@danieldebreczeni7021
@danieldebreczeni7021 2 жыл бұрын
Sign me up for the supply plumbing, I love how straight forward and educational in real world scenarios your channel is. Thank you
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@dalehall2606
@dalehall2606 Жыл бұрын
@@gregvancom just make sure that people understand that if you roll up 45 or 22 degree that fixture has to have a vent on same plane as fixture or your breaking vent.
@dreaarm14
@dreaarm14 2 жыл бұрын
Newbie here. I have a degree in biology but love to do home projects! Thank you for making such great lectures ! Never realized how fascinating and technical plumbing is.
@gregvancom
@gregvancom 2 жыл бұрын
You're welcome and keep learning.
@jamesmateush2709
@jamesmateush2709 2 жыл бұрын
Yes! All your insight into water supply would be great!
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@Actrights
@Actrights 2 жыл бұрын
Thank you for the video, It was helpful. I noticed that you have a sanitary tee on its side connecting the shower & sink to the toilet which is not permitted. On the 2nd floor you use a wye for the vent, It looks like the fittings were just used in the wrong place. The 3x3 by 2 wye fitting on the 2nd fl should be on switched with the one on the 1st fl. Then use a bushing and vent 90 on the 2nd fl slightly rotated. With your space constraints it might benefit stepping the 2nd fl tub pipe down to 1 1/2 also using a sanitary tee with a 1 1/2 vent 90 which gives you a tight turn giving you more clearance where you have space constraints. I hope these comments are taken the wrong way I really appreciate your videos they are informative and I learned from this video as I do all you're videos.
@gregvancom
@gregvancom 2 жыл бұрын
I checked it out and it looks like I need to redraw the fitting or I might have grabbed the wrong one. I did make another video with part descriptions that might be more helpful. kzbin.info/www/bejne/j4Sbo4WMnaZ4gdU I also appreciate the way you made your suggestions and let me know if you find any problems with my videos.
@gregvancom
@gregvancom 2 жыл бұрын
Here's the water supply video and thanks to everyone who voted - kzbin.info/www/bejne/gXvdmWWseJqLgJo Here's a video for those interested in the name of fittings. Part 11 - Plumbing Parts And Fitting For Second Story Home Addition - Do It Yourself Tutorial kzbin.info/www/bejne/j4Sbo4WMnaZ4gdU
@dannybriggs127
@dannybriggs127 2 жыл бұрын
Nice to see more on plumbing how to. Thank you.
@gregvancom
@gregvancom 2 жыл бұрын
More to come!
@2099Darius
@2099Darius 2 жыл бұрын
This is incredible! Thank you for another great video! I wilk be doing a 2 story garage addition to my house either mid 2022 or 2023. The information here is really great! If i could subscribe twice i would!
@gregvancom
@gregvancom 2 жыл бұрын
Best of luck and you're welcome.
@mikechaz1643
@mikechaz1643 2 жыл бұрын
Great visual , excellent clear descriptions Evon professional ! Please make rough plumbing vedio
@gregvancom
@gregvancom 2 жыл бұрын
Noted
@gildardomerancia5818
@gildardomerancia5818 11 ай бұрын
EXCELLENT video you explained very well everything Thank you !
@gregvancom
@gregvancom 11 ай бұрын
You are welcome!
@fultonlopez7846
@fultonlopez7846 8 ай бұрын
You are awesome, my daughter and i watch it together
@gregvancom
@gregvancom 8 ай бұрын
Awesome! Thank you!
@CivilianDan
@CivilianDan 2 жыл бұрын
I definitely would like to see the water supply system.
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@asoteico9528
@asoteico9528 11 күн бұрын
Great !!!
@Straycurrent
@Straycurrent 2 жыл бұрын
Thanks for your video. Count me in for the water too.
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@oneness7777
@oneness7777 2 жыл бұрын
This is another great video, I would live to see the supply plumbing.
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@bsyren1
@bsyren1 Жыл бұрын
I would really like to see topics dealing with wet venting. Many times, because of foundation layouts and floor joists, the only solution is to went vent .
@duongnguyen-xm9nf
@duongnguyen-xm9nf 2 жыл бұрын
Build home soon and your video is very informative! More please!?
@gregvancom
@gregvancom 2 жыл бұрын
Thank you! Will do!
@softde
@softde Жыл бұрын
Off course, we want to see it.
@johntapolcai4175
@johntapolcai4175 2 жыл бұрын
Great videos. Would love to see the water line layout.
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@tallpaul8880
@tallpaul8880 2 жыл бұрын
I would be interested to see the water supply system. Thanks for your channel! ✌🏻🇺🇸
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@cagaleched3459
@cagaleched3459 2 жыл бұрын
Water lines would be a nice addition to follow up this video..
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@FriscoPlumbing
@FriscoPlumbing Жыл бұрын
Thank You!
@gregvancom
@gregvancom Жыл бұрын
You're welcome!
@edgarm9020
@edgarm9020 2 жыл бұрын
Great video!
@MrSidhujatt11
@MrSidhujatt11 2 жыл бұрын
good work
@al95hl50
@al95hl50 Жыл бұрын
Thanks
@Samalva93
@Samalva93 2 жыл бұрын
Love the video! Great info thanks
@gregvancom
@gregvancom 2 жыл бұрын
Glad you enjoyed it and thanks for letting us know!
@friendlybill6109
@friendlybill6109 2 жыл бұрын
Please do the water supply video. These videos are very useful. Thanks
@gregvancom
@gregvancom 2 жыл бұрын
Noted!
@rb2512
@rb2512 2 жыл бұрын
Your videos are truly amazing.I would be definitely interested in knowing some of the dimensions for the drains and also for water lines.Ex. Measurements on hight of sink drain or height of where to put stub outs for water lines for a sink etc.
@gregvancom
@gregvancom 2 жыл бұрын
Great suggestion!
@alejandrorivera1782
@alejandrorivera1782 Жыл бұрын
I love your channel.
@gregvancom
@gregvancom Жыл бұрын
Glad you enjoy it!
@jessehernandez7749
@jessehernandez7749 Жыл бұрын
Nice work .. I'd like to see water line set up.
@gregvancom
@gregvancom Жыл бұрын
Noted!
@pedropereira8924
@pedropereira8924 Жыл бұрын
Thanks i really, i like it
@gregvancom
@gregvancom Жыл бұрын
You're welcome 😊
@Affordablebath_remodel
@Affordablebath_remodel 2 жыл бұрын
always well-done videos.
@gregvancom
@gregvancom 2 жыл бұрын
Thanks
@abecarpenter5108
@abecarpenter5108 Жыл бұрын
good job man water riser i would like to see if you can also thank you
@ryankahlor3563
@ryankahlor3563 2 жыл бұрын
Thank you
@gregvancom
@gregvancom 2 жыл бұрын
You're welcome
@joecox9958
@joecox9958 10 ай бұрын
I have a straight down 4" ABS and fell the drop force might be too strong and though a slight turn on middle would be better - comment for you mentioned the part. I now consider my kitchen sewer goes above floor under kitchen cabinet (4" kick foot area), goes bathroom to merge to tub/toilet where are the only sunken area of slab foundation - I mean I don't pour concrete on bath sewer but leave small crawl or no crawlable space for them. Any suggestion?
@donnadelaparra6433
@donnadelaparra6433 2 жыл бұрын
great video
@gregvancom
@gregvancom 2 жыл бұрын
Thanks for the visit
@antman3525
@antman3525 2 жыл бұрын
Logical thinking at the start makes it easier to fix unexpected things, and if there was any, likely to be minor. No one wants to do a rebuild from a missed problem.
@stevenpape8154
@stevenpape8154 Жыл бұрын
Please make another video!
@joecox9958
@joecox9958 10 ай бұрын
thanks! where is you water system video?
@yueqihu
@yueqihu 2 жыл бұрын
Thank you for the video, it is very helpful for home DIYer
@gregvancom
@gregvancom 2 жыл бұрын
You are welcome and thanks for letting us know.
@Ioang40
@Ioang40 Жыл бұрын
What should be done if a house has no air vents anywhere. Will installing air admittance valves on all 3 bathroom sinks and 1 kitchen be ok ?
@leekeen1222
@leekeen1222 10 ай бұрын
can a 3 in long sweep combo wye be used to connect the 2nd floor DWV horizontally to the vertical 3 in vent pipe coming up from the 1st floor DWV plumbing and then continue the vent vertically thru the roof?
@jhonasalazar8995
@jhonasalazar8995 Ай бұрын
Hi so im doing a ADU GARAGE CONVERTION so my father in law installing vent pipe for the toilet cut the wall in 2 pieces t wall its a 2x4 I dont think inspector will aprove that right? Or would he?
@LSaunders4321
@LSaunders4321 11 ай бұрын
Ty horizontally laying down second story
@gregvancom
@gregvancom 11 ай бұрын
Yes.
@chani4974
@chani4974 Жыл бұрын
Can I prolong the drain pipe 4:57 to have two toilets a few feet apart sitting on the same drain pipe? Thanks alot for it all!
@gregvancom
@gregvancom Жыл бұрын
I would check with your local building codes first, but I've seen more than one toilet on 3 or 4 inch horizontal drain lines.
@tallybobba
@tallybobba 2 жыл бұрын
I think the closet wall could be built with 2x6 and the plumbing then ran down the wall rather than through the ceiling and then down the wall. I believe the other bathroom plumbing could still be hooked up. Interior wall could be built to accommodate the plumbing
@gregvancom
@gregvancom 2 жыл бұрын
Go for it.
@christopherhenson400
@christopherhenson400 2 жыл бұрын
Great video! At 4:18, it appears there is a 4"x2" santee on it's side? To pass inspection, would a 4"x2" combo be better served here? Keep up the good work...love the vid!
@gregvancom
@gregvancom 2 жыл бұрын
kzbin.info/www/bejne/j4Sbo4WMnaZ4gdU I made a video with parts list, just in case someone didn't like my parts. Thanks for helping.
@juliancastro6643
@juliancastro6643 Жыл бұрын
its fine if its vertical
@rgentbuilders
@rgentbuilders 2 жыл бұрын
Would love to see the water line layout. Pex?
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@coopermackey4938
@coopermackey4938 2 жыл бұрын
At 5:30 the way you have the toilet plumbed in if someone ran a sewer machine to far and up that wall it’d shatter the toilet. It’s best if possible (and I understand sometimes it’s not) to have it where a sewer machine would travel up a vent stack
@gregvancom
@gregvancom 2 жыл бұрын
Oh yes and if possible, always run the snake in the same direction as the flow of drainage waste. I remember someone sharing a story with me about a drainage snake that came out of a sink and destroyed part of the bathroom.
@coopermackey4938
@coopermackey4938 2 жыл бұрын
@@gregvancom ooof that’s rough lol
@d.brionebey9711
@d.brionebey9711 2 жыл бұрын
The wall behind the tub and shower valves should be bear . If you ever needed to change the valves or housing you would have a sheet rock wall to cut into replace sheet rock or put a vent . This avoid having to cut shower stall material such as marble man-made marble or tile . It’s easy for plumbers to get into the back and reinstall for maintenance any vowels or housing that need to be done they can’t be done in the tub or shower area . Always put shut off valves underneath sinks and kitchen sinks water supplies . This makes plumbing work easier for the plumbers with a lot less labor time .
@ahmedjalal3199
@ahmedjalal3199 2 жыл бұрын
Pretty simple …if I have to reroute the pipe running above the basement ceiling,I have to use 2(45 deg )to achieve 90 deg ???? Thank you for answering
@gregvancom
@gregvancom 2 жыл бұрын
I'm not sure what you're doing, but would suggest contacting your local building department for more information or email me a picture.
@mohamadmoadeli1097
@mohamadmoadeli1097 Жыл бұрын
Thank you for sharing video I,I had noticed a several things needs to fix it .sanitary T on the side ,needs why also for vet went you can not roll that at the 45 degree angle should be on the same horizontal line with just 1/4 grade, another thing on the change in direction of the horizontal develop length can't be more that 2 ×45
@gregvancom
@gregvancom Жыл бұрын
You're welcome and feel free to point out the other 4 problems:) Some one already mentioned the roll in the wet vent, which is the only problem I found after making the video and will be making a follow up video to correct it. As far as the san tee, it's a combo sweep, but I would appreciate any plumbing codes you have on the 2- 45 connecters instead of a long sweep connector.
@montanalivin8248
@montanalivin8248 Жыл бұрын
The current code states that the only clean outs you need are on waste stacks, kitchen sinks, and foot vents for island sinks. I would still install c/o's on washing machines and urinals. Bottom line, a readily accessible c/o will never be a bad thing. The more the better. Do not ever use a santee on its back. Always use a wye or a combination tee wye for a vent fitting.
@gregvancom
@gregvancom Жыл бұрын
The installation of clean outs usually have a few more rules.
@juanlucas5162
@juanlucas5162 Жыл бұрын
Yes you can lay it flat but pick up the toilet first, is called horizontal flat venting only 1 vent for all one complete bathroom, this is for California not to many company’s does it but mine does.
@jonathansantoyo7961
@jonathansantoyo7961 Жыл бұрын
Hi . Can you make a video about a raised foundation house plumbing
@gregvancom
@gregvancom Жыл бұрын
I have some at our website. www.homebuildingandrepairs.com/home_building/index.html look for house building projects.
@rogermoring6027
@rogermoring6027 Жыл бұрын
The tee that does not protrude through the wall is that a test tee?
@gregvancom
@gregvancom Жыл бұрын
If it's a clean out, then they can be used for testing.
@joel6427
@joel6427 4 ай бұрын
When gluing the components together, can you force the pipe to the 1\4" per foot needed?
@gregvancom
@gregvancom 4 ай бұрын
Not really, but I've made it work before.
@joel6427
@joel6427 4 ай бұрын
@@gregvancom How else can the 1/4" per foot be met?
@geroldfirl
@geroldfirl Жыл бұрын
Those are very long horizontal runs on some of the drain lines. Could that be a problem? Did you say there is actually a 1/4 inch per foot downslope on those horizontals?
@gregvancom
@gregvancom Жыл бұрын
Yes, a 1/4 minimum is a good slope for all pipes. You should check with your local building department to figure out if long runs will be allowed. Most of the time they allow up to 75 or 100 feet before requiring a clean out.
@inquizative44
@inquizative44 2 жыл бұрын
I live in an apartment building in which my bathrooms soil stack pipes are being replaced along with the apartment above. The pipes are is being installed below the support beams which will make the ceiling too low, the minimum is 8ft. Running the soil stack pipes below the beams in my bathroom will make my ceiling about 7'5 inches at best with the sheet rock ceiling. I'm no plumber, but why me as a novice can see it (and I warned them) but the plumbers can't? Do they know something I don't? I would love to send you a picture!
@gregvancom
@gregvancom 2 жыл бұрын
You would need to check with local building codes, but most minimum ceiling heights will be around 7 feet.
@inquizative44
@inquizative44 2 жыл бұрын
@@gregvancom Thanks for responding. I did find out, and it's a minimum of 8ft. Just found out by the plumber as I suspected that ceiling will now be about 7'5 inches at best. I warned them, so when the building inspector comes to assess the work completed, I imagine there will be code violations. Oh, and the landlord showed up to take a look. It's on him.
@aaronbaraiya3692
@aaronbaraiya3692 2 жыл бұрын
have you made a decision on making a water supply line video? I would love to see it, thanks :)
@gregvancom
@gregvancom 2 жыл бұрын
Not yet, I still think we need more votes in the comment area.
@aaronbaraiya3692
@aaronbaraiya3692 2 жыл бұрын
@@gregvancom including mine I counted 20 votes
@gregvancom
@gregvancom 2 жыл бұрын
@@aaronbaraiya3692 Thanks for counting and here's you're video - kzbin.info/www/bejne/gXvdmWWseJqLgJo
@aaronbaraiya3692
@aaronbaraiya3692 2 жыл бұрын
@@gregvancom oh wow, great thanks for all your hard work man!
@davidmarsh3750
@davidmarsh3750 2 жыл бұрын
Quick question ... on the second story drains, you run a vent by turning a fitting 45 degrees, going up a few inches, and then running a horizontal pipe in the joist bay to the wall before going vertical to the roof. Is this an exception to the no horizontal vents unless 6 inches above the flood line of the appliance, in this case the rim of the toilet?
@davidmarsh3750
@davidmarsh3750 2 жыл бұрын
For clairification, at the 7:06 mark you state vents cannot be horizontal, you have to angle it up at least 45 degrees, but then shortly after that the vent pipe runs horizontal in the joist bay to the wall before going vertical again. I would like to do this exact thing on a second story bathroom remodel, but not sure if it violates the 6" above flood rim level for horizontal dry vents? Thank you for any help!
@gregvancom
@gregvancom 2 жыл бұрын
First, I would like to thank you for bringing this to my attention. What I should've said is that the vent pipes cannot come off of the drainpipe perfectly flat and will need to have some slope to it. As far as the 6 inches above the rim of a sink goes, this is usually going to be the standard for any situation where you have another plumbing fixture vent connecting into another vent pipe. The vent pipes can be ran horizontal and sloping 1/4 of an inch per foot towards the drainage pipe system.
@davidmarsh3750
@davidmarsh3750 2 жыл бұрын
@@gregvancom Thank you for the reply! I am putting in a bathroom (WC, lav, BT, shower) over my garage. I have 16" deep wooden I-joists so I have plenty of joist space, and I would rather not drop the drains into the garage ceiling space. I am concerned with the local inspector citing IPC 905.4: "Vertical rise of vent. Every dry vent shall rise vertically to a point not less than 6 inches (152 mm) above the flood level rim of the highest trap or trapped fixture being vented." Maybe there are exceptions ("structurally feasible", etc) that I do not know about, but I do not see how the dry vent can be run horizontally in the joist bay and still be compliant with 905.4. I think I can either run a wet vent from the lav or get creative in routing and get vertical dry vents run until above the flood rim. The problem is having a good vertical wall close by, so the drain pipes may have to have longer runs than I would want to accomodate the vents. I am not a licensed plumber so I want to be ready for any questions the inspector may have for me. If you can think of any code work arounds for horizontal dry vents below the flood level, please let me know. Thanks again, and your videos are very helpful!
@rb2512
@rb2512 2 жыл бұрын
We need a water supply video with the dimensions,please.
@gregvancom
@gregvancom 2 жыл бұрын
Got it.
@IdahoSnake-A-Drain
@IdahoSnake-A-Drain 2 жыл бұрын
Let’s press forward
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@kingcountydee
@kingcountydee 2 жыл бұрын
Hello how long can a drain vent run horizontally before going vertically up to the roof? Is there a maximum feet for venting.? Using 2” ABS pipe I’m not a plumber I hope my question make any sense.
@gregvancom
@gregvancom 2 жыл бұрын
This isn't an easy question to answer, because is going to depend upon design and layout of the other plumbing pipes. However, I think it's safe to say that as long as you're not going to making it longer than 5 feet, then you might be safe for practically any situation with a 2 inch pipe. Check with your local building department for clarification on using longer pipes.
@kingcountydee
@kingcountydee 2 жыл бұрын
@@gregvancom So the reason I’m asking is because I want to add a bathroom downstairs and there’s an exiting vent that runs up to the roof. The exiting vent is capped off about 20ft away from where I want to add the bathroom. I was thinking to add a sewer injector pump and connect that to the exiting 3” drain and run 2” ABS to the exiting vent that is 20’ away before it elbows up through my upstairs wall to the roof. I guess I can install a new vent but didn’t really want to make a hole on my torch down roof. Any thoughts on that? Thanks!
@joshuacassino7297
@joshuacassino7297 2 жыл бұрын
How would bathrooms that are on top of each other look? Confused on the toilets
@gregvancom
@gregvancom 2 жыл бұрын
I don't have a video on that but put it on my list of videos to be made.
@joshuacassino7297
@joshuacassino7297 2 жыл бұрын
@@gregvancom could the toilets share same vent?
@TuanNguyen-pp4uo
@TuanNguyen-pp4uo 2 жыл бұрын
Can you do a wet vent for a toilet in basement?
@gregvancom
@gregvancom 2 жыл бұрын
Probably not. Email me a picture of what you're trying to do and I will provide an opinion. You can get our email address at our website.
@cepedacarlos2
@cepedacarlos2 Жыл бұрын
This how ok for Texas plumbing
@Addicted2outdoors
@Addicted2outdoors 2 жыл бұрын
Let’s see the water supply!
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@leekeen1222
@leekeen1222 10 ай бұрын
also i would like to then connect the 1st floor 2 in sink vent to 3 in stack above the 2nd floor horizontal to vertical combo wye described in previous post
@gregvancom
@gregvancom 10 ай бұрын
You can't connect drain to vent. See if this helps kzbin.info/www/bejne/j6nGlZynls2Xf7M
@leekeen1222
@leekeen1222 10 ай бұрын
how do you connect 2nd floor DWV to 1st floor DWV? Do you have to run a separate stack just for venting?@@gregvancom
@ivansu6076
@ivansu6076 2 жыл бұрын
would like to see water supply!
@gregvancom
@gregvancom 2 жыл бұрын
Noted and we're almost there.
@johnpeters9903
@johnpeters9903 9 ай бұрын
At 7:03 that unwashed horizontal vent below the flood rim of the tub is a violation.
@gregvancom
@gregvancom 9 ай бұрын
Can you explain more of provide building code reference numbers.
@tammylynn7397
@tammylynn7397 Жыл бұрын
Please help autoimmune disease brain cancer by the old home. The stink pipe coming out of the main sewer line is only about 2 foot tall and is releasing gas into my basement. Need help to understand how to fix it properly. Please help me ASAP would be very grateful God bless you.
@gregvancom
@gregvancom Жыл бұрын
Cap it, extend it up through the roof or try installing an air admittance valve. I would extend it if possible.
@lawrencedigiovanni9004
@lawrencedigiovanni9004 Жыл бұрын
Are you a Plumbing engineer or master plumber.
@gregvancom
@gregvancom Жыл бұрын
General Contractor who helps master plumbers and plumbing engineers.
@jfh243
@jfh243 7 ай бұрын
Dirty arm for the bathroom vanity upstairs, avoid the line coming out of the floor.
@gregvancom
@gregvancom 7 ай бұрын
I made mistake, just connect wye horizontal to use as wet vent. If this is not what you meant, provide more details.
@marioflores7002
@marioflores7002 2 жыл бұрын
water supply! Thanks!
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@chrisviolette8991
@chrisviolette8991 9 ай бұрын
Why the wet vents?
@cagaleched3459
@cagaleched3459 2 жыл бұрын
Prices went down fir a little while, but now there going back up again
@gregvancom
@gregvancom 2 жыл бұрын
Bummmmmer.
@mattgrizz1153
@mattgrizz1153 2 жыл бұрын
Water supply system. Thank u
@gregvancom
@gregvancom 2 жыл бұрын
Counted.
@randallo3614
@randallo3614 Жыл бұрын
How do rats or snakes get into plumbing?
@gregvancom
@gregvancom Жыл бұрын
Good question. I've seen them come out of toilets and open sewers, so maybe any opening in the plumbing drains would provide easy access.
@jamesarruda5960
@jamesarruda5960 Жыл бұрын
Just as a note. Clean outs are not required on a second story or higher
@gregvancom
@gregvancom Жыл бұрын
Maybe not for all vertical drains, but for horizontal like those in floors.
@MerchantNation
@MerchantNation 2 жыл бұрын
water supply👍👍👍
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@vallanvhaylock6118
@vallanvhaylock6118 Жыл бұрын
Yes please water system
@gregvancom
@gregvancom Жыл бұрын
It should be on our playlist for this series. kzbin.info/www/bejne/gXvdmWWseJqLgJo
@harryohanian
@harryohanian Жыл бұрын
is the toilet drain in the same drain as the sink with one vent considered a wet vent?
@gregvancom
@gregvancom Жыл бұрын
See if this helps kzbin.info/www/bejne/aXjZipt-i9mDqMU
@DrStinkie
@DrStinkie Жыл бұрын
🤣$250,000 PVC coupling!! No kidding
@petermac7095
@petermac7095 2 жыл бұрын
Water supply please
@gregvancom
@gregvancom 2 жыл бұрын
You're vote is counted.
@Jadengome3351
@Jadengome3351 Жыл бұрын
don't connect the tub drain to the toilet stack, that creates a lot of sewer gases from the toilet. better to rough in the lines individually
@ryanbeutler7469
@ryanbeutler7469 Жыл бұрын
I don’t think you can put a santee on its back your better off using a comby fitting
@gregvancom
@gregvancom Жыл бұрын
No it's a combo wye, I made another video naming the fittings and I am planning on updating this video.
@jrc630
@jrc630 2 жыл бұрын
Gas supply!!!!
@gregvancom
@gregvancom 2 жыл бұрын
I will consider it.
@Plasmax-jp6pm
@Plasmax-jp6pm Жыл бұрын
U can't say master bedroom that's racistaaaaa reeeeee
@gregvancom
@gregvancom Жыл бұрын
Sorry:)
@danieldebreczeni7021
@danieldebreczeni7021 2 жыл бұрын
Sign me up for the supply plumbing, I love how straight forward and educational in real world scenarios your channel is. Thank you
@noahbrewster8263
@noahbrewster8263 7 ай бұрын
Thank you!!
@gregvancom
@gregvancom 7 ай бұрын
Welcome!
10 Reasons Why You'd FAIL a Plumbing Inspection! | GOT2LEARN
7:36
How To Plumb a Bathroom (with free plumbing diagrams)
6:18
Hammerpedia
Рет қаралды 5 МЛН
🕊️Valera🕊️
00:34
DO$HIK
Рет қаралды 3,1 МЛН
SHAPALAQ 6 серия / 3 часть #aminkavitaminka #aminak #aminokka #расулшоу
00:59
Аминка Витаминка
Рет қаралды 3,1 МЛН
Inside Out 2: ENVY & DISGUST STOLE JOY's DRINKS!!
00:32
AnythingAlexia
Рет қаралды 17 МЛН
1 сквиш тебе или 2 другому? 😌 #шортс #виола
00:36
Plumbing a bathroom explained in 4 minutes. [You CAN do it!] #diy #plumbing
4:20
Rising Tide Plumbing
Рет қаралды 441 М.
Underground Plumbing
4:40
How to Build Your Own Home
Рет қаралды 94 М.
It's Been a Good Run, Drywall.
20:48
LRN2DIY
Рет қаралды 3,7 МЛН
Wet Venting Video:1 - Wet Venting Basics
5:16
Mathematic Plumber
Рет қаралды 126 М.
Part 1: Plumbing code - waste and venting pipe size
13:15
The Plumbing Academy, Inc.
Рет қаралды 482 М.
🕊️Valera🕊️
00:34
DO$HIK
Рет қаралды 3,1 МЛН