Ground Rod Explained

  Рет қаралды 1,294,929

The Engineering Mindset

The Engineering Mindset

Күн бұрын

What is a ground rod used for? what does it connect to. Find out in this video.
👉 👉👉 FREE design software ➡️ www.altium.com/asp/the-engine...
⚡🛠️ TOOLS YOU NEED 🛠️⚡
**************************************
Get this electronics book ➡️ amzn.to/41cCJPk
Professional Multimeter -➡️ amzn.to/3xu2Vaw
Good multimeter -➡️ amzn.to/3xrbuTd
Professional clamp meter ➡️ amzn.to/4140FnK
Good Clamp meter ➡️ amzn.to/3xqt2is
Outlet tester ➡️- amzn.to/3kavg2l
Energy monitoring plug ➡️ amzn.to/3SkfPl7
Battery tester -➡️ amzn.to/3S3fHWI
Basic electronics kit ➡️ amzn.to/3xuLiqS
MY FAVOURITE GEAR
🎥 My camera - amzn.to/3YCZ7Q9
🎤 My Microphone - amzn.to/3YYXsUC
⌨️ My Keyboard - amzn.to/3lBsl33
🖥️ My monitor - amzn.to/415BGjW
🎧 My headphones - amzn.to/3lN7R7u
Manual transmission ➡️ • How Manual Transmissio...
Alternator ➡️ • How Alternators Work -...
Car battery ➡️ • How A Car Battery Work...
Stepper motor:➡️ • How Stepper Motors Wor...
AC motors ➡️ • How Electric Motors Wo...
DC motors:➡️ • How does an Electric M...
Transistors:➡️ • Transistors Explained ...
Diodes:➡️ • Diodes Explained - The...
Capacitor:➡️ • Capacitors Explained -...
Inductors: ➡️ • Inductors Explained - ...
Voltage regulator➡️ • 5V Regulator design tu...
Series circuits ➡️ • DC Series circuits exp...
Parallel circuits ➡️ • DC parallel circuits e...
👋 SOCIALISE WITH US 👋
*******************************
👉FACEBOOK: / theengineeringmindset
👉TWITTER: / theengmindset
👉INSTAGRAM: / engineeringmindset
👉WEBSITE: Http://TheEngineeringMindset.com
👀 Links - MUST WATCH!! 👀
*******************************
⚡ELECTRICAL ENGINEERING⚡
👉How electricity works: • How ELECTRICITY works ...
👉Three Phase Electricity: • How Three Phase Electr...
👉How Inverters work: • How Inverters Work - W...
👉How TRANSFORMER works: • How does a Transformer...
👉How 3 Phase electricity works: • How Three Phase Electr...
👉How Induction motor works: • How does an Induction ...
👉What is a KWH: • What is a kWh - kilowa...
👉How induction motor works: • How does an Induction ...
❄️ CHILLER ENGINEERING ❄️
👉Chiller Efficiency improvements: • Chiller Efficiency Imp...
👉Chilled water schematics: • Chilled Water Schemati...
👉Chiller crash course: • Essential Chiller Term...
👉Chiller types: • Chiller Types and Appl...
👉Chillers/AHU/RTU: • How Chiller, AHU, RTU ...
👉Water cooled chiller Part1: • Chiller Basics - How t...
👉Water cooled chiller Part2: • Chiller Basics - How t...
👉Water cooled chiller advanced: • How Chiller works - De...
👉Air cooled chiller: • Absorption Chiller, Ho...
👉Absorption Chiller : • Air Cooled Chiller - ...
👉Chiller/Cooling tower/AHU: • How a Chiller, Cooling...
👉Chiller flow rate: • Chiller flow rate meas...
👉Chiller fault troubleshooting: • Chiller faults - troub...
👉Chiller COP calculation: • Chiller Efficiency CAL...
👉Chiller cooling capacity calcs: • CALCULATE Chiller cool...
👉Chiller compressors: • 🔧 Chiller - Compressor...
👉Chiller expansion valve: • Chiller - Expansion Va...
👉Chiller surge: • Chiller - Surge
👉Chiller condenser: • 🔧Chillers - Condensers
👉Chiller evaporator: • 🔧Chiller - Evaporators
👉Chiller compressor centrifugal: • Centrifugal Compressor...
👉Chiller cooling capacity: • Chiller - Cooling Capa...
🌡️ HVAC ENGINEERING 🌡️
👉HVAC Basics: • Fundamentals of HVAC -...
👉Boilers/AHU/FCU: • How a boiler, fan coil...
👉How Heat Pump works: • How A Heat Pump Works ...
👉Heat pumps advanced: • How A Heat Pump Works ...
👉Fan Coil Units: • Fan Coil Unit - FCU HVAC
👉VAV Systems: • Variable Air Volume - ...
👉CAV Systems: • Constant Air Volume - ...
👉VRF Units: • Video
👉Cooling load calculations: • Cooling Load Calculati...
👉Pulley belt calculations: • Pulley Belt CALCULATIO...
👉Pump calculations: • Pump CALCULATIONS, Flo...
👉Fan and motor calculations: • Fan & motor CALCULATIO...
👉HVAC Cooling coils: • HVAC - Cooling coil + ...
👉Cooling towers: • How Cooling Towers Work
⚗️ REFRIGERATION SYSTEMS 🌡️
👉How refrigerants work: • Refrigerants How they ...
👉Thermal expansion valves: • How TXV works - Thermo...
👉Refrigeration design software: • Refrigeration Design S...
👉Design refrigeration system: • How to DESIGN and ANAL...
👉Reversing valve: • Reversing valve - Heat...
👉How A/C units work: • Basic Refrigeration cy...
⚗️ REFRIGERANTS ⚗️
👉Refrierant retrofit guide: • Refrigerant Retrofit G...
👉Refrigerant types, future: • Refrigerant Types, Iss...
👉How refrigerants work: • Refrigerants How they ...
🌊 HYDRONICS 🌊
👉Primary & Secondary system: • HVAC Primary & seconda...
👉Pumps: • Centrifugal Pump How D...
👉Pump calculations: • Pump CALCULATIONS, Flo...

Пікірлер: 460
@EngineeringMindset
@EngineeringMindset 2 жыл бұрын
*These videos take a long time to make* if you would like to buy Paul a coffee to say thanks, link below: ☕ PayPal: www.paypal.me/TheEngineerinMindset Channel membership: kzbin.info/door/k0fGHsCEzGig-rSzkfCjMwjoin Patreon: www.patreon.com/theengineeringmindset
@JoshBasculez
@JoshBasculez 2 жыл бұрын
Do you any solution to my problem. In my place there is frequent high voltage (240v+). Is there anything i can do to maintain the 220V? We are using 220v in my place.
@12345shushi
@12345shushi 2 жыл бұрын
How do you hook up the lightning rod to a subpanel? Does it go to its ground bar? Or its neutral bar?
@isroshashidhar
@isroshashidhar 2 жыл бұрын
What are the effects when no grounding used (both system and protection grounding))?
@EngineeringMindset
@EngineeringMindset Жыл бұрын
Check the new *SUB PANEL EXPLAINED* ➡️ video kzbin.info/www/bejne/hIa2f5RjbK2Ymdk
@EngineeringMindset
@EngineeringMindset Жыл бұрын
Check the new *SUB PANEL EXPLAINED* ➡️ video kzbin.info/www/bejne/hIa2f5RjbK2Ymdk
@ryanstubbs3211
@ryanstubbs3211 2 жыл бұрын
In 2 minutes, you just explained what would take Mike Holt 3 HOURS - and I understood you better. Nice work!
@rickpina5000
@rickpina5000 2 жыл бұрын
You are wrong sir
@danschuster5187
@danschuster5187 2 жыл бұрын
Yeah that talks about his boat n skies then more bla bla
@adfadgaqgv
@adfadgaqgv 2 жыл бұрын
This guy wasn't busy thanking Jesus and having a prayer circle before explaining
@tfun101
@tfun101 2 жыл бұрын
Soooo true lol 🤣...love mike holt though!
@beachstreet5970
@beachstreet5970 2 жыл бұрын
Wow so true. I wanted to like him, because he attempts to explain the NEC, but he just goes on and on without clear explanations and loves to hear himself talk.
@lognum4155
@lognum4155 2 жыл бұрын
Electrical engineer here, I worked with electrical engineer colleagues who had way more experience than me and they actually thought the ground rod is for ground faults, I argued with them about this and they wouldn't even believe me and thought I was crazy lol. FYI, electricity takes ALL paths, not just the least resistance. What I mean about ALL paths is all parallel paths, however the path of least resistance is where most of the current will go to. Grounding and bonding are totally different things
@KM-un8ir
@KM-un8ir 2 жыл бұрын
I am not an electrical engineer, but what you are saying sounds logical to me.
@SoloRenegade
@SoloRenegade 2 жыл бұрын
I work in the super computer industry as a Mechanical Engineer, and having to explain differences in Neutral, Ground, and Bonding to other engineers is something that happens often.
@ashchbkv6965
@ashchbkv6965 2 жыл бұрын
And our lives depend on your engineer colleagues. What's wrong with the education system?
@lanang_solobalapan
@lanang_solobalapan 2 жыл бұрын
Same here. In my university, many people including some of the professors thought that a ground fault could be "magically fixed" just by using a ground rod alone. When i told them that a ground should be connected together with neutral at the main panel in order to trip the MCB, they confidently told me i was wrong and i believe that they must think that i was stupid.
@lognum4155
@lognum4155 2 жыл бұрын
@@ashchbkv6965 Grounding and bonding is not taught in schools let alone MEP engineering. MEP engineering is something you can only learn by actually going into the industry and be trained by a mentor and doing your own research. Theory and knowledge from school helps and will accelerate your learning.
@tihspidtherekciltilc5469
@tihspidtherekciltilc5469 2 жыл бұрын
I was working as an apprentice for a retired electrician that ran a power plant so he knew his craft well when a friend from the local electric company called because they couldn't figure out why people were getting shocked climbing out of the swimming pools on that particular street. These were newly built beach houses that all had swimming pools and all met code with every stage inspected by another retired electrician that knew his craft. The problem was all these houses had two 200 amp panels with constant high loads during the day and the street was fed from one phase. I can't explain the hows and whys as I'm not a licensed electrician but when the power company ran another phase and kept the loads as balanced as they could the problem went away. Apologies for the book.
@arttujarvinen568
@arttujarvinen568 2 жыл бұрын
I think it's important to explain the differences between a TN, TT and IT grounding system in a video like this
@edmondlau511
@edmondlau511 9 ай бұрын
For the minds like mine that aren’t scientific, concepts like this are extremely complicated. Huge shout out of appreciation to those of you who are STEM.
@robertgaines-tulsa
@robertgaines-tulsa 2 жыл бұрын
Electricity will dump most of the current on the path of least resistance. It will still trickle some of the current on the path of high resistance. It's like a voltage divider. Electricity will go wherever it can. It just will put different amounts of current on each path depending on the path's resistance.
@reshpeck
@reshpeck 2 жыл бұрын
That's only of the path of least resistance cannot carry the total voltage produced. Imagine a very narrow water pipe that branches off from a very wide diameter pipe. If the water flowing through the pipe does not exceed its maximum capacity then no significant amount of the water is going to travel by way of the smaller branch
@invitapriore
@invitapriore 2 жыл бұрын
​@@reshpeck Wrong, and dangerously so. Current will flow through every branch in a parallel circuit in inverse proportion to the resistance along that branch, because the voltage at the head of each branch is the same. There's no such thing as a conductor that can't carry a certain voltage -- either its power rating is sufficient to carry the current going through it, or it fails and creates an open circuit.
@mikemazzantini6397
@mikemazzantini6397 2 жыл бұрын
@@reshpeck That's not correct. If you have two ground paths, 1 is 1 Ohm and the other is 50,000 Ohm. The 50,000 will still see some current, just extremely small amounts...as stated above, it's a current divider. Also stating that something cannot carry the total voltage makes no sense. I regularly put 1,000,000+ V on 14 gauge wire.
@kingleonidas4296
@kingleonidas4296 2 жыл бұрын
@@mikemazzantini6397 makes sense. I have dealt with leaking voltage on a spark plug wire but the cylinder still got its voltage for spark.
@altuber99_athlete
@altuber99_athlete 2 жыл бұрын
It is a current divider.
@tedlahm5740
@tedlahm5740 2 жыл бұрын
Paul: As usual clear concise information. You have taught me very much over the three (3) years, INCLUDING this information in previous lessons. Once again, Thank you.
@jessenester1760
@jessenester1760 Жыл бұрын
I second the motion! Nice job on explaining the practical application of a ground rod. True that so many uneducated individuals falsely think it provides and kind of protection against ground faults.Neutral bonding so that electrical currents can get back to the source is the proper means of clearing a fault by allowing the short to trip a breaker.
@antonarasanastasopoulos3482
@antonarasanastasopoulos3482 2 жыл бұрын
I've seen all your videos and all of them are so educational..make a video about grounding a house or a building ...the difference on grounding systems etc..great great job for those videos man. 🔌🔌
@rokiedecentra9656
@rokiedecentra9656 2 жыл бұрын
This always confused me, this was genuinely useful!
@user-eh3qz4zv1o
@user-eh3qz4zv1o 2 жыл бұрын
Great simple understanding, Thank you!
@theforcefor
@theforcefor 2 жыл бұрын
Allways to the point, thank you for your work :)
@linggiman
@linggiman 2 жыл бұрын
you are the best channel for electrical power system graduates
@showeddie
@showeddie 2 жыл бұрын
This channel is pure gold. Thanks!
@bodhiforest401
@bodhiforest401 Жыл бұрын
This channel is brilliant ! thank you for your hard work and help, I am currently binging them all
@shamrockshore6308
@shamrockshore6308 11 ай бұрын
This diagram depicts a TNCS system (Terra Neutral Combined Separate Supply), and the main reason for the ground rod, is to prevent injury when there's a loss of neutral between the meter and supply transformer.
@IbrahimGulraiz
@IbrahimGulraiz 6 ай бұрын
I think your comment should be on the top, since this is point I was missing
@boltonky
@boltonky 2 жыл бұрын
Always clear knowledge and interestingly ground rods just can't be placed anywhere and using more than one changes the resistance but some people already knew that
@joshuadelisle
@joshuadelisle 2 жыл бұрын
What about using a ground rod to take away high frequency noise. For example using one to protect the driving electronics of a CNC plasma table from the HF of the plasma torch?
@Rudda1495
@Rudda1495 2 жыл бұрын
Short and very informative
@benchociej2435
@benchociej2435 2 жыл бұрын
Glad to see such a clear explanation about how fault current isn't significantly handled by ground rods. Too many people misunderstand this. I remember a forum post about a guy installing a hot tub using two conductor ungrounded cable and just driving a local ground rod at the tub... He could use a pointer to this video.
@zhinonghuang6679
@zhinonghuang6679 2 жыл бұрын
People still do that for cooking range. Two 40a wires only with one cooper wire go to ground.
@slazerlombardi
@slazerlombardi 2 жыл бұрын
Thank you deep-heartedly!
@vog51
@vog51 2 жыл бұрын
Nicely explained.
@jsncrso
@jsncrso 2 жыл бұрын
EE here. The main purpose of the grounding rod if to keep the neutral as close to 0 volts as possible in reference to earth. What you say on here is true, but that's not its primary purpose
@abpsd73
@abpsd73 2 жыл бұрын
Is it to keep the neutral at 0 volts, or is it the make the "ground" in the area of utilization the same potential as the neutral conductor? The neutral is a low resistance conductor, whereas the ground is high resistance. Thinking back to my electrical apprenticeship when high voltage installations were being discussed, regarding step potential where you could have a large voltage between footsteps due to earth resistance.
@ke6gwf
@ke6gwf 2 жыл бұрын
@@abpsd73 that's basically what he said. It keeps the Neutral Referenced to the earth, keeping a 0v potential between the Neutral, Ground, the earth, water pipes, etc. If you don't reference the Neutral of a transformer to earth, you will still get 110/220v etc out of it, but any leg could end up being at earth potential, or it could be somewhere in between. I have worked on systems where they forgot to Bond the Transformer neutral, and every night when a shorted out photocell controlled light switched on, Neutral would become 120v to ground, and the hot would be 0v to ground, because the lamp was doing the Bonding... That was a fun one to diagnose! Lol
@abpsd73
@abpsd73 2 жыл бұрын
@@ke6gwf I ran into one of those situations as well. It was a golf course under construction, and there was 120V on the neutral, so the utility company refused to install a remote metering transponder. I started poking around and noticed the 600-120/208 transformer didn't have a bonded neutral. Shut it down, installed the bond, then powered it back up. A breaker for an underground feeder to a remote panel tripped on power up. The cable got mashed somewhere by a piece of equipment. The crew chief was pretty miffed that a panel was out of commission, and didn't handle the explanation very well that the original installing electrician missed something. If the neutral was bonded from the start, the breaker would have tripped when the cable was hit.
@ke6gwf
@ke6gwf 2 жыл бұрын
@@abpsd73 good detective work! Lol My story was an industrial machine room that was fed with 3 phase and then had a floor transformer to provide the 110/220v panel supply, and I discovered it by melting the tip off a screwdriver that bridged a ground strip to a cabinet case one evening, but then when I tried to test it and figure out why the next day, everything appeared normal! It took me a few days until I was in the room at dusk and heard the lighting contactor clunk that I made the connection and then discovered that I could make it flip when I turned the correct breaker off and on. The site rep didn't believe me, didn't think it was possible, so I shut a breaker off, and clipped a jumper wire from the hot terminal directly to the ground buss, and said "watch this!" and flipped the breaker on while he screamed at me to stop! Then after nothing happened, I used the tester to show him how the voltage was flipping, and he finally agreed to get the regular electrician to come in, and I guess he was embarrassed when he was told he hadn't bonded the transformer lol (I was dealing with the industrial automation systems.)
@danielteyehuago1633
@danielteyehuago1633 2 жыл бұрын
Thanks for sharing it with us
@solewalk
@solewalk 2 жыл бұрын
This is a gem.
@IseeSpiders
@IseeSpiders 2 жыл бұрын
This is true for the grounding system pictured (TNCS?), but I think for a TT earthed system it IS the fault path. Restiance is still high which is why residual current/ground fault circuit breakers are needed.
@Mr.Leeroy
@Mr.Leeroy 2 жыл бұрын
Do they even have TN/TT classification in Americas?
@nirodper
@nirodper 2 жыл бұрын
saw an air conditioner flow 8 amps through earth @ 180v (from the 230v supply), that's around 6 ohms impedance (TT). The neutral fuse had blown and the wires had melted, shorting the earth cable to the neutral. The compressor started failing but god knows for how long it ran like that
@AuDap
@AuDap 2 жыл бұрын
Dear author! Thank's a lot for this video! Good luck to you!
@andycrask3531
@andycrask3531 2 жыл бұрын
In the UK some properties use them as ground as the supplier is not obliged to provide one. It's called a TT system
@Mr.Leeroy
@Mr.Leeroy 2 жыл бұрын
There are much higher requirements for resistance of such grounding device though, you have to test it to make sure there will be enough current to trip the breaker as well as to not create voltage divider with middle point higher than some specific value.
@spelunkerd
@spelunkerd 2 жыл бұрын
Good point. I had thought these systems were largely used in remote locations because of higher cost for wire. However I since learned that with RCD/GFCI protection, TT grounding is safe and also less prone to EM interference from other devices on the line. I'm told that TT grounding is common in Japan.
@andycrask3531
@andycrask3531 2 жыл бұрын
@@Mr.Leeroy Yes that is correct I was just keeping simple, In a past life I used to do ECIRs and occasionally had TT installations in rural areas and would pray for acceptable results😂
@maswarservis
@maswarservis 2 жыл бұрын
Very interested information.
@DoubleDeckerAnton
@DoubleDeckerAnton 10 ай бұрын
Interesting and very informative.
@nithishwarm880
@nithishwarm880 2 жыл бұрын
i really enjoy ur short video, nice work :)
@nithishwarm880
@nithishwarm880 2 жыл бұрын
future video idea: tesla coil
@dardilly1
@dardilly1 5 ай бұрын
Well explained.
@VB-yc7cn
@VB-yc7cn 2 жыл бұрын
Finally!! Excellent video my friend
@gus473
@gus473 2 жыл бұрын
👍🏼 Recently installed one for a portable generator to be used for emergency power in an outage. 😎✌🏼
@user-rf4ht8jf2q
@user-rf4ht8jf2q Ай бұрын
The fact that the GFCI picks up the parallel path saves our lives. Even with higher resistance. When your GFCI is tripping be sure to find out why!
@onlineonline3216
@onlineonline3216 2 жыл бұрын
Big fan Thanks for this video
@justwhy7633
@justwhy7633 2 жыл бұрын
This is a kind of video I'm not looking for but i need it.
@fritzmiller9792
@fritzmiller9792 8 ай бұрын
While a lightening strike is absolutely made much more manageable and safer by ground rods ,there is another vital function of ground rods taking place continuously and is arguably equally as important. Grounding maintains an equipotential between structures and power lines as a counter to induced voltage from power lines AND from neutral/center tap drift created by unbalanced loads. This second function of a good inter-system ground is worth explaining too. That was an excellent explanation. I might also add that in tight rural and city areas the multiple paths to ground can be of such low impedance (metal sewer and water systems and several other possibilities) that the returning neutral current will split and be shared between the neutral service conductor and the building/neighborhood total ground paths. I have measured it and it is actually very common for a significant amount of Return/Neutral Current to use an excellent groundpath back to the Utility Source.
@clickortap6401
@clickortap6401 2 жыл бұрын
Well explained..
@witnessmalinga2377
@witnessmalinga2377 2 жыл бұрын
Well explained
@weavercattlecompany
@weavercattlecompany 7 ай бұрын
Having just re-installed a new meter base and added a exterior 200 amp breaker panel to meet current NEC code due to a faulty meter that seemed hell bent on setting the side of my house on fire, they will make you install (2) 5/8 x 8ft ground electrodes at least 6 ft apart and the #4 ground wire is to be installed in one continuous run into the main service panel for low impedance purposes. Don't forget your antioxidant paste for the 4/0 & 2/0 aluminum cables 😉 My house was built from scratch during the late 70's so things have changed a bit code wise since then like separating the neutrals and grounds on their own bus bars. Honestly, I don't really see the point of that since the neutral and grounding (safety neutral) wires are linked to the center-tap of the transformer. It looks a little neater, that's all I can say. I was on generator power for 11 days waiting for the parts to arrive for the install. Wasn't going to let some local electrician price gouge me for $500 - $1,000 to install something that took less than a day. Passed my electrical inspection with ease which cost me $125 which wasn't to bad considering. I also now have a spare meter box and breaker panel in my shop just in case something like this ever happens again so I'm able to strip the guts out of the old box and make the repair in less than an hour 😊 As for the grounding rods, most people don't know that for the most part they are really for lightning and static build-up. Now the exception to this is a fence charger which electrifies fence and when touched finds it's way back to the charger via a grounding rod. The more grounding electrodes you install the more powerful a shock they can deliver which is what keeps livestock from escaping 😜
@paragjh284
@paragjh284 2 жыл бұрын
This explanation shattered the myth I have from my childhood ❤️
@jetroompoc3736
@jetroompoc3736 2 жыл бұрын
Thank you.. And it's good because it's short video.
@ahmedfayez4596
@ahmedfayez4596 2 жыл бұрын
Sir your channel is the best channel ever
@HaInspiration
@HaInspiration Жыл бұрын
👍 & SUBSCRIBED. Very educational, thank you!
@QuaabQueb
@QuaabQueb 2 жыл бұрын
Great simple explanation to wake people up to the fact that "electricity goes ground" is false and incorrect. I encourage everyone to look at Mike Holt's videos to get an in-depth knowledge of grounding. In essence the "ground wire" is there to clear a fault in an over current condition which sets the circuit breaker. The ground rod (or metal water pipe) it self is there to dissipate a high frequency, high energy DC pulse to the earth which is induced on all metallic parts in a building when lightning strike occurs near by.
@briankewber8233
@briankewber8233 2 жыл бұрын
Great
@mrrogers4591
@mrrogers4591 2 жыл бұрын
Ground wire is to protect to from metal boxes, enclosures, cases, etc from being energized and ready to shock/kill someone. The ground wire is for protection of people. GFCI does a similar thing but measures the current path and trips at very low current going through ground or a person.
@wfemp_4730
@wfemp_4730 2 жыл бұрын
Saying "electricity always wants to return to its source" and that "the source of lightning is essentially the Earth" is not only confusing but not totally accurate.
@tedlahm5740
@tedlahm5740 2 жыл бұрын
Sounds accurate to us.
@wfemp_4730
@wfemp_4730 2 жыл бұрын
@@tedlahm5740 I prefer more accurate information, especially from an engineering channel. But you do you.
@altuber99_athlete
@altuber99_athlete 2 жыл бұрын
Correct. I don’t think that’s the reason. It’s because the lightning deposits charged particles on the bare (not insulated) wires of the distribution line when the lightning strikes them. Like charges repel. Also, the Earth is neutrally charged, as in having zero net charge, meaning it doesn't attract nor repel charges on its own. Therefore, the additional charges in the wires repel each other. But since there is a path for the Earth ground through the ground rod, the excess charges can and thus will flow through that path.
@tedlahm5740
@tedlahm5740 2 жыл бұрын
@@jimhabsfan Thank you. And a lightning rod does not catch lightning.
@TheDude-lr6mb
@TheDude-lr6mb 2 жыл бұрын
Totally agreed. As a physics professor I've got triggered by those statements.
@mrugendra
@mrugendra 2 жыл бұрын
Hi. Thank you for the wonderful explainers you have. Do you have an explainer for preventing house fires because of lightening strikes?
@EngineeringMindset
@EngineeringMindset 2 жыл бұрын
Not currently, good idea though
@mrugendra
@mrugendra 2 жыл бұрын
@@EngineeringMindset I have been trying to gather some good information about this topic. But have not been successful so far.
@gus473
@gus473 2 жыл бұрын
@@EngineeringMindset ⚡"Currently" -- 😅👍🏼 Nice one, Paul! 😎✌🏼
@johnkreno2488
@johnkreno2488 2 жыл бұрын
This guy knows his stuff
@asimkhan714
@asimkhan714 2 жыл бұрын
Very good video
@frederickwentz4729
@frederickwentz4729 2 жыл бұрын
So a friend of mine wanted to put lights in some of the palm trees around his property 3 acres ran wiring to the trees so we could use the maximum amount of wire with the least amount purchase twisted all three wires in the Romax together. Then ran a neutral from the light down the palm tree and into the ground with a 6 foot piece of rebar. This worked very well for 30 years with no adverse effects.
@wearsjorge55
@wearsjorge55 2 жыл бұрын
It would certainly work, not sure if electrical meters are done differently elsewhere but without a neutral back to the meter I think your friend wouldn't be paying for the juice to power those lights?
@bamaslamma1003
@bamaslamma1003 10 ай бұрын
The meter is in the hot wires, not the neutral. The neutral passes straight through the meter base to the main panel.
@bigdavexx1
@bigdavexx1 6 ай бұрын
If I'm understanding this right, your friend would have been paying to slightly heat the earth between the rebar and his meter.
@PampostReturning
@PampostReturning 2 жыл бұрын
Thank you.
@malaysiaawesomedy
@malaysiaawesomedy 2 жыл бұрын
Very informative video. Can we grow any plants like flowers, vegetable or tree near the grounding rods?
@Fer-ty3ch
@Fer-ty3ch 2 жыл бұрын
Your have left something very important in your explanation..for all this to work , that ground rod have to be tested. Some guys would think that install a 10’ ground rod is the solution. The fact is that sometimes you need to go 80’ in the ground before your impedance go down to 20 ohms.. is you don’t test the grounding electrode, make sure you have a good insurance.
@karhukivi
@karhukivi 2 жыл бұрын
Agree. It has to be in conductive ground like wet clay and not dry gravel. A ground test with a Megger is advisable.
@geraldarcuri9307
@geraldarcuri9307 2 жыл бұрын
I love these videos, and especially the illustrations. However, I find the illustration of alternating current to be highly distracting, like flashing neon lights. A better approach would be to slow the motion down a bit, and trace the current flow incrementally through the circuit. Perhaps stop-motion occasionally could be used to give the viewer a chance to absorb all the visual and verbal inputs. There's just too much going on simultaneously. In addition, I would suggest that the point at which the ground fault is occurring be emphasized by enlarging that area, or highlighting it, or having an arrow point to it, so that it remains a fixed visual reference against which the various current flows can more easily be observed.
@IceBergGeo
@IceBergGeo 2 жыл бұрын
You can always pause the video. Or rewind, or even play it at half speed, or slower. People will watch it twice if they are interested and want to learn more, as the further you come along, the more the information you've just been exposed to makes sense. Just rewatch it.
@dare-er7sw
@dare-er7sw 2 жыл бұрын
AC doesn't flow just forward in a linear fashion. It alternates back and forth in a wire.
@waytospergtherebro
@waytospergtherebro Жыл бұрын
Jesus Christ shut up.
@WW-hr1hd
@WW-hr1hd 7 ай бұрын
The idea of highlighting the "head" of the "flashing current snake" is a great idea.
@steveperry1344
@steveperry1344 2 жыл бұрын
i was a lineman for the local municipal power company for 40 yrs and we put in a lot of ground rods.
@shockcoach
@shockcoach 2 жыл бұрын
No you don’t, the apprentice does. 😉
@steveperry1344
@steveperry1344 2 жыл бұрын
@@shockcoach yes, if i had one to do it, but lineman had to do it too.
@steveperry1344
@steveperry1344 2 жыл бұрын
@@shockcoach one time we had a big bunch of them stolen from our yard by some copper hounds but they were only 8 ft. long copper clad rods. they took about 100. friggin clowns.
@MarineEngineer1989
@MarineEngineer1989 Жыл бұрын
Would be great if you did some ship specific electrical engineering videos like insulated neutral earthing and distribution systems
@johnsonjohnson1815
@johnsonjohnson1815 2 жыл бұрын
Thanks brother ,
@freekingawwsome
@freekingawwsome 8 ай бұрын
Thank you
@jamess1787
@jamess1787 2 жыл бұрын
I just whacked in a ground rod last week, perfect timing :D
@J4AKSTAR
@J4AKSTAR 2 жыл бұрын
Thanks paul
@rulgempargemilangsago963
@rulgempargemilangsago963 2 жыл бұрын
Good....👍👍👍
@GooogleGoglee
@GooogleGoglee 4 ай бұрын
Never explained better. However this explains also why the European system is safer in case a hot wire connect to the ground, they have a "life switch" set to 30mA that would trigger the breaker and interrupt the power from the source 👍🏻
@alexegus71
@alexegus71 2 жыл бұрын
I'm gonna be studying this groundbreaking video for the next 20 years
@gejokapagador8737
@gejokapagador8737 10 ай бұрын
Thanks for the info.. now i know why everytime that a lightening is happening here in the farm.. the wire that connected to the ground rod is a having a sparks...
@eugenepohjola258
@eugenepohjola258 9 ай бұрын
Howdy. Nice explanation. However. Less is discussed about the purpose of the soil rod. The main purpose is to provide a reference null potential. This null potential is then distributed to plumbing, appliances, concrete rebars and so on via the ground wiring (green). Potential equalizing of touchable parts. Observe that the reference null is not soil null during a ground fault in an appliance. The soil impedance will cause the reference null to rise above the global soil null. But the environment of utilization potential will rise alongside the reference null through bonding. The fault touch voltage between the faulting aplliance and the concrete floor will be smaller. So. The rod reference null is not heavily bonded to the global soil null. The best way to provide reference null is not to use just one rod. Use several rods around the house. This will encircle the environment of utilization for best fault potential equalizaton. Better still. Bury a copper wire around the house and connect both ends to the service panel bonding. Regards.
@kenshiromilesvt.7037
@kenshiromilesvt.7037 2 жыл бұрын
Funny coincidence, I just got this recommended to me the day after I just bought a ground rod with my dad for our new property!!
@SuryanshInstrumental
@SuryanshInstrumental 2 жыл бұрын
😂😂 Awesome Coincidence 😂😂
@IneedMoneyDK
@IneedMoneyDK 2 жыл бұрын
here in Denmark most households use TT system, however places like in the city, were its not possible to burry a rod in the ground due to asphalt they use TN system which is just the transformer stations ground rod ( N ) as i understand
@KpopLabPro
@KpopLabPro 2 жыл бұрын
Would you be able to do a short video explaining what difference is between Volt Free Contact and Dry Contact? A lot of people seem to confuse these two. Thanks
@Cleofizoid
@Cleofizoid 2 жыл бұрын
What do you mean, "seem to confuse these two"? They are synonymous.
@mayamanka77777
@mayamanka77777 2 жыл бұрын
Explain well
@kolejowydolnyslask5684
@kolejowydolnyslask5684 2 жыл бұрын
Thanks.
@MichaelSmith-gl4rf
@MichaelSmith-gl4rf 5 ай бұрын
If the neutral and grounding bar is connected are connected to ground then how does landing a hot wire on the ground rod have only the path of high resistance through the ground rods and not through the grounding conductor through the transformer
@michaelsworkshop9031
@michaelsworkshop9031 2 жыл бұрын
Can you explain more about how the source of lightning is actually the earth?
@SMac-bq8sk
@SMac-bq8sk 2 жыл бұрын
I was pondering over that point as well. Doesn't seem correct, since lightning can also occur between clouds having a difference of electrical potential.
@GoonyMclinux
@GoonyMclinux 7 ай бұрын
​The earth is the positive, I believe he is referring to cloud to ground lightening no cloud to cloud. @@SMac-bq8sk
@TheeSlickShady_Dave_K
@TheeSlickShady_Dave_K 5 ай бұрын
Liked and subbed
@kenbrown2808
@kenbrown2808 2 жыл бұрын
if the grounded conductor between the panel and the transformer fails, the hope is that the grounding electrode will carry enough current to keep the resulting voltage imbalance from being disastrous. it is also used to provide a reference for "zero" volts to ground in the grounded portion of the electrical system. lightning arrester electrode systems are completely SEPARATE from the grounding electrode system. this is also different from an equipotential bonding system which is there to make sure all non current carrying conductive material is at "ground" potential.
@joekesler8014
@joekesler8014 2 жыл бұрын
i was trying to find a polite way of disagreeing with Paul(makers of vid) but you beat me to it. my experience of 45 years teaching upcoming electricians in the field i try to make sure they know the important things that will save lives. one of which is that ground rod (which new NEC code says 2 grounds rods have to be installed) as Ken said is not intended for lightning although it could dissipate some minor strikes, its purpose is to keep a reference to ground. if you lose your neutral an imbalance of voltage can occur(voltage goes down ,current goes up, fries stuff. also i tell them be very carful when disconnecting a ground rod,if it does have a neutral problem could get a big spark when disconnecting.Pauls still a smart guy
@jeffkardosjr.3825
@jeffkardosjr.3825 2 ай бұрын
Separate according to whom?
@kenbrown2808
@kenbrown2808 2 ай бұрын
@@jeffkardosjr.3825 pretty much every code there is.
@user-ki8hx1id9w
@user-ki8hx1id9w Ай бұрын
Actually I would add something to the video was missed which during lightning there is something add to protect against like lightning protection and surge protection. The part will allow the high current to go to the ground during the fault of lightning on the load or transformer sides called surge protection which allow that high current to discharge in the ground. And during the ground fault I would add also something I believe what mean in the video is a high resistance grounding system which most of the time the user install to provide a continuous operation during faults (for some costumer operation needs).
@Ronlawhouston
@Ronlawhouston 2 жыл бұрын
Nice, my copper wires burned through. I knew it had been lightening and I made sure to fix it. Now I understand why.
@slurryz
@slurryz 2 жыл бұрын
Can you do a video on why "electricity always tries to return to it's source" My understanding is that "electrical current will flow from a point of higher electrical potential to a point of lower potential" but I constantly see this trumped by the first rule and would love to know how it works. Thanks.
@girishradhakrishnan2699
@girishradhakrishnan2699 2 жыл бұрын
A battery's high electrical potential is the +ve terminal and low potential is negative terminal.
@kenbrown2808
@kenbrown2808 2 жыл бұрын
there are two types of electrical charge to be considered: in static electricity, you have a "positive" or "negative" charge stored, which seeks to discharge to a point of opposite polarity. this includes lightning and capacitors. in electrical systems that you get work out of, you have an electrical source, whether a battery or a generator. in either case, it has to be a complete circuit to be usable - which means electricity must flow out from the source, through the load, and back to the source; much like a bicycle chain. it has to be a complete loop to propel the bicycle.
@spruce_goose5169
@spruce_goose5169 2 жыл бұрын
The 'source' rule never need 'trump' the potential rule. Potential is relative. A source internally generates a difference of potential--by definition If current did not return to the source (in time) then that implies a charge is building up elsewhere (which can happen), but this then implies that there is a new differential elsewhere that 'wants' to equalize, and it wants to do so with the source. Consider that charge, in the context of power circuits, needs to be constantly replenished--be it by a spinning turbine, a chemical reaction, or photons (photoelectric effect). Where is the charge going to be replenished from? Can it be stolen from some bank? Well if it steels charge, that 'charge hole' will want to be filled. Consider that happening on a contiguous basis and you have a continuous circuit with charge 'returning to source.'
@NikeySunfire
@NikeySunfire 9 ай бұрын
I just realized a lighting strike is just a big arc between the clouds and the earth's soil...mind blown
@entidade1000
@entidade1000 2 жыл бұрын
what about protective earth? Isn't its purpose to serve as a low resistance path for electricity to flow to when a hot wire touches the body of say a refrigerator and tripping the circuit breaker before a person or an animal touches it?
@liberaltears1714
@liberaltears1714 2 жыл бұрын
I dug up a raised flower bed and uncovered my grounding rod. I should sledgehammer it farther down to cover it back up, correct?
@marufboss8230
@marufboss8230 2 жыл бұрын
Thank
@josephrobi6806
@josephrobi6806 Жыл бұрын
Just watching that make me a certified...
@colt10mmsecurity68
@colt10mmsecurity68 2 жыл бұрын
How does a “chassis” ground work, like on the chassis frame of a portable gasoline powered electric generator? Thanks!
@treefarm3288
@treefarm3288 8 ай бұрын
Questions: my system is DIY. Where are you attaching the ground wire and rod to? My area suffers a lot of lightning. A strike a couple of years ago flipped the circuit breaker, but to no avail, and damaged more things than I could afford to replace. These rods are rare in Australia.
@jeffboelter1409
@jeffboelter1409 2 жыл бұрын
So is there an advantage to having 2 grounding rods, from ground out of panel box ? Connected with continuous ground wire.
@ke6gwf
@ke6gwf 2 жыл бұрын
In some soil conditions multiple grounding rods, or complex grounding networks, may be required, in super dry soil, shallow bedrock etc. There are specs for how good the connection is between the earth and the ground rod, and if it doesn't pass something more will have to be done.
@trade1713
@trade1713 2 жыл бұрын
You see in Australia, fault current WILL flow to earth rod. That's because in the main switchboard, Neutral is tied to Earth rod. That link is called multiplied earth neutral (MEN). If neutral in the mains develops high resistance, or is cut, all current goes from phase to earth rod and back to transformer. Very dangerous situation, since all appliances that are earth will have high potential on them.
@larryw95401
@larryw95401 2 жыл бұрын
Actually, electricity follows ALL paths of resistance. Just more current in lower resistance.
@mathiask7959
@mathiask7959 8 ай бұрын
I took down the old barn at the farm, a couple of the pure copper lightning rods had the tips melted
@DavidHotrum52114
@DavidHotrum52114 2 жыл бұрын
Here in the Philippines we have one hot wire and the return is through the ground rod. This makes it cheap for the power company to install electrical service. Is there some way to make this system better at my end? The end user?
@vi683a
@vi683a 2 жыл бұрын
Besides regulations can i use a ground rod on a sub panel and expect some grounding protection on the non grounded Main via the common neutral between the two?
@EngineeringMindset
@EngineeringMindset Жыл бұрын
Check the new *SUB PANEL EXPLAINED* ➡️ video kzbin.info/www/bejne/hIa2f5RjbK2Ymdk
@davidl.howser9707
@davidl.howser9707 Жыл бұрын
Why is the black hot leg wire at the lamp socket not connected / landed on the socket base terminal as is now shown in the video? Why is the socket's base ground wire shown in yellow instead of green per USA NEC Code?
@mickvibes7607
@mickvibes7607 2 жыл бұрын
Sir please do make a video on earthing tutorial...how to make good earthing for domestic or industriak
@bobcocampo
@bobcocampo 2 жыл бұрын
Lightning strikes in the primary or HV will not be discharged in the neutral grounded. Best protection is a surge arresters
@lestermark2279
@lestermark2279 2 жыл бұрын
Ground rod also keeps the neutral point at 0V . Correct me if I am wrong.
@pushagainstthezeitgeist4968
@pushagainstthezeitgeist4968 9 ай бұрын
Not quite. It’s the neutral/earth connection that keeps the neutral point at 0 or earth potential.
@ammoniahuffers
@ammoniahuffers 2 жыл бұрын
"Ground rod is important and protect people!" Indian electrician: are you sure about that?
@TPhype-Discovery
@TPhype-Discovery 2 жыл бұрын
Nice, we probably need a video on LCDs.
@JustHuman87
@JustHuman87 2 жыл бұрын
Could you do a short video explaining Kirchhoff's Law?
@SimplyJoshinYa
@SimplyJoshinYa 2 жыл бұрын
Brief and perfectly explained like always.
Grounding and Bonding an Electrical Panel
13:24
Appalachian DIY
Рет қаралды 301 М.
Where Does Grounded Electricity Actually Go?
19:36
Practical Engineering
Рет қаралды 5 МЛН
Sigma Kid Hair #funny #sigma #comedy
00:33
CRAZY GREAPA
Рет қаралды 34 МЛН
50 YouTubers Fight For $1,000,000
41:27
MrBeast
Рет қаралды 196 МЛН
Cool Items! New Gadgets, Smart Appliances 🌟 By 123 GO! House
00:18
123 GO! HOUSE
Рет қаралды 17 МЛН
Зачем он туда залез?
00:25
Vlad Samokatchik
Рет қаралды 3,3 МЛН
Electrical Grounding Explained | Basic Concepts
6:45
RealPars
Рет қаралды 912 М.
Inductors Explained - The basics how inductors work working principle
10:20
The Engineering Mindset
Рет қаралды 4,2 МЛН
What is Ground? Earth Ground/Earthing
9:27
RimstarOrg
Рет қаралды 3,2 МЛН
Ground Neutral and Hot wires explained - electrical engineering grounding ground fault
11:13
The Easiest Way To Drive Grounding Rods
6:45
Practical Home Projects
Рет қаралды 175 М.
Grounding and bonding: Definitions and details
12:42
Eaton
Рет қаралды 85 М.
How does an Electric Motor work?  (DC Motor)
10:03
Jared Owen
Рет қаралды 17 МЛН
Sub Panels Explained - Why are neutral and ground separated?
16:22
The Engineering Mindset
Рет қаралды 1,2 МЛН
How to make an Earthing at home | Earthing connection for home
8:02
Sigma Kid Hair #funny #sigma #comedy
00:33
CRAZY GREAPA
Рет қаралды 34 МЛН