Hayward OmniLogic | Adding & Programing a Heater to Automation System.

  Рет қаралды 15,487

Elite Swimming Pools TV

Elite Swimming Pools TV

Күн бұрын

Answering a viewers request on how to add and program a newly installed heater to a Hayward OmniLogic Automation system.

Пікірлер: 40
@pjspicer6649
@pjspicer6649 18 күн бұрын
Hi there how do you figure out what relay your heater is on? thank you
@paulpeters4852
@paulpeters4852 Ай бұрын
Can you do a video adding a SMART heater to an existing system
@eliknightlagasse8400
@eliknightlagasse8400 2 жыл бұрын
Question, I have a heat pump that I programmed in the Omni PL but It doesn’t seem to be communicating with the automation. It’s wired into the LV1 one spot inside the panel, but I don’t see anything wired directly into a relay. Does the heater need to be on a relay or is the low volt wired into the LV1 Considered a relay?
@EliteSwimmingPoolsTV
@EliteSwimmingPoolsTV 2 жыл бұрын
Heater should be wired to the Low voltage terminal not any LV
@jefffreeman7903
@jefffreeman7903 2 жыл бұрын
I have the same panel but a pentair mastertemp 400 heater. Heater works fine as does the panel but I can’t control the heater with the omnilogic. I can’t seem to figure it out. Any advice?
@EliteSwimmingPoolsTV
@EliteSwimmingPoolsTV 2 жыл бұрын
Is your MasterTemp Heater connected with the communication wire plugged into the control board of the heater and connected into the Automation panel? This wire is needed and connected in the correct point. It’s a simple insulated 2 wire low voltage wire.
@enriquepagan489
@enriquepagan489 3 жыл бұрын
Hi, I have an Haywaed OmniLogic automatic system and I'm having trouble with the pool light system. After installing the Hayward transformer and connecting them to my Color logic led 1.5 hayward 14 volt ( blue wire), my lights flash like a stroke when I turn them off, every 30 seconds. I download new firmware R03.2.0 2019 version and reprogram my omnidirectional feature in both settings ( activate and deactivate ), without any success. Is it anything else I can do? Is it possible that you do a KZbin video in how to result this problem. Waiting for your response. Enrique
@EliteSwimmingPoolsTV
@EliteSwimmingPoolsTV 3 жыл бұрын
It’s possible your lights may either have a issue themselves or some electrical connection is not proper. I would contact Hayward Technical support or hire a local pool company to check this out for you.
@enriquepagan489
@enriquepagan489 3 жыл бұрын
@@EliteSwimmingPoolsTV Thank you so very much.
@diceman3616
@diceman3616 3 жыл бұрын
Can you add both a gas heater and a heat pump/chiller to the omnilogic?
@EliteSwimmingPoolsTV
@EliteSwimmingPoolsTV 2 жыл бұрын
You probably would have to wire the gas heater to the solar heater connections if unto does not have a dedicated gas heater wire connection point and wire the heat pump to its normal wiring connection point. You may want to confirm this with Hayward Customer Support
@aprilk.gonzalez4074
@aprilk.gonzalez4074 2 жыл бұрын
Hello I wondering if you have a video of how to wire low voltage to heat pump
@EliteSwimmingPoolsTV
@EliteSwimmingPoolsTV 2 жыл бұрын
Not yet
@johnhurney6495
@johnhurney6495 3 жыл бұрын
I appreciate your videos! I installed this same panel last June with the 2-plug receptacle on the side. Is it possible to wire that receptacle to a relay and control it by the app? If so, do you have any info or videos on that? Thank you for all your time and information you put into this. John
@EliteSwimmingPoolsTV
@EliteSwimmingPoolsTV 3 жыл бұрын
I wouldn’t see why you couldn’t wire a 120v receptacle to a relay (given that you have the space for another relay and the main board is capable of handling how ever many total relays the panel has wired). Take the Line side (hot wire) that would be coming into plug re-route to relay Line IN and Line OUT to plug IN. Leave Common wire on common bar. Label that relay with customers label (ex. Receptacle) and when ever you want to utilize that plug then you activate it on the app. All your simply doing is rerouting the wires to go through a relay in order to activate and power that plug when you want power present, not sure why you would want this unless your utilizing these plug for a landscape lighting. If so you can cut the lug part off the lighting transformers power cable and run it into panel direct to relay same you would any other piece of equipment and leave external plug power present all time for when ever you need to plug something in and get instant power, instead of having to go into app and tune on the relay to power plug. Good luck. 👍🏼
@johnhurney6495
@johnhurney6495 3 жыл бұрын
@@EliteSwimmingPoolsTV The plug outlets are being used for rope lighting for the palm trees. The lighting is about 80 feet away and the thought of the convenience of not having to go back around the pool equipment to plug it in to turn it on sounds a lot easier. Unless you have any other suggestions. Thank you!
@EliteSwimmingPoolsTV
@EliteSwimmingPoolsTV 3 жыл бұрын
So being that the trees to be lit is 80 ft away, are you running an extension cord to the tree and then stringing the lights in the tree? Are you suspending the rope light in the air to the tree? How are you running the power to tree? Is your lights a low voltage (12v) and lighting system has a transformer to step down power or high voltage (120v)?
@johnhurney6495
@johnhurney6495 3 жыл бұрын
@@EliteSwimmingPoolsTV They plug right into the receptacle that is installed on the side of the Omni Logic panel.
@EliteSwimmingPoolsTV
@EliteSwimmingPoolsTV 3 жыл бұрын
If this was my house, i would wire a circuit to an open relay inside the panel & label this Landscape lighting. I would dig a trench from the panel to the tree(s) I am wanting to light, run electrical conduit underground feed the 120v circuit line through it and install a electrical weather proof junction box at the base of the tree(s) with a receptacle. That way I can also put a bullet style light shining on the tree and have the rope light up in the tree. Having the receptacle at the tree also gives you power out in the yard for other projects or decoration for parties / Christmas blow ups or any other things you may need out there. With this wired to the panel on the relay you can operate that circuit via mobile phone. This is how I would do it. Good luck. 👍🏼🍀
@ulyssesboulware8239
@ulyssesboulware8239 2 жыл бұрын
I just set up my first OmniLogic. I have the heater wired up through the breaker. Can I bypass the relay and wire it to the low voltage heater output. That should be the form of communication used right?
@EliteSwimmingPoolsTV
@EliteSwimmingPoolsTV 2 жыл бұрын
Heater should be wired to heater relay.
@cydneyschwarzlose1954
@cydneyschwarzlose1954 Жыл бұрын
I have Hayward OmniLogic with a heater/chiller, but can only control the heater and cannot figure out how to switch to activate the chiller - It's over 100 degrees F in Texas and my pool is getting up to 94 degrees F, so I really need to get the chiller set and running. Please help!
@mereandchrisroth5122
@mereandchrisroth5122 Жыл бұрын
FWIW< I have the same issue also in Texas. I have the HP50951T heater, but there is a newer HP50952T heater that has extra wiring to support both the heating and chilling. I have not had good luck with Hayward support, but I did finally get a local company to agree to come look at it. HE commented that I needed to add one more wire, but I think it gets wired to a COM bus instead of the LV heater controls, but I'd be guessing so hoping they can help me.
@EliteSwimmingPoolsTV
@EliteSwimmingPoolsTV Жыл бұрын
Your issue is a programming problem either coming from when the heater was initially programmed to the automation system. First try to go through the program and delete that you have a heater and save it. Then go back in through the program and add a new heater and check if I ask you if the heater has the chill option. I don’t recall if the OmniLogic has the specific program setting. Also, make sure that you’re heater itself has the chill option enabled. I’ve seen on some Hayward heater units that have the chill option, they have to be enabled. Most of the time the heaters from factory come set in heat only mode. you could also always call Hayward technical support and they surely will assist you with your specific situation thanks for watching a commenting.
@coledewiele5171
@coledewiele5171 3 ай бұрын
Open the panel???
@jcdpoolservices1255
@jcdpoolservices1255 Ай бұрын
You might be more careful with MSP # on the panel!!
@rubenjoseph1
@rubenjoseph1 Жыл бұрын
how to add HL chem (sense and depeense) to onmliPL?
@EliteSwimmingPoolsTV
@EliteSwimmingPoolsTV Жыл бұрын
Not sure I would have to research it to know
@theronerd
@theronerd 2 жыл бұрын
Thanks for not showing how you wire the control wire to the board
@EliteSwimmingPoolsTV
@EliteSwimmingPoolsTV 2 жыл бұрын
Bro what do you think this is??? Hire someone and pay.
@Matts_Crafty
@Matts_Crafty Жыл бұрын
@@EliteSwimmingPoolsTV 😂
@cjadventures8840
@cjadventures8840 Жыл бұрын
@@EliteSwimmingPoolsTVlmao
@thomashoang1
@thomashoang1 Жыл бұрын
I have heater but its disabled. How can i enable it?
@EliteSwimmingPoolsTV
@EliteSwimmingPoolsTV Жыл бұрын
Go thru the program
@sarajennen5119
@sarajennen5119 11 ай бұрын
What if it isn’t wired up?
@mark33545
@mark33545 2 жыл бұрын
i wired my gas heater to my omni and it's in remote mode and you can see it turn on and off based on the omni setting, but it never changes the temp up and down. so even though the omni turns it on, it always says 79F for the set point (the last temp set before changing to remote mode).
@EliteSwimmingPoolsTV
@EliteSwimmingPoolsTV 2 жыл бұрын
Is your gas heater programmed and switched to t-Stat remote mode? the heater settings must be switched to this mode. This mode indicates the heater will be controlled by automation controller. Also in your Omni you have to make sure it’s wired to the correct relay and that it’s programmed to that relay. Also you have to make sure that when make these changes in the Omni that you are properly saving it (there is a specific way to save these settings in the Omni). On the heater, try this… go into the settings and disable the remote mode (put it back to operate by its own controller) once this is done, go into the temp settings and raise it all the way up to 104^. Then go back into settings and change back to T-Stat remote mode. Let me know if this works.
@mark33545
@mark33545 2 жыл бұрын
@@EliteSwimmingPoolsTV My gas heater is a rheem (raypak) and all it says on it is to hold the 2 temp buttons for 5 seconds until it goes into remote mode, which is what I did. I have the omni hub, so there is only 1 place to connect a 2 wire heater remote control wire. I tried swapping the two wires and it does the same thing. Although, I realize now as I re-read your reply, the 2 wire is just a simple on/off? No wonder then it's not changing the temp. So basically the heater needs to be at max temp so that when that wire triggers it to turn on, it's hot enough to run. I think I get it now. I will change to 87F (since i never want it to get above that if something goes wrong) and then turn remote mode back on. Thanks much!!!
@mark33545
@mark33545 2 жыл бұрын
@@EliteSwimmingPoolsTV it worked, thanks man.
How to program Omni PL - Omni logic
25:01
Tyler&Patrick
Рет қаралды 10 М.
Pool Heater Install
11:03
ComfortPlus Heating and Cooling
Рет қаралды 66 М.
АЗАРТНИК 4 |СЕЗОН 1 Серия
40:47
Inter Production
Рет қаралды 1,4 МЛН
Whoa
01:00
Justin Flom
Рет қаралды 60 МЛН
Programing Hayward Omni Logic
9:41
John The Pool Expert
Рет қаралды 23 М.
Contractors Hate Me For Showing You This!
24:20
HAXMAN
Рет қаралды 1,6 МЛН
NEVER install these programs on your PC... EVER!!!
19:26
JayzTwoCents
Рет қаралды 3,4 МЛН
Part #1 - Hayward OmniLogic - Understanding Pool Mode. Please Subscribe.
7:50
True Light Pools, LLC
Рет қаралды 43 М.
Get More Heat From Your Radiators ~ System Balance
16:36
Skill Builder
Рет қаралды 947 М.
Hayward  Programming OMNI Automation
1:01:35
Hayward Pool Products- Latin America & Caribbean
Рет қаралды 19 М.
A Look Inside Apple's $130 USB-C Cable
21:52
Adam Savage’s Tested
Рет қаралды 3,4 МЛН
How to Use Your Pool Heater, Put it into Spa Mode & Helpful Tips (Jandy JXi shown)
7:33
Swimming Pool Tips, Reviews & How To - SPL
Рет қаралды 188 М.
АЗАРТНИК 4 |СЕЗОН 1 Серия
40:47
Inter Production
Рет қаралды 1,4 МЛН