G120 VFD TO Compact logix PLC

  Рет қаралды 6,583

PLC Automation Training

PLC Automation Training

Күн бұрын

How to control siemens G120 over ethernet IP using a compact logix controller
Link to AOI and EDS : support.industry.siemens.com/...

Пікірлер: 24
@CrazyCowPie
@CrazyCowPie 2 жыл бұрын
👏👏👏👏👏👏 Straight to the point!!! Most Excellence!!
@adrianramirez2391
@adrianramirez2391 2 жыл бұрын
Thanks so much!!
@akshaythakare9108
@akshaythakare9108 2 ай бұрын
Thanks bro ❤
@ranjankamath2607
@ranjankamath2607 10 ай бұрын
Grate help
@yariprince
@yariprince 2 жыл бұрын
Great
@aleksshutka9481
@aleksshutka9481 2 жыл бұрын
Thanks for the demonstration! Really useful. I don’t understand what pushes people to use Siemens drives and HMIs with AB PLCs. I saw such a machines in different factories and it’s a really weird. You have to pay for both softwares Tia Portal and Studio 5000 and I wouldn’t say that AB PLC are so good that you should stick to them. It’s way more efficient to use only one brand.
@PLCAutomationTraining
@PLCAutomationTraining 2 жыл бұрын
You don't have to use portal to setup the G120 for AB plcs I just own both platforms so I used portal. You make a good point though. I will do another Video showing how to use the Drive to setup its parameters with out portal for this application. My preference for drives is Siemens. In my experience the Siemens drive performs better when match to the same HP or KW motor. When I do jobs that request AB drives I always step up one size on the drive to motor power. This has made my drives last longer. Remember these are just my expirences while in the field.
@PLCAutomationTraining
@PLCAutomationTraining 8 ай бұрын
Plus the basic version is free no license
@camerongreco2146
@camerongreco2146 3 ай бұрын
Can you reply and tell me the tag name for current feedback? I'm about to put a G120X via ethernet into a ControlLogix PLC (L84) sometime tomorrow or early next week for a customer, so I haven't gone through the AOI yet or downloaded it so it may be obvious once I dig into it, but I think I'm going to follow this process and just point the data I/O to my custom control module (AOI) that I call P_VSD, essentially it's a P_VFD plantpax block that I modified to work with any motor type, hard wired, e300, VFD's etc just based on what value you put in it'll swap it's functionality accordingly even in the plantPAX graphics. I'm pretty sure I'd be able to figure it out, but if there's anything I need to know please do because there's a lot more things I'll need from the VFD than what you displayed here. Thanks in advance friend, cheers!
@LukeVader77
@LukeVader77 8 ай бұрын
Thank you very much for the tutorial! I have a question: If I don't have access to Siemens software, am I still able to set up the drive for comms to the rockwell PLC? We're trying to control the drive, but also have it transmit one of its analog input values over to the PLC.
@PLCAutomationTraining
@PLCAutomationTraining 8 ай бұрын
Yes right from the HIM you can do everything,the software is a free download
@LukeVader77
@LukeVader77 8 ай бұрын
@@PLCAutomationTraining Which program are you using, TIA portal? I didn't know it was free 😯
@PLCAutomationTraining
@PLCAutomationTraining 8 ай бұрын
@LukeVader77 the basic version doesn't need a license. here is the link support.industry.siemens.com/cs/document/109807137/sinamics-startdrive-v18?dti=0&lc=en-WW
@PLCAutomationTraining
@PLCAutomationTraining 8 ай бұрын
@LukeVader77 what type of application are you wanting to do? I can help get you started
@felipepimenteldasilva2677
@felipepimenteldasilva2677 8 ай бұрын
Hello, Good tutorial!!!!!! Thanks for all the tips. Can you share the L5k.file? Thanks.
@PLCAutomationTraining
@PLCAutomationTraining 6 ай бұрын
I will look for it or make a newer video and get it for you!
@bovas35
@bovas35 2 жыл бұрын
Good tutorial / thank you It is not very common to use AB PLC and Siemens Drive
@PLCAutomationTraining
@PLCAutomationTraining 8 ай бұрын
Lately it's been going this way, lot more siemens drives being installed, even seeing the plcs being changed. To siemens.
@syedallabakash4295
@syedallabakash4295 2 жыл бұрын
Can you help me to connect ABB drive ACS880 with devicenet communication parameters with Allen Bradley PLC Rslogix 5000
@PLCAutomationTraining
@PLCAutomationTraining 2 жыл бұрын
Abb has a fdna aop
@WeconTechnology
@WeconTechnology Жыл бұрын
Hi, are you stilling making videos now?
@PLCAutomationTraining
@PLCAutomationTraining 6 ай бұрын
I am about to start making more, I was tied up with other stuff but will be back and going again soon!
@edwardbailey6120
@edwardbailey6120 2 жыл бұрын
Love you :-D!! Want more likes? -> P-R-O-M-O-S-M!!!
@PLCAutomationTraining
@PLCAutomationTraining 2 жыл бұрын
I need some promo stuff!!!
Siemens PLC to Drive Communication: Telegrams  in TIA Portal
21:01
Jason Watts AE
Рет қаралды 6 М.
Micrologix 1100 1400 controls a Powerflex 525 over ethernet
36:51
PLC Automation Training
Рет қаралды 64 М.
CHOCKY MILK.. 🤣 #shorts
00:20
Savage Vlogs
Рет қаралды 13 МЛН
Useful gadget for styling hair 🤩💖 #gadgets #hairstyle
00:20
FLIP FLOP Hacks
Рет қаралды 10 МЛН
Ethernet IP Logix PLC for Siemens Drive
12:21
KGBSystems
Рет қаралды 5 М.
Why The Windows Phone Failed
24:08
Apple Explained
Рет қаралды 217 М.
MSG Message from a Micro800 to a Powerflex 525 Drive
10:26
Tim Wilborne
Рет қаралды 11 М.
RSlogix 5000 adding Turck BL20 Over Ethernet
24:55
PLC Automation Training
Рет қаралды 10 М.
Adding a Powerflex 525 to RSlogix 5000 over ethernet
16:56
PLC Automation Training
Рет қаралды 152 М.
Connecting Studio 5000 Logix Emulator to a PLC Program
11:09
Shane Welcher
Рет қаралды 6 М.