High-Voltage Power Line | How To Locate A 750 High Voltage Power

  Рет қаралды 494

811 Chicago Utility Locating

811 Chicago Utility Locating

Күн бұрын

Пікірлер: 14
@jswann70
@jswann70 8 ай бұрын
When hooking up to the u guard will you also be able to locate to a person’s house or business instead of hooking up to the actual meter at the house?
@811chicago5
@811chicago5 8 ай бұрын
Anytime you're dealing with power, especially with secondaries, you always need to go to the endpoint and bring it back to whatever is feeding it. For example, if you have a secondary feeding the house from the pole, you need to go to the raceway (meter set) at the house and bring it back to the pole. If you have a secondary pedestal, you will need to direct connect to the secondary pedestal and bring it back to whatever is feeding that pedestal. Power works in a weird way, but anytime you deal with secondaries, you always want to bring it back to the main source. You never want to start from the main source and bring it out; that's the wrong way of locating power.
@picobyte
@picobyte 10 ай бұрын
Here in the netherlands, all 50kV and lower got digged in underground. For now we call that the medium/mid-voltage power grid. But i don't complain with most of half a kV wired directly in to my home at tree phase 400V AC. Toptop that's serious tension.
@811chicago5
@811chicago5 10 ай бұрын
These Transmissions are standard transmission lines that go from switchgear to switchgear before they become distribution lines to feed businesses and homes. 750,000 volts.
@lucasjack1531
@lucasjack1531 7 ай бұрын
I wanna say that is the size of the conductor and not 750kv
@811chicago5
@811chicago5 7 ай бұрын
@@lucasjack1531 It's definitely carrying 750,000 volts.
@picobyte
@picobyte 7 ай бұрын
@@lucasjack1531 Funfact: Our transformer is powered by 800mm² solid alu cable.
@eringold5111
@eringold5111 10 ай бұрын
Ah can you do a video on how to accurately do a 360 sweep?
@811chicago5
@811chicago5 10 ай бұрын
Yep! Thanks!
@eringold5111
@eringold5111 9 ай бұрын
@@811chicago5so when can you do 1?
@811chicago5
@811chicago5 9 ай бұрын
Soon
@carlosgaspar-luna1860
@carlosgaspar-luna1860 9 ай бұрын
Can you just wrap it and run it on 200
@811chicago5
@811chicago5 9 ай бұрын
You're going to get someone killed doing it that way.
@Utility_Detective
@Utility_Detective 9 ай бұрын
I was doing a survey at a college and I needed to get into the campus, owned electric vault where the two 750 3-phase cables came in to the switchgear to locate them and the operating engineer was terrified to go down there. I get it electric ain't no joke but goddamn this guy was scared shitless damn near.
Natural Gas: Locating Gas Service | No Place To Ground Out Transmitter
14:34
811 Chicago Utility Locating
Рет қаралды 763
Telecom Locating Fiber Optics: Interference When Using High Frequency
28:40
811 Chicago Utility Locating
Рет қаралды 1,2 М.
When you have a very capricious child 😂😘👍
00:16
Like Asiya
Рет қаралды 3,5 МЛН
Why do Power Lines use High Voltage?
6:57
Physics Ninja
Рет қаралды 72 М.
Power Lines From Indonesia
4:35
Power Lines
Рет қаралды 190 М.
High Voltage testing with SensorLink - Troubleman's kit
17:36
Bobsdecline - Lineman blogger
Рет қаралды 234 М.
Fences sucking power from under HV transmission lines
12:38
Double M Innovations
Рет қаралды 2,2 МЛН
Locating Telecommunications Cables | AT&T Network Infrastructure Exploration
21:05
811 Chicago Utility Locating
Рет қаралды 1,4 М.
THE MOST DANGEROUS JOB ON EARTH: HV CABLE INSPECTOR
2:43
intmensorg.com
Рет қаралды 2,7 МЛН
How to Install the TripSaver II Recloser
6:47
T&D World
Рет қаралды 88 М.
Completing a 360 Sweep Round Pedestal | How to Locate Cable TV Lines
16:04
811 Chicago Utility Locating
Рет қаралды 962
When you have a very capricious child 😂😘👍
00:16
Like Asiya
Рет қаралды 3,5 МЛН