Nice explanation and nice work. One question .... the sanitary hot/cold and the foul water piping ... in which layer are they run ? through the hardcore ? Are the clean and foul pipes separated by some conventional spacing or smtg ?
@markhep9 ай бұрын
Hi mate .they got brought up through the hardcore .the foul water and the clean water were pretty close together think I gave it about 100mm apart . inspector never said anything about it when he came .👍👍
@aussie8114 Жыл бұрын
Was going to ask what the foam board is for but I presume it’s an insulation to keep the floor heating more effective. Never actually seen floor heating before, some people here have it but it’s not common, we don’t get cold enough to warrant it. I presume it’s an effective and economical type of heating. I can see how once the concrete warms up it would radiate heat for an extended time, unlike heating the air which dissipates very quickly.
@markhep Жыл бұрын
Yes mate there's a lot doing it over here now .it's grate in the winter when you got your feet on it feels really strange. especially when you have tiles and it's warm.only problem it there no radiators to dry your clothes on lol👍
@July-A79 ай бұрын
@@markhepset a clothes rack on the tiles and hang your clothes there. They'll dry much better than on radiators . I installed ufh on ground floor by myself and it's so much getter and more economical than radiators .
@markhep9 ай бұрын
@@July-A7 definitely mate 👍👍👍
@Joe-jv5mm Жыл бұрын
Nicely done 👍
@umarhussain8543 Жыл бұрын
Does the visqueen need to be tied into the wall under the dpc before the walls go up? Or can you lay the visqueen after the water and tape it along the walls
@markhep Жыл бұрын
You can definitely lay the visqueen after mate and just put it up wall I nail it higher than the finished wall holds it up a bit 👍
@007issyable5 ай бұрын
Great work guys. Where are you located please?
@AF-ew9zd7 ай бұрын
can I put top membrane over the pipes and not directly over insulation boards?
@markhep7 ай бұрын
Really you want it underneath.dont know if you put it on top it will probably cause the concrete not to warm up a much as it should.you set the pipes in concrete so the pipes are warming the concrete up .I mean you could do it but I don't know weather this would make the heating less efficient.if you know what I mean
@raulfilip988211 ай бұрын
Did you not pour concrete for subfloor?
@markhep11 ай бұрын
It was a massive concrete raft underneath we had to hardcore it to build it up it's about 800mm deep including raft 👍
@JamesKooper Жыл бұрын
👌
@SteveAndAlexBuild Жыл бұрын
Makes me laugh we have to put 2 DPMs in then put a million holes in the top one with all those clips 😂🤣🧱👍🏽
@markhep Жыл бұрын
I know I said to plumber why don't you get them mats they click into he said he likes it this way .my god lol👍👍
@SteveAndAlexBuild Жыл бұрын
@@markhep 🤣🤣🧱👍🏽
@richardjones3112 Жыл бұрын
Exactly what I was thinking.💁
@SteveAndAlexBuild Жыл бұрын
@@richardjones3112 🤦♂️😆🧱👍🏽
@allanparker206818 күн бұрын
That top layer is nothing to do with damp proofing. It's just a slip membrane to protect insulation from the concrete/screed