Finding Why Compressor Isn't Starting? Fault Surprised Me!!

  Рет қаралды 24,119

Forever Tech English

Forever Tech English

Күн бұрын

Are you facing the frustrating issue of your mini split AC compressor not starting? Don't worry; we've got you covered! In this video, we dive into the common reasons behind this problem and unveil a surprising fix that will keep your AC running in no time. Join our expert team as we guide you through the step-by-step troubleshooting process. We'll explore potential issues such as faulty wiring, capacitor problems, or a malfunctioning thermostat. We aim to help you identify the root cause and provide an effective solution. But here's the twist - the fix we reveal might surprise you! It's a simple yet often overlooked solution that can save you time, money, and unnecessary repairs. You won't believe how easy it is! Whether you're a DIY enthusiast or a homeowner looking to better understand your Air conditioner system, this video is for you. Our friendly and knowledgeable team will ensure you feel heard and provide concise answers to your questions.
Don't miss out on this valuable troubleshooting guide! Hit that play button, and get your mini split AC compressor back in action. Remember, a cool and comfortable home is just a few steps away! Subscribe to our channel for helpful tips and tricks to keep your HVAC system running smoothly. Together, let's conquer the challenges of AC maintenance and enjoy the comfort we deserve.
******************************************************************************
Products You Might Be Interested in buying and sharing with your friends. Thanks!
Multimeters
NEOTECK Digital Multimeter ➡️ s.click.aliexp...
ANENG Q1 Digital Multimeter ➡️ s.click.aliexp...
Digital Pen Multimeter ➡️s.click.aliexp...
Rechargeable Smart Multimeter ➡️s.click.aliexp...
UNI-T UT181A True RMS Auto Range Multimeter ➡️ s.click.aliexp...
ANENG 616 Large Screen Digital Multimeter ➡️ s.click.aliexp...
TOOLTOP ET8135 True RMS Multimeter ➡️s.click.aliexp...
MASTECH MS8910 Digital Multimeter ➡️ s.click.aliexp...
ZOYI ZT-X Digital Multimeter ➡️ s.click.aliexp...
ANENG Q1 Digital Multimeter 9999 Analog Tester ➡️ s.click.aliexp...
Thermal Camera
UNI-T UTI260B HD 256X192 Thermal Camera ➡️ s.click.aliexp...
TOOLTOP ET692Cl Thermal Imaging Camera ➡️ s.click.aliexp...
Mileseey TR120E Infrared Thermal Imager ➡️ s.click.aliexp...
Fluke TiS55+ Thermal Camera 9HZ ➡️ s.click.aliexp...
Noyafa NF 522 523 Handheld Infrared Thermal ➡️ s.click.aliexp...
TOOLTOP T7 256*192 Android Thermal Imager ➡️ s.click.aliexp...
Soldering Wires
10Pcs 2mm XZZ-2015 Desoldering ➡️ s.click.aliexp...
0.8mm/1.0mm 50g Lead-Free Solder➡️ s.click.aliexp...
0.6/0.8mm 50g/100g Lead Free Solder➡️ s.click.aliexp...
200g 500g Tin Wire Soldering Wire ➡️ s.click.aliexp...
8g 50g Per Roll High Purity Soldering Wire➡️ s.click.aliexp...
250m/roll 30AWG UL1423 Insulation Cable Copper➡️ s.click.aliexp...
Vacuum Pump
18V Lithium Battery Vacuum Pump ➡️ s.click.aliexp...
VEVOR 2.5CFM Refrigerant Vacuum Pump ➡️ s.click.aliexp...
Refrigerant Vacuum Pump ➡️ s.click.aliexp...
VEVOR 1.8-4.8CFM Refrigerant Vacuum Pump➡️ s.click.aliexp...
Mani Fold Gauge
Digital Manifolds Refrigerant Gauge ➡️ s.click.aliexp...
R410A R22 R134a R404A Manifold Gauge ➡️ s.click.aliexp...
Refrigerant pressure gauge ➡️ s.click.aliexp...
500/800PSI Refrigerant Manometer ➡️ s.click.aliexp...
HONGSEN HS-330 Refrigeration Vacuum ➡️ s.click.aliexp...
Air Condition Gauge Manifold ➡️ s.click.aliexp...
MRCARTOOL L202 Air Conditioner ➡️ s.click.aliexp...
Soldering stations
RF4-H2 Automatic Sleep SMD ➡️ s.click.aliexp...
JCD 2 in 1 Soldering Station LCD Digital Display➡️ s.click.aliexp...
GVDA New Soldering Station ➡️s.click.aliexp...
JCD 8586 Soldering Station 2 In 1 Digital➡️ s.click.aliexp...
******************************************************************************
💡 Support Us On Patreon 👉 bit.ly/3vMga6S
💡Subscribe to The Channel 👉 bit.ly/3vNT7s3
Social Links
💡Facebook 👉 / forevertech3
💡Instagram 👉 / forever_tech1
💡Twitter 👉 / forevertech3
#ac #hvac #compressor #airconditioner #compressor #motherboard #repair #fix

Пікірлер: 29
@hamadaHamed-vl6kq
@hamadaHamed-vl6kq Жыл бұрын
فنان فنان فنان يا احلى هندسه
@Jason-wc3fh
@Jason-wc3fh 2 ай бұрын
The compressor is a 3 phase motor. You had two windings with very accurate resistance readings of 3.8 ohms and one winding was out of spec at 4.3 ohms... Isn't that an indication that the compressor winding is no good? That difference also leads to different amperage readings across the legs when running and the compressor will likely heat up with running time. This is likely the reason the terminals melted on the compressor connection.
@trollteam4422
@trollteam4422 Жыл бұрын
Does the orientation of the condenser coils matter? Can they be either vertical or horizontal?
@babaolowo35
@babaolowo35 Жыл бұрын
THANK you
@ErsinGokay
@ErsinGokay Ай бұрын
excellent tech stuff
@Abdulquariosimea-el1rr
@Abdulquariosimea-el1rr Жыл бұрын
Wonderful video. Pls I wish to learn tutorial about the indoor and outdoor motherboard
@Bass.Player
@Bass.Player Жыл бұрын
I have seen this before on central units. I used large gauge replacement wire to serve as a heat sink, no further problems'
@forevertechenglish
@forevertechenglish Жыл бұрын
👌
@Hi-levels
@Hi-levels Ай бұрын
can you change the fuse in inverted AC compressor?
@forevertechenglish
@forevertechenglish Ай бұрын
You mean to say a fuse inside the compressor? I don't get which fuse do you mean?
@Hi-levels
@Hi-levels Ай бұрын
@@forevertechenglish there is no Fuse inside the inverter compressor for ourdoot unit? My aux unit doesnt start at all for the outdoor part. I have no idea
@forevertechenglish
@forevertechenglish Ай бұрын
@Hi-levels There must be a fuse on the circuit board of the outdoor unit. Not on the compressor, check the circuit board
@nanibelloua4962
@nanibelloua4962 2 ай бұрын
How to make analyzer
@garryarrivado5152
@garryarrivado5152 Ай бұрын
@abdalqadr1
@abdalqadr1 2 ай бұрын
❤❤❤❤❤
@ballesteros614
@ballesteros614 11 ай бұрын
I have a unit that is cooling but not blowing out sufficient air and not cooling the apartment, what can be the cause of this?
@forevertechenglish
@forevertechenglish 11 ай бұрын
The coils could be dirty, the dirty coils make the air not to blow properly
@user-cv5qr8fk4i
@user-cv5qr8fk4i 2 ай бұрын
請問有中文字幕嗎?
@forevertechenglish
@forevertechenglish 2 ай бұрын
是的,这个视频添加了中文字幕,你可以看看。如果没有,请告诉我,我会为你添加。
@erichertsens
@erichertsens Жыл бұрын
I have a question, unrelated but might be of interest, lets say i have a string of solar panels wirh a steing voltage of 300V, is there a way to just inject that power just past the bridge rectifier? Food for thought
@forevertechenglish
@forevertechenglish Жыл бұрын
Well, that's something cool to do. I will have to figure out and experiment with it. Then we can get to a conclusion.
@Meerschaut87
@Meerschaut87 2 ай бұрын
Hi Forever Tech English, Thank you for explaining the error on the split unit. if i turn on the AC unit it starts working for about 10 minutes, after that it goes into error P4 and the compressor stops. I have done all test about the compressor wiring and tested the body short, everything is fine (also the compressor works for about 10 minutes, even the pipe starts getting ice on the surface and the indoor unit start to give cold air). I have measured the IPM and it gets +300V on the positive pin and 160V on the U, V and W Pin. Once the unit goes into error mode, the U, V and W Pin only gets a 23V. I have tried measuring the IGBT as you showed in this video: kzbin.info/www/bejne/anrSh2t_YtWWiposi=DmGR5cOUEwL9e8AH - Negative probe on Base (Gate) and Positive on Emitter i get 0.546V - Positive on Gate and negative on Emitter i get 1.083V - Negative on Emitter and positive on Collector i get OL - Positive on Emitter and negative on Collector i get 0.464V - Negative on Gate and positive on Collector i get OL - Positive on Gate and negative on Collector i get 1.372V Is this IGBT broken or is it still oke? what else could give me this error while i don't see anything else wrong or broken? Thanks alot. With friendly greetings
@forevertechenglish
@forevertechenglish 2 ай бұрын
The UVW pins should have 15 volts not 160 volts
@Meerschaut87
@Meerschaut87 2 ай бұрын
@@forevertechenglish That is correct, i hadn't seen the dot between the 6 and 0 Now i measured 22V on every pin.
@user-tq7er5ug3g
@user-tq7er5ug3g 6 ай бұрын
E what problem ?
@forevertechenglish
@forevertechenglish 6 ай бұрын
What is E??
@user-tq7er5ug3g
@user-tq7er5ug3g 6 ай бұрын
E1 error and compressor not work
@Ghedi1965
@Ghedi1965 Жыл бұрын
Thank you
@forevertechenglish
@forevertechenglish Жыл бұрын
Welcome ♥️
Fixing Mini Split AC Dead Motherboard, That Won't Power On!!
11:41
Forever Tech English
Рет қаралды 23 М.
Mini Split AC Circuit Repair, Not Able To Start Compressor
9:54
Forever Tech English
Рет қаралды 28 М.
Fake watermelon by Secret Vlog
00:16
Secret Vlog
Рет қаралды 4,7 МЛН
Gli occhiali da sole non mi hanno coperto! 😎
00:13
Senza Limiti
Рет қаралды 24 МЛН
小丑和白天使的比试。#天使 #小丑 #超人不会飞
00:51
超人不会飞
Рет қаралды 34 МЛН
Matching Picture Challenge with Alfredo Larin's family! 👍
00:37
BigSchool
Рет қаралды 52 МЛН
How to Identify Identical Circuits in Separate AC Brands & Repair
8:29
Forever Tech English
Рет қаралды 7 М.
Diagnosing a Locked Compressor 3D
10:02
HVAC School
Рет қаралды 60 М.
Why Do Capacitors Fail? (It’s not why you think)
36:33
HVAC School
Рет қаралды 546 М.
I Installed R600a Inverter Compressor In OLD Refrigerator!!
12:32
Forever Tech English
Рет қаралды 1 МЛН
{972H} How does an IPM converts DC voltage into three phase
32:10
Haseeb Electronics
Рет қаралды 11 М.
Fixing Mini Split AC Circuit Board With a Most Common Problem
7:18
Forever Tech English
Рет қаралды 59 М.
MINI SPLIT Parts Explained! Understand What They Do!
19:31
AC Service Tech LLC
Рет қаралды 641 М.
Fake watermelon by Secret Vlog
00:16
Secret Vlog
Рет қаралды 4,7 МЛН