GC Troubleshooting-Tailing Peaks

  Рет қаралды 27,539

Restek Corporation

Restek Corporation

6 жыл бұрын

Our chromatograms can tell us a lot, especially if we focus on the details. Trying to diagnose and correct tailing peaks are one area where special attention to the chromatogram can be particularly helpful. We take a look at some of the causes of tailing peaks, which are a very common problem, and how our chromatogram may be giving us clues to their cause.
-----------------------------------------------------------------
Additional Resources
Why do only some of my peaks tail? | www.restek.com...
-----------------------------------------------------------------
Restek Recommended Tools & Parts
Topaz Inlet Liners | www.restek.com...
-----------------------------------------------------------------
Connect with Us
Comment on this video and subscribe to Restek's KZbin channel today at / restekcorp
Website: www.restek.com
Twitter: / restek
Facebook: / restekcorporation
LinkedIn: / restek-corporation

Пікірлер: 11
@SasiKumar-lg1wc
@SasiKumar-lg1wc 2 жыл бұрын
If therotical plate fail mean what is troubleshooting
@sknagulmeera9633
@sknagulmeera9633 4 жыл бұрын
Beautiful tip given by you, thank you
@RestekCorp
@RestekCorp 4 жыл бұрын
Glad you liked it!
@Michal-hardy
@Michal-hardy 5 жыл бұрын
Your dog has cute tailing. Lol
@masroorahmad4009
@masroorahmad4009 4 жыл бұрын
Can you please make a video on fixing heat escaping error . Please!
@ramonverduzco3522
@ramonverduzco3522 2 жыл бұрын
I use Restek Grob mixture often. Dicyclohexylamine is the component most likely to tail or broaden (usually broaden). I haven't figured out why this has been happening. The problem is intermittent and often the dicyclohexylamine peak shape is great, but I don't know what I did different to cause improvement or detriment to this peak shape.
@RestekCorp
@RestekCorp 2 жыл бұрын
Like several other components in the Grob test mix, dicyclohexylamine is testing for inertness. Amines can be particularly sensitive as well and problems with inertness can be the column, the inlet, and at times even the sample prep/handling. Even relatively small changes to any of these could cause changes in response/peak shape of dicyclohexylamine. I think the question to ask here is if the dycyclohexylamine response changes indicate a problem that is impacting your analysis. Does that probe represent compounds that you analyze? Does it predict behavior that you see elsewhere in your analysis?
@jansvoboda9778
@jansvoboda9778 6 жыл бұрын
Thx you help me alot.
@the_hamrat
@the_hamrat 2 жыл бұрын
There is also the case where the peaks will sometimes tail when doing splitless injections
@yohandudognon4108
@yohandudognon4108 Жыл бұрын
What about chemicals with labile hydrogen such as carboxylic acid due to the column ? Is there a way to avoid peak tailing ?
@RestekCorp
@RestekCorp Жыл бұрын
Compounds like carboxylic acids, can be very difficult to get good peak shapes. Depending on the column phase, there may be columns specifically designed to work with acids that can help. Stabilwax-DA columns are an example. Derivitization is also used for some compounds to improve peak shapes - fatty acids are often methylated before being analyzed for this reason. Some analysts also do priming injections - injecting high concentration standards to help occupy active sites before doing their analytical injections. There are many options, but they can all have their pros and cons.
GC Troubleshooting-No Peaks
1:39
Restek Corporation
Рет қаралды 14 М.
Agilent   Ghost Peaks   GC Troubleshooting Series
26:25
24yogeshk
Рет қаралды 48 М.
Викторина от МАМЫ 🆘 | WICSUR #shorts
00:58
Бискас
Рет қаралды 6 МЛН
A teacher captured the cutest moment at the nursery #shorts
00:33
Fabiosa Stories
Рет қаралды 61 МЛН
EVOLUTION OF ICE CREAM 😱 #shorts
00:11
Savage Vlogs
Рет қаралды 14 МЛН
Tailing Peaks - Part 1 - GC Troubleshooting Series
6:18
Agilent Technologies
Рет қаралды 10 М.
Split vs. Splitless Injection
4:41
Restek Corporation
Рет қаралды 121 М.
GC Inlet Maintenance
4:23
Nicole Karn
Рет қаралды 11 М.
GC Tips How to Improve Resolution
5:26
Axion Labs & Training Institute
Рет қаралды 2,9 М.
HPLC Troubleshooting: What is causing baseline noise?
4:14
Axion Labs & Training Institute
Рет қаралды 12 М.
GC Troubleshooting-Split Peaks
2:03
Restek Corporation
Рет қаралды 34 М.
Front-End Maintenance for Your GC Column
5:34
Agilent Technologies
Рет қаралды 3 М.
Separations: Overloading (Fronting) & Tailing
12:52
David Tompkins
Рет қаралды 3,5 М.
Selecting a GC Inlet Liner
2:42
Restek Corporation
Рет қаралды 18 М.
Basic of GC_Part 2 : All About GC Inlets
8:53
YoungIn Chromass Global
Рет қаралды 5 М.
Викторина от МАМЫ 🆘 | WICSUR #shorts
00:58
Бискас
Рет қаралды 6 МЛН