that just reads codes, should I just replace my icp censor?
@FordTechMakuloco10 жыл бұрын
Have you cleared the code and drove it again to see if it returns? This code will set after the oil cooler was replaced due to long crank time and air in system.
@ryanceppersson10 жыл бұрын
Yes I cleared the code went for like 10 15 miles and it did come back on
@ryanepperson255610 жыл бұрын
25 to 30
@everber116710 жыл бұрын
Hello again.I haven't been able to get my truck running.I remove the valves cover and there are not any dummy plugs or stand pipes.any suggestions thanks in advance
@FordTechMakuloco10 жыл бұрын
Ok so you have just a single log then and no icp sensor in the valve cover. Those early builds are known for pumps failing on them allot. I am not sure if you replied in the past at the moment about diagnostics we already di because youtube comments are down again.
@everber116710 жыл бұрын
I think the icp is on the front of the valve cover passenger side,just like the one you remove on your video .I remove the valve cover and I didn't see any plugs only a plug with a 1/2 inch drive I can crank it for 10 seconds and the oil gauge don't move but if I crank it again for another 10 seconds the gauge muve right away but it doesn't start so you think may be the pump,thanks for your help
@FordTechMakuloco10 жыл бұрын
There are too many variables, only thing you have verified is the low pressure pump is working. You must do the air test it is the only true way to narrow it down. The next thing I would do is remove the ipr and see if the screen is torn/ smashed in. How did this truck fail, going down the road? Is there any codes?
@dennischandler690410 жыл бұрын
FordTechMakuloco I have done the air test and I here in the hose just constant air is that mean the ipr is stuck open??
@FordTechMakuloco10 жыл бұрын
You have to command the ipr closed at 85% or higher.
@theexodussoldier58564 жыл бұрын
Great video. I’m having a no start on hot. My ICP is reading somewhere around 280 psi on no start. I know it a HPO leak. What I’m trying to figure out how do I command the IPR shut with my Forscan lite BAFX WiFi during air test? Can someone please help me?
@theexodussoldier58564 жыл бұрын
Wow no help. Thanks guys👍🏿
@joeydalia25724 жыл бұрын
Make your own pigtail you hook to the battery
@theexodussoldier58564 жыл бұрын
Joey Dalia I bought me a IPR controller. Thanks though
@JoshuaCollins Жыл бұрын
I'm failing to build pressure have extended crank to start like over 30 seconds. Once it's idling desired ICP PSI is 800 but I'm only getting 480 to 500. Clearly there's a leak somewhere. IPR air test reveals no leaks. ICP air test with IPR blocked by a ball valve on the IPR test fitting reveals no leaks until after about 5 minutes when gurgling and air can be heard through a listening device when placed inside of the oil filter housing. I've read that the only time you'll hear air or oil gurgling through the oil filter housing is when you have an internal leak within the hpop. I pulled the h pop and bench tested it only to find zero leaks whatsoever. Anybody have ideas on what could be going on here?
@JoshuaCollins Жыл бұрын
So I cranked up my air compressor to 125 which is the max and bench tested the hpop again. It took a minute or two but now I can put a heater hose to the low pressure intake port on the h pop and hear gurgling. Sometimes it takes a while for the leak to reveal itself. Another tech told me that these systems are designed to run at thousands of psi and when you're only putting 125 into it it may take a while to hear the leak.
@emilioc1458 жыл бұрын
Hello I would really appreciate your help my 05 has a crank start when hot it has updated stand pipes and dummy plugs I did a leak test and hear a really loud leak in the pump cover but a very small hiss in the cover ¿is it normal to hear a slight hiss in the valve covers? BTW I have the ids but have no clue how to command the ipr shut
@rileymosier90933 жыл бұрын
Did you ever figured this out I have same problem
@emilioc1453 жыл бұрын
@@rileymosier9093 yes it was the snap to connect fitting there's a updated part that has a integrated lock nut
@chuckiet93359 жыл бұрын
what scan tool is it that you are using looking to get one that can hook up to my laptop to
@FordTechMakuloco9 жыл бұрын
+rivarunner rivarunner I use the dealer scan tool called the Ford IDS.
@martincamargo25078 жыл бұрын
FordTechMakuloco Hi. how did you turn on the IPR? can I just turn the key on? thank you.
@alexoliva20125 жыл бұрын
Man you are the best. Thanks
@taral.r.72222 жыл бұрын
Ok I have a 2004 f250 super duty 6.0 motor with a no start problem the motor will crank over until the batteries go dead but won't start but if u shoot some ether or starting fluid in the airbox it will long crank over and catch up but as soon as you take your foot off pedal it'll shortly die and won't start again and doesn't throw any check engine codes at all. Every KZbin video points towards a bad icp sensor so I replaced it with a brand new one but still no change I took the fuel filter cap off turned key over at fuel bowl fills up and overflows, drained the fuel that was in it a d replaced with new fuel and still nothing!! Don't have money for the snap-on scan tool, so is there anyone who could possibly give me some tricks or tips on what more I can try or something please...
@JayElement139 жыл бұрын
My friend has a 2006 6.0 it's not cranking wouldn't start after he parked it I see oil pressure on ya oil gauge on tha dash I haven't had a chance 2 check tha oil filter 2 see if it's pumping I will and am his truck check engine light not on
@anieramos55446 жыл бұрын
Liqueo del motor liqueo del motor F 350 Super Duty
@anieramos55446 жыл бұрын
Liqueo del motor de una Ford 350 Super Duty 6.0
@gregorywells57703 жыл бұрын
Wow needed this
@mikehastings774210 жыл бұрын
Hey i am having a problem with my 2006 F350. it has a long cranking time before it fires after sitting for a little while (in the morning, after work, etc.) when it starts it seems to run fine. And if it is running for a while and hot and i shut it off to get fuel or whatever it doesnt crank as long but it almost seems like it is trying to fire and stall at the same time until it is completly done with the starting process, then it idles fine, drives fine ect... not running rough i just dont know how to explain i?t. it almost seems like it is getting too much, or not enough fuel but i dont know (no scan tool).This has been going on for a couple months or so but it has always started and never let me down before. a couple months ago i ran injector cleaner/fuel treatment thru it and it seemed to help for a little while but it started to act up again recently. The other thing is i stopped the other night to get fuel, put 10 gallons in and it wouldnt start after. just like the no start in the video above. i killed the batteries trying to start. i got jumper cables and had some one charge my battery and it started up and ran fine (except for that wanting to fire and stall the same time thing) I have no idea what it could be but i believe it has something to do with fuel. Any advise would excellent as this is my first PSD and im pretty much clueless on these more complicated areas. Thanks for the time and i hope to hear back from you, Mike
@FordTechMakuloco10 жыл бұрын
For this problem you really need a scan tool or the Scan Gauge 2 and monitor ficm powers and icp reading because it can go either way with your concerns. Also cold problem could be 1 or 2 glow plugs that have failed. None of this usually turns on a check engine light. You will at least need to get this scanned at auto zone but for a complete diagnostic you will need a scanner of sorts to check this Pids.
@mikehastings774210 жыл бұрын
could it possibly be the "dummy" plugs also?
@FordTechMakuloco10 жыл бұрын
It definitely copuld as they are a slower leak but will still cause problems you mentioned. It is best to see if it is a Ficm power issue or ICP issue then we can concentrate on one system of the engine that we know is causing problems.
@bradsearle91749 жыл бұрын
Has anyone come across what appears to be a missfire only when coasting on a 2004 6.0L ? Only after the truck has warmed up you take your foot off the gas above 2500rpm and it sounds like the injectors are working erratically. sounds like they are turned on and off every .5 of a second or so. if you turned the key off and on constantly with out the engine running just the injector buzz is the same sound. new FICM engine harneses etc. still the same problem
@BuilderofGuitars7 жыл бұрын
brad searle bruh it's a diesel they're going to make noise
@johnnybarrera5838 жыл бұрын
what can i do i have the p2262 code on my ford 350
@obisstuff68845 жыл бұрын
question, I have an ICP thats above the 5volt range. Should I replace the sensor or is it something else?
@kawasakirider97145 жыл бұрын
Obi's Stuff replace bub
@thomasadam15799 жыл бұрын
where can i get the computer program for the 6.0 that you have? i have a 2005 f250 with the nightmare, i mean 6.0 and i just had 8 injectors glow plugs both valve cover gaskets replaced and did the blue spring upgrade the truck ran for a week and i shut it off one day went to start it right back up and it wouldnt start. i put my scanner and my icp wont build above 243 but i dont know if my sensor is bad hpop has a bad seal or whats going on with it. im beginning to hate this money pit
@FordTechMakuloco9 жыл бұрын
Thomas Adam You can get it it from motorcraftservice.com it is very expensive though.
@thomasadam15799 жыл бұрын
FordTechMakuloco thank you I will look into it. Owning this 6.0 it might be a good investment. This has to be the worst engine ford and international could produce. I'm old school 7.3 for life like everyone else.
@abeltejeda606910 жыл бұрын
What is the name of software you are using FordTechMakuloco?
@FordTechMakuloco10 жыл бұрын
It is the Ford IDS software.
@abeltejeda606910 жыл бұрын
thank you!
@firsttimediesels62893 жыл бұрын
My icp went out, if I unplug it and dry it off on the inside I can usually make it home
@lakefxproductions75286 жыл бұрын
Where can you get that adapter?
@02MUSTANGVERT2 жыл бұрын
Thank you bro
@sylviarod630810 жыл бұрын
what scanner tool are you using?
@FordTechMakuloco10 жыл бұрын
Ford IDS dealer scan tool.
@jamiearias46967 жыл бұрын
I have a Ford 250 6.0 when im driving it, the truck just turns off. Can someone help me see what the problem is?
@jasonadams24655 жыл бұрын
I have a 05 Ford f250 with a 6 old done done all the tests on it and still can't get it to crank with no oil pressure what do I do
@Fdmartinez41910 жыл бұрын
Good video very informative
@briansmobile15 жыл бұрын
WONDER WOMAN!!!! Click to make sense → 9:16
@Runk3lsmcdougal7 жыл бұрын
WOuld my edge Cts pull those codes mr fordtech? @FordTechMakuloco
@matutenoel48338 жыл бұрын
good video amigo
@Hf02052 жыл бұрын
Hello. I have 335 code unable to build pressure. New icp. New ipr. Truck fires up no problem. Idles at 500 rpm or so. Sometimes surges up and down. Oil pressure reading from cluster gauhe is at 40 and sometimes goes up to 80. When I shift into drive. My throttle response is dead. I can rev in neutral only.
@allenk56497 жыл бұрын
Nice, thanks!
@josehernanlopezalvarado57477 жыл бұрын
Hola mi carro es 2007 6.0 caliente no prende
@kayoooh10 жыл бұрын
I bought a new ICP for a 2003 6.0. The pigtail that come with it is not color coded! Is there a sure way to find out which wire goes where? Thanks.
@FordTechMakuloco10 жыл бұрын
You can just go off the old one if it is still there to see which wire goes where, or if it is not there send me your email and I will send the information.
@kayoooh10 жыл бұрын
FordTechMakuloco I am new to this, do I post my email address here or is there a way to find your email address somewhere here?
@FordTechMakuloco10 жыл бұрын
just post it here I will delete right away
@mikemcguire85187 жыл бұрын
Sweet
@lakefxproductions75286 жыл бұрын
Nevermind just saw the last comment
@nickayivor84322 жыл бұрын
KNOWLEDGEABLE FordTechMakuloco Amazing tutorial great video thank you very much helpful video. God bless you and all your family around you FordTechMakuloco From Nick Ayivor from London England UK 🇬🇧
@smokeylol39777 жыл бұрын
Rod bearing knocking that's the problem of low oil pressure right there
@BEEPPIS3 ай бұрын
Insane Clown Posse?
@odinhamann34013 жыл бұрын
I have a 2004 f350 with the 6.0l when I crank it over I can get about 450psi of oil pressure but it's asking for over 1k, after a long crank it will finally start but has no power and won't rev up any and then after a few minutes of running it dies any idea on what I'm looking at or were I should go from here? Thanks for your help.
@Millennial10314 жыл бұрын
What size is the test adapter?
@ricardojaramillojr50714 жыл бұрын
12mx1.50 I used a bolt n 7/16 drill bit n a 1/4 tap for an air fitting