Hacks Added Freon Every Year Instead of Leak Search - Client Wanted Bosch - We Repaired Instead

  Рет қаралды 18,329

Mikey Pipes - Pipe Doctor Plumbing & Heating & Air

Mikey Pipes - Pipe Doctor Plumbing & Heating & Air

Күн бұрын

Every year another contractor added refrigerant R410A instead of taking time to perform a leak search. In less than 1 hour we identified a leak on the evaporator coil and confirmed the rest of the system was tight. Less than 4 hours later the new coil is installed and system is up and running.
Full Disclosure - being restricted by the scheader cores - we pulled down to 720 microns and it held - passing a decay test.
Please support this channel and Mikey Pipes and consider the following…
Merchandise Requests (United States Only):
Official Pipe Doctor tee-shirts are available in Large & XL - minimum donation of $28 is appreciated
Official Pipe Doctor FlexFit Embroidered Caps - minimum donation of $37 is appreciated
Tee-shirt & Cap donations and I will also include a Pipe Doctor pen
(If you are international - please add a minimum of $40 for shipping/postage)
I ship USPS Priority Mail. Want a shirt or hat? Email me: mike@mikeypipes.com Payment links are below.
Magnets $8.50 each shipped globally and comes with 2 stickers.
I am on Discord & WhatsApp! These extended communities often gets a sneak peak on videos before I make them public on KZbin
Discord: / discord
WhatsApp Group: chat.whatsapp....
Shopping on Amazon? I'll get a small affiliate commission if you save and bookmark this link:
amzn.to/2PjjS4v
THIS DOES NOT COST YOU ANYTHING! Plus I get a small referral commission which equals more #giveaways - So click the link!
Free Sticker Requests:
Do you want a sticker to show your support of this channel? Email your request to me! mike@mikeypipes.com
Name
Address
City, State, Zip
Consider making a donation of $5.00, or ANY amount, to the postage fund! I literally mail out stickers all over the globe. I've sent stickers to HVAC guys in Afghanistan, New Zealand & all over Europe.
Summer-Fall 2021 Version 3.0
Consider donating $7.50 and you will receive Version 3.0 & Version 1.0 - regardless where you live in the world. Postage is included.
PayPal is: office@pipedoc.net
Venmo: @PipeDoctor
CashApp: $mikeypipesny
Want to send a letter, note or gift? Our mailing address is:
Mikey Pipes
C/O Pipe Doctor Plumbing
80 E Hawthorne Ave
Valley Stream, NY 11598

Пікірлер: 108
@gf3559
@gf3559 3 жыл бұрын
As a electrician I appreciate how you are training your worker and not degrading him. He is not a Fckin idiot he is a person who has never done it before and needs to learn!
@josephwhitaker9365
@josephwhitaker9365 3 жыл бұрын
I like how you vacuumed your lines after charging. That's old school knowledge that you're passing on to your helper. Hopefully, he'll do the same once he levels up. Great video as always.
@atiqulny
@atiqulny 3 жыл бұрын
Now, watching your videos is my new hobby.
@lugoismad
@lugoismad 3 жыл бұрын
You have a hell of an apprentice. I wish I'd gone that route instead of to college. Could be making just as much as I do now, but less stress and no debt.
@Rgb414
@Rgb414 3 жыл бұрын
If I was 40 years younger you would be the person who I would like to come work for.
@chesneyquinn2377
@chesneyquinn2377 3 жыл бұрын
Hvac is very stressful.
@atlasfueloilinc.2421
@atlasfueloilinc.2421 3 жыл бұрын
I agree this field is super stressful.
@yomomma9070
@yomomma9070 2 жыл бұрын
@@chesneyquinn2377 it can be but the challenges can also be addictive. And for me it's an insatiable thirst for the knowledge of how these systems work.
@bobboscarato1313
@bobboscarato1313 3 жыл бұрын
Mikey Pipes in the old days before EPA usually if it took a couple of pounds a year; when we did an inspection just added R22. No big deal; now a days you need to isolate sections if system is fairly new. It can be costly as its time-consuming. You do good work. Enjoy your videos!
@throttlebottle5906
@throttlebottle5906 3 жыл бұрын
most people still do that, until the leak gets worse or gas cost is higher that it no longer makes sense to top off.
@petem6291
@petem6291 3 жыл бұрын
Mike very nice diagnosis spending the time to check the integrity of the line set and compressor /condenser just ensures that your diagnosis is 100% correct and prevents and embarrassing call back …
@The-LongRoad-Home
@The-LongRoad-Home 3 жыл бұрын
Self purge gets rid of that Liquid at the end of recovery by the way🤙🏼✌🏼
@joshuabest100
@joshuabest100 3 жыл бұрын
Mike if I may ask a question why did you put the Schrader core on the bigger pipe and squash it instead of using the smaller pipe
@MrGaruga5
@MrGaruga5 3 жыл бұрын
mikey, that purge function the reclaim is to be used to stop all that refrigerant comeing out of the reclaim unit. run it on purge when the system is empty but before you take off the line to the bottle. pushes all the gas from the relciam out, should only have whats left in the line
@Matts_Crafty
@Matts_Crafty 3 жыл бұрын
Daniel Son was ready to zoom lock everything because its so fun to use hahhaaaa! Nice Video...
@dr.comforthvacr8889
@dr.comforthvacr8889 3 жыл бұрын
Amazing job father mikey
@fatcat-hc4pj
@fatcat-hc4pj 3 жыл бұрын
Good evening Mikey Pipes
@jackfrost-fu7hz
@jackfrost-fu7hz 3 жыл бұрын
Nassau County, lived there many years, that repair was probably around $3500.00. I had an evaporator coil replaced in Texas, it was $1500.00 under warranty, no charge for the coil but had to pay for labor and Freon.
@justinh7957
@justinh7957 3 жыл бұрын
I honestly think my boss would fire me if I did this without just pumping down the unit and testing the lineset and evap coil first 😂
@justinh7957
@justinh7957 3 жыл бұрын
@@PipeDoctor maybe if you put the system into a vacuum then yeah atmosphere would get into it but you don't. . Me personally would rather charge it up then leak search with electronic detector and bubbles.
@justinh7957
@justinh7957 3 жыл бұрын
@@boby115 yeah I know I was just joking about the firing 🤣. I watch Mike because he's entertaining and sometimes he shows stuff that I didn't know. I'm always willing to learn and sometimes i comment either jokingly or point out a easier or quicker way to do something. Always willing to dish out and take in
@rickw4160
@rickw4160 3 жыл бұрын
Curious as to why you wouldn't have taken the diagnosis route of using a leak detector around the inside of the coil itself. You can sometimes find the direct source of the leak, and just braze that pinhole. Sure a new evap is probably more reliable however...
@rickw4160
@rickw4160 3 жыл бұрын
Mine too.. it's cheap! Evap side is low pressure so i figured it's way easier just to juice the charge to factory and look for the leak. Find it, pump down, fill with nitro braze the leak, vac and fill up again. I guess it depends on how bad the coil looks inside too .. didn't see of it so maybe your experience tells you best to change it
@henkondemand
@henkondemand 3 жыл бұрын
Bosch: "Why you doing me in like that Mikey."
@chuckquinn8026
@chuckquinn8026 3 жыл бұрын
I thought that was my red RX 350 you were behind, but no I was still here in NJ 😂😂😂. Nice and quick diagnosis Mikey!
@douglaskahane141
@douglaskahane141 3 жыл бұрын
U can remove Schrader’s by removing screws that hold service valves. U then can use core tools
@victormayoral7809
@victormayoral7809 3 жыл бұрын
Yo Mikey. Have you tried any of the fieldpiece sman gauges? I've never seen you use them. They're great in my professional opinion
@williamhughes6051
@williamhughes6051 3 жыл бұрын
Hi Mikey ...Quick question could you recover r22 from an old unit that is being replaced and use the r22 in another unit
@chesneyquinn2377
@chesneyquinn2377 3 жыл бұрын
Yes as long as it was not a burn out.
@MaMa-qh4dy
@MaMa-qh4dy 3 жыл бұрын
Good one! Thank you.
@treborwhite
@treborwhite 3 жыл бұрын
Nice boots Danny 🤟
@tedsmith5058
@tedsmith5058 3 жыл бұрын
Hello from the great state of Michigan 👍👍👍👍👍👍👍
@hvac526
@hvac526 3 жыл бұрын
That's whole different progress than plumbing what's name of that one
@DHVAC
@DHVAC 3 жыл бұрын
Whats the difference between zoom lock and pro press?
@chriswright711
@chriswright711 3 жыл бұрын
ike don't mean to tell you your wrong but. if you read the install manual it will tell you that the 2-3 increaser/reducer shall be install on the vertical not the horizontal of the pipe and it does not say that is ok to install said fitting on the horizontal if its on the intake, So as we say in Canada and as per TSSA code 4.1.3 not as per manufacture.
@REALBanannaman
@REALBanannaman 3 жыл бұрын
one thing about the bosch systems, the ductwork needs to be good because they love to run long times, minimize the heat gain/ loss from the ducts especially if they run in the unconditioned space.
@throttlebottle5906
@throttlebottle5906 3 жыл бұрын
it's called humidity control!
@5822huron
@5822huron 3 жыл бұрын
Elitech... smh.. no!. But that's your sponsor. I get it.
@thefathvacguy6341
@thefathvacguy6341 3 жыл бұрын
Great video. That zoom lock makes quick work...wish i had that available for me lol
@thefathvacguy6341
@thefathvacguy6341 3 жыл бұрын
@@PipeDoctor To pricey for me $$$$$
@hvactechwanttobe1499
@hvactechwanttobe1499 3 жыл бұрын
Me personally i would check the Schrader core and valves for leaks and also when pressure testing check all my braising joints and caps just saying
@jackl9922
@jackl9922 3 жыл бұрын
All nice. Tough to give up the cigs I see. I battle that also. Good luck!
@dylanembry2217
@dylanembry2217 3 жыл бұрын
Mikey you need to ask Marlboro for a sponsorship seen the reflection in van window lol don’t advertise for free great work be safe mike have a good one buddy
@ravenchanney
@ravenchanney 3 жыл бұрын
I enjoy your videos bro it’s just like today I’m not a hvac tech but I kinda felt is was the issue with a water leaking due to something being wrong with the ac at the restaurant I work at evaporator being in the attic and condensate line coming down to a can wash long story I get my plumber to come out and he figured this out quick my guy what a shame for the ac dude that had no clue.
@ravenchanney
@ravenchanney 3 жыл бұрын
Some genius cut the vent on the condensation line
@ravenchanney
@ravenchanney 3 жыл бұрын
Of course keeping in mind the ac dudes didn’t investigate everything and they didn’t install the system but at the end of the day they should’ve looked at and investigated everything.
@ravenchanney
@ravenchanney 3 жыл бұрын
End of story they installed a condensate evaporator pump that didn’t work because the didn’t know vent pipes had been cut end of story it’s unfortunate
@HVACGUY
@HVACGUY 3 жыл бұрын
Saint Mike commands thee
@matthewmcgraw5258
@matthewmcgraw5258 3 жыл бұрын
Hello King Pin MP’s. 😃 👍
@REALBanannaman
@REALBanannaman 3 жыл бұрын
bosch is great hands down
@kizunadragon9
@kizunadragon9 3 жыл бұрын
"St Mike commands thee to fix your system" everyone listens to St Mike
@atlasfueloilinc.2421
@atlasfueloilinc.2421 3 жыл бұрын
Was that diminimis ?
@atlasfueloilinc.2421
@atlasfueloilinc.2421 3 жыл бұрын
Acceptable refrigerant lose ? ( while putting gages on and off ). Just kidding, I was picked on for that in Boces class. Also was with r 22 back then 1995/1996. I most likely spelled it wrong as well Google could not help me I recommend your channel to all apprentices and kids getting into the fields, since this job is more then just plumbing and heating. Great videos , any update on steven (Godzilla ). Keep up the Good content.
@raptorms773
@raptorms773 3 жыл бұрын
In 15 years I have literally found 3 leaks in linesets every other leak has been condenser and evaporator
@eddiew.6485
@eddiew.6485 3 жыл бұрын
Teeeep! 🤲💰🤑. Lunch money. I remember humping my Lunch pail around in the field. They all laughed, until we got stuck in the sh*t end of the 5 boro’s………who’s laughing now, Funny Man!🤣
@northface484
@northface484 3 жыл бұрын
How much is a pack of Marlboro Lights up there...???
@northface484
@northface484 3 жыл бұрын
@@PipeDoctor Damn...I have not bought a pack in years...!!!
@graywolf2694
@graywolf2694 3 жыл бұрын
Recover into the vapor port of the tank, Les liquid will stay in the line.
@lhr1701
@lhr1701 3 жыл бұрын
The pressure will change with the change of temperature from the tank being outside in the truck and now inside in the unit . I can't tell you how many Liquid oxygen and Liquid Nitrogen tanks I get from Mc Kinney that would just blow off in the summer .
@throttlebottle5906
@throttlebottle5906 3 жыл бұрын
ideally, they should never be stored inside a vehicle will they'll get over heated and always shaded. yeah, that's very hard to do in van/box trucks.
@lhr1701
@lhr1701 3 жыл бұрын
@@throttlebottle5906 most people either don’t know or don’t about the fact that acetylene tanks should never be laid on there side.
@throttlebottle5906
@throttlebottle5906 3 жыл бұрын
@@lhr1701 very true, if they realized how unstable a gas it is, they'd never-ever have it inside a vehicle! :)
@altyndom7039
@altyndom7039 3 жыл бұрын
All he wanted was a Bosch, but Mikey Pipes only does for VIP clients the peasants get their leaky units repaired.
@Ryan-re1rs
@Ryan-re1rs 3 жыл бұрын
I think the guy said no no no once Mikey said we would have to rip apart your finished basment. Lol.
@kc9146
@kc9146 3 жыл бұрын
“F$$k Face” 😂
@mactan_layover
@mactan_layover 3 жыл бұрын
Look like a leak detector would have saved time if coil had a warranty and could have used compressor to lock in ref.in outside unit but ya got it.done and a tip
@jaybee1930
@jaybee1930 2 жыл бұрын
@@PipeDoctor if you ain't testing you're guessing good job Mike and Daniel
@chesneyquinn2377
@chesneyquinn2377 3 жыл бұрын
I've went through this isolation process, it's so time consuming. BTW stop smoking,please !
@karlschoen7297
@karlschoen7297 3 жыл бұрын
I can never understand why people thumbs down you your videos are great Also I noticed a pac of boro's on the dash 🧐
@globeflicker9216
@globeflicker9216 3 жыл бұрын
It’s not cigarettes, at least not tobacco ones😏😎 420 CREW🤘
@jeffreywhitlatch1409
@jeffreywhitlatch1409 3 жыл бұрын
I had a guy one time, many years ago, that would not let me look for a leak on his system. He was calling me every week and a half to gas it up. He wouldn't let me go to his Air Handler to check it. He just wanted me to keep coming when he called. He always paid me, but I had to let him go. It was Just nonsense. It was an older man and his mother, they always called late in the day, every week and a half. Gas and go.
@yomomma9070
@yomomma9070 2 жыл бұрын
I've had this before too. Some folks think you have to "fill" the system like you fill your gas tank. And some don't want to pay for leak searches. They can be time consuming whether you do the isolation test Mikey did here or the visual inspection or electronic method. Like he said most of the leaks are in the evap coil that is typically obstructed.
@rruizproductions
@rruizproductions 3 жыл бұрын
Yo Pipes!
@kangaroogod
@kangaroogod 3 жыл бұрын
Don’t forget to foil tape the back of the cabinet if you are removing an old copper coil otherwise you have 2yrs tops before your new coil leaks!
@realsthvac7942
@realsthvac7942 3 жыл бұрын
You still gonna need techs in sc
@jeffgrant6914
@jeffgrant6914 3 жыл бұрын
The evaporator coil
@kojsiusoaliu6772
@kojsiusoaliu6772 3 жыл бұрын
If you don't close the bottle BEFORE the end of your recovery purge, the bottle will refill your recovery unit.
@rustyshakleford5230
@rustyshakleford5230 3 жыл бұрын
Dan is in the very few percent of kids that today will become a man in short order. America is in desperate need of humans like him..
@WaterFaucet24
@WaterFaucet24 3 жыл бұрын
We need a good snack
@timothydemarco3525
@timothydemarco3525 3 жыл бұрын
Mikey can put a link to Daniel’s KZbin channel in the comments please
@stevedentremont3037
@stevedentremont3037 3 жыл бұрын
It’s Daniel leaks a lot
@timothydemarco3525
@timothydemarco3525 3 жыл бұрын
@@stevedentremont3037 I can’t find it
@stevedentremont3037
@stevedentremont3037 3 жыл бұрын
Daniel leaks a lot hvac sorry
@timothydemarco3525
@timothydemarco3525 3 жыл бұрын
Thank you everyone for helping me to find Daniels KZbin channel
@timothydemarco3525
@timothydemarco3525 3 жыл бұрын
@@PipeDoctor yes and your videos help me out Mikey
@The-LongRoad-Home
@The-LongRoad-Home 3 жыл бұрын
Also JB or just better has Schrader core depressors that fita stupid Rheem units
@btcbob11392
@btcbob11392 3 жыл бұрын
I would never tip the owner of the company. I would always tip any helper or employee but never the owner.
@jaybee1930
@jaybee1930 2 жыл бұрын
I got a tip for you Robert don't smoke in bed or bet on horses
@mariofuentes2146
@mariofuentes2146 3 жыл бұрын
Mikey pipes !! Do you smoke cigarettes?
@xlostf8x348
@xlostf8x348 3 жыл бұрын
12:26. That's America's Ass.
@realestateservicessaleshea99
@realestateservicessaleshea99 3 жыл бұрын
Ok,someone has to splain sontings to me???? The lowside was dropping slightly and the highside was climbing slightly with the highside hose off 😳 (I'm just an old school 2 valve analog guy) it was 560# 🥃🥃🍺🍺🍺🍿🏌🏻‍♀️ Stay safe. Retired (werk'n)keyboard super tech. Wear your safety glasses!
@robertlamey7612
@robertlamey7612 3 жыл бұрын
Sometimes customers will NOT fix it properly and demand to just charge it
@robertlamey7612
@robertlamey7612 3 жыл бұрын
@@PipeDoctor yep but unfortunately people don’t want too and say charge it
@robertlamey7612
@robertlamey7612 3 жыл бұрын
It’s funny all the super techs act like they don’t do it. I know better believe me. All companies in my area do it period
@georgekolos5255
@georgekolos5255 3 жыл бұрын
Turn off system. The longer it's off the better. Get your leak detector in the drain like and if it goes off walla! Holy craps the coil is leaking! If it's all aluminum no point in doing anything further tearing apart system wise. 2 choices only we give to such customers... Three actually 1) top off and know sooner or later you'll have to do such again. 2) Replace Evaporator 3) Add a sealant product such AC Easy Seal with UV dye that most likely will fix any small leaks and future small leaks. Which in our years of expierence absolutely does. Guess which option every normal person goes for?
@97Napkins
@97Napkins 3 жыл бұрын
Geeze thats a lot...be funny if did all that and take evap door off and find leak and oil right away. lol
@raptorms773
@raptorms773 3 жыл бұрын
That's cause 85% of the time they are in the evaporator
@rustyshakleford5230
@rustyshakleford5230 3 жыл бұрын
My buddy from highschool Shawn Terry got shot in his chest in Albany NY. His mom has 3 boys. One in prison, one now dead, and one a worker. Not trying to bring anyone down but everyone has gotta keep things in perspective. Keep your family close.
3 жыл бұрын
You can lead a horse to water but you can’t make him drink and i will all ways stand by that and i know that kids should know way more then he knows right now. Sorry bro I call it like I see it. A duck is a duck.
3 жыл бұрын
Nobody is going to go against you and go sub to Daniels KZbin channel. Sorry but that’s how it is.
3 жыл бұрын
@@PipeDoctor I just want to thank you for these beautiful hats you sent me I love them. I wished you would have signed the under the bill tho. But none the less I’m happy thanks buddy your awesome.
@BaconJD420
@BaconJD420 3 жыл бұрын
Like you even more now I heard you say I aint wearing no face mask!
Proper Techniques When Replacing Central AC Equipment Explained
20:08
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 8 М.
How to Properly Diagnose a Failed TXV
31:47
HVAC School
Рет қаралды 595 М.
Life hack 😂 Watermelon magic box! #shorts by Leisi Crazy
00:17
Leisi Crazy
Рет қаралды 80 МЛН
Миллионер | 1 - серия
34:31
Million Show
Рет қаралды 2,9 МЛН
pumpkins #shorts
00:39
Mr DegrEE
Рет қаралды 112 МЛН
This mother's baby is too unreliable.
00:13
FUNNY XIAOTING 666
Рет қаралды 39 МЛН
MP3 CDs: a hybrid "format" that never existed, yet was surprisingly common
34:18
Technology Connections
Рет қаралды 689 М.
How to Properly Service and Perform Annual Maintenance on a Central AC Outdoor Condenser
23:54
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 18 М.
Revolutionary Paint: How to Make Surfaces Stay Cool in the Sun
49:39
Tech Ingredients
Рет қаралды 806 М.
Step by Step Guide: How to Locate and Repair Refrigerant Leak on Heat Pump Outdoor Unit
31:13
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 12 М.
How to Complete a Successful Central AC with Furnace Preventative Maintenance Service Call
14:55
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 11 М.
How To Solder Copper Pipe Like a Pro (Tips & Tricks) | GOT2LEARN
10:46
Leak Search Tips From Bert
17:50
HVAC School
Рет қаралды 71 М.
How to Dynamically Test a Capacitor: Tips and Tricks
24:22
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 5 М.
Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips!
27:56
AC Service Tech LLC
Рет қаралды 1,5 МЛН
Life hack 😂 Watermelon magic box! #shorts by Leisi Crazy
00:17
Leisi Crazy
Рет қаралды 80 МЛН