#Highways

  Рет қаралды 12,955

Satish Chandra, IITR

Satish Chandra, IITR

Күн бұрын

Пікірлер: 42
@Manishyadav-fd1oc
@Manishyadav-fd1oc 2 жыл бұрын
Nice and informative video sir, thank you so much
@SatishIITR
@SatishIITR 2 жыл бұрын
Thanks, keep watching
@lakshminarayananrln1066
@lakshminarayananrln1066 2 жыл бұрын
Very informative lecture sir. Thank you !
@SatishIITR
@SatishIITR 2 жыл бұрын
Thanks for liking. Please share the link with your friends also.
@msakshay24
@msakshay24 2 жыл бұрын
Very informative video sir
@SatishIITR
@SatishIITR 2 жыл бұрын
Thanks
@vinodsharma4236
@vinodsharma4236 2 жыл бұрын
Respected Sir, Nice lecture 👍
@SatishIITR
@SatishIITR 2 жыл бұрын
Thanks a lot, keep watching
@betu2010kiit
@betu2010kiit 2 жыл бұрын
Sir, very informative! I was searching for a lecturer on this test.
@SatishIITR
@SatishIITR 2 жыл бұрын
Glad it was helpful! Keep watching
@Anaga12-mj1rd
@Anaga12-mj1rd Жыл бұрын
Sir....how to measure horizontal deformation....what instrument is used...plz reply 😢😢
@SatishIITR
@SatishIITR Жыл бұрын
LVDT is used to measure the deformation
@Anaga12-mj1rd
@Anaga12-mj1rd Жыл бұрын
Hello sir....is there any alternative...if vaccum container is not available in the laboratory
@SatishIITR
@SatishIITR Жыл бұрын
NO
@pratikjaiswal2527
@pratikjaiswal2527 6 ай бұрын
Hello sir, I am working on snow melting pavements. The application will be in snow prone regions of india like jammu kashmir, himachal pradesh etc . In this situation, should i conduct the test at 25 °C or shall i conduct it at 5-10 °C. Will the same procedure applicable if i conduct it at 5-10 °C.
@pratikjaiswal2527
@pratikjaiswal2527 6 ай бұрын
Or if not 25°C, than on what basis should i decide the testing temperature. Please suggest
@SatishIITR
@SatishIITR 6 ай бұрын
Test temperature will be the same but conditioning of specimen should be through freeze and thaw process.
@avinashmishra2254
@avinashmishra2254 2 жыл бұрын
Sir please upload lectures on Rcc minor/major bridges
@SatishIITR
@SatishIITR 2 жыл бұрын
Sorry sir, I am not touching that area of structures.
@abdurahmanifs7322
@abdurahmanifs7322 2 жыл бұрын
Which code is followed for ITS test
@SatishIITR
@SatishIITR 2 жыл бұрын
AASHTO 283, the procedure is given in IRC 111, 2009 also
@KoduruSandeepPCI
@KoduruSandeepPCI Жыл бұрын
sir i am confused with horizontal (is it across loading axis or perpendicular to it) deformation while calculating tensile strain(if possible please provide setup photo) and from which code did we get this equation.
@SatishIITR
@SatishIITR Жыл бұрын
It is perpendicular to the load on circumference of the specimen. For calculation of ITS, this strain is not needed, you need failure load only.
@KoduruSandeepPCI
@KoduruSandeepPCI Жыл бұрын
@@SatishIITRsir from which code is the equation e= o.52*x taken
@piyushgarg2137
@piyushgarg2137 2 жыл бұрын
sir i am working on a project that is use of vermiculite in bituminous pavement ( using marshall tests ). sir i want some guidance
@SatishIITR
@SatishIITR 2 жыл бұрын
How can I help you? write to me on email
@akshaydev6094
@akshaydev6094 2 жыл бұрын
Sir, How do we prepare the unconditioned samples? Do we have to cure the sample in oven at 60°C for 16h
@SatishIITR
@SatishIITR 2 жыл бұрын
NO, Keep it at room temperature and then place in a water bath at 25 C for 2 hours before testing.
@akshaydev6094
@akshaydev6094 2 жыл бұрын
@@SatishIITR ok sir, What about the air voids content in the sample? Is it corresponding to OBC or 7% air voids?
@SatishIITR
@SatishIITR 2 жыл бұрын
@@akshaydev6094 7 percent. Better to watch the video once again
@dhanrajerande6875
@dhanrajerande6875 Жыл бұрын
Sir, In case of Core from site then what about 7% air void? Is it maintain?
@sayantansasmal1352
@sayantansasmal1352 2 жыл бұрын
Sir, why we take 7% air void not any other percentage of air void? Or why test is not done in Obc?
@SatishIITR
@SatishIITR 2 жыл бұрын
This test is to evaluate the effect of water saturation and laboratory accelerated stripping in a bituminous mix. Therefore higher air voids are needed to allow the water penetration in the sample. 7 percent air voids are specified in AASHTO code to optimize this phenomenon. The test is conducted at OBC only, but with lesser number of blows so as to achieve 7 % air voids.
@moolchandsingh6650
@moolchandsingh6650 2 жыл бұрын
Sir ITS test k liye air voids % kitna hota h
@SatishIITR
@SatishIITR 2 жыл бұрын
seven percent
@GajendraSharma-w7h
@GajendraSharma-w7h 8 ай бұрын
Sir ITS and TSR procedure code
@SatishIITR
@SatishIITR 8 ай бұрын
AASHTO T 283 and ASTM D4867
@moolchandsingh6650
@moolchandsingh6650 2 жыл бұрын
Sir I am confuse How many Air voids %for ITS . For ITS -7%per ASTM D 6931air voids you give me ans on my comment today. For TSR -ITS test 7% air voids For Mr value test ITS? Given in formula 11.08*ITS-3015.8 & 1.1991*ITS+1170 in IRC 37-2018 sir Pls short out my confusen. ITS -? Tsr -?(ITS) Mr -?
@SatishIITR
@SatishIITR 2 жыл бұрын
There is no confusion. Refer IRC 111, 2009 on Specifications for DBM. It gives the procedure of determining ITS and TSR as suggested in AASHTO T283. Air Voids for ITS and TSR should be 7 percent + - 0.5 The Equation given in IRC 37 relating Mr with ITS should never be used as there is practically no correlation between these two parameters. Their testing procedure and test conditions are completely different.
@moolchandsingh6650
@moolchandsingh6650 2 жыл бұрын
Thank you sir. One more question Pls For Mr value test casted mould shall be at 7(+-0.5)%air voids or
@SatishIITR
@SatishIITR 2 жыл бұрын
@@moolchandsingh6650 Mr is determined at normal Marshall specimen as per design volumetrics (OBC and 4 % air voids)
@moolchandsingh6650
@moolchandsingh6650 2 жыл бұрын
@@SatishIITR Sir. Thank you very much
Accompanying my daughter to practice dance is so annoying #funny #cute#comedy
00:17
Funny daughter's daily life
Рет қаралды 25 МЛН
What type of pedestrian are you?😄 #tiktok #elsarca
00:28
Elsa Arca
Рет қаралды 41 МЛН
Do you love Blackpink?🖤🩷
00:23
Karina
Рет қаралды 23 МЛН
Moisture Damage Test
9:48
Virginia Asphalt Association
Рет қаралды 3,8 М.
Tensile Test
8:59
MaterialsScience2000
Рет қаралды 1,8 МЛН
COMPRESSIVE STRENGTH TEST OF CEMENT MORTAR CUBE AS PER IS 4031 PART 6
13:45
Lottmans video  for training Purposes
6:13
Colorado Asphalt Pavement Association
Рет қаралды 4,6 М.
Asphalt Performance Testing - Hamburg Wheel-Track Test (HWTT)
7:18
Federal Highway Administration USDOTFHWA
Рет қаралды 8 М.
The Incredible Strength of Bolted Joints
17:58
The Efficient Engineer
Рет қаралды 3,2 МЛН
I never understood why you can't go faster than light - until now!
16:40
FloatHeadPhysics
Рет қаралды 4,2 МЛН